Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Metastable argon dynamics in a pulsed microplasma at 43 GHz

Short pulses of millimeter wave (MMW) radiation at 43 GHz create microplasma within a photonic crystal for pressures from 40 to 600 Torr (1.3 × 10 3 –8.0 × 10 4 Pa). Gas breakdown occurs within a photonic crystal, which acts as an electromagnetic resonator to create a strong initial electric field. The time response of the argon metastable density is experimentally determined during the pulse and in the afterglow using laser absorption. The metastable density overshoots the steady-state condition at the beginning of the pulse and during the afterglow. Modeling is presented to understand these observations. The overproduction of argon 1s5 at the beginning of each pulse is due to a concurrent overshoot in the MMW electric field within the photonic crystal. This field overheats the plasma electrons and enhances the production of excited states. The burst of argon metastables observed in the afterglow is due to the pooled energy of the plasma stored in electrons, ions, and excited states of argon. As a result, understanding metastable production is an important intermediate step to ionization and is also critical in the study of diode-pumped rare gas lasers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

O · , H · , and · OH radical etching probability of polystyrene obtained for a radio frequency driven atmospheric pressure plasma jet

Atmospheric pressure plasma jets have great potential for the surface modification of polymers. In this work, the authors report on polystyrene etching by a radio frequency driven atmospheric pressure plasma jet with a focus on the role of H · , O · , and · OH radicals in this process. The absolute flux of H · , O · , and · OH radicals reaching the surface of the polymer was determined by a COMSOL MULTIPHYSICS reacting fluid dynamics model incorporating detailed transport phenomena in the boundary layer near the substrate. The simulated results of H · and · OH densities in the jet effluent were experimentally verified by two-photon absorption laser induced fluorescence and laser induced fluorescence, respectively. The carbon atom removal flux from the polystyrene surface was taken from previously reported measurements using the same plasma source. The authors show that the boundary layer effects in the interfacial region above the substrate can have a significant impact on the calculated etching probabilities. The reaction probability (β) has a significant uncertainty although a variation of 2 orders of magnitude in β leads to uncertainties of approximately 1 order of magnitude variation in the determined etching probability. The etching probability of polystyrene by · OH radicals was confirmed to be at least an order of magnitude larger than the polystyrene etching probability by O · radicals. The authors also confirmed the weak polystyrene etching probability by H · radicals. The model suggests that the presence of a 30 ppm O 2 impurity can lead to the production of · OH radicals in the far effluent of the Ar + 1% H 2 plasma jet close to the substrate at sufficient densities to enable effective etching.

36 MATERIALS SCIENCE↗

Measurements of Temperature and Enthalpy in NASA Ames 60-MW Arcjet using Atomic Oxygen and Atomic Nitrogen Absorption

We report on measurements of temperature and enthalpy in the 60-MW Interaction Heating Facility (IHF) Arcjet at the NASA Ames Research Center. These quantities were measured at sub-second temporal resolution using tunable diode laser absorption spectroscopy, employing four Distributed Feedback (DFB) lasers to simultaneously probe the arcjet flow. Optical access was achieved through a specially-designed optical disk mounted in series with the modules of the arc heater in the add-air plenum of the column, which is positioned between the downstream electrodes and the nozzle. Gas at this measurement location serves as the reservoir condition for the ensuing supersonic expansion. Conditions in the reservoir are extreme, with temperatures between 5000-8000 K and pressures between 1-9 atm. Absorption from the 5S state of atomic oxygen at 777.2 nm and the 4P state of atomic nitrogen at 868.0 nm, two electronically-excited quantum states, formed the basis of the flow characterization measurements. Fiber-coupled laser light was pitched through the IHF via 1/8" ports in the optical disks, permitting optical access with minimal intrusion to the flow. Data was collected at 3 nominal conditions, a Low condition (1600 A, 2000 V, 0.13 kg/s), a Medium condition (3500 A, 5700 V, 0.61 kg/s), and a High condition (5900 A, 6800 V, 0.84 kg/s). Measurements suggest agreement within 1-2% between excited oxygen and excited nitrogen thermometry, indicating approximate thermal and chemical equilibration of the arcjet reservoir state, a result in keeping with long-standing assumptions of CFD modelling. Spatial gradients are found in the flow due to enthalpy loss to the facility walls, but the measured spatial non-uniformities are consistent with axi-symmetry. Measurements of specific enthalpy in the reservoir are also made utilizing excited oxygen and excited nitrogen absorption under the assumption of chemical equilibration.

