Search NASA⌕ Search

SEARCH · Search NASA

Results for “loop currents”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Celeritas R&D Report: Accelerating Geant4

Celeritas is a new Monte Carlo (MC) detector simulation code designed for computationally intensive applications on high-performance heterogeneous architectures. In the past two years Celeritas has advanced from prototyping a Graphics Processing Unit (GPU)-based single physics model in infinite medium to implementing a full set of electromagnetic (EM) physics processes in complex geometries. The current release of Celeritas, version 0.4, has incorporated full device-based navigation, an event loop in the presence of magnetic fields, and detector hit scoring. New functionality incorporates a scheduler to offload electromagnetic physics to the GPU within a Geant4-driven simulation, enabling straightforward integration of Celeritas into the high energy physics (HEP) experimental frameworks CMSSW and ATLAS FullSimLight. On the Perlmutter supercomputer, Celeritas performs EM physics between 3× and 18× faster using the machine’s Nvidia GPUs compared to using only CPUs, corresponding to an electrical power efficiency up to a factor of 5. When running a multithreaded Geant4 ATLAS test beam application with full hadronic physics, using Celeritas to accelerate the EM physics results in an overall simulation speedup of 1.7–2.2× on GPU and 1.2× on CPU. In a CMS test application using tt¯ events and the prototype Run 4 configuration, compared to Geant4 CPU, Celeritas with a Nvidia A100 improves overall throughput up to a factor of 2.7× but cannot be efficiently shared with more than 8 cores.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modular, multi-channel, interleaved power converters

A multi-phase power converter includes two or more multi-phase, bi-directional, multi-level, switching power converter subcircuits, connected in parallel at respective AC and DC sides, so as to provide a multi-channel, bi-directional, multi-level configuration. The AC sides of the switching converter subcircuits are directly coupled to one another and to a multi-phase AC input via series interface reactors, and the DC sides of the switching converter subcircuits are directly connected to one another and to a common split-capacitor bank at each level of the multi-level outputs of the switching converter subcircuits. A control circuit is configured to selectively control one or more switching semiconductor devices in each of the switching converter subcircuits. In some embodiments, the control circuit includes a closed-loop zero-sequence controller and a zero-sequence generator configured to eliminate circulating current among the switching converter subcircuits and to balance voltages across levels of the common split-capacitor bank.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment and Commissioning of Electrical Substation Grid Testbed with a Real-Time Simulator and Protective Relays/Power Meters in the Loop

Electrical utility substations are wired with intelligent electronic devices (IEDs), such as protective relays, power meters, and communication switches. Substation engineers commission these IEDs to assess the appropriate measurements for monitoring, control, power system protection, and communication applications. Like real electrical utility substations, complex electrical substation grid testbeds (ESGTs) need to be assessed for measuring current and voltage signals in monitoring, power system protection, control (synchro check), and communication applications that are limited by small measurement percentage errors. In the process of setting an ESGT with real-time simulators and IEDs in the loop, protective relays, power meters, and communication devices must be commissioned before running experiments. In this study, an ESGT with IEDs and distributed ledger technology was developed. The ESGT with a real-time simulator and IEDs in the loop was satisfactorily assessed and commissioned. The commissioning and problem-solving tasks of the testbed are described to define a method with flowcharts to assess possible trouble-shooting in ESGTs. This method was based on comparing the simulations versus IED measurements for the phase current and voltage magnitudes, three-phase phasor diagrams, breaker states, protective relay times with selectivity coordination at electrical faults, communication data points, and time-stamp sources.

Piesciorovsky, Emilio↗

Fifth-Generation District Heating and Cooling Substations: Demand Response with Artificial Neural Network-Based Model Predictive Control

District heating and cooling (DHC) is considered one of the most sustainable technologies to meet the heating and cooling demands of buildings in urban areas. The fifth-generation district heating and cooling (5GDHC) concept, often referred to as ambient loops, is a novel solution emerging in Europe and has become a widely discussed topic in current energy system research. 5GDHC systems operate at a temperature close to the ground and include electrically driven heat pumps and associated thermal energy storage in a building-sited energy transfer station (ETS) to satisfy user comfort. This work presents new strategies for improving the operation of these energy transfer stations by means of a model predictive control (MPC) method based on recurrent artificial neural networks. The results show that, under simple time-of-use utility rates, the advanced controller outperforms a rule-based controller for smart charging of the domestic hot water (DHW) thermal energy storage under specific boundary conditions. By exploiting the available thermal energy storage capacity, the MPC controller is capable of shifting up to 14% of the electricity consumption of the ETS from on-peak to off-peak hours. Therefore, the advanced control implemented in 5GDHC networks promotes coupling between the thermal and the electric sector, producing flexibility on the electric grid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Improved Beam Position Monitor for Scorpius and the DARHT Multi-Pulse Test Line

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). A frequently used BPM detector is the B-dot loop, which generates a signal from the EMF generated by the time varying magnetic flux through the loop. We have developed a second generation BPM that avoids previously observed diffusion effects in earlier stainless steel through the use of exceptionally high conductivity copper alloy for its construction.

