Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Frequency Distribution of Second Solid Cancer Locations in Relation to the Irradiated Volume Among 115 Patients Treated for Childhood Cancer

Purpose: To provide better estimates of the frequency distribution of second malignant neoplasm (SMN) sites in relation to previous irradiated volumes, and better estimates of the doses delivered to these sites during radiotherapy (RT) of the first malignant neoplasm (FMN). Methods and Materials: The study focused on 115 patients who developed a solid SMN among a cohort of 4581 individuals. The homemade software package Dos{sub E}G was used to estimate the radiation doses delivered to SMN sites during RT of the FMN. Three-dimensional geometry was used to evaluate the distances between the irradiated volume, for RT delivered to each FMN, and the site of the subsequent SMN. Results: The spatial distribution of SMN relative to the irradiated volumes in our cohort was as follows: 12% in the central area of the irradiated volume, which corresponds to the planning target volume (PTV), 66% in the beam-bordering region (i.e., the area surrounding the PTV), and 22% in regions located more than 5 cm from the irradiated volume. At the SMN site, all dose levels ranging from almost zero to >75 Gy were represented. A peak SMN frequency of approximately 31% was identified in volumes that received <2.5 Gy. Conclusion: A greater volume of tissues receives low or intermediate doses in regions bordering the irradiated volume with modern multiple-beam RT arrangements. These results should be considered for risk-benefit evaluations of RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

50 KW Multi-beam Klystron

Statement of problem or situation that is being addressed: microwave power sources (such as klystrons) offering an increased efficiency (80% or above) are needed for various applications. Of a particular interest is a source at 952.6 MHz delivering 50kW (continuous) CW for the RF systems for ion acceleration in the Energy Electron Ion Collider EIC being developed at Thomas Jefferson National Accelerator Facility. General statement of how this problem is being addressed: A novel tube (klystron) concept with efficiency in excess of 80%, delivering 50 kW CW at 952.6 MHz MHz is proposed. It is a combination of proven technologies put together: its uses multiple beams to have its perveance low to boost beam-power to RF efficiency. It uses a partially grounded depressed collector (as invented by Omega P R&D) with a carefully tailored beam distribution after the cavity chain to recover energy thereby increasing the overall efficiency even more. A low operating voltage makes the tube more user-friendly avoiding need for costly modulators and oil insulation. A sectioned solenoid is used to insure superb beam-matching to all components downstream of the electron gun, increasing the tube performances. What is to be done in Phase I: The overall goal of this project is to develop, design, engineer, manufacture and test a multi-beam klystron operating in CW regime, delivering 50kW CW of power at 952.6 MHz. The effort is to be coordinated with TJNAF to insure excellent compatibility with the facility. The device will have a high efficiency >80% (operating at 12kV). The main goals during Phase I are to numerically simulate and optimize the klystron main components, namely the gun, the RF cavity chain, the multi-channel-channel partially grounded depressed collector, and the magnetic system. Preliminary engineering issues will be coordinated by Omega-P R&D with its strategic alliance partner Calabazas Creek Research Inc., which expected to participate formally during Phase II in final design and fabrication. Commercial Applications and Other Benefits: The klystrons of this type can serve as the main RF-energy source of in RF-systems for accelerators which have found their applications both in science and industry, and is of high interest to Thomas Jefferson National Accelerator Facility.

RF power sources, klystron, high efficiency, CW, e↗

Phase II Final Report Computer Optimization of Electron Guns

This program implemented advanced computer optimization into an adaptive mesh, finite element, 3D, charged particle code. The routines can optimize electron gun performance to achieve a specified current, beam size, and perveance. It can also minimize beam ripple and electric field gradients. The magnetics optimization capability allows design of coil geometries and magnetic material configurations to achieve a specified axial magnetic field profile. The optimization control program, built into the charged particle code Beam Optics Analyzer (BOA) utilizes a 3D solid modeling package to modify geometry using design tables. Parameters within the graphical user interface (currents, voltages, etc.) can be directly modified within BOA. The program implemented advanced post processing capability for the optimization routines as well as the user. A Graphical User Interface allows the user to set up goal functions, select variables, establish ranges of variation, and define performance criteria. The optimization capability allowed development of a doubly convergent multiple beam gun that could not be designed using previous techniques.

