Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser metrology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Ptychographic X-ray speckle tracking with multi-layer Laue lens systems

The ever-increasing brightness of synchrotron radiation sources demands improved X-ray optics to utilize their capability for imaging and probing biological cells, nano-devices and functional matter on the nanometre scale with chemical sensitivity. Hard X-rays are ideal for high-resolution imaging and spectroscopic applications owing to their short wavelength, high penetrating power and chemical sensitivity. The penetrating power that makes X-rays useful for imaging also makes focusing them technologically challenging. Recent developments in layer deposition techniques have enabled the fabrication of a series of highly focusing X-ray lenses, known as wedged multi-layer Laue lenses. Improvements to the lens design and fabrication technique demand an accurate, robust, in situ and at-wavelength characterization method. To this end, a modified form of the speckle tracking wavefront metrology method has been developed. The ptychographic X-ray speckle tracking method is capable of operating with highly divergent wavefields. A useful by-product of this method is that it also provides high-resolution and aberration-free projection images of extended specimens. Three separate experiments using this method are reported, where the ray path angles have been resolved to within 4 nrad with an imaging resolution of 45 nm (full period). This method does not require a high degree of coherence, making it suitable for laboratory-based X-ray sources. Likewise, it is robust to errors in the registered sample positions, making it suitable for X-ray free-electron laser facilities, where beam-pointing fluctuations can be problematic for wavefront metrology.

36 MATERIALS SCIENCE↗

Attosecond synchronization of extreme ultraviolet high harmonics from crystals

The interaction of strong near-infrared (NIR) laser pulses with wide-bandgap dielectrics produces high harmonics in the extreme ultraviolet (XUV) wavelength range. These observations have opened up the possibility of attosecond metrology in solids, which would benefit from a precise measurement of the emission times of individual harmonics with respect to the NIR laser field. In this work, we show that, when high-harmonics are detected from the input surface of a magnesium oxide crystal, a bichromatic probing of the XUV emission shows a clear synchronization largely consistent with a semiclassical model of electron–hole recollisions in bulk solids. On the other hand, the bichromatic spectrogram of harmonics originating from the exit surface of the 200 μm-thick crystal is strongly modified, indicating the influence of laser field distortions during propagation. Our tracking of sub-cycle electron and hole re-collisions at XUV energies is relevant to the development of solid-state sources of attosecond pulses.

74 ATOMIC AND MOLECULAR PHYSICS↗

Two-color scattering for the measurement of neutrals at the edge of fusion devices

Laser two-color scattering (TCS) is proposed to detect the neutral species in the edge of fusion devices, namely, tokamaks. Here, TCS uses two wavelengths to probe both the laser Rayleigh scattering and Thomson scattering of the neutral-electron bath, with emphasis on neutral density measurements such as that of hydrogen and deuterium. Modeling of the Rayleigh scattering of tokamak neutral species under various plasma conditions (electron density and temperature) shows that, with an appropriate filtering of the Thomson signal and by going to ultraviolet-region wavelengths, identification of the Rayleigh signal can be achieved. Photon count and signal fractions are calculated in two test cases, one in the midplane region of the National Spherical Torus Experiment and one in the divertor region of DIII-D. An uncertainty analysis and discussion of the feasibility of the TCS diagnostic is also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectral deconvolution without the deconvolution: Extracting temperature from x-ray Thomson scattering spectra without the source-and-instrument function

X-ray Thomson scattering (XRTS) probes the dynamic structure factor of the system, but the measured spectrum is broadened by the combined source-and-instrument function (SIF) of the setup. In order to extract properties such as temperature from an XRTS spectrum, the broadening by the SIF needs to be removed. Recent work [Dornheim et al. Nat. Commun. 13 , 7911 (2022)] has suggested that the SIF may be deconvolved using the two-sided Laplace transform. However, the extracted information can depend strongly on the shape of the input SIF, and the SIF is in practice challenging to measure accurately. Here, we propose an alternative approach: we demonstrate that considering ratios of Laplace-transformed XRTS spectra collected at different scattering angles is equivalent to performing the deconvolution, but without the need for explicit knowledge of the SIF. From these ratios, it is possible to directly extract the temperature from the scattering spectra, when the system is in thermal equilibrium. We find the method to be generally robust to spectral noise and physical differences between the spectrometers, and we explore situations in which the method breaks down. Furthermore, the fact that consistent temperatures can be extracted for systems in thermal equilibrium indicates that non-equilibrium effects could be identified by inconsistent temperatures of a few eV between the ratios of three or more scattering angles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transitioning the NASA SLR Network to Event Timing Mode for Reduced Systematics, Improved Stability and Data Precision