43 PARTICLE ACCELERATORS↗

An Ultra-Fast Inrush-Current-Free Startup Method for Grid-tie Inverter without Voltage Sensors

This paper proposes an ultra-fast inrush-currentfree startup method for grid-tie inverters without voltage sensors and phase-locked loop (PLL). Traditionally, the grid-tie inverter needs the voltage measured from points of common couplings (PCC) to generate the phase angle via PLL for inverter pulsewidth- modulation (PWM) signals. The startup procedure is slow and inrush current occurs if the initial PWM does not match the unknown grid voltage well. This paper proposes a startup method that only uses measured inverter ac currents to generate the initial PWM by controlling the current to zero. The generated PWM pattern can be used to reproduce the real grid voltage regardless of the grid impedance. The zero-crossing points of the grid voltage are detected and then used for grid synchronization. The proposed startup procedure only needs a few cycles (16.67 ms/cycle) to reliably synchronize the inverter to the grid without any inrush current. Simulation and experimental results are presented to verify the effectiveness of this control strategy.

He, Yuchen↗

Robust Stabilization of Inverter-Based Resources Using Virtual Resistance-Based Control

This letter proposes a virtual resistance-based nonlinear control to stabilize and robustify the current layer of inverter-based resources, subject to the grid voltage disturbances, and the grid parameter uncertainties. A class of virtual resistances is proposed and analyzed using concepts from dissipative systems theory. Moreover, specific nonlinear virtual resistance-based controllers are derived, with their corresponding performance analytically bounded. Here, the theoretical and simulation results show that the proposed nonlinear virtual resistance-based controllers significantly reduce the L 2 gain of the closed-loop error system to grid voltage variation and parametric uncertainties. Significant improvements of the transient and steady-state current responses are also demonstrated over linear virtual resistance counterparts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A multiscale packed-bed reactor model for sustainable ethylene production via chemical looping oxidative coupling of methane

The rising global warming concerns and shale gas discovery have prompted research in the direction of greenhouse gas (GHG), such as methane, reduction and conversion. Oxidative coupling of methane (OCM) offers a pathway to low carbon-intense valorization of methane while producing ethylene, a chemical regarded as central to the petrochemical industry. Even after decades of OCM discovery, researchers keep understanding the process and underlying chemical reactions in a pursuit to achieve industrial viability for OCM. Here, in general, OCM suffers from low C 2 selectivity, yield and reactor temperature runaways due to highly exothermic nature of its reactions. Computational Fluid Dynamics (CFD) tools help analyze spatial gradients within the reactor to deeply understand the diffusion of species, mass and heat transfer phenomena. Furthermore, challenges associated with scaling up such as hot spot formation and parametric sensitivity can be addressed without having to expend on costly experiments. The current paper presents a multiscale packed-bed reactor CFD model coupled with a chemical kinetic model for the chemical looping OCM. The CFD model includes two scales i.e., macroscale for catalyst bed and microscale for individual pellets. Moreover, a chemical kinetic model based on 10 gas-phase reactions is integrated with the CFD model. An additional surface reaction for the formation of gas-phase oxygen from catalyst surface is added to account for the absence of feed oxygen. The model is calibrated against experimental results. The calibrated model captures trends in CH 4 conversion, C 2 selectivity and C 2 yield within a ± 4.35 % range across a temperature range of 700-900 °C. Moreover, model fidelity is evaluated by varying key computational parameters such as mesh resolution and time step size. The model is also verified by varying the inlet methane concentration and the gas hourly space velocity (GHSV) and comparing the results with literature. A sensitivity analysis and scale-up of the current model is undergoing.