Peter M. Finch↗

Investigation of N2O Production from 266 and 532 nm Laser Flash Photolysis of O3/N2/O2 Mixtures

Tunable diode laser absorption spectroscopy has been employed to measure the amount of N2O produced from laser flash photolysis of O3/N2/O2 mixtures at 266 and 532 nm. In the 532 nm photolysis experiments very little N2O is observed, thus allowing an upper limit yield of 7 x 10(exp -8) to be established for the process O3 + N2 yield N2O + O2, where O3 is nascent O3 that is newly formed via O(3P(sub J)) + O2 recombination (with vibrational excitation near the dissociation energy of O3). The measured upper limit yield is a factor of approx. 600 smaller than a previous literature value and is approximately a factor of 10 below the threshold for atmospheric importance. In the 266 nm photolysis experiments, significant N2O production is observed and the N2O quantum yield is found to increase linearly with pressure over the range 100 - 900 Torr in air bath gas. The source of N2O in the 266 nm photolysis experiments is believed to be the addition reaction O(1D(sub 2)) + N2 + M yields (k(sub sigma)) N2O + M, although reaction of (very short-lived) electronically excited O3 with N2 cannot be ruled out by the available data. Assuming that all observed N2O comes from the O(1D(sub 2)) + N2 + M reaction, the following expression describes the temperature dependence of k(sub sigma) (in its third-order low-pressure limit) that is consistent with the N2O yield data: k(sub sigma) = (2.8 +/- 0.1) x 10(exp -36)(T/300)(sup -(0-88+0.36)) cm(sup 6) molecule(sup -2)/s, where the uncertainties are 2(sigma) and represent precision only. The accuracy of the reported rate coefficients at the 95% confidence level is estimated to be 30 - 40% depending on the temperature. Model calculations suggest that gas phase processes initiated by ozone absorption of a UV photon represent about 1.4% of the currently estimated global source strength of atmospheric N2O. However, these processes could account for a significant fraction of the oxygen mass-independent enrichment observed in atmospheric N2O, and they appear to be the first suggested photochemical mechanism that is capable of explaining the altitude dependence of the observed mass -independent isotopic signature.

Estupinan, E. G.↗

Nonlocal effects on thermal transport in hydrodynamic simulations of unmagnetized MagLIF-relevant gaspipes on NIF

We present simulations of heat flow relevant to gaspipe experiments on the National Ignition Facility to investigate kinetic effects on transport phenomena. D 2 and neopentane (C 5 H 12 ) filled targets are used to study the laser preheat stage of a MagLIF scheme where an axial magnetic field is sometimes applied to the target. Simulations were done with the radiation-MHD code HYDRA with a collision-dominated fluid model and the SNB nonlocal electron thermal conduction model. Using the SNB model to evolve the electron temperature increased the heat front propagation of neopentane gas targets compared to a local model by limiting radial heat flow. This increases electron temperature near the axis, which decreases laser absorption. We find that the effect of heat flow models on temperature profiles and laser propagation is modest. Beyond the SNB model, we utilize HYDRA to initialize plasma conditions for the Vlasov–Fokker–Planck K2 code. We run K2 until a quasi-steady state is reached and examine the impact of kinetic effects on heat transport. Although axial heat flow is well predicted by fluid models, the fluid model consistently overpredicts radial heat flow up to 150% in regions with the largest temperature gradient of D 2 filled gaspipes. On the other hand, the SNB nonlocal electron conduction model is found to be adequate for capturing kinetic heat flow in gaspipes.

Lau, Ryan Y. [Univ. of Colorado, Boulder, CO (Unit↗

A microscopic description of sound absorption in the atmosphere

The various mechanisms which contribute to sound absorption in the atmosphere are identified and a technique for computing the contribution from each is presented. The similarities between sound absorption, laser fluorescence measurements, and the opto-acoustic effect are discussed. Finally, experimental sound absorption results are compared to predictions to test the microscopic energy transfer approach.

