Search NASA⌕ Search

SEARCH · Search NASA

Results for “noise reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

High-sensitivity telecommunication-compatible photoconductive terahertz detection through carrier transit time reduction

We present a telecommunication-compatible photoconductive terahertz detector realized without using any short-carrier-lifetime photoconductor. By utilizing plasmonic contact electrodes on a thin layer of high-mobility photoconductor, the presented detector offers a short transit time for the majority of the photocarriers in the absence of a short-carrier-lifetime photoconductor. Consequently, high-sensitivity terahertz detection is achieved with a record-high signal-to-noise ratio of 122 dB over a 3.6 THz bandwidth under an optical probe power of 10 mW. To achieve such a high sensitivity, the device geometry is chosen to maintain a high resistance and low Johnson Nyquist noise. This design approach can be widely applied for terahertz detection using various semiconductors and optical wavelengths, without being limited by the availability of short-carrier-lifetime photoconductors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new route to obtain fluorescence X-ray absorption spectra of compounds and to remove the self-absorption induced nonlinearity in the spectra

A new route to obtain fluorescence X-ray absorption spectra of compounds and to remove the self-absorption induced nonlinearity in the spectra is described. The fluorescent intensity If is linearly proportional to the absorption coefficient μ. For studies of surface structures around an element (κ) the fluorescence detection is often the mode of choice. However, the measurement may suffer from a self-absorption (SA) effect which nonlinearly distorts the spectra. The effect is severe when κ is concentrated or the measurements are carried out in certain geometries. Here, the correlations among emission events in compounds are examined following resonance X-ray core-electron excitation within κ. Under conditions leading to SA, If emitted from κ apparently has a conjugated relationship with the fluorescent intensities simultaneously emitted from other elements (ξ). Normalizing the former (κ) by the latter (ξ) will largely remove SA effects and reduce this nonlinear problem to a tractable linear problem. This does result in a moderate reduction of the spectral amplitude due to the so-called secondary emission from ξ excited by the emission from κ. Nonetheless, the resulting spectra will allow one to accurately determine bond distances and disorder and, in some respects, can be superior to spectra obtained via the absorption channel. For μξ < μκ and grazing incidence geometry, the amplitude reduction can be small and simple normalization is sufficient to restore the spectral integrity with remarkable accuracy. This has been instrumental in unravelling the surface and subsurface structures around cations in amorphous Ga–In–O and Zn–Sn–O films which are otherwise inaccessible due to severe SA effects. This method has also been applied to several samples with μξ ≃ μκ to examine its applicability. For these samples, the amplitude reduction is 12 ± 4% versus their standards for the data measured with the classical 45°/45° geometry. This experimental method is easy to implement. Since If from κ and ξ are measured by the same detector system, it is also superior to other methods in removing systematic errors such as detector system nonlinearity, electronic noise, and some beam instabilities, and in removing spectral imperfections due to, for example, SA effects, diffraction effects and sample inhomogeneity. The distortions resulting from the latter can be severe in the spectra measured in transmission mode.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Overview of CMOS Sensors for Future Tracking Detectors

Depleted Complementary Metal-Oxide-Semiconductor (CMOS) sensors are emerging as one of the main candidate technologies for future tracking detectors in high luminosity colliders. Their capability of integrating the sensing diode into the CMOS wafer hosting the front-end electronics allows for reduced noise and higher signal sensitivity, due to the direct collection of the sensor signal by the readout electronics. They are suitable for high radiation environments due to the possibility of applying high depletion voltage and the availability of relatively high resistivity substrates. The use of a CMOS commercial fabrication process leads to their cost reduction and allows faster construction of large area detectors. In this contribution, a general perspective of the state of the art of CMOS detectors for High Energy Physics experiments is given. The main developments carried out with regard to these devices in the framework of the CERN RD50 collaboration are summarized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced detection of paramagnetic fluorine-19 magnetic resonance imaging agents using zero echo time sequence and compressed sensing

