Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

LYNX: An unattended sensor system for detection of gamma-ray and neutron emissions from special nuclear materials

This manuscript profiles an unattended and fully autonomous detection system sensitive to gamma-ray and neutron emissions from special nuclear material. The LYNX design specifically targets applications that require radiation detection capabilities but possess little or no infrastructure. In these settings, users need the capability to deploy sensors for extended periods of time that analyze whatever signal-starved data can be captured, since little or no control may be exerted over measurement conditions. The fundamental sensing elements of the LYNX system are traditional NaI(Tl) and 3He detectors. The new developments reported here center on two themes: low-power electronics and computationally simple analysis algorithms capable of discriminating gamma-ray signatures indicative of special nuclear materials from those of naturally occurring radioactive material. Incorporating tripwire-detection algorithms based on gamma-ray spectral signatures into a low-power electronics package significantly improves performance in environments where sensors encounter nuisance sources.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

New intrinsically smart severe accident instrumentation saves costs and enhances severe accident management - 302

The Severe Accidents (SA) at Fukushima in 2011, identified the need for enhanced I and C to follow the progress of SA. Since SA environments are significantly Beyond DBA conditions, some new advanced Inherently Smart sensors had to be developed and tested. Nuclear plant designers and operators have helped focus the I and C enhancement based upon lessons learned from the Fukushima accidents. The result has been the addition of I and C for direct measurement of SA conditions hydrogen concentration, oxygen concentration, temperature, and pressure that provide unambiguous information for management of Severe Accident scenarios. The benefits are immediate from three important aspects. First, they deliver on the nuclear promise for enhanced safety at reduced costs. These Inherently Smart sensors have no maintenance and replace equipment that has high maintenance costs. Secondly, these sensors provide multiple benefits, such as condition monitoring information all the time and direct measurement of SA conditions if they are needed. Thirdly, and most importantly, simplify operator actions and training for SA. SA scenarios and SA Management can now rely on direct measurements to know such things as, the extent of fuel damage, integrity of the reactor pressure vessel, when corium is on the floor of containment, and conditions upon which to activate the hardened vent. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Condition monitoring and false alarm reducing of sensors in NPP - 222

With more and more application of digital I and C systems in nuclear power plants (NPP), more and more sensors are also required. Large amount of sensors really can make contribution to the condition monitoring of systems and equipment in NPP, whereas the heavy use also increases the malfunction risk of sensor self. Therefore the reliability and effectiveness of sensors must be guaranteed first. Thus the condition of sensors should be monitored first in a NPP. Since the precise mathematical models of sensors in complex systems are relative difficult to establish, however quantity of operating data can be easily obtained due to the wide application of digital I and C systems, thus this article adopts principal component analysis (PCA) to carry out condition monitoring for sensors. The PCA model developed for sensors is proved to be effective with operating data acquired from a real NPP. It can detect and isolate the fault when an artificial fault is imposed to the normal data. Then the monitoring results are further processed by another control limit (second confidence limit) besides T 2 and Q statistics (first confidence limit) in PCA. The value of second confidence limit is calculated based on the probability statistics of T 2 and Q statistics. And simulation tests show that the application of the second confidence limit can greatly reduce false alarms in the PCA model and the model performance can be greatly improved with the application of false alarms reducing method. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Robust Online Monitoring for Calibration Assessment of Transmitters and Instrumentation

Robust online monitoring (OLM) technologies are expected to enable the extension or elimination of periodic sensor calibration intervals in operating and new reactors. These advances in OLM technologies will improve the safety and reliability of current and planned nuclear power systems through improved accuracy and increased reliability of sensors used to monitor key parameters. In this article, we discuss an overview of research being performed within the Nuclear Energy Enabling Technologies (NEET)/Advanced Sensors and Instrumentation (ASI) program, for the development of OLM algorithms to use sensor outputs and, in combination with other available information, 1) determine whether one or more sensors are out of calibration or failing and 2) replace a failing sensor with reliable, accurate sensor outputs. Algorithm development is focused on the following OLM functions: • Signal validation • Virtual sensing • Sensor response-time assessment These algorithms incorporate, at their base, a Gaussian Process-based uncertainty quantification (UQ) method. Various plant models (using kernel regression, GP, or hierarchical models) may be used to predict sensor responses under various plant conditions. These predicted responses can then be applied in fault detection (sensor output and response time) and in computing the correct value (virtual sensing) of a failing physical sensor. The methods being evaluated in this work can compute confidence levels along with the predicted sensor responses, and as a result, may have the potential for compensating for sensor drift in real-time (online recalibration). Evaluation was conducted using data from multiple sources (laboratory flow loops and plant data). Ongoing research in this project is focused on further evaluation of the algorithms, optimization for accuracy and computational efficiency, and integration into a suite of tools for robust OLM that are applicable to monitoring sensor calibration state in nuclear power plants.

