Search NASA⌕ Search

SEARCH · Search NASA

Results for “load parameters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Au/Cr Sputter Coating for the Protection of Alumina During Sliding at High Temperatures

A sputter deposited bilayer coating of gold and chromium was investigated as a potential solid lubricant to protect alumina substrates in applications involving sliding at high temperature. The proposed lubricant was tested in a pin-on-disk tribometer with coated alumina disks sliding against uncoated alumina pins. Three test parameters; temperature, load, and sliding velocity were varied over a wide range in order to determine the performance envelope on the gold/chromium (Au/Cr) solid lubricant film. The tribo-tests were run in an air atmosphere at temperatures of 25 to 1000 C, under loads of 4.9 to 49.0 N and at sliding velocities from 1 to 15 m/sec. Post test analyses included surface profilometry, wear factor determination and scanning electron microscopy/energy dispersive spectroscopy (SEM/EDS) examination of worn surfaces. Compared to unlubricated Al2O3 sliding, the use of the Au/Cr film reduced friction by 30 to 50 percent and wear by one to two orders of magnitude. Increases in test temperature resulted in lower friction and the Au/Cr film continued to provide low friction, about 0.3, even at 1000 C. Pin wear factors and friction were largely unaffected by increasing loads up to 29.4 N. Sliding velocity had essentially no effect on friction, however, increased velocity reduced coating life (total sliding distance). Based upon these research results, the Au/Cr film is a promising lubricant for moderately loaded, low speed applications operating at temperatures as high as 1000 C.

Benoy, Patricia A.↗

Displacements of Metallic Thermal Protection System Panels During Reentry

Bowing of metallic thermal protection systems for reentry of a previously proposed single-stage-to-orbit reusable launch vehicle was studied. The outer layer of current metallic thermal protection system concepts typically consists of a honeycomb panel made of a high temperature nickel alloy. During portions of reentry when the thermal protection system is exposed to rapidly varying heating rates, a significant temperature gradient develops across the honeycomb panel thickness, resulting in bowing of the honeycomb panel. The deformations of the honeycomb panel increase the roughness of the outer mold line of the vehicle, which could possibly result in premature boundary layer transition, resulting in significantly higher downstream heating rates. The aerothermal loads and parameters for three locations on the centerline of the windward side of this vehicle were calculated using an engineering code. The transient temperature distributions through a metallic thermal protection system were obtained using 1-D finite volume thermal analysis, and the resulting displacements of the thermal protection system were calculated. The maximum deflection of the thermal protection system throughout the reentry trajectory was 6.4 mm. The maximum ratio of deflection to boundary layer thickness was 0.032. Based on previously developed distributed roughness correlations, it was concluded that these defections will not result in tripping the hypersonic boundary layer.

Daryabeigi, Kamran↗

Optimum Design of a Compound Helicopter

A design and aeromechanics investigation was conducted for a 100,000-lb compound helicopter with a single main rotor, which is to cruise at 250 knots at 4000 ft/95 deg F condition. Performance, stability, and control analyses were conducted with the comprehensive rotorcraft analysis CAMRAD II. Wind tunnel test measurements of the performance of the H-34 and UH-1D rotors at high advance ratio were compared with calculations to assess the accuracy of the analysis for the design of a high speed helicopter. In general, good correlation was obtained when an increase of drag coefficients in the reverse flow region was implemented. An assessment of various design parameters (disk loading, blade loading, wing loading) on the performance of the compound helicopter was conducted. Lower wing loading (larger wing area) and higher blade loading (smaller blade chord) increased aircraft lift-to-drag ratio. However, disk loading has a small influence on aircraft lift-to-drag ratio. A rotor parametric study showed that most of the benefit of slowing the rotor occurred at the initial 20 to 30% reduction of the advancing blade tip Mach number. No stability issues were observed with the current design. Control derivatives did not change significantly with speed, but the did exhibit significant coupling.

