NASA Tech Briefs, February 2006

Topics discussed include: Nearly Direct Measurement of Relative Permittivity; DCS-Neural-Network Program for Aircraft Control and Testing; Dielectric Heaters for Testing Spacecraft Nuclear Reactors; Using Doppler Shifts of GPS Signals To Measure Angular Speed; Monitoring Temperatures of Tires Using Luminescent Materials; Highly Efficient Multilayer Thermoelectric Devices; Very High-Speed Digital Video Capability for In-Flight Use; MMIC DHBT Common-Base Amplifier for 172 GHz; Modular, Microprocessor-Controlled Flash Lighting System; Generic Environment for Simulating Launch Operations; Modular Aero-Propulsion System Simulation; X-Windows Socket Widget Class; Infrastructure for Rapid Development of Java GUI Programs; Processing Raman Spectra of High-Pressure Hydrogen Flames; X-Windows Information Sharing Protocol Widget Class; Simulating Humans as Integral Parts of Spacecraft Missions; Analyzing Power Supply and Demand on the ISS; Polyimides From a-BPDA and Aromatic Diamines; Making Plant-Support Structures From Waste Plant Fiber; Large Deployable Reflectarray Antenna; Periodically Discharging, Gas-Coalescing Filter; Ion Milling On Steps for Fabrication of Nanowires; Neuro-Prosthetic Implants With Adjustable Electrode Arrays; Microfluidic Devices for Studying Biomolecular Interactions; Studying Functions of All Yeast Genes Simultaneously; Polarization Phase-Compensating Coats for Metallic Mirrors; Tunable-Bandwidth Filter System; Methodology for Designing Fault-Protection Software; and Ground-Based Localization of Mars Rovers.

Source record↗

Unravel lipid accumulation mechanism in oleaginous yeast through single cell systems biology study

Searching for alternative and clean energy is one of the most important tasks today. Our research aimed at finding the best living condition for certain types of oleaginous yeasts for efficient lipid production. We found that R. glutinis yeast cells has great variability in lipid production among cells while Y. lipolytica cells has similar oil production ability. We found some individual cells shows much higher level of oil production. In order to further study these cases, we employed a label-free chemical sensitive microscopy method call stimulated Raman scattering (SRS). With SRS, we could measure the lipid content in each cell. We combined SRS microscopy with microfluidic device so that we can isolate cells with high fat content. We also developed SRS imaging technique that has higher imaging speed, which is highly desirable for high throughput cell screening and sorting. Since these cells has similar genome, it must be the transcriptome caused their difference in oil production. We developed a single cell transcriptome sequencing method to study which genes are responsible for elevated oil production. These methods that are developed for this project can easily be applied for many other areas of research. For example, the single transcriptome can be used to study the transcriptomes of other cell types. The high-speed SRS microscopy techniques can be used to speed up chemical imaging for lablefree histology or imaging distribution of chemicals in tissues of live mice or in humans. The developed microfluidic platform can be used to sort other type of cells, e.g., white blood cells for diagnosis of cancer or other blood diseases.

09 BIOMASS FUELS↗

Wetting transition and fluid trapping in a microfluidic fracture

Immiscible fluid–fluid displacement in confined geometries is a fundamental process occurring in many natural phenomena and technological applications, from geological CO 2 sequestration to microfluidics. Due to the interactions between the fluids and the solid walls, fluid invasion undergoes a wetting transition from complete displacement at low displacement rates to leaving a film of the defending fluid on the confining surfaces at high displacement rates. While most real surfaces are rough, fundamental questions remain about the type of fluid–fluid displacement that can emerge in a confined, rough geometry. Here, we study immiscible displacement in a microfluidic device with a precisely controlled structured surface as an analogue for a rough fracture. We analyze the influence of the degree of surface roughness on the wetting transition and the formation of thin films of the defending liquid. We show experimentally, and rationalize theoretically, that roughness affects both the stability and dewetting dynamics of thin films, leading to distinct late-time morphologies of the undisplaced (trapped) fluid. Finally, we discuss the implications of our observations for geologic and technological applications.

