Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiplicative correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Leveraging Quantum Sensors for Dark Matter Detection

Recent measurements have demonstrated that superconducting qubit decoherence is affected by radiation. As a result, many groups around the world are working to better understand the relationship between different types of radiation and qubit response. This crucial to quantum error correction because radiation can cause correlated loss of information across multiple qubits on a chip, defeating error correction algorithms. Additionally, the fundamental energy scale at which superconducting qubits operate may enable their development as meV-scale detectors for HEP applications, such as the direct detection of dark matter. At Fermilab, we have two world-class underground facilities which are already being used to study this problem: NEXUS and QUIET. I will present on results from operating superconducting qubits in each of these facilities, and the potential implications towards utilizing qubits as sensors for a novel dark matter detector.

Baxter, Daniel [Texas U., Arlington]↗

Leveraging Quantum Sensors for Dark Matter Detection

Recent measurements have demonstrated that superconducting qubit decoherence is affected by radiation. As a result, many groups around the world are working to better understand the relationship between different types of radiation and qubit response. This crucial to quantum error correction because radiation can cause correlated loss of information across multiple qubits on a chip, defeating error correction algorithms. Additionally, the fundamental energy scale at which superconducting qubits operate may enable their development as meV-scale detectors for HEP applications, such as the direct detection of dark matter. At Fermilab, we have two world-class underground facilities which are already being used to study this problem: NEXUS and QUIET. I will present on results from operating superconducting qubits in each of these facilities, and the potential implications towards utilizing qubits as sensors for a novel dark matter detector.

Baxter, Daniel [Texas U., Arlington]↗

Re-evaluation of neutron-{sup 4}He elastic scattering data near 20 MeV

Measured differential elastic-scattering cross sections of 17.72-, 20.97-, and 23.72-MeV neutrons from liquid helium-4 were re-evaluated and were corrected for sample-size and multiple-scattering effects by means of a Monte Carlo technique implemented in a more recent code (mcnpx). Results indicate that earlier corrections via the code maggie-2 overestimated the size of multiple-scattering effects by an order of magnitude. The corrected differential cross sections and Legendre coefficients obtained by least-squares fits are given.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A note on Hapke's bidirectional reflectance spectroscopy. Part 3: Correction for macroscopic roughness

The multiple-scattering theory of K. Lumme and E. Bowell (1981) was criticized by B. Hapke by stating, in particular, that energy is not conserved. It is shown that Hapke's treatment is, in this respect, inferior to that of Lumme and Bowell, and itself violates the principal concepts of radiative transfer theory. Hapke's additinal claim that, in Lumme and Bowell's work, the reflectance tends to zero at the limb is also refuted. Comment is made on the deduction of surface physical properties by modeling photometric observations.

Lumme, K.↗

Corrections to correlators in p{sub t} fluctuation measurements

Correction terms generated in the correlator analysis due to multiplicity-dependent observable mean are investigated. A procedure for the subtraction of correction terms from the correlators evaluated at fixed observed multiplicity is described. Benefits from the measurement of higher-order correlators are briefly discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Higher-order parabolic approximations for sound propagation in stratified moving media

Asymptotic solutions of order k-n are developed for the equations governing the propagation of sound through a stratified moving medium. Here k is a dimensionless wave number and n is the arbitrary order of the approximation. These approximations are an extension of geometric acoustics theory and provide corrections to that theory in the form of multiplicative functions which satisfy parabolic partial differential equations. These corrections account for the diffraction effects caused by variation of the field normal to the ray path and the interaction of these transverse variations with the variation of the field along the ray. The theory is illustrated by application to simple examples.

Mcaninch, G. L.↗

Higher order parabolic approximations of the reduced wave equation

Asymptotic solutions of order k to the nth are developed for the reduced wave equation. Here k is a dimensionless wave number and n is the arbitrary order of the approximation. These approximations are an extension of geometric acoustics theory, and provide corrections to that theory in the form of multiplicative functions which satisfy parabolic partial differential equations. These corrections account for the diffraction effects caused by variation of the field normal to the ray path and the interaction of these transverse variations with the variation of the field along the ray. The theory is applied to the example of radiation from a piston, and it is demonstrated that the higher order approximations are more accurate for decreasing values of k.

