Search NASA⌕ Search

SEARCH · Search NASA

Results for “microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

{sup 6}He+{sup 12}C elastic scattering using a microscopic optical potential

The {sup 6}He+{sup 12}C elastic scattering data at beam energies of 3,38.3, and 41.6 MeV/nucleon are studied utilizing the microscopic optical potentials obtained by a double-folding procedure and also by using those inherent in the high-energy approximation. The calculated optical potentials are based on the neutron and proton density distributions of colliding nuclei established in an appropriate model for {sup 6}He and obtained from the electron scattering form factors for {sup 12}C. The depths of the real and imaginary parts of the microscopic optical potentials are considered as fitting parameters. At low energy the volume optical potentials reproduce sufficiently well the experimental data. At higher energies, generally, additional surface terms having the form of a derivative of the imaginary part of the microscopic optical potential are needed. The problem of ambiguity of adjusted optical potentials is resolved requiring the respective volume integrals to obey the determined dependence on the collision energy. Estimations of the Pauli blocking effects on the optical potentials and cross sections are also given and discussed. Conclusions on the role of the aforesaid effects and on the mechanism of the considered processes are made.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved microscopic-macroscopic approach incorporating the effects of continuum states

The Woods-Saxon-Strutinsky method (the microscopic-macroscopic method) combined with the Kruppa prescription for positive-energy levels, which is necessary to treat neutron-rich nuclei, is studied to clarify the reason for its success and to propose improvements for its shortcomings. The reason why the plateau condition is met for the Nilsson model but not for the Woods-Saxon model is understood in a new interpretation of the Strutinsky smoothing procedure as a low-pass filter. Essential features of the Kruppa level density is extracted in terms of the Thomas-Fermi approximation modified to describe spectra obtained from diagonalization in truncated oscillator bases. A method is proposed, which weakens the dependence on the smoothing width by applying the Strutinsky smoothing only to the deviations from a reference level density. The BCS equations are modified for the Kruppa spectrum, which is necessary to treat the pairing correlation properly in the presence of a continuum. The potential depth is adjusted for the consistency between the microscopic and macroscopic Fermi energies. It is shown, with these improvements, that the microscopic-macroscopic method is now capable to reliably calculate binding energies of nuclei far from stability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microscopic description of proton scattering at 295 MeV from Pb isotopes

Microscopic analysis of the recently reported 295-MeV-proton scattering data from Pb isotopes and {sup 58}Ni is presented within the framework of the Brueckner-Hartree-Fock theory. The effective interaction (g matrix) has been calculated using three Hamiltonians with Urbana v-14, Argonne v-18, and Ried93 internucleon potentials. The microscopic optical potential is calculated by folding the effective interactions over nucleon density distributions obtained in the relativistic mean field framework. The Argonne v-18 and Ried93 interactions have been used for the first time to calculate the nucleon-nucleus optical potential. The calculations reproduce the experiment well thus revalidating the use of microscopic optical potential in such analyses.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear shape evolution based on microscopic level densities

Here, by combining microscopically calculated level densities with the Metropolis walk method, we develop a consistent framework for treating the energy and angular-momentum dependence of the nuclear shape evolution in the fission process. For each nucleus under consideration, the level density is calculated microscopically for each of more than five million shapes with a recently developed combinatorial method. The method employs the same single-particle levels as those used for the extraction of the pairing and shell contributions to the macroscopic-microscopic deformation-energy surface. Containing no new parameters, the treatment is suitable for elucidating the energy dependence of the dynamics of warm nuclei on pairing and shell effects. It is illustrated for the fission fragment mass distribution for several uranium and plutonium isotopes of particular interest.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microscopic core-quasiparticle coupling model for spectroscopy of odd-mass nuclei

Predictions of the spectroscopic properties of low-lying states are critical for nuclear structure studies but are problematic for nuclei with an odd nucleon due to the interplay of the unpaired single particle with nuclear collective degrees of freedom. To predict the spectroscopic properties of odd-mass medium-heavy and heavy nuclei with a model that treats single-particle and collective degrees of freedom within the same microscopic framework. A microscopic core-quasiparticle coupling (CQC) model based on the covariant density functional theory is developed that contains the collective excitations of even-mass cores and spherical single-particle states of the odd nucleon as calculated from a quadrupole collective Hamiltonian combined with a constrained triaxial relativistic Hartree-Bogoliubov model. Additionally, predictions of the new model for excitation energies, kinematic and dynamic moments of inertia, and transition rates are shown to be in good agreement with results of low-lying spectroscopy measurements of the axially deformed odd-proton nucleus 159 Tb and the odd-neutron nucleus 157 Gd. A microscopic CQC model based on covariant density functional theory is developed for odd-mass nuclei and shown to give predictions that agree with measurements of two medium-heavy nuclei. Future studies with additional nuclei are planned.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Observation of a Microscopic Cascaded Contribution to the Fifth-Order Nonlinear Susceptibility