Yeo, Hyeonsoo↗

Investigation of the effect of hub support parameters on two-bladed rotor oscillatory loads

The results are presented of a test program and analysis to investigate the effects of inplane hub support parameters on the oscillatory chordwise loads of a two-bladed teetering rotor. The test program was conducted in two phases. The first consisted of a shake test to define the impedance of a number of test configurations as a function of frequency. The second phase was the test of these configurations in the NASA-Langley transonic dynamics tunnel. The test showed that the one-per-rev inplane bending moments could be changed by a factor of 2.0 as a function of the pylon configuration at the same aerodynamic operating condition. The higher harmonic inplane, flapwise, and torsional bending moments, and pitch link axial loads were not affected by changes in inplane hub impedance. The maximum inplane loads occurred for the pylon configuration with the minimum spring rate and maximum inertia.

Lee, C. D.↗

Postbuckling behavior of axially compressed graphite-epoxy cylindrical panels with circular holes

The results of an experimental and analytical study of the effects of circular holes on the postbuckling behavior of graphite-epoxy cylindrical panels loaded in axial compression are presented. The STAGSC-1 general shell analysis computer code is used to determine the buckling and postbuckling response of the panels. The loaded, curved ends of the specimens were clamped by fixtures and the unloaded, straight edges were simply supported by knife-edge restraints. The panels are loaded by uniform end shortening to several times the end shortening at buckling. The unstable equilibrium path of the postbuckling response is obtained analytically by using a method based on controlling an equilibrium-path-arc-length parameter instead of the traditional load parameter. The effects of hole diameter, panel radius, and panel thickness on postbuckling response are considered in the study. Experimental results are compared with the analytical results and the failure characteristics of the graphite-epoxy panels are described.

Knight, N. F., Jr.↗

Electrochemically Deposited Cadmium Electrode for Sealed Ni-cd Cells

An investigation into the work on electrochemical cadmium deposition processes is describred. A beaker impregnation system is constructed to investigate the practical limits of loading and the effect of various process parameters. Reasonably high loadings of cadmium are obtained and the process appears amenable to tight control and the production of uniform consistent electrodes. A pilot impregnation facility is built to further investigate electrodeposition processes. Both the inert anode and consummable anode processes are investigated. Results of this evaluation and an analysis of associated problems are presented.

Houston, W. H.↗

Minimizing Load Effects on NA4 Gear Vibration Diagnostic Parameter

NA4 is a vibration diagnostic parameter, developed by researchers at NASA Glenn Research Center, for health monitoring of gears in helicopter transmissions. The NA4 reacts to the onset of gear pitting damage and continues to react to the damage as it spreads. This research also indicates NA4 reacts similarly to load variations. The sensitivity of NA4 to load changes will substantially affect its performance on a helicopter gearbox that experiences continuously changing load throughout its flight regimes. The parameter NA4 has been used to monitor gear fatigue tests at constant load. At constant load, NA4 effectively detects the onset of pitting damage and tracks damage severity. Previous research also shows that NA4 reacts to changes in load applied to the gears in the same way it reacts to the onset of pitting damage. The method used to calculate NA4 was modified to minimize these load effects. The modified NA4 parameter was applied to four sets of experimental data. Results indicate the modified NA4 is no longer sensitive to load changes, but remains sensitive to pitting damage.

Dempsey, Paula J.↗

The Accuracy of Parameter Estimation in System Identification of Noisy Aircraft Load Measurement