43 PARTICLE ACCELERATORS↗

Untangling supernova-neutrino oscillations with {beta}-beam data

Recently, we suggested that low-energy {beta}-beam neutrinos can be very useful for the study of supernova-neutrino interactions. In this article, we examine the use of a such experiment for the analysis of a supernova-neutrino signal. Because supernova neutrinos are oscillating, it is very likely that the terrestrial spectrum of supernova neutrinos of a given flavor will not be the same as the energy distribution with which these neutrinos were first emitted. We demonstrate the efficacy of the proposed method for untangling multiple neutrino spectra. This is an essential feature of any model aiming at gaining information about the supernova mechanism, probing proto-neutron star physics, and understanding supernova nucleosynthesis, such as the neutrino process and the r-process. We also consider the efficacy of different experimental approaches including measurements at multiple beam energies and detector configurations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-Channel Correlator Array-Fed Microwave Radiometer

New antenna feed technology is needed for microwave radiometers as aperture sizes continue to increase. Capability for contiguous coverage and spatial Nyquist sampling can be achieved using a multi-beam array-fed reflector architecture adapted from radio astronomy. In this ACT (Advanced Component Technology), a wideband feed array for use in a multi-channel (X-W bands) scanning microwave radiometer is in development. The team, including array provider Nuvotronics Inc., is also developing a laboratory instrument to demonstrate the performance of the array-fed architecture at 36.5 gigahertz using an 80-centimeter projected aperture. The feed array is an 11-element line array based on a microfabricated 8-40 gigahertz feed. Multiple beams are generated by exciting overlapping groups of elements with each group shifted by one element spacing within the array. The modeled antenna patterns reveal six beams with 0.8-degree beamwidth and 0.3-degree spacing. This configuration is also a 1:26 electromagnetic scale model of a 1.41 gigahertz radiometer with a 21-meter aperture. The array-fed architecture for microwave radiometers has the potential to solve the developing need for high-spatial resolution, large aperture instruments. The objective relevancy scenario is a 6-meter aperture X-W band scanning radiometer purposed for high-resolution all-weather imaging of Earth's atmosphere and land, ice and ocean surfaces.

Microwave Radiometer↗

Fast ignition inertial fusion energy using laser-driven ion beams

Ion fast ignition (IFI), or fusion fast ignition initiated by a laser-driven ion beam, is a promising path to high-gain inertial fusion energy (IFE). In IFI, cold, dense deuterium-tritium (DT) fuel is first assembled using lasers or pulsed power drivers. Then, a high-power ion beam is focused onto a small volume within the fuel (the hot spot), heating the fuel rapidly to conditions where fusion ignition takes place. Fusion burn in this hot spot propagates to the fuel surrounding the hot spot, leading to burnup of a significant fraction of this fuel and the possibility of high gain (G~100), as needed for inertial fusion energy. IFI uses separate drivers for the two basic elements, fuel compression and ignition, allowing maximum control and optimization of each. On the other hand, conventional laser fusion uses multiple beams of the same driver to compress the fuel and shock-heat its very center to ignite a burn wave. Despite impressive progress in conventional laser fusion, the precise spatial symmetry, temporal pulse shaping and timing required for high gain and IFE remain a serious unmet challenge.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Developing a bright 17 keV x-ray source for probing high-energy-density states of matter at high spatial resolution