Fluorine-19 ( 19 F) magnetic resonance imaging (MRI) is an emerging technique offering specific detection of labeled cells in vivo. Lengthy acquisition times and modest signal-to-noise ratio (SNR) makes three-dimensional spin-density–weighted 19 F imaging challenging. Recent advances in tracer paramagnetic metallo-perfluorocarbon (MPFC) nanoemulsion probes have shown multifold SNR improvements due to an accelerated 19 F T 1 relaxation rate and a commensurate gain in imaging speed and averages. However, 19 F T 2 -reduction and increased linewidth limit the amount of metal additive in MPFC probes, thus constraining the ultimate SNR. To overcome these barriers, we describe a compressed sampling (CS) scheme, implemented using a “zero” echo time (ZTE) sequence, with data reconstructed via a sparsity-promoting algorithm. Our CS-ZTE scheme acquires k-space data using an undersampled spherical radial pattern and signal averaging. Image reconstruction employs off-the-shelf sparse solvers to solve a joint total variation and -norm regularized least square problem. To evaluate CS-ZTE, we performed simulations and acquired 19 F MRI data at 11.7 T in phantoms and mice receiving MPFC-labeled dendritic cells. For MPFC-labeled cells in vivo, we show SNR gains of ~6.3 × with 8-fold undersampling. We show that this enhancement is due to three mechanisms including undersampling and commensurate increase in signal averaging in a fixed scan time, denoising attributes from the CS algorithm, and paramagnetic reduction of T 1 . Importantly, 19 F image intensity analyses yield accurate estimates of absolute quantification of 19 F spins. Overall, the CS-ZTE method using MPFC probes achieves ultrafast imaging, a substantial boost in detection sensitivity, accurate 19 F spin quantification, and minimal image artifacts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarized target nuclear magnetic resonance measurements with deep neural networks

Continuous-wave Nuclear Magnetic Resonance (CW-NMR) operated in constant-current mode has served as a foundational technique for polarization measurement in solid-state dynamically polarized targets within nuclear and high-energy physics experiments for several decades, and it remains an essential tool. Conventional Q-meter-based phase-sensitive detection is critical for precise real-time determination of target polarization during scattering runs. However, the accuracy and reliability of these measurements are frequently compromised by elevated noise levels, baseline drift, and systematic uncertainties arising from signal isolation and fitting, ultimately degrading the overall experimental figure of merit. In this work, we report the first successful application of neural network architectures to continuous-wave NMR polarization metrology. By leveraging advanced machine learning techniques for signal extraction and denoising, we achieve a substantial reduction of fitting uncertainties under a variety of realistic simulated and experimental conditions. These improvements translate directly into more robust real-time (online) polarization monitoring and higher precision in subsequent offline analysis. By reducing analysis-induced uncertainty, the resulting methodology can improve the effective figure of merit for scattering experiments employing dynamically polarized targets and provides a new toolset for NMR-based polarimetry in high-energy and nuclear physics.

Metrology↗

Variance Reduction within Implicit Monte Carlo Thermal Radiation Transport using the Local Importance Function Transform [Slides]

System of equations derived by Fleck and Cummings to model time-dependent thermal radiative transfer (TRT) problems: Solution of radiation specific intensity (I), non-linearly coupled to material internal energy (U); Absorption and re-emission approximated by effective scattering events. Useful for high-energy density physics simulations: i.e., astrophysics, inertial confinement fusion (ICF). Whereas deterministic methods are fully discretized and free of statistical noise, Monte Carlo methods allow for dynamic sampling of the phase space at the price of statistical noise; Monte Carlo methods are also characterized by a slow $\frac{1}{√Ν}$ convergence rate.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DP-TwoLevel: two-stage gradient subspace learning for differentially private federated learning

