Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Solid-state coherent laser radar wind shear measuring systems

Coherent Technologies, Inc. (CTI) was established in 1984 to engage in the development of coherent laser radar systems and subsystems with applications in atmospheric remote sensing, and in target tracking, ranging and imaging. CTI focuses its capabilities in three major areas: (1) theoretical performance and design of coherent laser radar system; (2) development of coherent laser radar systems for government agencies such as DoD and NASA; and (3) development of coherent laser radar systems for commercial markets. The topics addressed are: (1) 1.06 micron solid-state coherent laser radar system; (2) wind measurement using 1.06 micron system; and flashlamp-pumped 2.09 micron solid-state coherent laser radar system.

Huffaker, R. Milton↗

Condensation-nuclei (Aitken Particle) measurement system used in NASA global atmospheric sampling program

The condensation-nuclei (Aitken particle) measuring system used in the NASA Global Atmospheric Sampling Program is described. Included in the paper is a description of the condensation-nuclei monitor sensor, the pressurization system, and the Pollack-counter calibration system used to support the CN measurement. The monitor has a measurement range to 1000 CN/cm cubed and a noise level equivalent to 5 CN/cm cubed at flight altitudes between 6 and 13 km.

Nyland, T. W.↗

Carbon Dioxide Flux Measurement System (CO2FLX) Instrument Handbook

The Southern Great Plains (SGP) carbon dioxide flux (CO2 flux) measurement systems provide half-hour average fluxes of CO2, H2O (latent heat), and sensible heat. The fluxes are obtained by the eddy covariance technique, which computes the flux as the mean product of the vertical wind component with CO2 and H2O densities, or estimated virtual temperature. A three-dimensional sonic anemometer is used to obtain the orthogonal wind components and the virtual (sonic) temperature. An infrared gas analyzer is used to obtain the CO2 and H2O densities. A separate sub-system also collects half-hour average measures of meteorological and soil variables from separate 4-m towers.

54 ENVIRONMENTAL SCIENCES↗

Analysis of the Rim Inertial Measuring System (RIMS)

Nonlinear equations of motion are derived for the rim inertial measuring system, which is mounted in a strapped down configuration on a carrier vehicle. The measurement and equations derived from angular rates and linear accelerations were interfaced with the dynamic model of a user defined carried vehicle. Two methods are presented for rate measurement, and the results of the nonlinear computer simulation are presented.

Joshi, S. M.↗

Blade Vibration Measurement System

The Phase I project successfully demonstrated that an advanced noncontacting stress measurement system (NSMS) could improve classification of blade vibration response in terms of mistuning and closely spaced modes. The Phase II work confirmed the microwave sensor design process, modified the sensor so it is compatible as an upgrade to existing NSMS, and improved and finalized the NSMS software. The result will be stand-alone radar/tip timing radar signal conditioning for current conventional NSMS users (as an upgrade) and new users. The hybrid system will use frequency data and relative mode vibration levels from the radar sensor to provide substantially superior capabilities over current blade-vibration measurement technology. This frequency data, coupled with a reduced number of tip timing probes, will result in a system capable of detecting complex blade vibrations that would confound traditional NSMS systems. The hardware and software package was validated on a compressor rig at Mechanical Solutions, Inc. (MSI). Finally, the hybrid radar/tip timing NSMS software package and associated sensor hardware will be installed for use in the NASA Glenn spin pit test facility.

Platt, Michael J.↗

Angle Measurement System (AMS) for Establishing Model Pitch and Roll Zero, and Performing Single Axis Angle Comparisons

The angle measurement system (AMS) developed at NASA Langley Research Center (LaRC) is a system for many uses. It was originally developed to check taper fits in the wind tunnel model support system. The system was further developed to measure simultaneous pitch and roll angles using 3 orthogonally mounted accelerometers (3-axis). This 3-axis arrangement is used as a transfer standard from the calibration standard to the wind tunnel facility. It is generally used to establish model pitch and roll zero and performs the in-situ calibration on model attitude devices. The AMS originally used a laptop computer running DOS based software but has recently been upgraded to operate in a windows environment. Other improvements have also been made to the software to enhance its accuracy and add features. This paper will discuss the accuracy and calibration methodologies used in this system and some of the features that have contributed to its popularity.

Crawford, Bradley L.↗

Performance Characterization of a Landmark Measurement System for ARRM Terrain Relative Navigation

This paper describes the landmark measurement system being developed for terrain relative navigation on NASAs Asteroid Redirect Robotic Mission (ARRM),and the results of a performance characterization study given realistic navigational and model errors. The system is called Retina, and is derived from the stereo-photoclinometry methods widely used on other small-body missions. The system is simulated using synthetic imagery of the asteroid surface and discussion is given on various algorithmic design choices. Unlike other missions, ARRMs Retina is the first planned autonomous use of these methods during the close-proximity and descent phase of the mission.