A set of experiments were performed on the National Ignition Facility (NIF) to develop and optimize a bright, 17 keV x-ray backlighter probe using laser-irradiated Nb foils. High-resolution one-dimensional imaging was achieved using a 15 μm wide slit in a Ta substrate to aperture the Nb He{sub α} x-rays onto an open-aperture, time integrated camera. To optimize the x-ray source for imaging applications, the effect of laser pulse shape and spatial profile on the target was investigated. Two laser pulse shapes were used—a “prepulse” shape that included a 3 ns, low-intensity laser foot preceding the high-energy 2 ns square main laser drive, and a pulse without the laser foot. The laser spatial profile was varied by the use of continuous phase plates (CPPs) on a pair of shots compared to beams at best focus, without CPPs. A comprehensive set of common diagnostics allowed for a direct comparison of imaging resolution, total x-ray conversion efficiency, and x-ray spectrum between shots. The use of CPPs was seen to reduce the high-energy tail of the x-ray spectrum, whereas the laser pulse shape had little effect on the high-energy tail. The measured imaging resolution was comparably high for all combinations of laser parameters, but a higher x-ray flux was achieved without phase plates. This increased flux was the result of smaller laser spot sizes, which allowed us to arrange the laser focal spots from multiple beams and produce an x-ray source which was more localized behind the slit aperture. Our experiments are a first demonstration of point-projection geometry imaging at NIF at the energies (>10 keV) necessary for imaging denser, higher-Z targets than have previously been investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The feasibility of electron beam slip stacking in EIC Rapid Cycling Synchrotron

Announced in 2020, the Electron Ion Collider will be constructed at Brookhaven National Lab (BNL) by modifying the existing Relativistic Heavy Ion Collider (RHIC) facility. Among the alterations include the installation of an electron storage ring (ESR) and a Rapid Cycling Synchrotron (RCS) in the existing RHIC tunnel. The RCS will accelerate polarized electrons from 400MeV to 5GeV,10GeV and 18 GeV and transfer it to the ESR. The LINAC source produces 7nC per shot meanwhile the RCS requires 28nC per bunch of charge. Currently, it is planned to inject 4 bunches into adjacent RF buckets and then merge them into a single RF bucket using fields from several RF cavities. However, this requires a kicker with an exceptionally fast rise and fall time to inject into adjacent RF bucket without disturbing the existing circulating bunch and this requires harmonic RF kickers. Our study focuses on determining the feasibility of an alternate particle injection method that will utilize slip stacking, a method that accommodates the circulation of multiple beams with different momentum in the same azimuthal space of the beampipe, thus permitting the accumulation of charge from several shots into a single RF bucket. We find the momentum aperture required for slip stacking using current RCS beam parameters exceeds the RCS’s momentum deviation limit,dp/p = 1.5%. We determine the appropriate dimensions the beam must have to enable slip stacking and conduct a literature review of slip stacking schemes in other facilities. The literature review tentatively indicates that slip stacking has not been attempted on electron beams at a major accelerator facility.. The slip stacking approach has the potential to save the cost of the harmonic RF kicker and bunch merging cavities.

43 PARTICLE ACCELERATORS↗

AN ARECIBO SEARCH FOR PULSARS AND TRANSIENT SOURCES IN M33

We report on a systematic and sensitive search for pulsars and transient sources in the nearby spiral galaxy M33, conducted at 1.4 GHz with the Arecibo telescope's seven-beam receiver system, ALFA. Data were searched for both periodic and aperiodic sources, up to 1000 pc cm{sup -3} in dispersion measure and on timescales from {approx}50 {mu}s to several seconds. The galaxy was sampled with 12 ALFA pointings, or 84 pixels in total, each of which was searched for 2-3 hr. We describe the observations, search methodologies, and analysis strategies applicable to multibeam systems, and comment on the data quality and statistics of spurious events that arise due to radio frequency interference. While these searches have not led to any conclusive signals of periodic or transient nature that originate in the galaxy, they illustrate some of the underlying challenges and difficulties in such searches and the efficacy of simultaneous multiple beams in the analysis of search output. The implied limits are {approx}<5 {mu}Jy Mpc{sup 2} in luminosity (at 1400 MHz) for periodic sources in M33 with duty cycles {approx}<5%. For short-duration transient signals (with pulse widths {approx}<100 {mu}s ), the limiting peak flux density is 100 mJy, which would correspond to a 5{sigma} detection of bright giant pulses ({approx}20 kJy) from Crab-like pulsars if located at the distance of M33. We discuss the implications of our null results for various source populations within the galaxy and comment on the future prospects to conduct even more sensitive searches with the upcoming next-generation instruments including the Square Kilometer Array and its pathfinders.