Federated learning (FL) enables collaborative model training across distributed data sources without sharing raw data, but faces fundamental challenges in communication efficiency and privacy. Differentially private (DP) training mitigates information leakage but introduces noise that degrades model performance, especially in high-dimensional settings. We propose DP-TwoLevel, a hierarchical gradient projection method that improves utility under fixed DP constraints by exploiting low-dimensional structure in model updates. Our approach learns a two-level PCA-based representation of gradients and applies DP noise in a reduced-dimensional subspace, thereby lowering the effective noise magnitude while preserving dominant signal components. We evaluate the method across three datasets (MNIST, Fashion-MNIST, CIFAR-10) and three privacy regimes (ϵ∈0.5, 1.0, 2.0). Across nine experimental settings, DP-TwoLevel consistently outperforms DP-FedAvg, achieving an average accuracy improvement of 9.44%, with larger gains observed in lower ϵ(higher-noise) regimes (up to +22.31%). We further analyze scalability across models ranging from 100K to 1.49M parameters and identify a variance-based success criterion: performance remains strong when the projection preserves more than 75% of gradient variance, degrades in a marginal regime (65–75%), and fails below this threshold. Our results demonstrate that structure-aware dimensionality reduction can significantly improve the privacy–utility tradeoff in FL without modifying formal privacy guarantees. We also provide empirical evidence of scaling limitations for global projections and motivate per-layer extensions for larger models.

Kotevska, Olivera [ORNL] (ORCID:0000000316772243)↗

Laser-Induced Spectrochemical Assay for Uranium Enrichment (LISA-UE)

Uranium hexafluoride (UF6) is the uranium compound typically involved in uranium enrichment process. As the first line of defense against nuclear proliferation, accurate determinations of the uranium enrichment ratio in UF6 are critical for materials verification, accounting and safeguards. Shipping gaseous UF6 samples off-site for analysis with mass spectrometry is cumbersome and costly, and results are not available for some time (months). In-field UF6 enrichment assay has the potential to substantially reduce the time, logistics and expense of sample handling. At present, COMPUCEA is the only accepted method for UF6 enrichment assay in the field. Laser-Induced Spectrochemical Assay for Uranium Enrichment (LISA-UE) is an all-optical (based on laser induced plasma emission) analytical technique intended for fieldable, accurate, precise and rapid UF6 enrichment assay. In its operation, laser induced plasma is created directly in the gaseous UF6 sample. Because different U isotopes emit at slightly different wavelengths, the isotopic information of the UF6 sample is inherently encoded in the atomic emission from the plasma. Isotopic emissions from 235U and 238U are measured simultaneously, which eliminate correlated noise from the laser induced plasma. Isotopic information of the UF6 sample can be extracted from the acquired spectrum with theoretical multi-variable non-linear spectral fitting. To date, advances made by the LISA-UE research team include optimization of the spectral window for direct gaseous UF6 enrichment assay with laser induced plasma, development of data reduction algorithms, and demonstrations of the LISA-UE technique with gaseous UF6 samples. In this presentation, the technical aspect of LISA-UE will be overviewed, the data reduction algorithm will be described, and performance of the technique will be discussed.

Chan, George↗

GTC Follow-up Observations of Very Metal-poor Star Candidates from DESI

Abstract The observations from the Dark Energy Spectroscopic Instrument (DESI) will significantly increase the numbers of known extremely metal-poor stars by a factor of ∼10, improving the sample statistics to study the early chemical evolution of the Milky Way and the nature of the first stars. In this paper we report follow-up observations with high signal-to-noise ratio of nine metal-poor stars identified during the DESI commissioning with the Optical System for Imaging and Low-Resolution Integrated Spectroscopy (OSIRIS) instrument on the 10.4 m Gran Telescopio Canarias. The analysis of the data using a well-vetted methodology confirms the quality of the DESI spectra and the performance of the pipelines developed for the data reduction and analysis of DESI data.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhancement of radiation detection performance with reduction of EH 6/7 deep levels in n-type 4H–SiC through thermal oxidation