Chemical looping↗

Evidence for 4e charge of Cooper quartets in a biased multi-terminal graphene-based Josephson junction

Abstract In a Josephson junction (JJ) at zero bias, Cooper pairs are transported between two superconducting contacts via the Andreev bound states (ABSs) formed in the Josephson channel. Extending JJs to multiple superconducting contacts, the ABSs in the Josephson channel can coherently hybridize Cooper pairs among different superconducting electrodes. Biasing three-terminal JJs with antisymmetric voltages, for example, results in a direct current (DC) of Cooper quartet (CQ), which involves a four-fermion entanglement. Here, we report half a flux periodicity in the interference of CQ formed in graphene based multi-terminal (MT) JJs with a magnetic flux loop. We observe that the quartet differential conductance associated with supercurrent exhibits magneto-oscillations associated with a charge of 4 e , thereby presenting evidence for interference between different CQ processes. The CQ critical current shows non-monotonic bias dependent behavior, which can be modeled by transitions between Floquet-ABSs. Our experimental observation for voltage-tunable non-equilibrium CQ-ABS in flux-loop-JJs significantly extends our understanding of MT-JJs, enabling future design of topologically unique ABS spectrum.

36 MATERIALS SCIENCE↗

Low leakage current in heteroepitaxial Al 0.7 Sc 0.3 N ferroelectric films on Ga N

Wurtzite ( Al , Sc ) N ferroelectrics are attractive for microelectronics applications due to their chemical and structural compatibility with wurtzite semiconductors, such as Ga N and ( Al , Ga ) N . However, the leakage current in epitaxial stacks reported to date should be reduced for reliable device operation. Here, we demonstrate low leakage current in epitaxial Al 0.7 Sc 0.3 N films on Ga N with well-saturated ferroelectric hysteresis loops that are orders of magnitude lower (i.e., 0.07 A cm − 2 ) than previously reported films (1–19 A cm − 2 ) having similar or better structural characteristics. We also show that, for these high-quality epitaxial ( Al , Sc ) N films, structural quality (edge and screw dislocations), as measured by diffraction techniques, is not the dominant contributor to leakage. Instead, the small leakage in our films is limited by thermionic emission across the interfaces, which is distinct from the large leakage due to trap-mediated bulk transport in the previously reported ( Al , Sc ) N films. To support this conclusion, we show that Al 0.7 Sc 0.3 N on lattice-matched In 0.18 Ga 0.82 N buffers with improved structural characteristics but higher interface roughness exhibit increased leakage characteristics. This demonstration of low leakage current in heteroepitaxial ( Al , Sc ) N films and understanding of the importance of interface barrier and surface roughness can guide further efforts toward improving the reliability of wurtzite ferroelectric devices. Published by the American Physical Society 2025

36 MATERIALS SCIENCE↗

Development of a Colorimetric Loop-Mediated Isothermal Amplification Assay for the Detection of Trypanosoma cruzi in Low-Resource Settings

Chagas disease is an inflammatory parasitic infection caused by Trypanosoma cruzi (T. cruzi). Early diagnosis is crucial in guiding treatment and slowing disease progression; however, current diagnostic methods have insufficient detection limits and often require skilled technicians. Molecular tests, especially isothermal nucleic acid assays, are advantageous due to their excellent sensitivity, specificity, speed, and simplicity. Here, we optimized a colorimetric loop-mediated isothermal amplification (LAMP) assay for T. cruzi. We can detect as few as 2 genomic copies/reaction using three different T. cruzi strains. We examined selectivity using other parasitic protozoans and successfully detected T. cruzi DNA extracted from parasites in human whole blood down to 1.2 parasite equivalents/reaction. We also performed a blinded study using canine blood samples and established a 100% sensitivity, specificity, and accuracy for the colorimetric LAMP assay. Finally, we used a heated 3D printer bed and an insulated thermos cup to demonstrate that the LAMP incubation step could be performed with accessible, low-cost materials. Altogether, we have developed a high-performing assay for T. cruzi with a simple colorimetric output that would be ideal for rapid, low-cost screening at the point of use.

60 APPLIED LIFE SCIENCES↗

A Generic and Multifunctional Electromagnetic Transient Model for Grid-Following Inverters

This article presents a generic and multi-functional electromagnetic transient (EMT) dynamic model of grid following (GFL) inverter-based resource (IBR) using the PSCAD software platform. The features of the developed model includes the flexibility in selecting various types and combinations of DC sources covering PV modules, battery modules, ideal DC source module, as well as flexibility in selecting either switched or averaged model of inverter. This model also covers exhaustive lists of controller logic covering open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control along with the conventional current control designed in dq-domain, ate- domain and positive-negative sequence domain. Moreover, this model is equipped with the flexibility in selecting various types of current limiting schemes that includes saturation-based as well as latching-based current limiter, anti-windup protection. Moreover, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by being complaint with the IEEE Std. 2800. The generality in the power circuits and the multi-functional options in operation and control of the developed EMT model makes it suitable for both academia and industry to study various power system aspects not limited to but such as fault behavior of GFL IBR and impacts on protection system, transient stability of a system interfaced with large number of GFL IBRs etc.

