Search NASA⌕ Search

SEARCH · Search NASA

Results for “noninvasive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Morphological traits for allometric scaling of the European Sea Bass Dicentrarchus labrax (Linnaeus, 1758) from Southern Portugal population

Abstract The present study aimed to determine the allometric scaling among a selection of morphological traits in European sea bass ( Dicentrarchus labrax ) to estimate fish body weight. A set of morphological traits (fish body weight, length, height, and width) were directly measured in 146 fish of a recirculating aquaculture system, with body weights ranging from 17.11 to 652.21 g. In addition, a collection of digital imagery of each anesthetized fish from the side and top views were used to estimate other traits (indirect measures). Multiple regression analysis and regression coefficients were calculated using all possible combinations of biometric data (predictors) to estimate fish body weight, applying different numerical fitting models (linear, log‐linear, quadratic, exponential). The results showed that the best combination of traits for estimating fish body weight were fish body width, length and height, collected from direct measure ( R 2 = 0.995), for a log‐linear model fitting, which revealed more accurate determinations than the most commonly used length–weight relationship. Nevertheless, other combinations of morphological traits and fitting models were also found to be suitable in successfully predict fish body weight, with variability ranging between 92.5% and 98.5%. For indirect measures, the best predictor was a combination of traits from top view (width, eye distance and area without fins) fitted with a log‐linear function. These results comprise a relevant baseline in supporting the high potential of noninvasive methods to accurately follow the growth of European sea bass juveniles, recurring to imagery analysis of anesthetized fish. It has major potential applications in feeding consumption trials and fish growth models, as it allows for continuously following up fish growth under different experimental conditions without therein distress derived from manipulation.

Azevedo, Ana↗

Feasibility of Vascular Parameter Estimation for Assessing Hypertensive Pregnancy Disorders

Abstract Hypertensive pregnancy disorders (HPDs), such as pre-eclampsia, are leading sources of both maternal and fetal morbidity in pregnancy. Noninvasive imaging, such as ultrasound (US) and magnetic resonance imaging (MRI), is an important tool for predicting and monitoring these high risk pregnancies. While imaging can measure hemodynamic parameters, such as uterine artery pulsatility and resistivity indices (PI and RI), the interpretation of such metrics for disease assessment relies on ad hoc standards, which provide limited insight to the physical mechanisms underlying the emergence of hypertensive pregnancy disorders. To provide meaningful interpretation of measured hemodynamic data in patients, advances in computational fluid dynamics can be brought to bear. In this work, we develop a patient-specific computational framework that combines Bayesian inference with a reduced-order fluid dynamics model to infer parameters, such as vascular resistance, compliance, and vessel cross-sectional area, known to be related to the development of hypertension. The proposed framework enables the prediction of hemodynamic quantities of interest, such as pressure and velocity, directly from sparse and noisy MRI measurements. We illustrate the effectiveness of this approach in two systemic arterial network geometries: an aorta with branching carotid artery and a maternal pelvic arterial network. For both cases, the model can reconstruct the provided measurements and infer parameters of interest. In the case of the maternal pelvic arteries, the model can make a distinction between the pregnancies destined to develop hypertension and those that remain normotensive, expressed through the value range of the predicted absolute pressure.

Biophysics↗

Fast widefield imaging of neuronal structure and function with optical sectioning in vivo

Optical microscopy, owing to its noninvasiveness and subcellular resolution, enables in vivo visualization of neuronal structure and function in the physiological context. Optical-sectioning structured illumination microscopy (OS-SIM) is a widefield fluorescence imaging technique that uses structured illumination patterns to encode in-focus structures and optically sections 3D samples. However, its application to in vivo imaging has been limited. In this study, we optimized OS-SIM for in vivo neural imaging. We modified OS-SIM reconstruction algorithms to improve signal-to-noise ratio and correct motion-induced artifacts in live samples. Incorporating an adaptive optics (AO) module to OS-SIM, we found that correcting sample-induced optical aberrations was essential for achieving accurate structural and functional characterizations in vivo. With AO OS-SIM, we demonstrated fast, high-resolution in vivo imaging with optical sectioning for structural imaging of mouse cortical neurons and zebrafish larval motor neurons, and functional imaging of quantal synaptic transmission at Drosophila larval neuromuscular junctions.