79 ASTRONOMY AND ASTROPHYSICS↗

Beamlet based direct aperture optimization for MERT using a photon MLC

Purpose: A beamlet based direct aperture optimization (DAO) for modulated electron radiotherapy (MERT) using photon multileaf collimator (pMLC) shaped electron fields is developed and investigated. Methods: The Swiss Monte Carlo Plan (SMCP) allows the calculation of dose distributions for pMLC shaped electron beams. SMCP is interfaced with the Eclipse TPS (Varian Medical Systems, Palo Alto, CA) which can thus be included into the inverse treatment planning process for MERT. This process starts with the import of a CT-scan into Eclipse, the contouring of the target and the organs at risk (OARs), and the choice of the initial electron beam directions. For each electron beam, the number of apertures, their energy, and initial shape are defined. Furthermore, the DAO requires dose–volume constraints for the structures contoured. In order to carry out the DAO efficiently, the initial electron beams are divided into a grid of beamlets. For each of those, the dose distribution is precalculated using a modified electron beam model, resulting in a dose list for each beamlet and energy. Then the DAO is carried out, leading to a set of optimal apertures and corresponding weights. These optimal apertures are now converted into pMLC shaped segments and the dose calculation for each segment is performed. For these dose distributions, a weight optimization process is launched in order to minimize the differences between the dose distribution using the optimal apertures and the pMLC segments. Finally, a deliverable dose distribution for the MERT plan is obtained and loaded back into Eclipse for evaluation. For an idealized water phantom geometry, a MERT treatment plan is created and compared to the plan obtained using a previously developed forward planning strategy. Further, MERT treatment plans for three clinical situations (breast, chest wall, and parotid metastasis of a squamous cell skin carcinoma) are created using the developed inverse planning strategy. The MERT plans are compared to clinical standard treatment plans using photon beams and the differences between the optimal and the deliverable dose distributions are determined. Results: For the idealized water phantom geometry, the inversely optimized MERT plan is able to obtain the same PTV coverage, but with an improved OAR sparing compared to the forwardly optimized plan. Regarding the right-sided breast case, the MERT plan is able to reduce the lung volume receiving more than 30% of the prescribed dose and the mean lung dose compared to the standard plan. However, the standard plan leads to a better homogeneity within the CTV. The results for the left-sided thorax wall are similar but also the dose to the heart is reduced comparing MERT to the standard treatment plan. For the parotid case, MERT leads to lower doses for almost all OARs but to a less homogeneous dose distribution for the PTV when compared to a standard plan. For all cases, the weight optimization successfully minimized the differences between the optimal and the deliverable dose distribution. Conclusions: A beamlet based DAO using multiple beam angles is implemented and successfully tested for an idealized water phantom geometry and clinical situations.

60 APPLIED LIFE SCIENCES↗

SU-E-J-203: Investigation of 1.5T Magnetic Field Dose Effects On Organs of Different Density

Purpose: For the combined 1.5T/6MV MRI-linac system, the perpendicular magnetic field to the radiation beam results in altered radiation dose distributions. This Monte Carlo study investigates the change in dose at interfaces for common organs neighboring soft tissue. Methods: MCNP6 was used to simulate the effects of a 1.5T magnetic field when irradiating tissues with a 6 MV beam. The geometries used in this study were not necessarily anatomically representative in size in order to directly compare quantitative dose effects for each tissue at the same depths. For this purpose, a 512 cm{sup 3} cubic material was positioned at the center of a 2744 cm{sup 3} cubic soft tissue material phantom. The following tissue materials and their densities were used in this study: lung (0.296 g/cm{sup 3}), fat (0.95), spinal cord (1.038), soft tissue (1.04), muscle (1.05), eye (1.076), trabecular bone (1.40), and cortical bone (1.85). Results: The addition of a 1.5T magnetic field caused dose changes of +46.5%, +2.4%, −0.9%, −0.8%, −1.5%, −6.5%, and −8.8% at the entrance interface between soft tissue and lung, fat, spinal cord, muscle, eye, trabecular bone, and cortical bone tissues respectively. Dose changes of −39.4%, −4.1%, −0.8%, −0.8%, +0.5%, +6.7%, and +10.9% were observed at the second interface between the same tissues respectively and soft tissue. On average, the build-up distance was reduced by 0.6 cm, and a dose increase of 62.7% was observed at the exit interface between soft tissue and air of the entire phantom. Conclusion: The greatest changes in dose were observed at interfaces containing lung and bone tissues. Due to the prevalence and proximity of bony anatomy to soft tissues throughout the human body, these results encourage further examination of these tissues with anatomically representative geometries using multiple beam configurations for safe treatment using the MRI-linac system.