Mcaninch, G. L.↗

An approximation to multiple scattering in the earth's atmosphere Almucantar radiance formulation

An empirical expression is derived to account for the molecular multiple scattering contribution to the almucantar radiance field. Formulas for the correction factors which incorporate the effects of multiple scattering and nonzero ground albedo are also given. The use and accuracy of the multiple-scattering approximation in direct problems of radiative transfer associated with almucantar radiance are discussed and illustrated by examples. It is shown that in almost all instances, inclusion of the molecular multiple-scattering contribution reduces the errors obtained with the single-scattering approximation by a factor of at least 2.

Box, M. A.↗

Global Clear-Sky Surface Skin Temperature from Multiple Satellites Using a Single-Channel Algorithm with Angular Anisotropy Corrections

Surface skin temperature (T(sub s)) is an important parameter for characterizing the energy exchange at the ground/water-atmosphere interface. The Satellite ClOud and Radiation Property retrieval System (SatCORPS) employs a single-channel thermal-infrared (TIR) method to retrieve T(sub s) over clear-sky land and ocean surfaces from data taken by geostationary Earth orbit (GEO) and low Earth orbit (LEO) satellite imagers. GEO satellites can provide somewhat continuous estimates of T(sub s) over the diurnal cycle in non-polar regions, while polar T(sub s) retrievals from LEO imagers, such as the Advanced Very High Resolution Radiometer (AVHRR), can complement the GEO measurements. The combined global coverage of remotely sensed T(sub s), along with accompanying cloud and surface radiation parameters, produced in near-realtime and from historical satellite data, should be beneficial for both weather and climate applications. For example, near-realtime hourly T(sub s) observations can be assimilated in high-temporal-resolution numerical weather prediction models and historical observations can be used for validation or assimilation of climate models. Key drawbacks to the utility of TIR-derived T(sub s) data include the limitation to clear-sky conditions, the reliance on a particular set of analyses/reanalyses necessary for atmospheric corrections, and the dependence on viewing and illumination angles. Therefore, T(sub s) validation with established references is essential, as is proper evaluation of T(sub s) sensitivity to atmospheric correction source. This article presents improvements on the NASA Langley GEO satellite and AVHRR TIR-based T(sub s) product that is derived using a single-channel technique. The resulting clear-sky skin temperature values are validated with surface references and independent satellite products. Furthermore, an empirically adjusted theoretical model of satellite land surface temperature (LST) angular anisotropy is tested to improve satellite LST retrievals. Application of the anisotropic correction yields reduced mean bias and improved precision of GOES-13 LST relative to independent Moderate-resolution Imaging Spectroradiometer (MYD11_L2) LST and Atmospheric Radiation Measurement Program ground station measurements. It also significantly reduces inter-satellite differences between LSTs retrieved simultaneously from two different imagers. The implementation of these universal corrections into the SatCORPS product can yield significant improvement in near-global-scale, near-realtime, satellite-based LST measurements. The immediate availability and broad coverage of these skin temperature observations should prove valuable to modelers and climate researchers looking for improved forecasts and better understanding of the global climate model.

Scarino, Benjamin R.↗

Brief Guide on Outputting Custom Variables in SABLE

Although SABLE supports a wide variety of variable outputs as a default, the code currently does not readily support outputs of custom variables via the 'plot variables' feature in its input file. Workarounds to this issue exist (such as using `spy'), but the distinct convenience and advantage that the 'plot variables' feature provides, such as easy output of results in .exo file format, disappear. The user may explore the source code to correct this issue, but due to the ongoing nature of code building and complexity of the code spanning multiple languages and layers, exploration and correction of the code can be prohibitively difficult. In this memo, a short guide to modify the code to output desired custom variables via 'plot variables' is listed along with an example variable that evaluates the velocity profile before remapping (VELOCITY PREMAP).

97 MATHEMATICS AND COMPUTING↗

Documentation for the machine-readable version of the general catalogue of 33342 stars for the epoch 1950 (Boss 1937)

A revised and corrected version of the machine-readable catalog has been prepared. Cross identifications of the GC stars to the HD and DM catalogs have been replaced by data from the new SAO-HD-GC-DM Cross Index (Roman, Warren and Schofield 1983), including component identifications for multiple SAO entries having identical DM numbers in the SAO Catalog, supplemental Bonner Durchmusterung stars (lower case letter designations) and codes for multiple HD stars. Additional individual corrections have been incorporated based upon errors found during analyses of other catalogs.