42 ENGINEERING↗

Glove-based sensors for multimodal monitoring of natural sweat

Sweat sensors targeting exercise or chemically induced sweat have shown promise for noninvasive health monitoring. Natural thermoregulatory sweat is an attractive alternative as it can be accessed during routine and sedentary activity without impeding user lifestyles and potentially preserves correlations between sweat and blood biomarkers. We present simple glove-based sensors to accumulate natural sweat with minimal evaporation, capitalizing on high sweat gland densities to collect hundreds of microliters in just 30 min without active sweat stimulation. Sensing electrodes are patterned on nitrile gloves and finger cots for in situ detection of diverse biomarkers, including electrolytes and xenobiotics, and multiple gloves or cots are worn in sequence to track overarching analyte dynamics. Direct integration of sensors into gloves represents a simple and low-overhead scheme for natural sweat analysis, enabling sweat-based physiological monitoring to become practical and routine without requiring highly complex or miniaturized components for analyte collection and signal transduction.

42 ENGINEERING↗

NMR spectroscopy of coin cell batteries with metal casings

Battery cells with metal casings are commonly considered incompatible with nuclear magnetic resonance (NMR) spectroscopy because the oscillating radio-frequency magnetic fields (“rf fields”) responsible for excitation and detection of NMR active nuclei do not penetrate metals. Here, we show that rf fields can still efficiently penetrate nonmetallic layers of coin cells with metal casings provided “B 1 damming” configurations are avoided. With this understanding, we demonstrate noninvasive high-field in situ 7 Li and 19 F NMR of coin cells with metal casings using a traditional external NMR coil. This includes the first NMR measurements of an unmodified commercial off-the-shelf rechargeable battery in operando, from which we detect, resolve, and separate 7 Li NMR signals from elemental Li, anodic β-LiAl, and cathodic Li x MnO 2 compounds. Real-time changes of β-LiAl lithium diffusion rates and variable β-LiAl 7 Li NMR Knight shifts are observed and tied to electrochemically driven changes of the β-LiAl defect structure.

25 ENERGY STORAGE↗

Characterization, comparison, and optimization of lattice light sheets

Lattice light sheet microscopy excels at the noninvasive imaging of three-dimensional (3D) dynamic processes at high spatiotemporal resolution within cells and developing embryos. Recently, several papers have called into question the performance of lattice light sheets relative to the Gaussian sheets most common in light sheet microscopy. Here, we undertake a theoretical and experimental analysis of various forms of light sheet microscopy, which demonstrates and explains why lattice light sheets provide substantial improvements in resolution and photobleaching reduction. The analysis provides a procedure to select the correct light sheet for a desired experiment and specifies the processing that maximizes the use of all fluorescence generated within the light sheet excitation envelope for optimal resolution while minimizing image artifacts and photodamage. We also introduce a new type of “harmonic balanced” lattice light sheet that improves performance at all spatial frequencies within its 3D resolution limits and maintains this performance over lengthened propagation distances allowing for expanded fields of view.

59 BASIC BIOLOGICAL SCIENCES↗

Imaging beyond the surface region: Probing hidden materials via atomic force microscopy

Probing material properties at surfaces down to the single-particle scale of atoms and molecules has been achieved, but high-resolution subsurface imaging remains a nanometrology challenge due to electromagnetic and acoustic dispersion and diffraction. The atomically sharp probe used in scanning probe microscopy (SPM) has broken these limits at surfaces. Subsurface imaging is possible under certain physical, chemical, electrical, and thermal gradients present in the material. Of all the SPM techniques, atomic force microscopy has entertained unique opportunities for nondestructive and label-free measurements. Here, we explore the physics of the subsurface imaging problem and the emerging solutions that offer exceptional potential for visualization. We discuss materials science, electronics, biology, polymer and composite sciences, and emerging quantum sensing and quantum bio-imaging applications. The perspectives and prospects of subsurface techniques are presented to stimulate further work toward enabling noninvasive high spatial and spectral resolution investigation of materials including meta- and quantum materials.

74 ATOMIC AND MOLECULAR PHYSICS↗

Skin CO 2 sniffing for wearable metabolic monitoring

CO 2 is a key physiological parameter used to assess hypoventilation and to estimate metabolic rates. However, current CO 2 monitoring relies on bulky breath-analysis systems that are impractical for continuous use in daily life. Here, we present a wearable on-skin gas-sniffing system that quantifies skin-emitted CO 2 and establishes its physiological relevance through direct correlation with exhaled CO 2 and metabolic rate. Participant studies demonstrate strong correlations between CO 2 flow rates from the skin and breath during both rest and exercise, with skin-emitted CO 2 approximately four orders of magnitude lower than exhaled CO 2 . Skin-emitted CO 2 also correlates with metabolic rate, suggesting its potential as a surrogate for breath-based indirect calorimetry. With its wearable form factor and physiological relevance, this skin gas sniffing system enables continuous, noninvasive metabolic monitoring and opens opportunities for studying skin gas exchange.