NASA's legacy Satellite Laser Ranging (SLR) network produces about one-third of the global SLR data to support spacegeodesy. This network of globally distributed stations has been using Time Interval Units (TIU) for range measurements for thelast 25 + years. To improve the reliability of the SLR network and satisfy the need for stable millimeter precision data, a phasedreplacement of the TIUs in the network with picosecond-precise Event Timer Modules was initiated in 2015. This schemeallowed the time of flight and laser transmit epoch measurement to one picosecond resolution. For a network with globalscientific impact, transitioning to a new data generation metrological scheme requires significant data scrutiny and long-termscience data validation. Any long-term testing/measurement has the potential to interrupt the station's daily operational dataflow to the International Laser Ranging Service (ILRS) as the station under test will have to put its test data into quarantine.We have demonstrated a very effective way to test and implement the new device without removing the old hardware andwithout the need for the orbit analysis. This operationally noninvasive scheme performed concurrent test measurements enablinguninterrupted operational data flow to the users, while allowing simultaneous test data capture for short- and long-termsystematics and stability analysis. Extensive analysis of the test data was performed by the NASA SLR engineering team andthe ILRS Analysis Standing Committee, to uncover biases and any dependencies on the satellite ranges (for nonlinear scaleissues). Multi-ETM comparison was also performed at two of the SLR stations through the interchange of hardware to establishthe inter-device range biases and stability. Such benchmarked hardware was subsequently sent to the remaining stationsto allow traceability and normalize the network performance. The range bias intercomparison performed using the multiyearSLR data analysis agreed well with the engineering changes, thus validating the approach to flush out station-specific rangingsystematics affecting precise orbit determination. Such an improvement and rebalancing of the current network will allowan orderly transition of the current NASA SLR network operating at a maximum rate of 10 Hz to the NASA next generationSpace Geodesy Satellite Laser Ranging (SGSLR) network operating at 2 kHz (McGarry et al. in J Geod, 2018. https ://doi.org/10.1007/s0019 0-018-1191-6; Merkowitz et al. in J Geod, 2018. https ://doi.org/10.1007/s0019 0-018-1204-5).

Varghese, Thomas↗

EUV and Hard X-ray Hartmann Wavefront Sensing for Optical Metrology, Alignment and Phase Imaging

For more than 15 years, Imagine Optic have developed Extreme Ultra Violet (EUV) and X-ray Hartmann wavefront sensors for metrology and imaging applications. These sensors are compatible with a wide range of X-ray sources: from synchrotrons, Free Electron Lasers, laser-driven betatron and plasma-based EUV lasers to High Harmonic Generation. In this paper, we first describe the principle of a Hartmann sensor and give some key parameters to design a high-performance sensor. We also present different applications from metrology (for manual or automatic alignment of optics), to soft X-ray source optimization and X-ray imaging.

20 metrology↗

Long-term hybrid stabilization of the carrier-envelope phase

Controlling the carrier envelope phase (CEP) in mode-locked lasers over practically long timescales is crucial for real-world applications in ultrafast optics and precision metrology. We present a hybrid solution that combines a feed-forward technique to stabilize the phase offset in fast timescales and a feedback technique that addresses slowly varying sources of interference and locking bandwidth limitations associated with gain media with long upper-state lifetimes. We experimentally realize the hybrid stabilization system in an Er:Yb:glass mode-locked laser and demonstrate 75 hours of stabilization with integrated phase noise of 14 mrad (1 Hz to 3 MHz), corresponding to around 11 as of carrier to envelope jitter. Additionally, we examine the impact of environmental factors, such as humidity and pressure, on the long-term stability and performance of the system.