42 ENGINEERING↗

Papers Based Electrochemical Biosensors: From Test Strips to Paper-Based Microfluidics

Papers based biosensors such as lateral flow test strips and paper-based microfluidic devices (or paperfluidics) are inexpensive, rapid, flexible, and easy-to-use analytical tools. An apparent trend in their detection is to interpret sensing results from qualitative assessment to quantitative determination. Electrochemical detection plays an important role in quantification. This review focuses on electrochemical (EC) detection enabled biosensors. The first part provides detailed examples in paper test strips. The second part gives an overview of paperfluidics engaging EC detections. The outlook and recommendation of future directions of EC enabled biosensors are discussed in the end.

Biosensors↗

Enriching Cations Using Electric Field Gradients Generated by Bipolar Electrodes in the Absence of Buffer

We discuss that ionic current gradients and corresponding electric field gradients formed at bipolar electrodes are useful for enriching cations up to ~350-fold at specific locations in microfluidic devices. The enrichment mechanism is determined by collecting current data, measuring solution conductivity, and by performing pH indicator experiments. These data reveal the dynamic nature of the enrichment mechanism. Specifically, they show the complex relationship between the ionic current gradients formed at the bipolar electrode and the extent of cation enrichment. Finally, we demonstrate cation enrichment is possible in buffer-free solutions containing up to 50.0 mM KCl. This finding is significant because it broadens the range of solutions in which membrane-free, electrochemical separations using bipolar electrodes can be performed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Digital Maskless Photolithographic Patterning of DNA-Functionalized Poly(ethylene glycol) Diacrylate Hydrogels with Visible Light Enabling Photodirected Release of Oligonucleotides

Soft biomaterials possessing structural hierarchy have growing applications in lab-on-chip devices, artificial tissues, and micromechanical and chemomechanical systems. The ability to integrate sets of biomolecules, specifically DNA, within hydrogel substrates at precise locations could offer the potential to form and modulate complex biochemical processes with DNA-based molecular switches in such materials and provide a means of creating dynamic spatial patterns, thus enabling spatiotemporal control of a wide array of reaction-diffusion phenomena prevalent in biological systems. In this paper, we develop a means of photopatterning two-dimensional DNA-functionalized poly(ethylene glycol) diacrylate (PEGDA) hydrogel architectures with an aim toward these applications. While PEGDA photopatterning methods are well-established for the fabrication of hydrogels, including those containing oligonucleotides, the photoinitiators typically used have significant crosstalk with many UV-photoswitchable chemistries including nitrobenzyl derivatives. We demonstrate the digital photopatterning of PEGDA-co-DNA hydrogels using a blue light-absorbing (470 nm peak) photoinitiator system and macromer comprised of camphorquinone, triethanolamine, and poly(ethylene glycol) diacrylate ($M$ n = 575) that minimizes absorption in the UV-A wavelength range commonly used to trigger photoswitchable chemistries. We demonstrate this method using digital maskless photolithography within microfluidic devices that allows for the reliable construction of multidomain structures. The method achieves feature resolutions as small as 25 μm, and the resulting materials allow for lateral isotropic bulk diffusion of short single-stranded (ss) DNA oligonucleotides. Finally, we show how the use of these photoinitiators allows for orthogonal control of photopolymerization and UV-photoscission of acrylate-modified DNA containing a 1-(2-nitrophenyl) ethyl spacer to selectively cleave DNA from regions of a PEGDA substrate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coupling between DNA replication, segregation, and the onset of constriction in Escherichia coli

Escherichia coli cell cycle features two critical cell-cycle checkpoints: initiation of replication and the onset of constriction. While the initiation of DNA replication has been extensively studied, it is less clear what triggers the onset of constriction and when exactly it occurs during the cell cycle. Here, using high-throughput fluorescence microscopy in microfluidic devices, we determine the timing for the onset of constriction relative to the replication cycle in different growth rates. Our single-cell data and modeling indicate that the initiation of constriction is coupled to replication-related processes in slow growth conditions. Furthermore, our data suggest that this coupling involves the mid-cell chromosome blocking the onset of constriction via some form of nucleoid occlusion occurring independently of SlmA and the Ter linkage proteins. This work highlights the coupling between replication and division cycles and brings up a new nucleoid mediated control mechanism in E. coli.