We report the effect of EH 6/7 electron trap centers alone on the performance of high-resolution radiation detectors fabricated on n-type 4H–SiC epitaxial layers. A Schottky barrier detector (SBD) and a metal-oxide-semiconductor (MOS) capacitor detector fabricated using two sister samples derived from the same 50 μm 4H–SiC parent wafer exhibited widely different energy resolutions of 0.4% and 0.9% for 5486 keV alpha particles. An equivalent noise charge model analysis ruled out the effect of the detector capacitance and the leakage current on the resolution of the detectors. Deep level transient spectroscopic studies revealed the presence of two trapping centers in each detector within the temperature scan range 240–800 K. The Z 1/2 center, a potential electron trap, was detected in both the detectors in equal concentration, which suggested that the observed difference in the energy resolution is due to the presence of the other defect, the EH 6/7 center, in the SBD. The capture cross section of the EH 6/7 center was calculated to be three orders of magnitude higher than the second defect [a carbon antisite vacancy (CAV) center] observed in the MOS detector with an activation energy of 1.10 eV, which accounted for the enhanced electronic trapping in the SBD leading to its poor energy resolution. It has been proposed that the EH 6/7 centers in the SBD have likely been reconfigured to CAV pairs during the thermal growth of the silicon dioxide layer in the MOS detector. The proposed formation mechanism of CAV, a stable qubit state for quantum information processing, addresses the outstanding questions related to the role of defect dynamics in their formation.

61 RADIATION PROTECTION AND DOSIMETRY↗

A deterministic verification strategy for electrostatic particle-in-cell algorithms in arbitrary spatial dimensions using the method of manufactured solutions

As simulations of kinetic plasmas continue to increase in scope and complexity, a rigorous and straightforward method for verifying particle-in-cell (PIC) implementations is necessary to ensure their correctness. Here, in this paper, we present a deterministic method for the rigorous verification of multidimensional, multispecies, electrostatic particle-in-cell codes based on the method of manufactured solutions. Specifically, we prove that rigorous verification is possible through the exclusive examination of errors of grid quantities (i.e., moments and/or fields), allowing for a very light-weight and non-intrusive implementation in existing PIC codes. This is a marked improvement over earlier PIC verification approaches (only demonstrated with one species in 1D-1V), which rely on the comparison of cumulative distribution functions, and are invasive on the code base, introduce additional stochastic noise, are significantly more computationally expensive, and lack rigorous convergence properties. Interestingly, we show that different grid quantities feature different rates of convergence with the number of particles and mesh size, impacting the verification process. These theoretical results are confirmed numerically with a multi-species 2D-2V particle-in-cell code, including the ability of the method to detect order reduction due to an incorrect implementation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development and Demonstration of Medium-Heavy Duty PHEV Work Trucks

The heavy-duty vehicle market (Class 6-8) has been a difficult segment for the introduction of plug-in vehicles due to the large energy storage requirement (with corresponding cost), challenging duty cycles, and the diversity of vehicle configurations. The Work Truck market represents a significant opportunity for Heavy-Duty PHEV adoption. (1) The usage cycle includes driving and stationary/worksite power requirements, ensuring full daily usage of the grid-charged battery (battery size: 15-30kWhr). Though daily driving can often be short (an average of 26 miles per day), worksite power includes substantial demand (hydraulics, exportable 110/220V power, 12V support, HVAC). (2) Worksite power demands for conventional vehicles require continuous loaded engine operation, resulting in significant emissions, fuel consumption and noise impacts. (3) These trucks serve an industry that is highly diverse in final vehicle duty cycle, configuration, and jobsite power demands resulting in the need for a modular, configurable hybrid solution. Through this program, Odyne has developed and demonstrated a medium/heavy duty plug-in hybrid solution capable of meeting the needs of the work truck market while delivering fuel and emissions reductions of 50% or greater when evaluated against the full-day work truck duty cycle. The Odyne system developed in this project was released for commercial sale as the G2V7 Odyne Plug-in Hybrid and ePTO systems. The testing and field demonstration proved that the Odyne hybrid system is capable of reducing work truck fuel use and emissions by over 50% while subsequent commercial sales demonstrate the flexibility of the modular design and the capability to support electric systems of 12 – 30 kW and hydraulic based systems of 60 kW (80 HP) or greater. Odyne is continuing to work with suppliers on reducing component costs and working with supporting agencies to initiate projects to increase the driving and full day fuel and emissions savings in order to continue to improve the customer value and return on investment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Localization and reduction of superconducting quantum coherent circuit losses