This thesis focuses on the subject of the accuracy of parameter estimation and system identification techniques. Motivated by a complicated load measurement from NASA Dryden Flight Research Center, advanced system identification techniques are needed. The objective of this problem is to accurately predict the load experienced by the aircraft wing structure during flight determined from a set of calibrated load and gage response relationship. We can then model the problem as a black box input-output system identification from which the system parameter has to be estimated. Traditional LS (Least Square) techniques and the issues of noisy data and model accuracy are addressed. A statistical bound reflecting the change in residual is derived in order to understand the effects of the perturbations on the data. Due to the intrinsic nature of the LS problem, LS solution faces the dilemma of the trade off between model accuracy and noise sensitivity. A method of conflicting performance indices is presented, thus allowing us to improve the noise sensitivity while at the same time configuring the degredation of the model accuracy. SVD techniques for data reduction are studied and the equivalence of the Correspondence Analysis (CA) and Total Least Squares Criteria are proved. We also looked at nonlinear LS problems with NASA F-111 data set as an example. Conventional methods are neither easily applicable nor suitable for the specific load problem since the exact model of the system is unknown. Neural Network (NN) does not require prior information on the model of the system. This robustness motivated us to apply the NN techniques on our load problem. Simulation results for the NN methods used in both the single load and the 'warning signal' problems are both useful and encouraging. The performance of the NN (for single load estimate) is better than the LS approach, whereas no conventional approach was tried for the 'warning signals' problems. The NN design methodology is also presented. The use of SVD, CA and Collinearity Index methods are used to reduce the number of neurons in a layer.

Kong, Jeffrey↗

On dynamic loads in parallel shaft transmissions. 2: Parameter study

Solutions to the governing equations of a spur gear transmission model, developed in NASA TM-100180 (AVSCOM TM-87-C-2), are presented. Factors affecting the dynamic load are identified. It is found that the dynamic load increases with operating speed up to a system natural frequency. At operating speeds beyond the natural frequency the dynamic load decreases dramatically. Also. it is found that the applied load and shaft inertia have little effect on the dynamic load. Damping and friction decrease the dynamic load. Finally, tooth stiffness has a significant effect on dynamic loading; the higher the stiffness, the lower the dynamic loading. Also, the higher the stiffness the higher the rotating speed required for dynamic response.

Lin, Edward Hsiang-Hsi↗

FUN-BioCROP model with litter decomposition parameters derived from the LIDET dataset