60 APPLIED LIFE SCIENCES↗

Advanced Rainbow Solar Photovoltaic Arrays

Photovoltaic arrays of the rainbow type, equipped with light-concentrator and spectral-beam-splitter optics, have been investigated in a continuing effort to develop lightweight, high-efficiency solar electric power sources. This investigation has contributed to a revival of the concept of the rainbow photovoltaic array, which originated in the 1950s but proved unrealistic at that time because the selection of solar photovoltaic cells was too limited. Advances in the art of photovoltaic cells since that time have rendered the concept more realistic, thereby prompting the present development effort. A rainbow photovoltaic array comprises side-by-side strings of series-connected photovoltaic cells. The cells in each string have the same bandgap, which differs from the bandgaps of the other strings. Hence, each string operates most efficiently in a unique wavelength band determined by its bandgap. To obtain maximum energy-conversion efficiency and to minimize the size and weight of the array for a given sunlight input aperture, the sunlight incident on the aperture is concentrated, then spectrally dispersed onto the photovoltaic array plane, whereon each string of cells is positioned to intercept the light in its wavelength band of most efficient operation. The number of cells in each string is chosen so that the output potentials of all the strings are the same; this makes it possible to connect the strings together in parallel to maximize the output current of the array. According to the original rainbow photovoltaic concept, the concentrated sunlight was to be split into multiple beams by use of an array of dichroic filters designed so that each beam would contain light in one of the desired wavelength bands. The concept has since been modified to provide for dispersion of the spectrum by use of adjacent prisms. A proposal for an advanced version calls for a unitary concentrator/ spectral-beam-splitter optic in the form of a parabolic curved Fresnel-like prism array with panels of photovoltaic cells on two sides (see figure). The surface supporting the solar cells can be adjusted in length or angle to accommodate the incident spectral pattern. An unoptimized prototype assembly containing ten adjacent prisms and three photovoltaic cells with different bandgaps (InGaP2, GaAs, and InGaAs) was constructed to demonstrate feasibility. The actual array will consist of a lightweight thin-film silicon layer of prisms curved into a parabolic shape. In an initial test under illumination of 1 sun at zero airmass, the energy-conversion efficiency of the assembly was found to be 20 percent. Further analysis of the data from this test led to a projected energy conversion efficiency as high as 41 percent for an array of 6 cells or strings (GaP, AlGaAs, InGaP2, GaAs, and two different InGaAs cells or strings).

Mardesich, Nick↗

Helical tomotherapy quality assurance with ArcCHECK

To design a quality assurance (QA) procedure for helical tomotherapy that measures multiple beam parameters with 1 delivery and uses a rotating gantry to simulate treatment conditions. The customized QA procedure was preprogrammed on the tomotherapy operator station. The dosimetry measurements were performed using an ArcCHECK diode array and an A1SL ion chamber inserted in the central holder. The ArcCHECK was positioned 10 cm above the isocenter so that the 21-cm diameter detector array could measure the 40-cm wide tomotherapy beam. During the implementation of the new QA procedure, separate comparative measurements were made using ion chambers in both liquid and solid water, the tomotherapy onboard detector array, and a MapCHECK diode array for a period of 10 weeks. There was good agreement (within 1.3%) for the beam output and cone ratio obtained with the new procedure and the routine QA measurements. The measured beam energy was comparable (0.3%) to solid water measurement during the 10-week evaluation period, excluding 2 of the 10 measurements with unusually high background. The symmetry reading was similarly compromised for those 2 weeks, and on the other weeks, it deviated from the solid water reading by ∼2.5%. The ArcCHECK phantom presents a suitable alternative for performing helical tomotherapy QA, provided the background is collected properly. The proposed weekly procedure using ArcCHECK and water phantom makes the QA process more efficient.