47 OTHER INSTRUMENTATION↗

Validation of Laser-Induced Fluorescent Photogrammetric Targets on Membrane Structures

The need for static and dynamic characterization of a new generation of inflatable space structures requires the advancement of classical metrology techniques. A new photogrammetric-based method for non-contact ranging and surface profiling has been developed at NASA Langley Research Center (LaRC) to support modal analyses and structural validation of this class of space structures. This full field measurement method, known as Laser-Induced Fluorescence (LIF) photogrammetry, has previously yielded promising experimental results. However, data indicating the achievable measurement precision had not been published. This paper provides experimental results that indicate the LIF-photogrammetry measurement precision for three different target types used on a reflective membrane structure. The target types were: (1) non-contact targets generated using LIF, (2) surface attached retro-reflective targets, and (3) surface attached diffuse targets. Results from both static and dynamic investigations are included.

Jones, Thomas W.↗

Hyperspectral radiance mapping and chromatic correction for temperature measurement in laser-heated diamond anvil cells

In laser-heated diamond anvil cell (DAC) experiments, the effective heated region typically decreases in size with increasing pressure, leading to steeper thermal gradients. Under these conditions, chromatic aberration in the optical path from sample to detector can significantly create bias in spectro-radiometric temperature measurement. We present a radiance-mapping approach using a hyperspectral camera that records 25 spectral channels spanning 605–875 nm at each pixel in a single exposure, providing spatially and spectrally resolved radiance in each frame. This enables chromatic effects to be recorded and corrected in data processing. We developed a procedure for hyperspectral mapping, involving per-camera calibration, crosstalk removal, measured spectral throughput functions, and optional sub-pixel co-registration to minimize chromatic distortion. The calibrated radiance maps are then used to derive temperature maps of the laser-heated hotspots. For smaller heating spots, the radiance mapping approach reveals chromatic shifts that conventional spectro-radiometric methods cannot quantify. Ambient-pressure heating experiments confirm accurate temperature retrieval. At high pressure, application of the hyperspectral system to a platinum-heating experiment at 12 GPa demonstrates stable temperature reconstruction under steep thermal gradients. Beyond mitigating chromatic aberrations, the ability to diagnose optical artifacts separately from emissivity variations during controlled test experiments or in situ suggests a path toward more rigorous spectral emissivity analysis and improved modeling of thermal transport in laser-heated DAC experiments.

47 OTHER INSTRUMENTATION↗

NASA Tech Briefs, July 2005

Thin-Film Resistance Heat-Flux Sensors Circuit Indicates that Voice-Recording Disks are Nearly Full Optical Sensing of Combustion Instabilities in Gas Turbines Topics include: Crane-Load Contact Sensor; Hexagonal and Pentagonal Fractal Multiband Antennas; Multifunctional Logic Gate Controlled by Temperature; Multifunctional Logic Gate Controlled by Supply Voltage; Power Divider for Waveforms Rich in Harmonics; SCB Quantum Computers Using iSWAP and 1-Qubit Rotations; CSAM Metrology Software Tool; Update on Rover Sequencing and Visualization Program; Selecting Data from a Star Catalog; Rotating Desk for Collaboration by Two Computer Programmers; Variable-Pressure Washer; Magnetically Attached Multifunction Maintenance Rover; Improvements in Fabrication of Sand/Binder Cores for Casting; Solid Freeform Fabrication of Composite-Material Objects; Efficient Computational Model of Hysteresis; Gauges for Highly Precise Metrology of a Compound Mirror; Improved Electrolytic Hydrogen Peroxide Generator; High-Power Fiber Lasers Using Photonic Band Gap Materials; Ontology-Driven Information Integration; Quantifying Traversability of Terrain for a Mobile Robot; More About Arc-Welding Process for Making Carbon Nanotubes; Controlling Laser Spot Size in Outer Space; or Software-Reconfigurable Processors for Spacecraft.