Typically, low-order nonlinearities are much stronger than high-order nonlinearities. In this Letter, we demonstrate a procedure by which strong high-order nonlinearities can be synthesized out of low-order nonlinearities. Our procedure involves the use of the previously largely overlooked process of microscopic cascading, which results from local-field effects. We have performed an experiment that allows us to distinguish the influence of microscopic cascading from the more-well-known process of macroscopic cascading, and we find conditions under which microscopic cascading can be the dominant effect. The ability to create a large high-order nonlinear response could prove useful for applications in quantum-information science that require the detection of the simultaneous presence of N entangled photons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microscopic theory of angular momentum distributions across the full range of fission fragments

Modern nuclear theory provides qualitative insights into the fundamental mechanisms of nuclear fission and is increasingly capable of making reliable quantitative predictions. Most quantities of interest pertain to the primary fission fragments, whose subsequent decay is typically modeled using statistical reaction models. Consequently, a key objective of fission theory is to inform these models by predicting the initial conditions of the primary fragments. Here, in this work, we employ a framework that combines joint angular momentum and particle number projection with time-dependent configuration mixing to calculate the angular momentum distributions of primary fragments. Focusing on the benchmark cases of neutron-induced fission of 235 U and 239 Pu , we predict—for the first time—microscopic angular momentum distributions for all fragments observed in experiments. Our results reveal a pronounced sawtooth pattern in the average angular momentum as a function of fragment mass, consistent with recent measurements. Additionally, we observe substantial variations in angular momentum distributions along isobaric chains, indicating that commonly used empirical formulas lack sufficient accuracy. We also quantify a strong correlation between the angular momentum and the deformation of the fragments at scission, and a weak correlation in the magnitude of the angular momentum between fragment partners. The generated data will enable estimation of the impact of microscopic distributions on fission spectra, paving the way toward fission modeling based on microscopic inputs.

Physics - Nuclear physics and radiation physics↗

Design and performance of an X-ray scanning microscope at the Hard X-ray Nanoprobe beamline of NSLS-II

A hard X-ray scanning microscope installed at the Hard X-ray Nanoprobe beamline of the National Synchrotron Light Source II has been designed, constructed and commissioned. The microscope relies on a compact, high stiffness, low heat dissipation approach and utilizes two types of nanofocusing optics. It is capable of imaging with ~15 nm × 15 nm spatial resolution using multilayer Laue lenses and 25 nm × 26 nm resolution using zone plates. Fluorescence, diffraction, absorption, differential phase contrast, ptychography and tomography are available as experimental techniques. The microscope is also equipped with a temperature regulation system which allows the temperature of a sample to be varied in the range between 90 K and 1000 K. The constructed instrument is open for general users and offers its capabilities to the material science, battery research and bioscience communities.

36 MATERIALS SCIENCE↗

Design-to-Deployment Continuum Platform for Microscopes and Computing Ecosystems

Science ecosystems with networked computing systems and physical instruments are increasingly being deployed with a goal to achieve the productivity promised by AI-supported remote automation. In support of these efforts, the virtual infrastructure twins (VITs) have been successfully utilized to develop the orchestration codes for these ecosystems without requiring physical access to expensive instruments, such as electron microscopes. Currently, the utility of such a VIT is severely limited by the computing capacity and capability of the computing system used as its host. Furthermore, codes developed on the VIT typically need to be transferred and refactored for production use, particularly, on high-performance systems with accelerators. In response, we develop a design-to-deployment continuum platform wherein a VIT runs natively on the ecosystem's own computing system, and thereby facilitates the continual in-situ testing and transition of codes for production use. Here, we describe the development and testing of software for remote microscope steering and GPU-based image reconstruction using this platform on a multi-GPU computing system networked to Nion microscopes. We demonstrate a continual transition of steering and reconstruction codes developed under VIT platform to production ecosystem deployment.