14 SOLAR ENERGY↗

A Generic and Multi-Functional Electromagnetic Transient Model for Grid-Following Inverter: Preprint

This article presents a generic and multi-functional electromagnetic transient (EMT) dynamic model of grid following (GFL) inverter-based resource (IBR) using the PSCAD TM software platform. The features of the developed model includes the flexibility in selecting various types and combinations of DC sources covering PV modules, battery modules, ideal DC source module, as well as flexibility in selecting either switched or averaged model of inverter. This model also covers exhaustive lists of controller logic covering open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control along with the conventional current control designed in dq-domain, aB- domain and positive-negative sequence domain. Moreover, this model is equipped with the flexibility in selecting various types of current limiting schemes that includes saturation-based as well as latching-based current limiter, anti-windup protection. Moreover, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by being complaint with the IEEE Std. 2800. The generality in the power circuits and the multi-functional options in operation and control of the developed EMT model makes it suitable for both academia and industry to study various power system aspects not limited to but such as fault behavior of GFL IBR and impacts on protection system, transient stability of a system interfaced with large number of GFL IBRs etc.

grid following inverter↗

SPC-71145 Rev 0 MARVEL Process Heat Extraction System Conceptual Design

The Microreactor Applications Research Validation and Evaluation (MARVEL) reactor will offer experimental capabilities that are not currently available at DOE’s national laboratories. The MARVEL reactor is a microreactor which uses eutectic sodium-potassium alloy (NaK) as a primary coolant. The primary coolant is circulated through four primary loops by natural convection of the coolant. In each loop is a closed well which will accommodate an intermediate heat exchanger (IHX) for extracting heat from the loop. These wells will be referred to in this specification as the “IHX wells”. It is intended for the IHX containment to also be filled with NaK. The MARVEL design team is currently looking for alternative means of extracting heat from these wells to be utilized in downstream applications. This Heat Utilization System (HUS) will enable MARVEL operations including the ability to test, demonstrate, and address issues related to installation, startup, and operations. In addition, it will allow down-stream utilization of process heat for various uses. Depending on the methodology used, the interface between the secondary coolant and the HUS is the Process Heat Extraction System (PHES) and is the subject of this specification.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Correlating microstructure and mechanical properties of harvested high dose Zorita light water reactor internals

Here, in this study, microstructural studies and micro-mechanical testing of an ex-plant material harvested from the decommissioned pressurized water reactor (PWR) is carried out. Irradiated 304 stainless steel (SS) components were harvested by the Electric Power Research Institute, U.S. Nuclear Regulatory Commission, and members of the José Cabrera Nuclear Power Station (Zorita) in Spain. The bi-crystalline micro-tensile specimens, atom probe tomography (APT) tips, and transmission electron microscopy (TEM) lamellae were fabricated from the baffle plate materials irradiated to 0.05, 15 and 50 dpa to elucidate microstructural, microchemical, and local mechanical properties changes as a function of dose. TEM and APT studies reveal radiation induced Ni, Cr, and Si rich precipitates in the 15 dpa sample that become smaller and partially redissolve into the matrix of the 50 dpa sample (decreasing size and number density). Dislocation loop and cavity number density and size were quantified as a function of dose as well as swelling. Intergranular Ni and Si enrichments with concomitant Fe and Cr depletion were observed in the 15 dpa sample and were more pronounced in the 50 dpa sample. Micro-tensile testing performed in the scanning electron microscope (SEM) at room temperature and 300 °C shows that the material's local yield strength and ultimate tensile strength decreases with increased dose and elevated test temperature and provides further insights via localized strain mapping. Current and previous mechanical data was compared with calculated values using the dispersed barrier hardening model with inputs of dislocation loops, precipitates, and cavities from microstructural characterization.

