Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

AN ARECIBO SEARCH FOR PULSARS AND TRANSIENT SOURCES IN M33

We report on a systematic and sensitive search for pulsars and transient sources in the nearby spiral galaxy M33, conducted at 1.4 GHz with the Arecibo telescope's seven-beam receiver system, ALFA. Data were searched for both periodic and aperiodic sources, up to 1000 pc cm{sup -3} in dispersion measure and on timescales from {approx}50 {mu}s to several seconds. The galaxy was sampled with 12 ALFA pointings, or 84 pixels in total, each of which was searched for 2-3 hr. We describe the observations, search methodologies, and analysis strategies applicable to multibeam systems, and comment on the data quality and statistics of spurious events that arise due to radio frequency interference. While these searches have not led to any conclusive signals of periodic or transient nature that originate in the galaxy, they illustrate some of the underlying challenges and difficulties in such searches and the efficacy of simultaneous multiple beams in the analysis of search output. The implied limits are {approx}<5 {mu}Jy Mpc{sup 2} in luminosity (at 1400 MHz) for periodic sources in M33 with duty cycles {approx}<5%. For short-duration transient signals (with pulse widths {approx}<100 {mu}s ), the limiting peak flux density is 100 mJy, which would correspond to a 5{sigma} detection of bright giant pulses ({approx}20 kJy) from Crab-like pulsars if located at the distance of M33. We discuss the implications of our null results for various source populations within the galaxy and comment on the future prospects to conduct even more sensitive searches with the upcoming next-generation instruments including the Square Kilometer Array and its pathfinders.

79 ASTRONOMY AND ASTROPHYSICS↗

Beamlet based direct aperture optimization for MERT using a photon MLC

Purpose: A beamlet based direct aperture optimization (DAO) for modulated electron radiotherapy (MERT) using photon multileaf collimator (pMLC) shaped electron fields is developed and investigated. Methods: The Swiss Monte Carlo Plan (SMCP) allows the calculation of dose distributions for pMLC shaped electron beams. SMCP is interfaced with the Eclipse TPS (Varian Medical Systems, Palo Alto, CA) which can thus be included into the inverse treatment planning process for MERT. This process starts with the import of a CT-scan into Eclipse, the contouring of the target and the organs at risk (OARs), and the choice of the initial electron beam directions. For each electron beam, the number of apertures, their energy, and initial shape are defined. Furthermore, the DAO requires dose–volume constraints for the structures contoured. In order to carry out the DAO efficiently, the initial electron beams are divided into a grid of beamlets. For each of those, the dose distribution is precalculated using a modified electron beam model, resulting in a dose list for each beamlet and energy. Then the DAO is carried out, leading to a set of optimal apertures and corresponding weights. These optimal apertures are now converted into pMLC shaped segments and the dose calculation for each segment is performed. For these dose distributions, a weight optimization process is launched in order to minimize the differences between the dose distribution using the optimal apertures and the pMLC segments. Finally, a deliverable dose distribution for the MERT plan is obtained and loaded back into Eclipse for evaluation. For an idealized water phantom geometry, a MERT treatment plan is created and compared to the plan obtained using a previously developed forward planning strategy. Further, MERT treatment plans for three clinical situations (breast, chest wall, and parotid metastasis of a squamous cell skin carcinoma) are created using the developed inverse planning strategy. The MERT plans are compared to clinical standard treatment plans using photon beams and the differences between the optimal and the deliverable dose distributions are determined. Results: For the idealized water phantom geometry, the inversely optimized MERT plan is able to obtain the same PTV coverage, but with an improved OAR sparing compared to the forwardly optimized plan. Regarding the right-sided breast case, the MERT plan is able to reduce the lung volume receiving more than 30% of the prescribed dose and the mean lung dose compared to the standard plan. However, the standard plan leads to a better homogeneity within the CTV. The results for the left-sided thorax wall are similar but also the dose to the heart is reduced comparing MERT to the standard treatment plan. For the parotid case, MERT leads to lower doses for almost all OARs but to a less homogeneous dose distribution for the PTV when compared to a standard plan. For all cases, the weight optimization successfully minimized the differences between the optimal and the deliverable dose distribution. Conclusions: A beamlet based DAO using multiple beam angles is implemented and successfully tested for an idealized water phantom geometry and clinical situations.