Al-Najjar, Anees [Oak Ridge National Laboratory (O↗

Mask-side Hyper-NA EUV imaging on the SHARP microscope

Hyper-NA, the prospective successor to high-numerical aperture (NA) extreme ultraviolet lithography (EUVL) could be inserted soon after 2030. Hyper-NA poses a number of challenges, including reduced depth of focus, amplified mask three-dimensional effects, and increased mask-side angular range. A Hyper-NA capable extreme ultraviolet (EUV) mask-imaging tool can address these challenges and accelerate research and development toward Hyper-NA. The Sharp High-Numerical Aperture Actinic Reticle Review Project (SHARP) EUV mask microscope is supporting mask-side high-NA imaging since 2015. Implementing mask-side Hyper-NA imaging in 2024 enables research and development toward the corresponding nodes of EUVL. Hyper-NA zoneplates at 0.75 4x/8x NA with a 6.7-deg chief ray angle and 0.85 4x/8x NA with a 7.4-deg chief ray angle are added to the SHARP microscope. Imaging at mask-side Hyper-NA is demonstrated. Imaging of 5-nm half-pitch (wafer scale) horizontal lines and spaces is demonstrated using dipole illumination. Imaging of 5-nm half-pitch (wafer scale) vertical lines and spaces is demonstrated using frequency-doubled imaging of 40-nm hp (mask scale) lines and spaces. Normalized image log slope (NILS) and modulation of Hyper-NA image data match closely to simulations for horizontal lines and spaces. A reduction in NILS of 0.3 or less is observed for vertical lines and spaces in the two-beam imaging regime. Through-focus image data are discussed, comparing different dipole sources and mask-side NAs. Mask-side Hyper-NA photomask imaging has been implemented and demonstrated on the SHARP microscope and is now available to users of the instrument.

Benk, Markus↗

Calibration, modeling, parameterization, and verification of the instrument transfer function of an interferometric microscope

Interferometric microscopes are used to measure surface roughness, from which the computed power spectral density function can be used to extract bandwidth-limited values of the various surface properties, such as root-mean-square (rms) height and slope errors. Measurements with a microscope equipped with different objectives that have an overlapping spatial frequency range usually give different rms results over the common frequency bandwidth. This is a result of different instrument transfer functions (ITFs) that attenuate spatial frequencies by different amounts over the overlapping range. We report on the use of binary pseudo-random array (BPRA) standards to characterize the ITF of an interferometric microscope with the various objectives. We use a simple model of a 1D binary Results show that the spectrum for an undersampled array is a cosine function, rather than a straight line, constant white noise spectrum. We have an analytical model of the ITF that includes the effects of an obscured aperture and defocus, in addition to the usual parameters of numerical aperture, wavelength, and sampling period. In addition, the model includes the effect of aliasing of spatial frequency components beyond the Nyquist back into the sub-Nyquist region. We compare the model PSD predictions to the measurements performed with different objectives. Departures of the measured PSDs from the model predictions indicate that there are higher-order ITF corrections yet to be identified and included in the model.

Takacs, PZ↗

Binding energies of even-even superheavy nuclei in a semi-microscopic approach

The structure of some even-even superheavy nuclei with the proton number Z = 98-120 is studied using a semi-microscopic but not self-consistent model. The macroscopic energy part is obtained from the Skyrme nucleon-nucleon interaction in the semi-classical extended Thomas-Fermi approach. A simple but accurate method is derived for calculating the direct part of the Coulomb energy. The microscopic shell plus pairing energy corrections are calculated from the traditional Strutinsky method. Within this semi-microscopic approach, the total energy curves with the quadrupole deformation of the studied superheavy nuclei were calculated. The same approach features the well known {sup 208}Pb or {sup 238}U nuclei. For each nucleus the model predictions for the binding energy, the deformation parameters, the half-density radii and comparison with other theoretical models are made. The calculated binding energies are in good agreement with the available experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Elemental and topographical imaging of microscopic variations in deposition on NSTX-U and DIII-D samples

Tokamak plasma facing components have surface roughness that can cause microscopic spatial variations in erosion and deposition and hence influence material migration, erosion lifetime, dust and tritium accumulation, and plasma contamination. However high spatial resolution measurements of deposition on the scale of the surface roughness have been lacking to date. We will present elemental images of graphite samples from NSTX-U and DIII-D DiMES experiments performed with a Scanning Auger Microprobe at sub-micron resolution that show strong microscopic variations in deposition and correlate this with 3D topographical maps of surface irregularities. The NSTX-U samples were boronized and exposed to deuterium plasmas and the DiMES samples had localized Al and W films and were exposed to dedicated helium plasmas. Topographical maps of the samples were performed with a 3D confocal optical microscope and compared to the elemental deposition pattern. The results revealed localized deposition concentrated in areas shadowed from the ion flux, incident in a direction calculated (for the DiMES case) by taking account of the magnetic pre-sheath.