Kim, Seung-Rok [University of California, Berkeley↗

Imaging quantum melting in a disordered 2D Wigner solid

Two-dimensional strongly interacting electrons crystalize into a solid phase known as the Wigner crystal at low densities and form a Fermi liquid at high densities. At intermediate densities, the two-dimensional solid evolves into a strongly correlated liquid phase around a critical density. We observed this quantum melting of a disordered Wigner solid in bilayer molybdenum diselenide (MoSe2) using a noninvasive scanning tunneling microscopy imaging technique. At low densities, the Wigner solid forms nanocrystalline domains pinned by local disorder. It exhibits a quantum densification behavior with increased densities in the solid phase. Above a threshold density, the Wigner solid melts locally and enters a mixed phase in which solid and liquid regions coexist. The liquid regions expand and form a percolation network at even higher densities.

Xiang, Ziyu↗

Adaptive Optical Two-Photon Fluorescence Microscopy Probes Cellular Organization of Ocular Lenses In Vivo

The mammalian ocular lens is an avascular multicellular organ that grows continuously throughout life. Traditionally, its cellular organization is investigated using dissected lenses, which eliminates in vivo environmental and structural support. Therefore, in vivo optical imaging methods for studying lenses in their native context in live animals are urgently needed. Here, we demonstrated that two-photon fluorescence microscopy can visualize lens cells in vivo. To maintain subcellular resolution at depth, we used adaptive optics to correct aberrations owing to ocular and lens tissues, which led to substantial signal and resolution improvements. Imaging lens cells up to 980 µm deep, we observed novel cellular organizations including suture-associated voids, enlarged vacuoles, and large cavities, contrary to the conventional view of a highly ordered organization. We tracked these features longitudinally over weeks and observed the incorporation of new cells during growth. Taken together, noninvasive longitudinal in vivo imaging of lens morphology using adaptive optics two-photon fluorescence microscopy will allow us to observe the development or alterations of lens cellular organization in living animals directly.

60 APPLIED LIFE SCIENCES↗

Proteomics identifies complement protein signatures in patients with alcohol-associated hepatitis

Diagnostic challenges continue to impede development of effective therapies for successful management of alcohol-associated hepatitis (AH), creating an unmet need to identify noninvasive biomarkers for AH. In murine models, complement contributes to ethanol-induced liver injury. Therefore, we hypothesized that complement proteins could be rational diagnostic/prognostic biomarkers in AH. Here, we performed a comparative analysis of data derived from human hepatic and serum proteome to identify and characterize complement protein signatures in severe AH (sAH). The quantity of multiple complement proteins was perturbed in liver and serum proteome of patients with sAH. Multiple complement proteins differentiated patients with sAH from those with alcohol cirrhosis (AC) or alcohol use disorder (AUD) and healthy controls (HCs). Serum collectin 11 and C1q binding protein were strongly associated with sAH and exhibited good discriminatory performance among patients with sAH, AC, or AUD and HCs. Furthermore, complement component receptor 1-like protein was negatively associated with pro-inflammatory cytokines. Additionally, lower serum MBL associated serine protease 1 and coagulation factor II independently predicted 90-day mortality. In summary, meta-analysis of proteomic profiles from liver and circulation revealed complement protein signatures of sAH, highlighting a complex perturbation of complement and identifying potential diagnostic and prognostic biomarkers for patients with sAH.

60 APPLIED LIFE SCIENCES↗

Acoustic sensing and autoencoder approach for abnormal gas detection in a spent nuclear fuel canister mock-up

Currently, spent nuclear fuel (SNF) from commercial nuclear power plants is stored in stainless-steel canisters for interim dry storage. To provide an inert environment, these canisters are backfilled with helium after vacuum drying. However, the helium environment may be contaminated during extended storage because of the material degradation. For example, the heavier fission gas xenon may be released from the fuel rods into the canister cavity should the fuel cladding be breached. Other gases such as air and water vapor may also be present as a result of leakage caused by chloride-induced stress corrosion cracking on the canister walls or by insufficient vacuum drying. Therefore, monitoring the gas composition can provide critical information about the health of SNF canisters. In this study, noninvasive testing was conducted on a 2/3-scaled SNF canister mock-up using acoustic sensing. Ultrasonic transducers were placed on the exterior surface of the canister to probe the gas composition. A dataset was collected by sealing the canister mock-up and introducing up to 1.53% argon or 1.29% air into the helium background gas. Three methods were used to detect changes in the gas composition: the time-of-flight (TOF) method, the differential method, and the autoencoder method. Results showed that the TOF method had sufficient resolution to detect abnormal gas concentrations of less than 1.0%. The differential method demonstrated a periodic in-phase and out-of-phase behavior between the benchmark (i.e., pure helium) and abnormal (i.e., with argon or air) state signals. The variational autoencoder (VAE) and the Wasserstein autoencoder (WAE) were trained on the benchmark data and were applied directly to the abnormal state data. It was found that both the unsupervised VAE and the WAE were able to distinguish the benchmark and abnormal states of the canister mock-up based on the reconstruction error.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Determining fast-S and slow-S propagation directions with SV-P data produced by buried explosives and recorded with vertical geophones