59 BASIC BIOLOGICAL SCIENCES↗

Cation-Specific Electrokinetic Separations Using Prussian Blue Intercalation Reactions

In this work, we report a new approach for forming ion depletion zones (IDZs) using intercalation reactions at an electrochemically controlled Prussian blue (PB) film. The experiments described here were performed using a microfluidic device, wherein a charged fluorophore in solution was used as a proxy to monitor IDZ formation. In the presence of K + , intercalation reactions proceed readily to form an IDZ, and thus enrich the fluorophore up to 37-fold. In the presence of the larger hydrated Li + or tetrabutylammonium (TBA + ) ions, however, ion intercalation proceeded less quickly than with K + . Slower ion intercalation resulted in a weaker IDZ and correspondingly lower enrichment factors of eight- and six-fold, respectively. These results are significant because they show that PB intercalation reactions selectively form an IDZ. Accordingly, we anticipate that these findings will lead to a better understanding and further interesting applications of intercalation materials like PB for efficient and selective enrichment and separations.

99 GENERAL AND MISCELLANEOUS↗

Multiparameter Screening on SlipChip Used for Nanoliter Protein Crystallization Combining Free Interface Diffusion and Microbatch Methods

This paper describes two SlipChip-based approaches to protein crystallization: a SlipChip-based free interface diffusion (FID) method and a SlipChip-based composite method that simultaneously performs microbatch and FID crystallization methods in a single device. The FID SlipChip was designed to screen multiple reagents, each at multiple diffusion equilibration times, and was validated by screening conditions for crystallization of two proteins, enoyl-CoA hydratase from Mycobacterium tuberculosis and dihydrofolate reductase/thymidylate synthase from Babesia bovis, against 48 different reagents at five different equilibration times each, consuming 12 {micro}L of each protein for a total of 480 experiments using three SlipChips. The composite SlipChip was designed to screen multiple reagents, each at multiple mixing ratios and multiple equilibration times, and was validated by screening conditions for crystallization of two proteins, enoyl-CoA hydratase from Mycobacterium tuberculosis and dihydrofolate reductase/thymidylate synthase from Babesia bovis. To prevent cross-contamination while keeping the solution in the neck channels for FID stable, the plates of the SlipChip were etched with a pattern of nanowells. This nanopattern was used to increase the contact angle of aqueous solutions on the surface of the silanized glass. The composite SlipChip increased the number of successful crystallization conditions and identified more conditions for crystallization than separate FID and microbatch screenings. Crystallization experiments were scaled up in well plates using conditions identified during the SlipChip screenings, and X-ray diffraction data were obtained to yield the protein structure of dihydrofolate reductase/thymidylate synthase at 1.95 {angstrom} resolution. This free-interface diffusion approach provides a convenient and high-throughput method of setting up gradients in microfluidic devices and may find additional applications in cell-based assays.

59 BASIC BIOLOGICAL SCIENCES↗

A microfluidic study of transient flow states in permeable media using fluorescent particle image velocimetry

Velocity fields in flow in permeable media are of great importance to many subsurface processes such as geologic storage of CO 2 , oil and gas extraction, and geothermal systems. Steady-state flow is characterized by velocity fields that do not change significantly over time. The flow field transitions to a new steady state once it experiences a disturbance such as a change in flow rate or in pressure gradient. This transition is often assumed to be instantaneous, which justifies the expression of constitutive relations as functions of instantaneous phase saturations. This work examines the evolution of velocity fields in a surrogate quasi-2D permeable medium using a microfluidic device, a microscopy system, and a high-speed camera. Tracer particles are injected into the medium along with DI water. The evolution of the velocity field is examined by tracing these particles in the captured images using the standard high-density particle image velocimetry algorithm founded on cross-correlation. The results suggest that the transition between steady states for an incompressible fluid takes a finite and non-negligible amount of time that is independent of the magnitude of the change in pressure gradient. The existence of transient states and the nature of the response during these states are readily interpreted by the principle of least action where flow gradually establishes an optimal configuration such that energy dissipation is 2 minimized. The findings provide evidence against the applicability of the assumption that flowing phases relax instantaneously to their steady states and, hence, against the accuracy of the classical multiphase extension of Darcy's law.