36 MATERIALS SCIENCE↗

Survey of Advanced Generation IV Reactor Parameters for Integrated Energy System Modeling Capabilities

This paper is to categorize and characterize advanced Generation IV nuclear reactors that are not water based according to the key parameters for the Integrated Energy Systems (IES) project[1]. A key goal of the IES project is to assess the economic viability of including an advanced nuclear reactor into an IES. The landscape of advanced reactors is heterogeneous: several unique designs with different heat profiles are currently being studied and designed. This report provides a high-level perspective of advanced reactor concepts, including primary loop nuclear output temperatures and operation schemes that could affect secondary side power production or storage. For example, this report addresses the type of thermodynamic system (Brayton, supercritical CO 2 [S-CO 2 ], etc.) and the various pressures and temperatures on the secondary side that are expected to be provided by the various primary side reactor types. Based on these characteristics, it may be possible to determine which type of nuclear power plant could be the most economical for analysis in the IES framework for power production coupled with energy storage and waste heat utilization. The results of this effort will serve as input for model development of various secondary side components, concentrating on off-the-shelf capabilities for current and near future secondary side power generation and heat rejection as simulated in TRANSFORM. Generic models can be created which are agnostic of the nuclear energy supply without violating intellectual property rights of the developer. These models can be used to make informed decisions on the economics of integrating various energy system components with nuclear plant designs. Once complete, conclusions may be drawn regarding (1) the economics, efficiency, and reliability of certain nuclear reactors, (2) certain industry processes and energy storage systems, and (3) prioritization of certain reactor types with the studied industry types.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validation of prediction capability of operating space for plasma initiation in MAST-U

DYON is a plasma initiation modelling code that solves the differential equation system of the full circuit equations (plasma current, active coil currents and eddy currents in full passive structures) and 0D global energy and particle balance equations (Kim 2022 Nucl. Fusion 62 126012). In order to test the capability of the full electromagnetic plasma initiation model to predict individual discharges in experiments and thus the operating space in the device, a dedicated experimental database was built in MAST-U by scanning the prefilled gas pressure p 0 and the induced loop voltage V loop . In the experimental operating space of p 0 and V loop the lower and the upper limits of p 0 are determined by the plasma breakdown failure and the plasma burn-through failure, respectively. The lower limit of V loop is determined by the plasma burn-through failure. By directly reading the control room data used in each discharge (i.e. currents in the solenoid, poloidal field coils, and toroidal field coils, p 0 , and gas puffing rate), the full electromagnetic DYON consistently predicted the failed breakdown, failed burn-through, and successful plasma initiation discharges in the experimental database, demonstrating its capability to predict the operating space for inductive plasma initiation. The Paschen curve calculated with the effective connection length in MAST-U indicates a much higher p 0 required for plasma breakdown than the experimental data, indicating that individual field line evaluation is necessary to calculate the quantitative requirements for Townsend breakdown. The demonstration in this paper shows that the full electromagnetic DYON could be a useful simulation tool to assess the feasibility of inductive plasma initiation and to optimise operating scenarios in future devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-Sim Interface: Enabling Multi-resolution Simulation and X-in-the-Loop Development for Connected and Automated Vehicles

We report connected and automated vehicles (CAVs) can bring safety, mobility, and energy benefits to transportation systems. Ideally, CAV applications would be fully evaluated and validated prior to real-world implementation. However, many technical challenges in both software and hardware hinder the process. To comprehensively evaluate all aspects of CAV applications, an integrated evaluation environment is needed with various simulation tools from different domains. In the current literature, there lacks a well-developed interface to enable multi-resolution simulation of vehicle, traffic, virtual environment, and hardware-in-the-loop (HIL) simulation. In this work, a modular and flexible interface is developed to enable multi-resolution vehicle and traffic co-simulation for CAV applications. This interface is built upon Oak Ridge National Laboratory’s (ORNL’s) Real-Sim approach, can support various simulation tools and real-time X-in-the-loop (XIL) simulations, and is based on network communication protocols. The network communication delays are analyzed for simultaneous connection of up to 20 simulators. Then, two example applications are studied to demonstrate the potential usage of the Real-Sim interface: (1) a centralized merging scenario where the dynamics of two ego vehicles are emulated with detailed vehicle and powertrain dynamics models and (2) a signal-controller-in-the-loop (SCIL) evaluation where one intersection of the simulated traffic scenario is controlled by a physical signal controller. This Real-Sim interface is a tool that allows researchers to bring real, tangible hardware and software into simulated environments to comprehensively evaluate and support a wide variety of CAV applications.

33 ADVANCED PROPULSION SYSTEMS↗