60 APPLIED LIFE SCIENCES↗

SU-E-J-203: Investigation of 1.5T Magnetic Field Dose Effects On Organs of Different Density

Purpose: For the combined 1.5T/6MV MRI-linac system, the perpendicular magnetic field to the radiation beam results in altered radiation dose distributions. This Monte Carlo study investigates the change in dose at interfaces for common organs neighboring soft tissue. Methods: MCNP6 was used to simulate the effects of a 1.5T magnetic field when irradiating tissues with a 6 MV beam. The geometries used in this study were not necessarily anatomically representative in size in order to directly compare quantitative dose effects for each tissue at the same depths. For this purpose, a 512 cm{sup 3} cubic material was positioned at the center of a 2744 cm{sup 3} cubic soft tissue material phantom. The following tissue materials and their densities were used in this study: lung (0.296 g/cm{sup 3}), fat (0.95), spinal cord (1.038), soft tissue (1.04), muscle (1.05), eye (1.076), trabecular bone (1.40), and cortical bone (1.85). Results: The addition of a 1.5T magnetic field caused dose changes of +46.5%, +2.4%, −0.9%, −0.8%, −1.5%, −6.5%, and −8.8% at the entrance interface between soft tissue and lung, fat, spinal cord, muscle, eye, trabecular bone, and cortical bone tissues respectively. Dose changes of −39.4%, −4.1%, −0.8%, −0.8%, +0.5%, +6.7%, and +10.9% were observed at the second interface between the same tissues respectively and soft tissue. On average, the build-up distance was reduced by 0.6 cm, and a dose increase of 62.7% was observed at the exit interface between soft tissue and air of the entire phantom. Conclusion: The greatest changes in dose were observed at interfaces containing lung and bone tissues. Due to the prevalence and proximity of bony anatomy to soft tissues throughout the human body, these results encourage further examination of these tissues with anatomically representative geometries using multiple beam configurations for safe treatment using the MRI-linac system.

60 APPLIED LIFE SCIENCES↗

Advanced Rainbow Solar Photovoltaic Arrays

Photovoltaic arrays of the rainbow type, equipped with light-concentrator and spectral-beam-splitter optics, have been investigated in a continuing effort to develop lightweight, high-efficiency solar electric power sources. This investigation has contributed to a revival of the concept of the rainbow photovoltaic array, which originated in the 1950s but proved unrealistic at that time because the selection of solar photovoltaic cells was too limited. Advances in the art of photovoltaic cells since that time have rendered the concept more realistic, thereby prompting the present development effort. A rainbow photovoltaic array comprises side-by-side strings of series-connected photovoltaic cells. The cells in each string have the same bandgap, which differs from the bandgaps of the other strings. Hence, each string operates most efficiently in a unique wavelength band determined by its bandgap. To obtain maximum energy-conversion efficiency and to minimize the size and weight of the array for a given sunlight input aperture, the sunlight incident on the aperture is concentrated, then spectrally dispersed onto the photovoltaic array plane, whereon each string of cells is positioned to intercept the light in its wavelength band of most efficient operation. The number of cells in each string is chosen so that the output potentials of all the strings are the same; this makes it possible to connect the strings together in parallel to maximize the output current of the array. According to the original rainbow photovoltaic concept, the concentrated sunlight was to be split into multiple beams by use of an array of dichroic filters designed so that each beam would contain light in one of the desired wavelength bands. The concept has since been modified to provide for dispersion of the spectrum by use of adjacent prisms. A proposal for an advanced version calls for a unitary concentrator/ spectral-beam-splitter optic in the form of a parabolic curved Fresnel-like prism array with panels of photovoltaic cells on two sides (see figure). The surface supporting the solar cells can be adjusted in length or angle to accommodate the incident spectral pattern. An unoptimized prototype assembly containing ten adjacent prisms and three photovoltaic cells with different bandgaps (InGaP2, GaAs, and InGaAs) was constructed to demonstrate feasibility. The actual array will consist of a lightweight thin-film silicon layer of prisms curved into a parabolic shape. In an initial test under illumination of 1 sun at zero airmass, the energy-conversion efficiency of the assembly was found to be 20 percent. Further analysis of the data from this test led to a projected energy conversion efficiency as high as 41 percent for an array of 6 cells or strings (GaP, AlGaAs, InGaP2, GaAs, and two different InGaAs cells or strings).