Guidance↗

Performance Characterization of a Landmark Measurement System for ARRM Terrain Relative Navigation

This paper describes the landmark measurement system being developed for terrain relative navigation on NASAs Asteroid Redirect Robotic Mission (ARRM),and the results of a performance characterization study given realistic navigational and model errors. The system is called Retina, and is derived from the stereophotoclinometry methods widely used on other small-body missions. The system is simulated using synthetic imagery of the asteroid surface and discussion is given on various algorithmic design choices. Unlike other missions, ARRMs Retina is the first planned autonomous use of these methods during the close-proximity and descent phase of the mission.

Navigation↗

An intercomparison of surface energy flux measurement systems used during FIFE 1987

During FIFE 1987, surface energy fluxes were measured at 22 flux sites by nine groups of scientists using different measuring systems. A rover Bowen ratio station was taken to 20 of the flux stations to serve as a reference for estimating the instrument-related differences. The rover system was installed within a few meters from the host instrument of a site. Using linear regression analysis, net radiation, Bowen ratio, and latent heat fluxes were compared between the rover measurements and the host measurements. The average differences in net radiation, Bowen ratio, and latent heat flux from different types of instruments can be up to 10, 30, and 20 percent, respectively. The Didcot net radiometer gave higher net radiation while the Swissteco type showed lower values, as compared to the corrected radiation energy balance system (REBS) model. The four-way components method and the Thornthwaite type give similar values to the REBS. The surface energy radiation balance systems type Bowen ratio systems exhibit slightly lower Bowen ratios and thus higher latent heat fluxes, compared to the arid zone evapotranspiration systems. Eddy correlation systems showed slightly lower latent heat flux in comparison to the Bowen ratio systems. It is recommended that users of the flux data take these differences into account.

Nie, D.↗

Pyroelectric detector development for the Radiation Measurement system

A new class of high detectivity pyroelectric detectors developed for optimization of the radiation measurement system within the framework of the Atmospheric Radiation Measurement program is described. These devices are intended to provide detectivities of up to about 10 exp 11 cm Hz exp 0.5/W with cooling to about 100 K required for the detector focal plane.

Hubbard, G. S.↗

Use of global positioning system measurements to determine geocentric coordinates and variations in Earth orientation

Geocentric tracking station coordinates and short-period Earth-orientation variations can be measured with Global Positioning System (GPS) measurements. Unless calibrated, geocentric coordinate errors and changes in Earth orientation can lead to significant deep-space tracking errors. Ground-based GPS estimates of daily and subdaily changes in Earth orientation presently show centimeter-level precision. Comparison between GPS-estimated Earth-rotation variations, which are the differences between Universal Time 1 and Universal Coordinated Time (UT1-UTC), and those calculated from ocean tide models suggests that observed subdaily variations in Earth rotation are dominated by oceanic tidal effects. Preliminary GPS estimates for the geocenter location (from a 3-week experiment) agree with independent satellite laser-ranging estimates to better than 10 cm. Covariance analysis predicts that temporal resolution of GPS estimates for Earth orientation and geocenter improves significantly when data collected from low Earth-orbiting satellites as well as from ground sites are combined. The low Earth GPS tracking data enhance the accuracy and resolution for measuring high-frequency global geodynamical signals over time scales of less than 1 day.

R P Malla↗

Miniature On-Board Angle of Attack Measurement System for Hypersonic Facilities

The most prevalent method of establishing model angle of attack (AoA) in hypersonic wind tunnel facilities is using an encoder in the model support system then calculating sting/balance deflections based on balance output. This method has been shown to be less accurate than on-board methods in subsonic and transonic facilities and preliminary indications, as compared to optical methods, show large discrepancies in a hypersonic facility as well. With improvements in Micro-Electro- Mechanical Systems (MEMS) accelerometer technology more accurate onboard AoA measurement systems are now available for the small models usually found in hypersonic research facilities.

Crawford, Bradley L.↗

Advanced one-dimensional optical strain measurement system, phase 4

An improved version of the speckle-shift strain measurement system was developed. The system uses a two-dimensional sensor array to maintain speckle correlation in the presence of large off-axis rigid body motions. A digital signal processor (DSP) is used to calculate strains at a rate near the RS-170 camera frame rate. Strain measurements were demonstrated on small diameter wires and fibers used in composite materials research. Accurate values of Young's modulus were measured on tungsten wires, and silicon carbide and sapphire fibers. This optical technique has measured surface strains at specimen temperatures above 750 C and has shown the potential for measurements at much higher temperatures.

Lant, Christian T.↗

Ka-band Phase Measurement System for SWOT Mission

The KaRIn (Ka-band radar interferometer) instrument for SWOT (surface water ocean topography) mission faces unique challenges in terms of phase stability and group delay stability requirements to achieve centimeter level accuracy for height measurements. Conventional altimetry assumes nadir point return and measures a single range. SWOT will require additional angle of arrival information to provide swath coverage. Errors in differential phase and common group delay can both act as primary sources of systematic errors in determining the height using interferometric data. The ground support equipment (GSE) necessary for the performance requirements verification gets a fraction of the error allocation from the instrument. A phase measurement system capable of measuring millidegrees and working with pulsed excitation is developed and the preliminary results are described in this paper.

Esteban-Fernandez, Daniel↗