Roman, N. G.↗

Jet energy measurement and its systematic uncertainty in proton–proton collisions at √s = 7 TeV with the ATLAS detector

The jet energy scale (JES) and its systematic uncertainty are determined for jets measured with the ATLAS detector using proton–proton collision data with a centre-of-mass energy of \(\sqrt{s}=7\) TeV corresponding to an integrated luminosity of \(4.7\) \(\,\,\text{ fb }^{-1}\). Jets are reconstructed from energy deposits forming topological clusters of calorimeter cells using the anti-\(k_{t}\) algorithm with distance parameters \(R=0.4\) or \(R=0.6\), and are calibrated using MC simulations. A residual JES correction is applied to account for differences between data and MC simulations. This correction and its systematic uncertainty are estimated using a combination of in situ techniques exploiting the transverse momentum balance between a jet and a reference object such as a photon or a \(Z\) boson, for \({20} \le p_{\mathrm {T}}^\mathrm {jet}<{1000}\, ~\mathrm{GeV }\) and pseudorapidities \(|\eta |<{4.5}\). The effect of multiple proton–proton interactions is corrected for, and an uncertainty is evaluated using in situ techniques. The smallest JES uncertainty of less than 1 % is found in the central calorimeter region (\(|\eta |<{1.2}\)) for jets with \({55} \le p_{\mathrm {T}}^\mathrm {jet}<{500}\, ~\mathrm{GeV }\). For central jets at lower \(p_{\mathrm {T}}\), the uncertainty is about 3 %. A consistent JES estimate is found using measurements of the calorimeter response of single hadrons in proton–proton collisions and test-beam data, which also provide the estimate for \(p_{\mathrm {T}}^\mathrm {jet}> 1\) TeV. The calibration of forward jets is derived from dijet \(p_{\mathrm {T}}\) balance measurements. The resulting uncertainty reaches its largest value of 6 % for low-\(p_{\mathrm {T}}\) jets at \(|\eta |=4.5\). In addition, JES uncertainties due to specific event topologies, such as close-by jets or selections of event samples with an enhanced content of jets originating from light quarks or gluons, are also discussed. The magnitude of these uncertainties depends on the event sample used in a given physics analysis, but typically amounts to 0.5–3 %.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Handbook of aircraft noise metrics

Information is presented on 22 noise metrics that are associated with the measurement and prediction of the effects of aircraft noise. Some of the instantaneous frequency weighted sound level measures, such as A-weighted sound level, are used to provide multiple assessment of the aircraft noise level. Other multiple event metrics, such as day-night average sound level, were designed to relate sound levels measured over a period of time to subjective responses in an effort to determine compatible land uses and aid in community planning. The various measures are divided into: (1) instantaneous sound level metrics; (2) duration corrected single event metrics; (3) multiple event metrics; and (4) speech communication metrics. The scope of each measure is examined in terms of its: definition, purpose, background, relationship to other measures, calculation method, example, equipment, references, and standards.

Bennett, R. L.↗

J/{psi} production and elliptic flow in relativistic heavy-ion collisions

Using the two-component model for charmonium production, which includes contributions from both initial hard nucleon-nucleon scattering and from regeneration in the quark-gluon plasma, we study the nuclear modification factor R{sub AA} and elliptic flow v{sub 2} of J/{psi} in relativistic heavy-ion collisions. For the expansion dynamics of produced hot, dense matter, we introduce a schematic fireball model with its transverse acceleration determined from the pressure gradient inside the fireball and azimuthally anisotropic expansion parametrized to reproduce measured v{sub 2} of light hadrons. We assume that light hadrons freeze out at the temperature of 120 MeV while charmonia freeze out at 160 MeV, similar to the kinetic and chemical freeze-out temperatures in the statistical model, respectively. For the properties of charmonia in the quark-gluon plasma, we use the screening mass between their charm and anticharm quarks and their dissociation cross sections given by the perturbative quantum chromodynamical (pQCD) calculations in the leading order and up to the next-to-leading order, respectively. For the relaxation time of charm and anticharm quarks in the quark-gluon plasma, we also use the one calculated in the leading-order pQCD. Modeling the effect of higher-order corrections in pQCD by introducing multiplicative factors to the dissociation cross sections of charmonia and the elastic scattering cross sections of charm and anticharm quarks, we find that this effect is small for the R{sub AA} of J/{psi} as they suppress the number of initially produced J/{psi} but enhance the number of regenerated ones. The higher-order corrections increase, however, the v{sub 2} of J/{psi}. Our results suggest that the v{sub 2} of J/{psi} can play an important role in discriminating between J/{psi} production from initial hard collisions and from regeneration in the quark-gluon plasma.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sensor calibration for multiple direction reflectance observations