Bass, H. E.↗

Kinetics of the Reactions of F((sup 2)P) and Cl((sup 2)P) with HNO3

The kinetics of the reactions of HNO3 with fluorine (k(sub 1)) and Chlorine (k(sub 2)) atoms have been studied by using a time-resolved long-path laser absorption technique to monitor the appearance of product NO3 radicals following 351-nm pulsed laser photolysis of X2/HNO3/He mixtures (X = F,Cl). Absolute rate coefficients for the F((sup 2)P) + HNO reaction have been determined over the temperature range 260-373 K. Between 260 and 320 K, the data are adequately represented by the Arrhenius expression k(sub 1)(T) = (6.0 +/- 2.6) x 10(exp -12) exp[(40 +/- 120)/T]cu cm/(molecule.s). Between 335 and 373 K, the rate coefficient is found to be (2.0 +/- 0.3) x 10(exp -11)cu cm/(molecule.s) independent of temperature. The observed temperature dependence suggests that reaction proceeds via competing direct abstraction and complex pathways. No NO3 production was observed in the experiments with X equals Cl, thus establishing that k(sub 2)(298 K) is less than 2 x 10(exp -16) cu cm/(molecule.s). The Cl((sup 2)P) + HNO reaction was also investigated by using a pulsed laser photolysis-resonance fluorescence technique to monitor the decay of Cl((sup 2)P). Upper limit values for k(sub 2) obtained from these experiments, in units of 10(exp -16)cu cm/(molecule.s), are 13 at 298 K and 10 at 400 K.

Wine, P. H.↗

Exploring cesium properties internal to the LANSCE H - ion source using resonant absorption spectroscopy

The Los Alamos Neutron Science Center (LANSCE) H - ion source has provided stable output for decades of LANL mission needs, but its maximum beam output has remained the same at ~15 mA. A roadblock to improving beam output has been a lack of thorough understanding of the internal mechanisms of LANSCE H - ion source. The LANSCE H - Ion Source Laser Diagnostic Stand (HLDS) was recently built and commissioned to explore these internal mechanisms using laser absorption techniques, to measure and diagnose dynamic H - and cesium densities. The cesium density probe is based on resonant absorption of a continuous wave diode laser tuned though the D 2 line of cesium (~852 nm). The diagnostic capabilities of HLDS will be reviewed, and measurements using the cesium laser diagnostic will be presented.

43 PARTICLE ACCELERATORS↗

Quantitative measurement of oxygen in microgravity combustion

This research combines two innovations in an experimental system which should result in a new capability for quantitative, nonintrusive measurement of major combustion species. Using a newly available vertical cavity surface-emitting diode laser (VCSEL) and an improved spatial scanning method, we plan to measure the temporal and spatial profiles of the concentrations and temperatures of molecular oxygen in a candle flame and in a solid fuel (cellulose sheet) system. The required sensitivity for detecting oxygen is achieved by the use of high frequency wavelength modulation spectroscopy (WMS). Measurements will be performed in the NASA Lewis 2.2-second Drop Tower Facility. The objective of this research is twofold. First, we want to develop a better understanding of the relative roles of diffusion and reaction of oxygen in microgravity combustion. As the primary oxidizer species, oxygen plays a major role in controlling the observed properties of flames, including flame front speed (in solid or liquid flames), extinguishment characteristics, flame size, and flame temperature. The second objective is to develop better diagnostics based on diode laser absorption which can be of real value in microgravity combustion research. We will also demonstrate diode lasers' potential usefulness for compact, intrinsically-safe monitoring sensors aboard spacecraft. Such sensors could be used to monitor any of the major cabin gases as well as important pollutants.

Silver, Joel A.↗

Experimental and Ab Initio Studies of the HDO Absorption Spectrum in the 13165-13500 1/cm Spectral Region

The HDO absorption spectrum has been recorded in the 13165 - 13500 cm(exp-1) spectral region by Intracavity Laser Absorption Spectroscopy. The spectrum (615 lines), dominated by the 2n2 + 3n3 and n1+3n3 bands was assigned and modeled leading to the derivation of 196 accurate energy levels of the (103) and (023) vibrational states. Finally, 150 of these levels have been reproduced by an effective Hamiltonian involving two vibrational dark states interacting with the (023) and ( 103) bright states. The rms deviation achieved by variation of 28 parameters is 0.05-1 cm, compared to an averaged experimental uncertainty of 0.007-1 cm, indicating the limit of validity of the effective Hamiltonian approach for HDO at high vibrational excitation. The predictions of previous ab initio calculations of the HDO spectrum were extensively used in the assignment process. The particular spectral region under consideration has been used to test and discuss the improvements of new ab initio calculations recently performed on the basis of the same potential energy surface but with an improved dipole moment surface. The improvements concern both the energy levels and the line intensities. In particular, the strong hybrid character of the n1+3n3 band is very well accounted for by the the new ab initio calculations.