Mardesich, Nick↗

Helical tomotherapy quality assurance with ArcCHECK

To design a quality assurance (QA) procedure for helical tomotherapy that measures multiple beam parameters with 1 delivery and uses a rotating gantry to simulate treatment conditions. The customized QA procedure was preprogrammed on the tomotherapy operator station. The dosimetry measurements were performed using an ArcCHECK diode array and an A1SL ion chamber inserted in the central holder. The ArcCHECK was positioned 10 cm above the isocenter so that the 21-cm diameter detector array could measure the 40-cm wide tomotherapy beam. During the implementation of the new QA procedure, separate comparative measurements were made using ion chambers in both liquid and solid water, the tomotherapy onboard detector array, and a MapCHECK diode array for a period of 10 weeks. There was good agreement (within 1.3%) for the beam output and cone ratio obtained with the new procedure and the routine QA measurements. The measured beam energy was comparable (0.3%) to solid water measurement during the 10-week evaluation period, excluding 2 of the 10 measurements with unusually high background. The symmetry reading was similarly compromised for those 2 weeks, and on the other weeks, it deviated from the solid water reading by ∼2.5%. The ArcCHECK phantom presents a suitable alternative for performing helical tomotherapy QA, provided the background is collected properly. The proposed weekly procedure using ArcCHECK and water phantom makes the QA process more efficient.

61 RADIATION PROTECTION AND DOSIMETRY↗

Event-based Simulation Model for Quantum Optics Experiments

We present a corpuscular simulation model of optical phenomena that does not require the knowledge of the solution of a wave equation of the whole system and reproduces the results of Maxwell's theory by generating detection events one-by-one. The event-based corpuscular model gives a unified description of multiple-beam fringes of a plane parallel plate and single-photon Mach-Zehnder interferometer, Wheeler's delayed choice, photon tunneling, quantum eraser, two-beam interference, double-slit, Einstein-Podolsky-Rosen-Bohm and Hanbury Brown-Twiss experiments. We also discuss the possibility to refute our corpuscular model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A polar-drive-ignition design for the National Ignition Facility

Polar drive [Skupsky et al., Phys. Plasmas 11, 2763 (2004)] will enable direct-drive experiments to be conducted on the National Ignition Facility (NIF) [Miller et al., Opt. Eng. 43, 2841 (2004)], while the facility is configured for x-ray drive. A polar-drive ignition design for the NIF has been developed that achieves a gain of 32 in two-dimensional (2-D) simulations, which include single- and multiple-beam nonuniformities and ice and outer-surface roughness. This design requires both single-beam UV polarization smoothing and one-dimensional (1-D) multi-frequency modulator (MFM) single-beam smoothing to achieve the required laser uniformity. The multi-FM smoothing is employed only during the low-intensity portion of the laser pulse, allowing for the use of sufficient smoothing-by-spectral-dispersion bandwidth while maintaining safe laser operations during the high-intensity part of the pulse. This target is robust to all expected sources of perturbations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Highly accurate spectral retardance characterization of a liquid crystal retarder including Fabry-Perot interference effects