Quantum sensing and computation can be realized with superconducting microwave circuits. Qubits are engineered quantum systems of capacitors and inductors with non-linear Josephson junctions. They operate in the single-excitation quantum regime, photons of $27 \mu$eV at 6.5 GHz. Quantum coherence is fundamentally limited by materials defects, in particular atomic-scale parasitic two-level systems (TLS) in amorphous dielectrics at circuit interfaces.[1] The electric fields driving oscillating charges in quantum circuits resonantly couple to TLS, producing phase noise and dissipation. We use coplanar niobium-on-silicon superconducting resonators to probe decoherence in quantum circuits. By selectively modifying interface dielectrics, we show that most TLS losses come from the silicon surface oxide, and most non-TLS losses are distributed throughout the niobium surface oxide. Through post-fabrication interface modification we reduced TLS losses by 85% and non-TLS losses by 72%, obtaining record single-photon resonator quality factors above 5 million and approaching a regime where non-TLS losses are dominant. [1]M\"uller, C., Cole, J. H. & Lisenfeld, J. Towards understanding two-level-systems in amorphous solids: insights from quantum circuits. Rep. Prog. Phys. 82, 124501 (2019)

Altoé, M Virginia P↗

Aerial Crosspolarized NQR-NMR: Buried Explosive Detection From a Safe Distance

Nuclear quadrupole resonance is a non-destructive detection and inspection technique with potential as a non-destructive test (NDT) tool. Establishment of the capability opens the door to its use in furthering the mission of the labs. There are many possible uses of the capability: explosive detection and stress/strain detection in epoxies are two of the more obvious and are the main results of this work. Enhancement of the signal-to-noise ratio (SNR) and improvements in the acquisition time of the experiment were key focuses of this work. These were achieved by combing special spin-lock pulse sequences with cross-polarization (CP) schemes to improve the signals with shorter acquisition times. A novel rotating magnetic field device was created to facilitate CP in the field. Implementation of these schemes provided a significant reduction in SNR/time.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Constraints on Λ CDM extensions from the SPT-3G 2018 $EE$ and $TE$ power spectra

Here, we present constraints on extensions to the Λ CDM cosmological model from measurements of the E-mode polarization autopower spectrum and the temperature-E-mode cross-power spectrum of the cosmic microwave background (CMB) made using 2018 SPT-3G data. The extensions considered vary the primordial helium abundance, the effective number of relativistic degrees of freedom, the sum of neutrino masses, the relativistic energy density and mass of a sterile neutrino, and the mean spatial curvature. We do not find clear evidence for any of these extensions, from either the SPT-3G 2018 dataset alone or in combination with baryon acoustic oscillation and Planck data. None of these model extensions significantly relax the tension between Hubble-constant, H 0 , constraints from the CMB and from distance-ladder measurements using Cepheids and supernovae. The addition of the SPT-3G 2018 data to Planck reduces the square-root of the determinants of the parameter covariance matrices by factors of 1.3–2.0 across these models, signaling a substantial reduction in the allowed parameter volume. We also explore CMB-based constraints on H 0 from combined SPT, Planck, and ACT DR4 datasets. While individual experiments see some indications of different H 0 values between the TT, TE, and EE spectra, the combined H 0 constraints are consistent between the three spectra. For the full combined datasets, we report H 0 = 67.49 ± 0.53 km s -1 Mpc -1 , which is the tightest constraint on H0 from CMB power spectra to date and in 4.1σ tension with the most precise distance-ladder-based measurement of H 0 . The SPT-3G survey is planned to continue through at least 2023, with existing maps of combined 2019 and 2020 data already having ~ 3.5 x lower noise than the maps used in this analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraining cosmological parameters using the pairwise kinematic Sunyaev-Zel’dovich effect with CMB-S4 and future galaxy cluster surveys