Schwenke, David↗

Atmospheric CO2 Column Measurements with an Airborne Intensity-Modulated Continuous-Wave 1.57-micron Fiber Laser Lidar

The 2007 National Research Council (NRC) Decadal Survey on Earth Science and Applications from Space recommended Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) as a mid-term, Tier II, NASA space mission. ITT Exelis, formerly ITT Corp., and NASA Langley Research Center have been working together since 2004 to develop and demonstrate a prototype Laser Absorption Spectrometer for making high-precision, column CO2 mixing ratio measurements needed for the ASCENDS mission. This instrument, called the Multifunctional Fiber Laser Lidar (MFLL), operates in an intensity-modulated, continuous-wave mode in the 1.57- micron CO2 absorption band. Flight experiments have been conducted with the MFLL on a Lear-25, UC-12, and DC-8 aircraft over a variety of different surfaces and under a wide range of atmospheric conditions. Very high-precision CO2 column measurements resulting from high signal-to-noise (great than 1300) column optical depth measurements for a 10-s (approximately 1 km) averaging interval have been achieved. In situ measurements of atmospheric CO2 profiles were used to derive the expected CO2 column values, and when compared to the MFLL measurements over desert and vegetated surfaces, the MFLL measurements were found to agree with the in situ-derived CO2 columns to within an average of 0.17% or approximately 0.65 ppmv with a standard deviation of 0.44% or approximately 1.7 ppmv. Initial results demonstrating ranging capability using a swept modulation technique are also presented.

Dobler, Jeremy T.↗

Difference-frequency-based tunable absorption spectrometer for detection of atmospheric formaldehyde

High-sensitivity detection of formaldehyde (CH2O) at 3.5315 micrometers (2831.64 cm-1) is reported with a diode-laser-pumped, fiber-coupled, periodically poled LiNbO3 spectroscopic source. This source replaced the Pb-salt diode laser Dewar assembly of an existing tunable diode-laser absorption spectrometer designed for ultrasensitive detection of CH2O. Spectra are recorded with 2f-modulation spectroscopy and zero-air rapid background subtraction. Initial measurements reported here, determined from multiple measurements of a flowing 7.7 parts per billion by volume (ppbv, parts in 10(9)) CH2O in air mixture, indicate replicate precisions as low as 0.24 ppbv.

Non-NASA Center↗

Impact of flow-induced beam deflection on beam propagation in ignition scale hohlraums

Experiments examining the amount of specular reflection (or “glint”) within hohlraums containing different gas fill densities have recently been performed. Simulations of these experiments are presented that show using a single flux limiter cannot explain the decrease in glinted power with increasing gas fill density. The hypothesis that flow-induced beam deflection alters laser absorption is presented. A model is proposed that can be implemented into a ray tracing description of the laser commonly used in radiation hydrodynamic codes. It is shown that simulations using this model capture the trend with gas fill density improving agreement with measurements. This formulation is then applied to an ensemble of laser-driven inertial confinement fusion experiments performed at the National Ignition Facility. The proposed model shows little impact on the total x-ray drive on the capsule but a large impact on the resulting implosion symmetry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sensitivity of Thermal Predictions to Uncertain Surface Tension Data in Laser Additive Manufacturing