fault detection↗

Embedded Sensors and Controls to Improve Component Performance and Reliability - Final Report

Oak Ridge National Laboratory has researched embedded instrumentation and controls (I&C) for extreme environments under the Department of Energy, Office of Nuclear Energy's Nuclear Energy Enabling Technology program. Advanced sensors and controls have the potential to dramatically increase the performance and efficiency of nuclear reactor components, however, the extreme environments of exiting and advanced reactor designs limit the options for sensors, actuators, and control designs. To address two of the extreme environment challenges to embedded I&C, the focus of this research is to fill technology gaps needed for electromagnetic systems that can operate at temperatures greater than 700 C in corrosive environments. A magnetically suspended, canned-rotor pump was chosen for the embedded I&C development platform because it is a system with a practical need in industry and because the sensors, actuators, and embedded I&C technologies needed to successfully build this platform will be widely applicable to any high-temperature components that utilize electromagnetic interactions. This design also eliminates the need for pump seals and mechanical bearings which are the main sources of pump failures and maintenance costs. During the project a conceptual design for the high-temperature magnetically suspended pump was developed and analyzed for manufacturability and reliability. Specifications for the materials, control system, sensors, mechanical performance, high-temperature wiring, and electromagnetic properties were developed for the conceptual design. The canned rotor design of the high-temperature pump presents unique fluid force characteristics arising from the thin fluid channel between the rotor and stator. A model of the fluid forces was developed and the impact of these forces on the stability and performance of magnetic bearing controllers was studied. Then a room temperature bench-scale magnetic testbed was designed and fabricated for testing the performance of sensors and electromagnetic actuators, modern control design techniques, closed-loop system identification, state estimation, and model uncertainty. Finally, a loop-scale testbed with submerged magnetic bearings was designed and fabricated. This testbed will be used to analyze the stability and performance of control system designs in response to the nonlinear and cross-coupling fluid effects between the shaft axes of motion, rotordynamics, gyroscopic effects, and impeller disturbances.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Leak Detection and Sensor Importance Within a Solvent Extraction Process Abstract

In anticipation of the Special Nuclear Material test bed (Beartooth), Idaho National Laboratory has developed a smaller, multi-sensor system for analyzing the solvent extraction process. These systems will allow for research into nuclear fuel processing operations. The multi-sensor system consists of a row of centrifugal contactors and allows for measurement sources that are not traditionally used in the solvent extraction process to be explored including temperature, vibration, acoustics, pH, color, flow, and motor current. Currently, the solvent extraction process is very labor intensive and requires vigilant operators to identify the occurrence of leaks, which can be common during startup or after any change to the system. This study aims to locate leaks using non-traditional measurement sources then to identify which signals were of greatest importance in making this classification using Local Interpretable Model-agnostic Explanations. These results can be used to help solvent extraction process operators detect leaks and to inform future test beds designers to which sensors contain relevant, actionable information in this scenario.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of local-power-free, remote α -particle detection using optical fibers

We demonstrate the application of fluorescence optical fiber coupled to a telecom grade fiber as a sensor for alpha particles using alpha-specific ZnS(Ag) scintillation materials whose wavelength is down-shifted into a low-loss region of the telecom grade fiber transmission band. Telecom-grade fiber optics offer a solution for sensing alpha radiation in deep repositories and cask storage for radioactive materials due to the stability of SiO 2 under normal environmental conditions and its relative radiation hardness at low radiation doses. Long-term nuclear waste storage facilities require sensors for the detection of leakage of radioactive materials that are maintenance-free, do not require power and can survive with no ‘wear out’ mechanisms for decades. By accomplishing the wavelength transformation, we maximize efficiencies in the detection of α-particles and signal transport and can detect alpha scintillation at distances on the order of >1 km with a sensor that is ~3% efficient and can be easily scaled as a sensor array. This paper describes the construction and testing of the sensor including manufacture of the controlled thickness films, verification of the wavelength shift from 450 to 620 nm and optimization of the sensitivity as a function of thickness. We also model the relative sensitivity of the film as a function of film thickness, and we demonstrate a signal-to-noise ratio of 10 at a range of greater than 1 km.