We have evaluated the concept of practicing S-wave reflection seismology with legacy 3D seismic data generated by a P-wave source and recorded with only vertical geophones. This type of S-wave imaging is based on the principle that seismic P-wave sources not only produce a downgoing illuminating P wavefield, but they also simultaneously produce a downgoing illuminating SV wavefield that, in almost all cases, is suitable for S-wave reflection imaging. The S-mode used in this study is the SV-P, or converted-P, mode. This mode involves a downgoing illuminating SV wavefield and an upgoing reflected P-mode that is recorded by vertical geophones. In flat-layered stratigraphy, the lengths of the SV and P raypaths in SV-P imaging are identical to the lengths of the SV and P raypaths in P-SV imaging with P-sources and 3C geophones. P-SV imaging of deep rocks has been practiced for more than two decades; SV-P imaging is a new concept. SV-P data should provide the same options for investigating deep rocks as do P-SV data. We have determined one of the equivalences between SV-P data extracted from vertical-geophone data and P-SV data extracted from horizontal geophones: that both modes react to azimuth-dependent variations in the S velocity in anisotropic rocks. Azimuthal variations in the SV-P traveltime can be used to define the polarization direction of the fast-S-wave mode, which is also the azimuth of the maximum horizontal stress (SHmax). Our investigation demonstrates a noninvasive method for monitoring changes in the SHmax azimuth across a CO 2 storage reservoir, or any targeted porous rock, as fluids are cycled into, and then out of, that rock’s pore space.

Geochemistry & Geophysics↗

Data for Miscanthus giganteus Biolistic Transformation Using the Visible RUBY Red Marker Gene to Monitor Transformation Efficiency

Miscanthus × giganteus ( M × g ) is a high- yielding perennial C4 bioenergy crop, but genetic improvement by breeding is constrained by triploid sterility and clonal propagation. Improving genetic transformation methods for M × g would provide opportunities for advantageous trait introgression. Use of an easy to phenotype reporter gene is a promising strategy to improve transformation processes and efficiency. This study presents an efficient novel method for biolistic transformation of inflorescence- derived callus in M × g and demonstrates its efficacy using RUBY, a betalain-based noninvasive reporter that is visible throughout the transformation process. RUBY expression ( Zea mays codon optimized) was visible from callus stage through plantlet development into maturity. RUBY expressing independently transformed plants were confirmed by hygromycin phosphotransferase ELISA and by genomic PCR demonstrating that the RUBY phenotype is sufficient for screening transformants. The Zea mays codon optimized hygromycin selection marker was driven by previously established promoters for Miscanthus, ZmUBI and 2×35S, while the RUBY gene expression was controlled by a known Zea mays C4 promoter, Brachypodium UBI10, newly employed in Miscanthus. The construct containing the 2×35S promoter for hygromycin had a 15.1% transformation efficiency while the ZmUBI promoter had a 20.5% transformation efficiency. This study provides a novel, highly efficient protocol for successful biolistic transformation of M × g for stable expression. This study also demonstrates that RUBY expression can be used as a convenient and powerful monitor of transformation in ongoing and future work to engineer M × g into an improved bioproduct feedstock. **NOTE: in "TableS2_ProtocolComparison.csv", the data from row 665 to 971 should be removed.

Gene Editing↗

TomoGAN: low-dose synchrotron x-ray tomography with generative adversarial networks: discussion

Synchrotron-based x-ray tomography is a noninvasive imaging technique that allows for reconstructing the internal structure of materials at high spatial resolutions from tens of micrometers to a few nanometers. In order to resolve sample features at smaller length scales, however, a higher radiation dose is required. Therefore, the limitation on the achievable resolution is set primarily by noise at these length scales. We present TomoGAN, a denoising technique based on generative adversarial networks, for improving the quality of reconstructed images for low-dose imaging conditions. We evaluate our approach in two photon-budget-limited experimental conditions: (1) sufficient number of low-dose projections (based on Nyquist sampling), and (2) insufficient or limited number of high-dose projections. In both cases, the angular sampling is assumed to be isotropic, and the photon budget throughout the experiment is fixed based on the maximum allowable radiation dose on the sample. Evaluation with both simulated and experimental datasets shows that our approach can significantly reduce noise in reconstructed images, improving the structural similarity score of simulation and experimental data from 0.18 to 0.9 and from 0.18 to 0.41, respectively. Furthermore, the quality of the reconstructed images with filtered back projection followed by our denoising approach exceeds that of reconstructions with the simultaneous iterative reconstruction technique, showing the computational superiority of our approach.