To understand the process-microstructure relationships in additive manufacturing (AM), it is necessary to predict the solidification characteristics in the melt pool. This study investigates the influence of Marangoni driven fluid flow on the predicted melt pool geometry and solidification conditions using a continuum finite volume model. A calibrated laser absorptivity was determined by comparing the model predictions (neglecting fluid flow) against melt pool dimensions obtained from single laser melt experiments on a nickel super alloy 625 (IN625) plate. Using this calibrated efficiency, predicted melt pool geometries agree well with experiments across a range of process conditions. When fluid mechanics is considered, a surface tension gradient recommended for IN625 tends to overpredict the influence of convective heat transfer, but the use of an intermediate value reported from experimental measurements of a similar nickel super alloy produces excellent experimental agreement. Despite its significant effect on the melt pool geometry predictions, fluid flow was found to have a small effect on the predicted solidification conditions compared to processing conditions. We find that this result suggests that under certain circumstances, a model only considering conductive heat transfer is sufficient for approximating process-microstructure relationships in laser AM. Extending the model to multiple laser passes further showed that fluid flow also has a small effect on the solidification conditions compared to the transient variations in the process. Furthermore, limitations of the current model and areas of improvement, including uncertainties associated with the phenomenological model inputs are discussed.

36 MATERIALS SCIENCE↗

Helium as a Surrogate for Deuterium in LPI Studies

Helium or neopentane can be used as surrogate gas fill for deuterium (D2) or deuterium-tritium (DT) in laser-plasma interaction studies. Surrogates are convenient to avoid flammability hazards or the integration of cryogenics in an experiment. To test the degree of equivalency between deuterium and helium, experiments were conducted in the Pecos target chamber at Sandia National Laboratories. Observables such as laser propagation and signatures of laser-plasma instabilities (LPI) were recorded for multiple laser and target configurations. It was found that some observables can differ significantly despite the apparent similarity of the gases with respect to molecular charge and weight. While a qualitative behaviour of the interaction may very well be studied by finding a suitable compromise of laser absorption, electron density, and LPI cross sections, a quantitative investigation of expected values for deuterium fills at high laser intensities is not likely to succeed with surrogate gases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absorption of a laser light pulse in a dense plasma.

An experimental study of the absorption of a laser light pulse in a transient, high-density, high-temperature plasma is presented. The plasma is generated around a metallic anode tip by a fast capacitive discharge occurring in vacuum. The amount of transmitted light is measured for plasmas made of different metallic ions in the regions of the discharge of high electronic density. Variation of the transmission during the laser pulse is also recorded. Plasma electrons are considered responsible for the very high absorption observed.

Mehlman-Balloffet, G.↗

Application of emerging monitoring techniques at the Illinois Basin – Decatur Project

The Illinois Basin – Decatur Project is a large-scale carbon capture and storage demonstration project located in Decatur, Illinois, USA. In this project, one million metric tons of carbon dioxide (CO 2 ) was captured from an ethanol production facility and successfully injected into a deep saline reservoir over a period of three years. The scale of this project presented an opportunity to explore emerging technologies for effective long-term monitoring of the carbon capture and storage site. This research documents the application of three emerging monitoring techniques: (1) a prototype “open-path” sensor, a method of continuously monitoring atmospheric CO 2 by applying tunable diode laser absorption spectroscopy to provide a warning system for personnel safety along pipelines and at wellheads; (2) the Greenhouse Gas Laser Imaging Tomography Experiment (GreenLITE), an automated system for measuring two-dimensional spatial distribution of atmospheric CO 2 concentrations; and (3) periodic aerial imagery, a method of documenting surface-vegetation dynamics to detect vegetative responses to CO 2 leaks. The objective of this work was to assess the advantages and limitations of these monitoring techniques and quantify their reliability over an extended deployment at an active industrial site. These results will aid in determining viability of long-term monitoring on a commercial scale.

42 ENGINEERING↗

Characterizing laser preheat for laser-driven magnetized liner inertial fusion using soft x-ray emission

Laser heating of a gas in a cylindrical liner held in by a thin foil window is a critical process in the MagLIF (magnetized liner inertial fusion) concept. Window burn-through and gas heating for OMEGA scale MagLIF cylinders as a function of time have been determined using spectrally integrated soft x-ray diagnostics. Window laser absorption is classified in terms of the emitted x-rays from the window plasma as a function of laser energy, and shows that laser energy absorbed is weakly dependent on incident intensity. Radiation-hydrodynamic simulations overestimate the amount of laser energy absorbed by the window as evidenced by the increase in x-ray radiation across several photon energy bands compared to experiments. Gas temperatures inferred from soft x-ray emission from the front 1 mm of the liner are shown to evolve in time in a similar manner to simulation predictions. In conclusion, soft x-ray emission from the gas within the region of the liner that is normally imploded is shown to meet the 100 eV requirements set by the initial point design for laser-driven MagLIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