We present a forecast of the pairwise kinematic Sunyaev-Zel’dovich (kSZ) measurement that will be achievable with the future CMB-S4 experiment. CMB-S4 is the next stage for ground-based cosmic microwave background experiments, with a planned wide-area survey that will observe approximately 50% of the sky. We construct a simulated sample of galaxy clusters that have been optically selected in a Legacy Survey of Space and Time–like survey and have spectroscopic redshifts. For this cluster sample, assuming the likelihood is Gaussian, we predict that CMB-S4 will reject the null hypothesis of zero pairwise kSZ signal at 36⁢𝜎. We estimate the effects of systematic uncertainties such as scatter in the mass-richness scaling relation and cluster miscentering. We find that these effects can reduce the signal-to-noise ratio of the CMB-S4 pairwise kSZ measurement by 20%. We explore the constraining power of the measured kSZ signal in combination with measurements of the galaxy clusters’ thermal SZ emission on two extensions to the standard cosmological model. The first extension allows the dark energy equation of state 𝑤 to vary. We find the CMB-S4 pairwise kSZ measurement yields a modest reduction in the uncertainty on 𝑤 by a factor of 1.36 over the Planck’s 2018 uncertainty. The second extension tests general relativity by varying the growth index 𝛾. In conclusion, we find that CMB-S4’s pairwise kSZ measurement will yield a 28⁢𝜎 constraint on 𝛾 and strongly constrain alternative theories of gravity.

79 ASTRONOMY AND ASTROPHYSICS↗

Waveform processing using neural network algorithms on the front-end electronics

In a multi-channel radiation detector readout system, waveform sampling, digitization, and raw data transmission to the data acquisition system constitute a conventional processing chain. The deposited energy on the sensor is estimated by extracting peak amplitudes, area under pulse envelopes from the raw data, and starting times of signals or time of arrivals. However, such quantities can be estimated using machine learning algorithms on the front-end Application-Specific Integrated Circuits (ASICs), often termed as “edge computing”. Edge computation offers enormous benefits, especially when the analytical forms are not fully known or the registered waveform suffers from noise and imperfections of practical implementations. In this work, we aim to predict peak amplitude from a single waveform snippet whose rising and falling edges containing only 3 to 4 samples. We thoroughly studied two well-accepted neural network algorithms, Multi-Layer Perceptron (MLP) and Convolutional Neural Network (CNN) by varying their model sizes. Further, to better fit front-end electronics, neural network model reduction techniques, such as network pruning methods and variable-bit quantization approaches, were also studied. By combining pruning and quantization, our best performing model has the size of 1.5 KB, reduced from 16.6 KB of its full model counterpart. It can reach mean absolute error of 0.034 comparing to that of a naive baseline of 0.135. Such parameter-efficient and predictive neural network models established feasibility and practicality of their deployment on front-end ASICs.

47 OTHER INSTRUMENTATION↗

Dark Energy Survey Year 6 results: Redshift calibration of the MagLim++ lens sample

In this work, we derive and calibrate the redshift distribution of the MagLim++ lens galaxy sample used in the Dark Energy Survey Year 6 (DES Y6) 3 x 2pt cosmology analysis. The 3 x 2pt analysis combines galaxy clustering from the lens galaxy sample and weak gravitational lensing. The redshift distributions are inferred using the SOMPZ method - a Self-Organizing Map framework that combines deep-field multi-band photometry, wide-field data, and a synthetic source injection ( B alrog) catalog. Key improvements over the DES Year 3 (Y3) calibration include a noise-weighted SOM metric, an expanded Balrog catalogue, and an improved scheme for propagating systematic uncertainties, which allows us to generate O(10 8 ) redshift realizations that collectively span the dominant sources of uncertainty. These realizations are then combined with independent clustering-redshift measurements via importance sampling. The resulting calibration achieves typical uncertainties on the mean redshift of 1-2%, corresponding to a 20-30% average reduction relative to DES Y3. We compress the n(z) uncertainties into a small number of orthogonal modes for use in cosmological inference. Marginalizing over these modes leads to only a minor degradation in cosmological constraints. Here, this analysis establishes the MagLim++ sample as a robust lens sample for precision cosmology with DES Y6 and provides a scalable framework for future surveys.

dark energy↗