42 ENGINEERING↗

Nano-compositional imaging of the lanthanum silicide system at THz wavelengths

Terahertz scattering-type scanning near-field optical microscopy (THz-sSNOM) provides a noninvasive way to probe the low frequency conductivity of materials and to characterize material compositions at the nanoscale. However, the potential capability of atomic compositional analysis with THz nanoscopy remains largely unexplored. Here, we perform THz near-field imaging and spectroscopy on a model rare-earth alloy of lanthanum silicide (La–Si) which is known to exhibit diverse compositional and structural phases. We identify subwavelength spatial variations in conductivity that is manifested as alloy microstructures down to much less than 1 μ m in size and is remarkably distinct from the surface topography of the material. Signal contrasts from the near-field scattering responses enable mapping the local silicon/lanthanum content differences. These observations demonstrate that THz-sSNOM offers a new avenue to investigate the compositional heterogeneity of material phases and their related nanoscale electrical as well as optical properties.

47 OTHER INSTRUMENTATION↗

Transcranial Direct Current Stimulation (tDCS) Improves Empathy and Recognition of Facial Emotions Conveying Threat in Adults with Autism Spectrum Disorder (ASD): A Randomized Controlled Pilot Study

Introduction: Empathy is critical for human interactions to become shared and meaningful, and it is facilitated by the expression and processing of facial emotions. Deficits in empathy and facial emotion recognition are associated with individuals with autism spectrum disorder (ASD), with specific concerns over inaccurate recognition of facial emotion expressions conveying a threat. Yet, the number of evidenced interventions for facial emotion recognition and processing (FERP), emotion, and empathy remains limited, particularly for adults with ASD. Transcranial direct current stimulation (tDCS), a noninvasive brain stimulation, may be a promising treatment modality to safely accelerate and/or enhance treatment interventions to increase their efficacy. Methods: This study investigates the effectiveness of FERP, emotion, and empathy treatment interventions paired with tDCS for adults with ASD. Differences in scores on the Empathy Quotient (EQ) and on a FERP test were predicted for verum tDCS when compared to sham. Verum/sham tDCS was randomly assigned in a within-subjects, double-blinded design in adults with ASD without intellectual disability. Results: Verum tDCS significantly improved EQ scores and FERP scores for emotions that conveyed threat. Conclusions: These results suggest the potential for increasing the efficacy of treatment interventions by pairing them with tDCS for individuals with ASD.

59 BASIC BIOLOGICAL SCIENCES↗

Automatic Calibration of a Geomechanical Model from Sparse Data for Estimating Stress in Deep Geological Formations

Summary In this study, we demonstrate geomechanical modeling with fully automatic parameter calibration to estimate the full geomechanical stress fields of a prospective US carbon dioxide (CO2) storage site, based on sparse measurement data. The goal is to compute full stress tensor field estimates (principal stresses and orientations) that are maximally compatible with observations within the constraints of the model assumptions, thereby extending pointwise, incomplete partial stress measurement to a simulated full formation stress field, as well as a rough assessment of the associated error. We use the Perch site, located in Otsego County, Michigan, USA, as our case study. The input data consist of partial stress tensor information inferred from in-situ borehole tests, geophysical well logs, and processing of seismic data. A static earth model (SEM) of the site was developed, and geomechanical simulation functionality of the open-source MATLAB Reservoir Simulation Toolbox (MRST) was used to model the stress field. Adjoint-based nonlinear optimization was used to adjust boundary conditions and material properties to calibrate simulated results of observations. Results were interpreted through a Bayesian framework. The focus of this paper is to demonstrate how the fully automatic calibration procedure works and discuss the results obtained; it does not attempt a detailed analysis of the stress field in the context of the proposed CO2 storage initiatives. Our work is part of a larger effort to noninvasively determine in-situ stresses in deep formations considered for CO2 storage. Guided by previously published research on geomechanical model calibration, our work presents a novel calibration approach supporting a potentially large number of linear or nonlinear calibration parameters to produce results optimally agreeing with available measurements and thus extend partial pointwise estimates to full tensor fields compatible with the physics of the site.

Engineering↗