This repository contains the code and data necessary to run the FUN-BioCROP (Fixation and Uptake of Nitrogen-Bioenergy Carbon, Rhizosphere, Organisms, and Protection) model with litter decomposition parameters derived from a modified Monte Carlo simulation that used the Long-term Intersite Decomposition Experiment Team dataset. Related publication:Juice, S.M., Ridgeway, J.R., Hartman, M.D., Parton, W.J., Berardi, D.M., Sulman, B.N., Allen, K.E., & Brzostek, E.R. Reparameterizing litter decomposition using a simplified Monte Carlo method improves litter decay simulated by a microbial model and alters bioenergy soil carbon estimates. Description of Files: FUNBioCROP_LIDET Study.Rmd R code with FUN-BioCROP model that can be run with 10 different sets of parameters for litter decomposition (Baseline, LIDET, or eight other best parameter sets identified in the modified Monte Carlo simulation. CORPSE Functions_Bioenergy_V2.R Code with CORPSE model functions, called by FUNBioCROP_LIDET Study.Rmd Model Input Data: bulk.csv, bulk_till.csv, rhizo.csv, rhizo_till.csv, litter.csv Initial C and N (kg C or N/m2) pool values for each soil compartment, final values from spin up. All five files have the same columns: (Column - Description - Units) uFastC - Unprotected fast decomposing carbon - kg carbon/m2 uSlowC - Unprotected slow decomposing carbon - kg carbon/m2 uNecroC - Unprotected necromass carbon - kg carbon/m2 pFastC - Protected fast decomposing carbon - kg carbon/m2 pSlowC - Protected slow decomposing carbon - kg carbon/m2 pNecroC - Protected necromass carbon - kg carbon/m2 livingMicrobeC - Carbon in living microbial biomass - kg carbon/m2 uFastN - Unprotected fast decomposing nitrogen - kg nitrogen/m2 uSlowN - Unprotected slow decomposing nitrogen - kg nitrogen/m2 uNecroN - Unprotected necromass nitrogen - kg nitrogen/m2 pFastN - Protected fast decomposing nitrogen - kg nitrogen/m2 pSlowN - Protected slow decomposing nitrogen - kg nitrogen/m2 pNecroN - Protected necromass nitrogen - kg nitrogen/m2 inorganicN - Inorganic nitrogen - kg nitrogen/m2 CO2 - Carbon in carbon dioxide - kg carbon/m2 livingMicrobeN - Nitrogen in living microbial biomass - kg nitrogen/m2 Model Input Data: FluxTower_AvgSoilT.csv: Average daily soil temperature (oC) at 10 cm depth at University of Illinois Urbana-Champaign (UIUC) Energy Farm flux tower from 7/2008-3/2016. (One year of averaged data) Model Input Data: FluxTower_AvgSoilVWC.csv: Average daily soil volumetric water content (VWC) at 10 cm depth at UIUC Energy Farm flux tower from 7/2008-3/2016. (One year of averaged data) Model Input Data: input_CCS_LIDET Study.csv: This file has daily data to run FUN-BioCROP (Column - Description - Units): yr - calendar year - year doy - day of year (1 to 365) (no leap year) - day anpp - aboveground NPP (DayCent) - kg C/m2/day bnpp - belowground NPP (DayCent) - kg C/m2/day aglivc - live aboveground biomass carbon (DayCent) - kg C/m2 bglivcj - live juvenile fine root biomass carbon (DayCent) - kg C/m2 bglivcm - live mature fine root biomass carbon (DayCent) - kg C/m2 aglivn - live aboveground biomass nitrogen (DayCent) - kg N/m2 bglivnj - live juvenile fine root biomass nitrogen (DayCent) - kg N/m2 bglivnm - live mature fine root biomass nitrogen (DayCent) - kg N/m2 nyr - simulation year - year cult - indicates a cultivation event (0 or 1) crop - indicates a new crop (0 or 1) fert - indicates a fertilizer event (0 or 1) frst - indicates the first day of the growing season (0 or 1) harv - indicates a harvest event (0 or 1) last - indicates the end of the growing season (0 or 1) croptype - crop type (0=none; 1=alfalfa; 2=corn; 3=grass clover pasture; 4=soybean; 5=wheat) cropsrl - crop specific root length - mm/g root cultrhizmix - fraction of rhizosphere mixed with bulk soil during cultivation (0.0-1.0) - fraction cultlitmix - fraction of litter mixed with bulk soil during cultivation (0.0-1.0) - fraction harvremov - fraction of above ground biomass removed during harvest (0.0-1.0) - fraction fertamt - fertilization amount - g N/m2 lifehist - plant life history (0 = annual, 1 = perennial) froot_turnover_c - amount of C in fine root turnover - kg C/m2 froot_turnover_n - amount of N in fine root turnover - kg N/m2 agrd_turnover_c - amount of C in aboveground biomass turnover - kg C/m2 agrd_turnover_n - amount of N in aboveground biomass turnover - kg N/m2 leaf_litter_fastfrac - Fast decomposing fraction of leaf litter (0.0-1.0) - fraction root_litter_fastfrac - Fast decomposing fraction of root litter (0.0-1.0) - fraction root_diameter - root diameter - mm root_length - root length - mm root/m2 rhizo_frac - fraction of total soil volume that is rhizosphere (0.0 - 1.0) - fraction date - date in format YYYY-MM-DD Instructions: Save the model code ("FUN-BioCROP_LIDET Study.Rmd") and accompanything files (data streams and CORPSE function code) in the same folder. In model code "Chunk 3: Load CORPSE Data Streams" set the working directory (setwd) to the folder with the files saved in step #1. In "Chunk 5: Define LIDET parameter sets" select the litter decomposition parameter set to be used in the run, and comment out all other sets. If changing any parameter values, edit them in "Chunk 6: Load parameters." Run all chunks up to and including "Chunk 10: Prepare Data for Export." In "Chunk 11: Export Output Data" edit data frames for export and filenames, as necessary. "Chunk 12: Graph Total Soil C" makes a figure of C remaining over the model run period. Description of each model chunk (in file FUN-BioCROP_LIDET Study.Rmd): Chunk 1: Remove all functions, clear memory. Removes all functions from R environment, clears the memory. Chunk 2: Load Packages. Loads packages necessary to run the code. Chunk 3: Load CORPSE Data Streams. Sets the working directory and loads the data files necessary to run CORPSE. Chunk 4: Load CORPSE Functions. Loads the R script with CORPSE functions from the working directory, "CORPSE Functions_Bioenergy_V2.R". Chunk 5: Define LIDET parameter sets. Has ten different parameter sets for litter decomposition tested in this study: Baseline parameters, LIDET parameters, and the other 8 best performing parameter sets identified in the modified Monte Carlo. To run the model, all but one parameter set must be commented out. Chunk 6: Load Parameters. Loads all fixed parameters to run the model. Data frame with definitions of parameters is in the CORPSE function script "CORPSE Functions_Bioenergy_V2.R" Chunk 7: Prepare Data Streams. Takes data streams loaded in Chunk 3 and puts them in the format necessary to run the model. The model is coded to run at least two sites at a time, so if only one site is being run it must be run in duplicate. Individual data tables of daily values are created in this chunk from the input data file. Chunk 8: Set Initial Conditions. Creates data tables of soil C and N pools for each soil compartment (rhizo_till, rhizo, bulk_till, bulk, litter) and loads initial values into the data tables. Creates lists for each soil compartment to hold model output. Chunk 9: Load FUN Data and Set Up Matrices. Uses DayCent data to calculate FUN input data: root and leaf N demand, total N demand, plant CN, leaf N available for retranslocation, and litter production. Creates matrices for FUN model outputs. Chunk 10: Run Model. Runs the model. Chunk 11: Prepare Data for Export. Combines data from each day saved as lists into data frames for each soil compartment. Adds values from all soil compartments together to calculate total soil values, creates separate data frames for each soil C and N pool (e.g., protected slow C) for the total soil value. Adds different C and N pools together to calculate total soil C and N for all layers. Creates data frame of ratio of protected to unprotected SOC. Organizes FUN data for export. Chunk 12: Export Results. Exports CSV files of model results to the working directory. Chunk 13: Graph Total Soil C. Makes figure of C remaining over time. Related Links: Original FUN-BioCROP model: https://github.com/BrzostekEcologyLab/FUN-BioCROP LIDET dataset: https://andlter.forestry.oregonstate.edu/data/abstract.aspx?dbcode=TD023