Multiple-beam Fabry-Perot (FP) interferences occur in liquid crystal retarders (LCR) devoid of an antireflective coating. In this work, a highly accurate method to obtain the spectral retardance of such devices is presented. On the basis of a simple model of the LCR that includes FP effects and by using a voltage transfer function, we show how the FP features in the transmission spectrum can be used to accurately retrieve the ordinary and extraordinary spectral phase delays, and the voltage dependence of the latter. As a consequence, the modulation characteristics of the device are fully determined with high accuracy by means of a few off-state physical parameters which are wavelength-dependent, and a single voltage transfer function that is valid within the spectral range of characterization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determination of the polarization state of x rays with the help of anomalous transmission

Besides intensity and direction, the polarization of an electromagnetic wave provides characteristic information on the crossed medium. Here, we present two methods for the determination of the polarization state of x rays by polarizers based on anomalous transmission (Borrmann effect). Using a polarizer-analyzer setup, we have measured a polarization purity of less than 1.5 × 10{sup −5}, three orders of magnitude better than obtained in earlier work. Using the analyzer crystal in multiple-beam case with slightly detuned azimuth, we show how the first three Stokes parameters can be determined with a single angular scan. Thus, polarization analyzers based on anomalous transmission make it possible to detect changes of the polarization in a range from degrees down to arcseconds.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Craniospinal irradiation techniques

In this paper we present one treatment plan for irradiation cases which involve a complex technique with multiple beams, using the 3D conformational technique. As the main purpose of radiotherapy is to administrate a precise dose into the tumor volume and protect as much as possible all the healthy tissues around it, for a case diagnosed with a primitive neuro ectoderm tumor, we have developed a new treatment plan, by controlling one of the two adjacent fields used at spinal field, in a way that avoids the fields superposition. Therefore, the risk of overdose is reduced by eliminating the field divergence.

60 APPLIED LIFE SCIENCES↗

Probing ultra-fast processes with high dynamic range at 4th-generation light sources: Arrival time and intensity binning at unprecedented repetition rates

Here, understanding dynamics on ultrafast timescales enables unique and new insights into important processes in the materials and life sciences. In this respect, the fundamental pump-probe approach based on ultra-short photon pulses aims at the creation of stroboscopic movies. Performing such experiments at one of the many recently established accelerator-based 4th-generation light sources such as free-electron lasers or superradiant THz sources allows an enormous widening of the accessible parameter space for the excitation and/or probing light pulses. Compared to table-top devices, critical issues of this type of experiment are fluctuations of the timing between the accelerator and external laser systems and intensity instabilities of the accelerator-based photon sources. Existing solutions have so far been only demonstrated at low repetition rates and/or achieved a limited dynamic range in comparison to table-top experiments, while the 4th generation of accelerator-based light sources is based on superconducting radio-frequency technology, which enables operation at MHz or even GHz repetition rates. In this article, we present the successful demonstration of ultra-fast accelerator-laser pump-probe experiments performed at an unprecedentedly high repetition rate in the few-hundred-kHz regime and with a currently achievable optimal time resolution of 13 fs (rms). Our scheme, based on the pulse-resolved detection of multiple beam parameters relevant for the experiment, allows us to achieve an excellent sensitivity in real-world ultra-fast experiments, as demonstrated for the example of THz-field-driven coherent spin precession.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simulations and measurements of hot-electron generation driven by the multibeam two-plasmon-decay instability

We report that multiple-beam experiments relevant to direct-drive inertial confinement fusion show the importance of nonlinear saturation mechanisms in the common-wave two-plasmon-decay (TPD) instability. Planar target experiments on the OMEGA laser used hard-x-ray measurements to study the influence of the linear common-wave growth rate on TPD driven hot-electron production in two drive beam configurations and over a range of overlapped laser intensities from 3.6 to 15.2 x 10 14 W/cm 2 . The beam configuration with the larger linear common-wave growth rate had a lower intensity threshold for the onset of hot-electron production, but the linear growth rate did not have a significant impact on hot-electron production at high intensities. The experiments were modeled in 3-D using a hybrid code (LPSE) that combines a wave solver with a particle tracker to self-consistently calculate the electron velocity distribution and evolve electron Landau damping. Finally, good quantitative agreement was obtained between the simulated and measured hotel-electron distributions using a novel technique to account for macroscopic spatial and temporal variations that are present in the experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Shock state distributions in porous tantalum and characterization with multipoint velocimetry