Source record↗

Telescope Development for LISA

A laser interferometer space-based gravitational wave observatory requires an optical telescope to efficiently transfer laser light between pairs of widely-separated sciencecraft. The application is precision interferometric metrology, and therefore requires the telescope to have high optical pathlength stability, and low scattered light performance. We summarize recent activity on the development of a telescope to meet requirements for the LISA mission, including optimization of the optical design, development of a CAD and finite element model, and thinking about how to live with a high level of particulate contamination on the optics and still meet challenging scattered light requirements.

Livas, Jeff↗

A Quantitative Method for In Situ Pump-Beam Metrology in 4D Ultrafast Electron Microscopy

In this work, we report a method for measuring spot size and focusing conditions of the femtosecond (fs) excitation laser in situ at the specimen location in 4D ultrafast electron microscopy (UEM). The method makes use of threshold laser ablation behaviors of thin amorphous carbon membranes. For Gaussian beam profiles and for ablation threshold fluence values, we analytically derive expressions describing the relationship between ablated hole size and the actual laser spot size. Using these expressions, we developed experimental procedures for characterizing the shape and spot size of the pump beam at the specimen. We demonstrate the viability of the approach for incident excitation wavelengths of 343 nm and 515 nm, thus illustrating the applicability of the method to a range of optical wavelengths without modification. Further, we show that by measuring ablated hole size as a function of focusing condition, a full metrological characterization of the Gaussian beam propagation properties can be performed. Finally, we find good agreement for spot sizes determined with this method and with those determined by extrapolation from measurements taken outside the microscope column. Overall, this method is a simple, cost-effective means for accurate and precise determination of key pump-beam parameters in situ at the specimen location in UEM experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Metrology of a Focusing Capillary Using Optical Ptychography

The focusing property of an ellipsoidal monocapillary has been characterized using the ptychography method with a 405 nm laser beam. The recovered wavefront gives a 12.5×10.4μm 2 focus. The reconstructed phase profile of the focused beam can be used to estimate the height error of the capillary surface. The obtained height error shows a Gaussian distribution with a standard deviation of 1.3 μm. This approach can be used as a quantitative tool for evaluating the inner functional surfaces of reflective optics, complementary to conventional metrology methods.

36 MATERIALS SCIENCE↗

Earthquakes and sea level - Space and terrestrial metrology on a changing planet

A review is presented of the stability and scale of crustal deformation metrology which has particular relevance to monitoring deformation associated with sea level and earthquakes. Developments in space geodesy and crustal deformation metrology in the last two decades have the potential to acquire a homogeneous global data set for monitoring relative horizontal and vertical motions of the earth's surface to within several millimeters. New tools discussed for forecasting sea level rise and damaging earthquakes include: very long baseline interferometry, satellite laser ranging, the principles of GPS geodesy, and new sea level sensors. Space geodesy permits a unified global basis for future metrology of the earth, and the continued availability of the GPS is currently fundamental to this unification.

Bilham, Roger↗

LISA Pathfinder Instrument Data Analysis

LISA Pathfinder (LPF) is an ESA-launched demonstration mission of key technologies required for the joint NASA-ESA gravitational wave observatory in space, LISA. As part of the LPF interferometry investigations, analytic models of noise sources and corresponding noise subtraction techniques have been developed to correct for effects like the coupling of test mass jitter into displacement readout, and fluctuations of the laser frequency or optical pathlength difference. Ground testing of pre-flight hardware of the Optical Metrology subsystem is currently ongoing at the Albert Einstein Institute Hannover. In collaboration with NASA Goddard Space Flight Center, the LPF mission data analysis tool LTPDA is being used to analyze the data product of these tests. Furthermore, the noise subtraction techniques and in-flight experiment runs for noise characterization are being defined as part of the mission experiment master plan. We will present the data analysis outcome of preflight hardware ground tests and possible noise subtraction strategies for in-flight instrument operations.

Guzman, Felipe↗

Range-Gated Metrology with Compact Optical Head

This work represents a radical simplification in the design of the optical head needed for high-precision laser ranging applications. The optical head is now a single fiber-optic collimator with dimensions of order of 1 1 2 cm, which can be easily integrated into the system being measured with minimal footprint.

Dubovitsky, Serge↗