Juice, Stephanie↗

Capillary Isotachophoresis-Nanoelectrospray Ionization-Selected Reaction Monitoring MS via a Novel Sheathless Interface for High Sensitivity Sample Quantification

A novel sheathless CITP/CZE-MS interface featuring a large i.d. separation capillary and a detachable small i.d. ESI emitter was developed in this study to simultaneously achieve large sample loading capacity and stable nanoESI operation. Crucial operating parameters, including sample loading volume, flow rate, and separation window, were systematically investigated to attain optimum CITP/CZE separation efficiency and MS detection sensitivity. The performance of CITP/CZE-nanoESI-MS using the new sheathless interface was evaluated for its achievable low limit of quantitation (LOQ) by analyzing targeted peptides, leu-enkephalin and angiotensin II, spiked in a BSA tryptic digest matrix at different concentrations. A linear dynamic range spanning 4.5 orders of magnitude and a 10 pM LOQ with excellent measurement reproducibility were obtained experimentally for both targeted peptides, representing a 5-fold sensitivity improvement as compared to using the sheath liquid interface developed previously.

Environmental Molecular Sciences Laboratory↗

Method and apparatus for measuring a peak load

The present subject matter discloses a method of measuring a peak load, including the steps of placing an indenter between a first surface and a second surface, exerting a load on at least one of the first and second surfaces, measuring at least one of a width, depth, radial chord length, and cross-sectional area of an indentation formed by the indenter in at least one of the first and second surfaces; and converting the measured parameter into a load value. Certain methods further include the steps of converting the measured parameter into a load per length value and obtaining a load value by integrating along a circumferential length of the indentation. In still other methods, the exerted load is a compressive load.