Heterogenous materials under shock compression can be expected to reach different shock states throughout the material according to local differences in microstructure and the history of wave propagation. Here, in this work, a compact, multiple-beam focusing optic assembly is used with high-speed velocimetry to interrogate the shock response of porous tantalum films prepared through thermal-spray deposition. The distribution of particle velocities across a shocked interface is compared to results obtained using a set of defocused interferometric beams that sampled the shock response over larger areas. The two methods produced velocity distributions along the shock plateau with the same mean, while a larger variance was measured with narrower beams. The finding was replicated using three-dimensional, mesoscopically resolved hydrodynamics simulations of solid tantalum with a pore structure mimicking statistical attributes of the material and accounting for radial divergence of the beams, with agreement across several impact velocities. Accounting for pore morphology in the simulations was found to be necessary for replicating the rise time of the shock plateau. The validated simulations were then used to show that while the average velocity along the shock plateau could be determined accurately with only a few interferometric beams, accurately determining the width of the velocity distribution, which here was approximately Gaussian, required a beam dimension much smaller than the spatial correlation lengthscale of the velocity field, here by a factor of ∼30×, with implications for the study of other porous materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A future of inertial confinement fusion without laser-plasma instabilities

From the beginning of inertial confinement fusion (ICF) research, laser-plasma instabilities excited by narrowband lasers have limited the hydrodynamic design space of all laser-based approaches to inertial fusion energy (IFE). With advances in broadband laser technologies, the next generation of ICF drivers will likely have large bandwidth that is engineered to mitigate laser-plasma instabilities, thereby expanding the hydrodynamic design space to include both robust high yields (>200−MJ) with large-energy laser systems (>4 MJ) and high gains (>10) with moderate-energy laser facilities (<2 MJ). State-of-the-art simulations indicate that laser bandwidths of a few percent are required to mitigate instabilities for IFE-relevant conditions. To test these models and demonstrate that high-bandwidth lasers mitigate laser-plasma instabilities, the Fourth-generation Laser for Ultrabroadband eXperiments will be used with the OMEGA Laser System. The goal is to provide the community with the confidence to invest in a multiple-beam high-bandwidth laser facility that will demonstrate the necessary ablation pressures for robust direct-drive ignition without detrimental levels of hot electrons that degrade the implosion performance. It is important to recognize that the highest performing ICF implosions will likely never be completely LPI free because of the significant advantages to maximizing the laser intensity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fractional laser microablation of skin: increasing the efficiency of transcutaneous delivery of particles

We study several regimes of fractional laser microablation using a pulsed Er : YAG laser for producing microchannels of different depth and incisions that allow transcutaneous delivery of particles of different size, namely, Al{sub 2}O{sub 3} (27 μm), ZrO{sub 2} (smaller than 5 μm) and TiO{sub 2} (smaller than 100 nm). The shock wave regime was used both for enhancing the penetration of particles into the ablation zones and as an independent method of particle delivery into the skin. Based on optical coherence tomography we assessed the coherent depth of particle detection in the skin in 2 hours, 3 days and 10 days after the administration. The maximal localisation depth (up to 450 μm) was obtained for TiO{sub 2} nanoparticles in the regime of incisions with enhancement of particle penetration by pulses of a multiple-beam hydrodynamic shock wave. The results of the study can be useful for developing new methods of transcutaneous delivery of micro- and nanocarriers of medicinal preparations. (laser biophotonics)