Surface analysis↗

Elemental and topographical imaging of microscopic variations in deposition on NSTX-U and DIII-D samples2

Abstract: Tokamak plasma facing components have surface roughness that can cause microscopic spatial variations in erosion and deposition and hence influence material migration, erosion lifetime, dust and tritium accumulation, and plasma contamination. However high spatial resolution measurements of deposition on the scale of the surface roughness have been lacking to date. We will present elemental images of graphite samples from NSTX-U and DIII-D DiMES experiments performed with a Scanning Auger Microprobe at sub-micron resolution that show strong microscopic variations in deposition and correlate this with 3D topographical maps of surface irregularities. The NSTX-U samples were boronized and exposed to deuterium plasmas and the DiMES samples had localized Al and W films and were exposed to dedicated helium plasmas. Topographical maps of the samples were performed with a 3D confocal optical microscope and compared to the elemental deposition pattern. The results revealed localized deposition concentrated in areas shadowed from the ion flux, incident in a direction calculated (for the DiMES case) by taking account of the magnetic pre-sheath.

Erosion, Deposition, NSTX-U, DIMES, Plasma-Materia↗

Tailored approach to study Legionella infection using a lattice light sheet microscope (LLSM)

Legionella is a genus of ubiquitous environmental pathogens found in freshwater systems, moist soil, and composted materials. More than four decades of Legionella research has provided important insights into Legionella pathogenesis. Although standard commercial microscopes have led to significant advances in understanding Legionella pathogenesis, great potential exists in the deployment of more advanced imaging techniques to provide additional insights. The lattice light sheet microscope (LLSM) is a recently developed microscope for 4D live cell imaging with high resolution and minimum photo-damage. We built a LLSM with an improved version for the optical layout with two path-stretching mirror sets and a novel reconfigurable galvanometer scanner ( RGS ) module to improve the reproducibility and reliability of the alignment and maintenance of the LLSM. We commissioned this LLSM to study Legionella pneumophila infection with a tailored workflow designed over instrumentation, experiments, and data processing methods. Our results indicate that Legionella pneumophila infection is correlated with a series of morphological signatures such as smoothness, migration pattern and polarity both statistically and dynamically. Our work demonstrates the benefits of using LLSM for studying long-term questions in bacterial infection. Our free-for-use modifications and workflow designs on the use of LLSM system contributes to the adoption and promotion of the state-of-the-art LLSM technology for both academic and commercial applications.

59 BASIC BIOLOGICAL SCIENCES↗

Quantitative Imaging with a Mobile Phone Microscope

Use of optical imaging for medical and scientific applications requires accurate quantification of features such as object size, color, and brightness. High pixel density cameras available on modern mobile phones have made photography simple and convenient for consumer applications; however, the camera hardware and software that enables this simplicity can present a barrier to accurate quantification of image data. This issue is exacerbated by automated settings, proprietary image processing algorithms, rapid phone evolution, and the diversity of manufacturers. If mobile phone cameras are to live up to their potential to increase access to healthcare in low-resource settings, limitations of mobile phone–based imaging must be fully understood and addressed with procedures that minimize their effects on image quantification. Here we focus on microscopic optical imaging using a custom mobile phone microscope that is compatible with phones from multiple manufacturers. We demonstrate that quantitative microscopy with micron-scale spatial resolution can be carried out with multiple phones and that image linearity, distortion, and color can be corrected as needed. Using all versions of the iPhone and a selection of Android phones released between 2007 and 2012, we show that phones with greater than 5 MP are capable of nearly diffraction-limited resolution over a broad range of magnifications, including those relevant for single cell imaging. We find that automatic focus, exposure, and color gain standard on mobile phones can degrade image resolution and reduce accuracy of color capture if uncorrected, and we devise procedures to avoid these barriers to quantitative imaging. By accommodating the differences between mobile phone cameras and the scientific cameras, mobile phone microscopes can be reliably used to increase access to quantitative imaging for a variety of medical and scientific applications.

59 BASIC BIOLOGICAL SCIENCES↗

A self-driving microscope and the Atomic Forge

The electron microscope predates the transistor and the charge-coupled device (CCD). The opportunity to integrate these advancements into the electron microscope was seized and revolutionized in the modern (scanning) transmission electron microscope (STEM). Real-time analysis became possible and is now routine. Consider the efforts one would have to undertake to perform a Fourier transform in the days when images were acquired by exposing photographic plates. Indeed, it was real-time data analysis that enabled the measurement and correction of aberrations in modern instrumentation.1 What are the next opportunities on the horizon for the STEM?

36 MATERIALS SCIENCE↗

On-axis 3D microscope for x-ray beamlines at NSLS-II

A series of versatile on-axis X-ray microscopes with large working distances, high resolution and large magnification have been developed at NSLS-II [1,2]. These microscopes use reflective optics, which minimizes dispersion, and allows imaging from Ultraviolet (UV) [3] to Infrared (IR) with specifically chosen objective components (coatings, etc.). Additional customizations can be implemented to provide dual-view with high/low magnification [4], 3-D imaging, long working range, as well as ruby fluorescence measurement for high pressure samples. In this publication we discuss 3D imaging enhancement to on-axis microscopes.

47 OTHER INSTRUMENTATION↗