42 ENGINEERING↗

Robust Extraction Interface for Coupling Droplet-Based and Continuous Flow Microfluidics

Reliable and highly efficient extraction of droplets from oil to aqueous phase is key for downstream coupling with chemical separations and nonoptical detection methods such as amperometry and mass spectrometry. This paper presents an improved interface providing robust extraction for droplet-based poly(dimethylsiloxane) (PDMS) microfluidic devices. The extraction interface consists of an array of cylindrical posts with narrow apertures in between. The aqueous flow channel into which droplets coalesced was simply and selectively modified to be hydrophilic, while the continuous oil phase flow channel that contained encapsulated aqueous droplets retained a hydrophobic surface. The different surfaces on both sides of the extraction region form a highly stable liquid interface between the two immiscible phases, allowing rapid droplet transfer to the aqueous stream. Entire droplets could be completely extracted within broad ranges of aqueous and oil flow rates (0 - 1 and 0.1 - 1 uL/min, respectively). After extraction, the droplet contents could be transported electrophoretically or by pressure-driven flow to a monolithically integrated emitter for nano-electrospray ionization mass spectrometry (nanoESI-MS) analysis. This interface should be amenable to the separation and identification of droplet contents and on-line monitoring of in-droplet reactions.

Based↗

Time-lapse Fluorescence Imaging of Arabidopsis Root Growth with Rapid Manipulation of The Root Environment Using The RootChip

The root functions as the physical anchor of the plant and is the organ responsible for uptake of water and mineral nutrients such as nitrogen, phosphorus, sulfate and trace elements that plants acquire from the soil. If we want to develop sustainable approaches to producing high crop yield, we need to better understand how the root develops, takes up a wide spectrum of nutrients, and interacts with symbiotic and pathogenic organisms. To accomplish these goals, we need to be able to explore roots in microscopic detail over time periods ranging from minutes to days. We developed the RootChip, a polydimethylsiloxane (PDMS)- based microfluidic device, which allows us to grow and image roots from Arabidopsis seedlings while avoiding any physical stress to roots during preparation for imaging1 (Figure 1). The device contains a bifurcated channel structure featuring micromechanical valves to guide the fluid flow from solution inlets to each of the eight observation chambers2 . This perfusion system allows the root microenvironment to be controlled and modified with precision and speed. The volume of the chambers is approximately 400 nl, thus requiring only minimal amounts of test solution. Here we provide a detailed protocol for studying root biology on the RootChip using imaging-based approaches with real time resolution. Roots can be analyzed over several days using time lapse microscopy. Roots can be perfused with nutrient solutions or inhibitors, and up to eight seedlings can be analyzed in parallel. This system has the potential for a wide range of applications, including analysis of root growth in the presence or absence of chemicals, fluorescence-based analysis of gene expression, and the analysis of biosensors, e.g. FRET nanosensors3.

59 BASIC BIOLOGICAL SCIENCES↗

Dynamics and unsteady morphologies at ice interfaces driven by D 2 O–H 2 O exchange

The growth dynamics of D 2 O ice in liquid H 2 O in a microfluidic device were investigated between the melting points of D 2 O ice (3.8 °C) and H 2 O ice (0 °C). As the temperature was decreased at rates between 0.002 °C/s and 0.1 °C/s, the ice front advanced but retreated immediately upon cessation of cooling, regardless of the temperature. This is a consequence of the competition between diffusion of H 2 O into the D 2 O ice, which favors melting of the interface, and the driving force for growth supplied by cooling. Raman microscopy tracked H/D exchange across the solid H 2 O–solid D 2 O interface, with diffusion coefficients consistent with transport of intact H 2 O molecules at the D 2 O ice interface. At fixed temperatures below 3 °C, the D 2 O ice front melted continuously, but at temperatures near 0 °C a scalloped interface morphology appeared with convex and concave sections that cycled between growth and retreat. Finally, this behavior, not observed for D 2 O ice in contact with D 2 O liquid or H 2 O ice in contact with H 2 O liquid, reflects a complex set of cooperative phenomena, including H/D exchange across the solid–liquid interface, latent heat exchange, local thermal gradients, and the Gibbs–Thomson effect on the melting points of the convex and concave features.

54 ENVIRONMENTAL SCIENCES↗

Controlling matric potential in microfluidics to examine microbial dynamics in unsaturated porous media

