Search NASA⌕ Search

SEARCH · Search NASA

Results for “miniaturization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Miniature sheathed thermocouples for turbine blade temperature measurement

An investigation was made of sheathed thermocouples for turbine blade temperature measurements. Tests were performed on the Chromel-Alumel sheathed thermocouples with both two-wire and single-wire configurations. Sheath diameters ranged from 0.25 to 0.76 mm, and temperatures ranged from 1080 to 1250 K. Both steady-state and thermal cycling tests were performed for times up to 450 hr. Special-order and commercial-grade thermocouples were tested. The tests showed that special-order single-wire sheathed thermocouples can be obtained that are reliable and accurate with diameters as small as 0.25 mm. However, all samples of 0.25-mm-diameter sheathed commercial-grade two-wire and single-wire thermocouples that were tested showed unacceptable drift rates for long-duration engine testing programs. The drift rates were about 1 percent in 10 hr. A thermocouple drift test is recommended in addition to the normal acceptance tests in order to select reliable miniature sheathed thermocouples for turbine blade applications.

Holanda, R.↗

Miniature multichannel biotelemeter system

A miniature multichannel biotelemeter system is described. The system includes a transmitter where signals from different sources are sampled to produce a wavetrain of pulses. The transmitter also separates signals by sync pulses. The pulses amplitude modulate a radio frequency carrier which is received at a receiver unit. There the sync pulses are detected by a demultiplexer which routes the pulses from each different source to a separate output channel where the pulses are used to reconstruct the signals from the particular source.

Carraway, J. B.↗

A magnetic field measurement technique using a miniature transducer

The development, fabrication, and application of a magnetometer are described. The magnetometer has a miniature transducer and is capable of automatic scanning. The magnetometer described here is capable of detecting static magnetic fields as low as 1.6 A/m and its transducer has an active area 0.64 mm by 0.76 mm. Thin and rugged, the transducer uses wire, 0.05 mm in diameter, which is plated with a magnetic film, enabling measurement of transverse magnetic fields as close as 0.08 mm from a surface. The magnetometer, which is simple to operate and has a fast response, uses an inexpensive clip-on milliammeter (commonly found in most laboratories) for driving and processing the electrical signals and readout. A specially designed transducer holding mechanism replaces the XY recorder ink pen; this mechanism provides the basis for an automatic scanning technique. The instrument has been applied to the measurements of magnetic fields arising from remanent magnetization in experimental plated-wire memory planes and regions of magnetic activity in geological rock specimens.

Fales, C. L., Jr.↗

A miniature high voltage plasma interaction flight experiment - Project MINX

A miniature high-voltage array was fabricated, incorporating the multi-junction edge illuminated (MJC) cell technique. The array consists of 32 2x2.2 cm MJCs, series connected, capable of 1600 V open circuit at 1 AMO and 1.2 mA short circuit. A solid state, high-voltage relay is connected across each 4-cell subgroup of the array. It was built to test plasma current drain on space systems using high voltage as might occur when a high-voltage solar array is operated from low to synchronous orbit.

Riley, T. J.↗

Miniature load cell instrumentation for finite deformation biaxial testing of elastomers

Accuracy of biaxial test equipment to examine the nonlinear mechanical behavior of thin sheet specimens of elastomeric materials has been hampered by lack of precise determination of the force distribution along the sides of the specimen. It has been necessary to use an effective width established by approximate means to obtain the stress from the overall force applied along the edges. To avoid this experimental difficulty, individual miniature proof-ring load cells utilizing semiconductor strain gages have been developed and applied to the support hooks for the thin sheet specimens. Typical results are shown for time-dependent stress distributions for all degrees of biaxiality. An accurate evaluation of the effective specimen width is now possible.

Arenz, R. J.↗

Miniature probes for use in gas turbine testing

Several examples of miniature probes (null type as well as fixed position) are presented which have proved useful in aircraft and space power systems component testing and are applicable to automotive gas turbine testing. These probes are used to determine component or system performance from the measurement of gas temperature as well as total and static pressure, and flow direction. Detailed drawings of the sensors are presented along with experimental data covering the flow characteristics over the range of intended use.

Glawe, G. E.↗

Feasibility of miniaturized instrumentation of the inflatable sphere for temperature, pressure and acceleration measurement

The feasibility of instrumenting the inflatable passive sphere (presently used to provide upper atmosphere density measurements) with miniaturized thermistors, pressure transducers, and accelerometers was analyzed. Data from the sensors must be transmitted by an onboard telemetry system to a ground receiving station. To assure a sufficiently slow fall velocity for the sphere the additional mass of the sensor and telemetry hardware must be less than 100 grams. Other constraints that must be satisfied by the sensor and telemetry systems include the ability to withstand a 150 g launch acceleration, the ability to function in both high and low temperature and pressure environments and be sufficiently small to be packaged within the body of a 3.81 cm diameter dart. A differential transducer that will measure the difference between ambient and internal sphere pressures is recommended. The application of each type of measurement relative to its ability to monitor sphere malfunction and to provide additional meteorological data is considered.

Luers, J. K.↗

Miniature probe for transonic flow direction measurements

A miniature probe is developed for measuring flow direction in one plane as well as stagnation pressure in the boundary layer and near wake of a transonic airfoil. The probe tip geometry and calibration curves are given, along with near wake survey data obtained for a supercritical airfoil. The advantages of the probe are ruggedness, ease of fabrication, ability to measure flow direction at a point, and insensitivity to out-of-plane velocity components.