Bullen, David A.↗

Market-Based Coordination of Thermostatically Controlled Loads—Part I: A Mechanism Design Formulation

This paper focuses on the coordination of a population of Thermostatically Controlled Loads (TCLs) with unknown parameters to achieve group objectives. The problem involves designing the bidding and market clearing strategy to motivate self-interested users to realize efficient energy allocation subject to a peak power constraint. Using the mechanism design approach, we propose a market-based coordination framework, which can effectively incorporate heterogeneous load dynamics, systematically deal with user preferences, account for the unknown load model parameters, and enable the real-world implementation with limited communication resources. This paper is divided into two parts. Part I presents a mathematical formulation of the problem and develops a coordination framework using the mechanism design approach. Part II presents a learning scheme to account for the unknown load model parameters, and evaluates the proposed framework through realistic simulations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Storage peak gas-turbine power unit

A storage gas-turbine power plant using a two-cylinder compressor with intermediate cooling is studied. On the basis of measured characteristics of a .25 Mw compressor computer calculations of the parameters of the loading process of a constant capacity storage unit (05.3 million cu m) were carried out. The required compressor power as a function of time with and without final cooling was computed. Parameters of maximum loading and discharging of the storage unit were calculated, and it was found that for the complete loading of a fully unloaded storage unit, a capacity of 1 to 1.5 million cubic meters is required, depending on the final cooling.

Tsinkotski, B.↗

Numerical Simulation of Thermodynamic Parameters of High-Porosity Copper

We propose that a modified equation of state be used for calculating the thermodynamically equilibrium TEC2 model for improving the reliability of description of thermodynamic parameters of shock loading of pure materials and heterogeneous mixtures of various porosities. For copper, the parameters of a thermally consistent equation of state have been determined. A reliable description of shock-wave loading of copper has been obtained using a small number of fitting parameters determined from the concordance with experimental data. Thermodynamic parameters have been simulated for copper with various porosities; the compression ratio and the temperature along the shock adiabat have been determined, and the value of heat capacity along the normal isobar has been calculated. The results of calculations are compared with available experimental results obtained by different authors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tungsten dust impact on ITER-like plasma edge

The impact of tungsten dust originating from divertor plates on the performance of edge plasma in ITER-like discharge is evaluated using computer modeling with the coupled dust-plasma transport code DUSTT-UEDGE. Different dust injection parameters, including dust size and mass injection rates, are surveyed. It is found that tungsten dust injection with rates as low as a few mg/s can lead to dangerously high tungsten impurity concentrations in the plasma core. Dust injections with rates of a few tens of mg/s are shown to have a significant effect on edge plasma parameters and dynamics in ITER scale tokamaks. The large impact of certain phenomena, such as dust shielding by an ablation cloud and the thermal force on tungsten ions, on dust/impurity transport in edge plasma and consequently on core tungsten contamination level is demonstrated. It is also found that high-Z impurities provided by dust can induce macroscopic self-sustained plasma oscillations in plasma edge leading to large temporal variations of edge plasma parameters and heat load to divertor target plates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment of Wind Parameter Sensitivity on Extreme and Fatigue Wind Turbine Loads

Wind turbines are designed using a set of simulations to ascertain the structural loads that the turbine could encounter. While mean hub-height wind speed is considered to vary, other wind parameters such as turbulence spectra, sheer, veer, spatial coherence, and component correlation are fixed or conditional values that, in reality, could have different characteristics at different sites and have a significant effect on the resulting loads. This paper therefore seeks to assess the sensitivity of different wind parameters on the resulting ultimate and fatigue loads on the turbine during normal operational conditions. Eighteen different wind parameters are screened using an Elementary Effects approach with radial points. As expected, the results show a high sensitivity of the loads to the turbulence standard deviation in the primary wind direction, but the sensitivity to wind shear is often much greater. To a lesser extent, other wind parameters that drive loads include the coherence in the primary wind direction and veer.

17 WIND ENERGY↗