The use of microfluidics for the study of soil microbial ecology is an emerging field. Most microfluidic studies of biological systems, however, have been performed under fully saturated conditions that are not representative of natural soil. Therefore, while microfluidics offer many unique capabilities that other methodologies cannot, they are not currently suited to address the effects of matric potential, an important variable defining the microbial moisture niche. Here, a methodology is presented that allows the user to control the aqueous conditions within microfluidic networks by manipulating matric potential using a hanging water column. The method relies on hydrophilic surface treatment of the microfluidic device using polyvinyl alcohol (PVA) and incorporating a bed of small pores at the network boundaries, which serve as a porous ceramic plate analogue (PPA). The method was validated on a simple capillary bundle and then on a more complex pore network. A water retention curve, exhibiting hysteresis, was generated for the pore network over a narrow matric potential range of 0 to – 5 kPa. Both the drainage and wetting curves were reproducible, as were the spatial configuration and the number of fragmented moisture niches in the pore network, particularly on the drainage curve. In contrast, the wetting curve exhibited greater variability in spatial configuration due to the “ink bottle effect,” where capillarity was interrupted by wider pore bodies. Ultimately, the methodology provides realistic pore-scale moisture conditions that can be easily manipulated and maintained, enabling new opportunities to explore soil biophysics and microbial biogeography in unsaturated porous media. As a brief example, images showing the localization of fluorescently tagged Pantoea sp. YR343 at −4.3 kPa are presented, highlighting bacterial distributions in water films and air-water interfaces.

59 BASIC BIOLOGICAL SCIENCES↗

Soft materials with recoverable shape factors from extreme distortion states

We present elastomeric polysiloxane nanocomposites with elongations of >5000% (more than 3× greater than any previously reported material) with excellent shape recovery. Highly deformable materials are desirable for the fabrication of stretchable implants and microfluidic devices. No crosslinking or domain formation is observed by a variety of analytical techniques, suggesting that their elastomeric behavior is caused by polymer chain entanglements.

36 MATERIALS SCIENCE↗

Liquid Letters

Abstract Using the interfacial jamming of cellulose nanocrystal (CNC) surfactants, a new concept, termed all‐liquid molding, is introduced to produce all‐liquid objects that retain the shape and details of the mold with high fidelity, yet remain all liquid and are responsive to external stimuli. This simple process, where the viscosity of the CNC dispersion can range from that of water to a crosslinked gel, opens tremendous opportunities for encapsulation, delivery systems, and unique microfluidic devices. The process described is generally applicable to any functionalized nanoparticles dispersed in one liquid and polymer ligands having complementary functionality dissolved in a second immiscible liquid. Such sculpted liquids retain all the characteristics of the liquids but retain shape indefinitely, very much like a solid, and provide a new platform for next‐generation soft materials.

Shi, Shaowei↗

Length scale selects directionality of droplets on vibrating pillar ratchet

Directional control of droplet motion at room temperature is of interest for applications such as microfluidic devices, self-cleaning coatings, and directional adhesives. Here, arrays of tilted pillars ranging in height from the nanoscale to the microscale are used as structural ratchets to directionally transport water at room temperature. Water droplets deposited on vibrating chips with a nanostructured ratchet move preferentially in the direction of the feature tilt while the opposite directionality is observed in the case of microstructured ratchets. This remarkable switch in directionality is consistent with changes in the contact angle hysteresis. To glean further insights into the length scale dependent asymmetric contact angle hysteresis, the contact lines formed by a nonvolatile room temperature ionic liquid placed onto the tilted pillar arrays were visualized and analyzed in situ in a scanning electron microscope. As a result, the ability to tune droplet directionality by merely changing the length scale of surface features all etched at the same tilt angle would be a versatile tool for manipulating multiphase flows and for selecting droplet directionality in other lap-on-chip applications.

42 ENGINEERING↗

Magnetic Quantum Dots Steer and Detach Microtubules From Kinesin‐Coated Surfaces

The microtubule (MT)‐kinesin system has been extensively studied because of its role in cellular processes, as well as its potential use for controllably transporting objects at the nanoscale. Thus, there is substantial interest in methods to evaluate MT properties, including bending radius and the binding energy of kinesin motor proteins to MT tracks. Current methods to identify these properties include optical tweezers, microfluidic devices, and magnetic fields. Here, the use of magnetic quantum dots (i.e., MagDots) is evaluated as a method to study MT‐kinesin interactions via applied magnetic forces. Magnetic fields are generated using a magnetic needle whose field gradient is quantified by finite element modeling (FEM). Magnetic force is applied to MagDot‐labeled MTs and demonstrated sufficient to steer and detach MTs from kinesin‐coated surfaces. Taking advantage of the dual‐functionality of MagDots, the magnetic force experienced by a single MagDot and the number of MagDots on MTs are determined. The total force exerted on MTs by MagDots is estimated to be ≈0.94–2.47 pN. This approach could potentially be used to interrogate MT properties and MT‐kinesin interactions, enhancing our biological understanding of this system and enabling further development of MT shuttles for nanotransport.