Spectral and radiometric calibrations of a pointable airborne spectroradiometer called ASAS are discussed. A laboratory integrating hemisphere is used to characterize the radiometric respones of ASAS detectors. Radiometric responses are linear except for an initial build-up lag in response to low levels of radiance. Assuming radiometric stability in flight, raw ASAS digital counts can be transformed to absolute spectral radiance values with an uncertainty of 5.5 percent attributable to the laboratory calibration. The calibrations are being applied to radiometrically correct ASAS data acquired from multiple view directions over a tall grass prairie during the 1987 growing season.

Irons, James R.↗

Use of radar in urban studies

The use of side-looking airborne radar for urban studies is reviewed with attention given to the work of Moore (1969) and Lewis (1968) which may be summarized as follows: (1) linear elements of the transportation net were easily defined, (2) gross patterns of industry, residential and open space land were identified, but it was not possible to map the land use boundaries in great detail, (3) commercial land areas were often difficult to identify, and (4) multiple polarized imagery was helpful in correctly interpreting the total scene. It is found that the sensitivity of radar to surface roughness and the availability of multiple wavelength data allow the discrimination of variations in the surface roughness of intra-urban areas. An L-band imaging radar (25 cm; 1215-1225 GHz) of 25 m resolution will be operating from satellite altitudes in 1978 and will increase the availability of radar data.

Bryan, M. L.↗

Terrain effects on backscattering coefficients derived from multifrequency, polarimetric SAR data

A set of multidate, multilook angle polarimetric SAR data, acquired in Pennsylvania during July 1990 was recorded to determine the effect of local incidence angle. Cosine-based and polynomial models are found to be equally good for correcting SAR data for local incidence angle effects. A modified approach, considering the correction factor as additive rather than multiplicative, gave better results. The standard error in the estimation of soil moisture improves from 8.1 to 5.8 after applying corrections to incidence angle effects.

Rao, K. S.↗

Towards Energy Scale Calibration and Drift Correction of TES Detectors for Athena X-IFU

The Athena X-Ray Integral Field Unit (X-IFU) comprises a 2376-pixel array of transition edge sensors (TES) read out with time-division multiplexing (TDM). X-IFU will provide spatially resolved, high-resolution spectroscopy (2.5 eV full-width-half-maximum up to 7 keV) over the energy range 0.2 to 12 keV, with an absolute energy scale accuracy of 0.4 eV. The energy scale function maps the optimally filtered pulse height, in arbitrary engineering units, to real calibrated energy. Uncertainties in the calibration can result from imperfect fitting of the energy scale between the known calibration points. Furthermore, temporal changes in the TES operating environment, such as heat-sink temperature, magnetic field and bias voltage, can cause significant variations in the detector gain function over time. If not properly corrected, this can result in degradation of the energy resolution, and systematic errors in the absolute energy scale. The non-linear nature of TES detectors, coupled with the possibility of multiple simultaneously occurring sources of drift, can make effective corrections over the full bandpass of the instrument extremely challenging. Athena X-IFU will employ an on-board calibration source that provides known reference x-ray lines. This provides real-time monitoring of the gain stability of the detector system and information that can be used to correct for gain drifts. For X-IFU the baseline approach is to measure a series of calibration curves under different environmental conditions, which bound the expected drifts the instrument is predicted to see over the course of the mission. Using the information from the in-flight calibration source, these energy scale functions can be interpolated to generate a new corrected energy scale as a function of time. In this paper we discuss progress towards demonstrating that the X-IFU energy scale requirements can be met. We present measurements on ~ 200 pixels in a prototype X-IFU array read out with 8-column x 32-row TDM. We use a rotating target source containing 12 fluorescent targets to generate x-ray lines covering the energy range 4 keV (Sc-Kα) to 12 keV (Br-Kα). We present measurements of the non-linear energy scale function and show how variations in heat-sink temperature, TES bias voltage and magnetic field affect the shape of TES energy scale differently and introduce different residual gain errors over the bandpass. We explore different drift correction algorithms that use either a single or multiple referential lines to track and correct the gain from these various sources of drift. In addition to the pulse-height, the DC ‘baseline’ level of the TES can contain information about its bias conditions. Thus, we test a multi-parameter gain correction algorithm that attempts to incorporate both the pulse height and the additional baseline information into the algorithm.

Stephen J Smith↗