Spaid, F. W.↗

Miniature probes for use in gas turbine testing

Because of space limitations and system complexity in many applications associated with gas turbine testing, extremely small flow measuring probes have sometimes been required. This paper presents several examples of these miniature probes - null type as well as fixed position - which have proved useful in aircraft and space power systems component testing and are applicable to automotive gas turbine testing. These probes are used to determine component or system performance from the measurement of gas temperature as well as total and static pressure, and flow direction. Detailed drawings of the sensors are presented along with experimental data covering the flow characteristics over the range of intended use.

Glawe, G. E.↗

Evaluation of the gravity independent miniature analytical system

The miniature fast analyzer is an automated, analytical instrument developed for potential use for biochemical analyses conducted in space flight. The gravity independent fast analyzer system is described which consists of a 17 place rotor type spectrophotometer and computerized data acquisition system weighing only 30 pounds and occupying a volume of 1 cubic foot.

Wallace, L. D.↗

A miniaturized pointing mount for Spacelab missions

A Miniaturized Pointing Mount (MPM) for Spacelab missions is defined and simulation results are described. This mount is proposed to complement the Spacelab Instrument Pointing System (IPS). It uses the same mount isolator concept as the Spacelab IPS but is much more efficient and economical for the accommodation of small shuttle payloads. The MPM is built from star tracker assemblies left over from the Apollo Telescope Mount program thereby assuring low cost and development risk. Simulation results indicate a high level of instrument stability can be expected. The short development time of the MPM would permit it to serve as a precursor to the Spacelab IPS for verifying critical new concepts such as the mount isolation and hold down mechanisms.

Fritz, C. G.↗

Performance of some miniature pressure transducers subjected to high rotational speeds and centripetal accelerations

The performance characteristics of several miniature pressure transducers were determined at centripetal accelerations up to 11,200 g's at a rotational speed of 23,000 rpm. The variation in centripetal acceleration was produced by changing radial position of the transducer relative to the center of rotation. Residual zero outputs and transducer sensitivities were determined at 23,000 rpm and compared with those determined at 0 rpm. The actual pressures at the various transducer locations differ from the center line impressed pressures due to a rotational effect. Corrections for this effect were made. A brief description of the test apparatus is included.

Minkin, H. L.↗

Miniature biaxial strain transducer

A reusable miniature strain transducer for use in the measurement of static or quasi-static, high level, biaxial strain on the surface of test specimens or structures was studied. Two cantilever arms, constructed by machining the material to appropriate flexibility, are self-aligning and constitute the transducing elements of the device. Used in conjunction with strain gages, the device enables testing beyond normal gage limits for high strains and number of load cycles. The device does not require conversion computations since the electrical output of the strain gages is directly proportional to the strain measured.

Hoffman, I. S.↗

The technology of miniature acoustic element arrays

Various aspects of miniature element array construction are discussed. Some initial results on optimization of lateral resolution with a special focusing technique in linear array design is presented, together with the constructional details. Furthermore the construction of a catheter tip array is treated in detail.

Bom, N.↗

Miniature drag-force anemometer

A miniature drag-force anemometer is described which is capable of measuring dynamic velocity head and flow direction. The anemometer consists of a silicon cantilever beam 2.5 mm long, 1.5 mm wide, and 0.25 mm thick with an integrated diffused strain-gage bridge, located at the base of the beam, as the force measuring element. The dynamics of the beam are like those of a second-order system with a natural frequency of about 42 kHz and a damping coefficient of 0.007. The anemometer can be used in both forward and reversed flow. Measured flow characteristics up to Mach 0.6 are presented along with application examples including turbulence measurements.

Krause, L. N.↗

Low cost miniature data collection platform

The development of the RF elements of a telecommunications package involved detailed study and analysis of concepts and techniques followed by laboratory testing and evaluation of designs. The design goals for a complete telecommunications package excluding antenna were a total weight of 300 grams, in a total volume of 400 cu cm with a capability of unattended operation for a period of six months. Of utmost importance is extremely low cost when produced in lots of 10,000. Early in the program it became apparent that a single Miniature Data Collection Platform would not satisfy all users. A single high efficiency system would not satisfy a user who had available a large battery capacity but required a low cost system. Conversely, the low cost system would not satisfy the end user who had a very limited battery capacity. A system design to satisfy these varied requirements was implemented by designing several versions of the system building blocks and then constructing three systems from these building blocks.

Source record↗

Test and development of inflatable spheres instrumented with miniaturized thermistors, accelerometers and pressure transducers

Instrumentation was developed for the high altitude inflatable sphere to measure its skin temperature, acceleration and internal pressure. The sphere without instrumentation has routinely been used over the past 10 years to provide measurements of winds, density, temperature and pressure between 100 Km and 30 Km altitude. With the miniaturized instrumentation package onboard, the system offers the potential for providing meteorological information as well as a better understanding of sphere performance and dynamics during its descent. Of the six launches of instrumented spheres only one provided telemetry data. However, many of the objectives of the program were achieved.

Luers, J. K.↗

Miniature drag force anemometer

A miniature drag force anemometer is described which is capable of measuring dynamic velocity head and flow direction. The anemometer consists of a silicon cantilevered beam 2.5 mm long, 1.5 mm wide, and 0.25 mm thick with an integrated diffused strain gage bridge, located at the base of the beam, as the force measuring element. The dynamics of the beam are like that of a second order system with a natural frequency of about 42 kHz and a damping coefficient of 0.007. The anemometer can be used in both forward and reversed flow. Measured flow characteristics up to Mach 0.6 are presented along with application examples including turbulence measurements.

Krause, L. N.↗