Search NASA⌕ Search

SEARCH · Search NASA

Results for “manufacturing visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

219 records · Page 13

Effect of Vertical Rate Error on Recovery from Loss of Well Clear Between UAS and Non-Cooperative Intruders

When an Unmanned Aircraft System (UAS) encounters an intruder and is unable to maintain required temporal and spatial separation between the two vehicles, it is referred to as a loss of well-clear. In this state, the UAS must make its best attempt to regain separation while maximizing the minimum separation between itself and the intruder. When encountering a non-cooperative intruder (an aircraft operating under visual flight rules without ADS-B or an active transponder) the UAS must rely on the radar system to provide the intruders location, velocity, and heading information. As many UAS have limited climb and descent performance, vertical position andor vertical rate errors make it difficult to determine whether an intruder will pass above or below them. To account for that, there is a proposal by RTCA Special Committee 228 to prohibit guidance systems from providing vertical guidance to regain well-clear to UAS in an encounter with a non-cooperative intruder unless their radar system has vertical position error below 175 feet (95) and vertical velocity errors below 200 fpm (95). Two sets of fast-time parametric studies was conducted, each with 54000 pairwise encounters between a UAS and non-cooperative intruder to determine the suitability of offering vertical guidance to regain well clear to a UAS in the presence of radar sensor noise. The UAS was not allowed to maneuver until it received well-clear recovery guidance. The maximum severity of the loss of well-clear was logged and used as the primary indicator of the separation achieved by the UAS. One set of 54000 encounters allowed the UAS to maneuver either vertically or horizontally, while the second permitted horizontal maneuvers, only. Comparing the two data sets allowed researchers to see the effect of allowing vertical guidance to a UAS for a particular encounter and vertical rate error. Study results show there is a small reduction in the average severity of a loss of well-clear when vertical maneuvers are suppressed, for all vertical error rate thresholds examined. However, results also show that in roughly 35 of the encounters where a vertical maneuver was selected, forcing the UAS to do a horizontal maneuver instead increased the severity of the loss of well-clear for that encounter. Finally, results showed a small reduction in the number of severe losses of well-clear when the high performance UAS (2000 fpm climb and descent rate) was allowed to maneuver vertically, and the vertical rate error was below 500 fpm. Overall, the results show that using a single vertical rate threshold is not advisable, and that limiting a UAS to horizontal maneuvers when vertical rate errors are above 175 fpm can make a UAS less safe about a third of the time. It is suggested that the hard limit be removed, and system manufacturers instructed to account for their own UAS performance, as well as vertical rate error and encounter geometry, when determining whether or not to provide vertical guidance to regain well-clear.

detect and avoid↗

Flow pattern and void fraction characterization in nitrogen/water flows through a diamond-type triply periodic minimal surface lattice

Here, this study presents, to the authors knowledge, the first experimental investigation on the void fraction and flow patterns in two-phase flows through a diamond-type Triply Periodic Minimal Surface (TPMS) lattice. An additively manufactured TPMS structure was tested under upward co-current flow of a water/nitrogen mixture. Superficial velocities varied for a total of 42 test conditions (gas: 0.01–2.4 m/s; liquid: 0.01–2.4 m/s; mass flux: 20–2370 kg/m 2 ·s). High-speed video and X-ray imaging enabled time-averaged void fraction measurements and identified six distinct flow regimes which were used to develop a flow pattern map. Comparison of the void fraction data with correlations from literature demonstrated the Rouhani and Axelsson (1970) [49] correlation modified by Steiner (1993) [52] provided the best agreement, which was improved with empirically fit coefficients. This approach predicted the void fraction with errors < ±20% for 64% of the data, with a mean absolute percent deviation (MAPD) of 23%. The measured frictional pressure drop was compared to correlations from literature which captured the observed trends but did not provide good accuracy. The best agreement was found after optimizing the empirical coefficients of the Muller-Steinhagen & Heck (1986) [56] correlation; this approach captured 33% of the data within ±20% with a MAPD of 46% over the full range and captured 71% of the data within ±20% a MAPD of 13.3% at mass fluxes >1100 kg/m 2 -s. These results provide foundational insight into TPMS two-phase flow behavior and inform modeling and design of advanced heat exchange components incorporating TPMS geometries.

42 - ENGINEERING↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