36 MATERIALS SCIENCE↗

COMPARISON OF RADIO-FREQUENCY INTERFERENCE MITIGATION STRATEGIES FOR DISPERSED PULSE DETECTION

Impulsive radio-frequency signals from astronomical sources are dispersed by the frequency-dependent index of refraction of the interstellar media and so appear as chirped signals when they reach Earth. Searches for dispersed impulses have been limited by false detections due to radio-frequency interference (RFI) and, in some cases, artifacts of the instrumentation. Many authors have discussed techniques to excise or mitigate RFI in searches for fast transients, but comparisons between different approaches are lacking. This work develops RFI mitigation techniques for use in searches for dispersed pulses, employing data recorded in a 'Fly's Eye' mode of the Allen Telescope Array as a test case. We gauge the performance of several RFI mitigation techniques by adding dispersed signals to data containing RFI and comparing false alarm rates at the observed signal-to-noise ratios of the added signals. We find that Huber filtering is most effective at removing broadband interferers, while frequency centering is most effective at removing narrow frequency interferers. Neither of these methods is effective over a broad range of interferers. A method that combines Huber filtering and adaptive interference cancelation provides the lowest number of false positives over the interferers considered here. The methods developed here have application to other searches for dispersed pulses in incoherent spectra, especially those involving multiple beam systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Measuring the redshift of reionization with a modest array of low-frequency dipoles

The designs of the first generation of cosmological 21-cm observatories are split between single dipole experiments which integrate over a large patch of sky in order to find the global (spectral) signature of reionization, and interferometers with arcminute-scale angular resolution whose goal is to measure the 3D power spectrum of ionized regions during reionization. We examine whether intermediate scale instruments with complete Fourier (uv) coverage are capable of placing new constraints on reionization. We find that even without using a full power spectrum analysis, the global redshift of reionization, z{sub reion}, can in principle be measured from the variance in the 21-cm signal among multiple beams as a function of frequency at a roughly 1 degree angular scale. At this scale, the beam-to-beam variance in the differential brightness temperature peaks when the average neutral fraction was ∼ 50%, providing a convenient flag of z{sub reion}. We choose a low angular resolution of order 1° to exploit the physical size of the ionized regions and maximize the signal-to-noise ratio. Thermal noise, foregrounds, and instrumental effects should also be manageable at this angular scale, as long as the uv coverage is complete within the compact core required for low-resolution imaging. For example, we find that z{sub reion} can potentially be detected to within a redshift uncertainty of Δz{sub reion}∼<1 in ∼>500 hours of integration on the existing MWA prototype (with only 32 × 16 dipoles), operating at an angular resolution of ∼ 1° and a spectral resolution of 2.4 MHz.

79 ASTRONOMY AND ASTROPHYSICS↗

Rotation of X-ray polarization in the glitches of a silicon crystal monochromator

EXAFS studies on dilute samples are usually carried out by collecting the fluorescence yield using a large-area multi-element detector. This method is susceptible to the `glitches' produced by all single-crystal monochromators. Glitches are sharp dips or spikes in the diffracted intensity at specific crystal orientations. If incorrectly compensated, they degrade the spectroscopic data. Normalization of the fluorescence signal by the incident flux alone is sometimes insufficient to compensate for the glitches. Measurements performed at the state-of-the-art wiggler beamline I20-scanning at Diamond Light Source have shown that the glitches alter the spatial distribution of the sample's quasi-elastic X-ray scattering. Because glitches result from additional Bragg reflections, multiple-beam dynamical diffraction theory is necessary to understand their effects. Here, the glitches of the Si(111) four-bounce monochromator of I20-scanning just above the Ni K edge are associated with their Bragg reflections. A fitting procedure that treats coherent and Compton scattering is developed and applied to a sample of an extremely dilute (100 micromolal) aqueous solution of Ni(NO 3 ) 2 . The depolarization of the wiggler X-ray beam out of the electron orbit is modeled. The fits achieve good agreement with the sample's quasi-elastic scattering with just a few parameters. The X-ray polarization is rotated up to ±4.3° within the glitches, as predicted by dynamical diffraction. These results will help users normalize EXAFS data at glitches.

Sutter, John P.↗