61 RADIATION PROTECTION AND DOSIMETRY↗

Event-based Simulation Model for Quantum Optics Experiments

We present a corpuscular simulation model of optical phenomena that does not require the knowledge of the solution of a wave equation of the whole system and reproduces the results of Maxwell's theory by generating detection events one-by-one. The event-based corpuscular model gives a unified description of multiple-beam fringes of a plane parallel plate and single-photon Mach-Zehnder interferometer, Wheeler's delayed choice, photon tunneling, quantum eraser, two-beam interference, double-slit, Einstein-Podolsky-Rosen-Bohm and Hanbury Brown-Twiss experiments. We also discuss the possibility to refute our corpuscular model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A polar-drive-ignition design for the National Ignition Facility

Polar drive [Skupsky et al., Phys. Plasmas 11, 2763 (2004)] will enable direct-drive experiments to be conducted on the National Ignition Facility (NIF) [Miller et al., Opt. Eng. 43, 2841 (2004)], while the facility is configured for x-ray drive. A polar-drive ignition design for the NIF has been developed that achieves a gain of 32 in two-dimensional (2-D) simulations, which include single- and multiple-beam nonuniformities and ice and outer-surface roughness. This design requires both single-beam UV polarization smoothing and one-dimensional (1-D) multi-frequency modulator (MFM) single-beam smoothing to achieve the required laser uniformity. The multi-FM smoothing is employed only during the low-intensity portion of the laser pulse, allowing for the use of sufficient smoothing-by-spectral-dispersion bandwidth while maintaining safe laser operations during the high-intensity part of the pulse. This target is robust to all expected sources of perturbations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Highly accurate spectral retardance characterization of a liquid crystal retarder including Fabry-Perot interference effects

Multiple-beam Fabry-Perot (FP) interferences occur in liquid crystal retarders (LCR) devoid of an antireflective coating. In this work, a highly accurate method to obtain the spectral retardance of such devices is presented. On the basis of a simple model of the LCR that includes FP effects and by using a voltage transfer function, we show how the FP features in the transmission spectrum can be used to accurately retrieve the ordinary and extraordinary spectral phase delays, and the voltage dependence of the latter. As a consequence, the modulation characteristics of the device are fully determined with high accuracy by means of a few off-state physical parameters which are wavelength-dependent, and a single voltage transfer function that is valid within the spectral range of characterization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determination of the polarization state of x rays with the help of anomalous transmission

Besides intensity and direction, the polarization of an electromagnetic wave provides characteristic information on the crossed medium. Here, we present two methods for the determination of the polarization state of x rays by polarizers based on anomalous transmission (Borrmann effect). Using a polarizer-analyzer setup, we have measured a polarization purity of less than 1.5 × 10{sup −5}, three orders of magnitude better than obtained in earlier work. Using the analyzer crystal in multiple-beam case with slightly detuned azimuth, we show how the first three Stokes parameters can be determined with a single angular scan. Thus, polarization analyzers based on anomalous transmission make it possible to detect changes of the polarization in a range from degrees down to arcseconds.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Craniospinal irradiation techniques

In this paper we present one treatment plan for irradiation cases which involve a complex technique with multiple beams, using the 3D conformational technique. As the main purpose of radiotherapy is to administrate a precise dose into the tumor volume and protect as much as possible all the healthy tissues around it, for a case diagnosed with a primitive neuro ectoderm tumor, we have developed a new treatment plan, by controlling one of the two adjacent fields used at spinal field, in a way that avoids the fields superposition. Therefore, the risk of overdose is reduced by eliminating the field divergence.

60 APPLIED LIFE SCIENCES↗