alpha particles↗

Nuclear quadrupole resonance spectroscopy with a femtotesla diamond magnetometer

Radio frequency (RF) magnetometers based on nitrogen vacancy centers in diamond are predicted to offer femtotesla sensitivity, but previous experiments were limited to the picotesla level. We demonstrate a femtotesla RF magnetometer using a diamond membrane inserted between ferrite flux concentrators. The device provides ~300-fold amplitude enhancement for RF magnetic fields from 70 kHz to 3.6 MHz, and the sensitivity reaches ~70 fT√s at 0.35 MHz. The sensor detected the 3.6-MHz nuclear quadrupole resonance (NQR) of room-temperature sodium nitrite powder. The sensor’s recovery time after an RF pulse is ~35 μs, limited by the excitation coil’s ring-down time. The sodium-nitrite NQR frequency shifts with temperature as -1.00±0.02 kHz/K, the magnetization dephasing time is T 2 *=887±51 μs, and multipulse sequences extend the signal lifetime to 332±23 ms, all consistent with coil-based studies. Our results expand the sensitivity frontier of diamond magnetometers to the femtotesla range, with potential applications in security, medical imaging, and materials science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study on Application of Distributed Network of Sensors with List Mode for NMAC Literature Review

Nuclear material accounting and control (NMAC) for nuclear security detects, deters, and resolves questions related to unauthorized removal (i.e. theft) or misuse of nuclear material. NMAC also serves as a key insider threat mitigation measure and aids in recovery of nuclear material that is missing. Effective nuclear security depends on NMAC for timely and accurate information about nuclear material types, quantities, and locations. Bulk nuclear material processing facilities, however, present unique challenges for effective NMAC due to the presence of large quantities of material in-process and the accumulation of residual material holdup within process equipment. These holdup accumulations can obscure accurate physical inventory taking and complicate efforts to resolve NMAC irregularities at the facility level. Bulk material monitoring systems often rely on material balance calculations and indirect measurement techniques, which may mask protracted theft of smaller amounts of nuclear material. These monitoring limitations have generated increased interest in continuous monitoring technologies, including distributed non-destructive assay (NDA) sensor networks capable of providing real-time or near-real-time measurement of material movement and accumulation within bulk processing environments. Recent advancements in distributed networks of NDA radiation detectors and sensing technologies provide an opportunity to address these limitations. Although such distributed sensor networks have been implemented in select facilities for IAEA Safeguards applications, their potential for supporting NMAC functions specifically tailored to nuclear security objectives remains largely unexplored. Furthermore, emerging list-mode data acquisition technologies have reached high technology readiness levels, enabling time-correlated detection of nuclear events across multiple temporal scales. These capabilities provide enhanced opportunities for accurate holdup measurement, continuous process monitoring, and improved detection of material theft or misuse over time. The increasing global expansion of civil nuclear power and development of related bulk material processing facilities, including those supporting high-assay low-enriched uranium (HALEU) and other advanced reactor fuel fabrication, further increases the need for advanced measurement and monitoring strategies for NMAC.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Summary of Monitoring Station Component Evaluation Project 2009-2011

Sandia National Laboratories (SNL) is regarded as a center for unbiased expertise in testing and evaluation of geophysical sensors and instrumentation for ground-based nuclear explosion monitoring (GNEM) systems. This project will sustain and enhance our component evaluation capabilities. In addition, new sensor technologies that could greatly improve national monitoring system performance will be sought and characterized. This work directly impacts the Ground-based Nuclear Explosion Monitoring mission by verifying that the performance of monitoring station sensors and instrumentation is characterized and suitable to the mission. It enables the operational monitoring agency to deploy instruments of known capability and to have confidence in operational success. This effort will ensure that our evaluation capabilities are maintained for future use.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

REALIZATION OF A AUTOMATED T-WAY COMBINATORIAL TESTING APPROACH FOR A SOFTWARE BASED EMBEDDED DIGITAL DEVICE

Under the Department of Energy’s Light Water Reactor Sustainability Program, within the Plant Modernization research pathway, the Digital I&C Qualification Project is identifying new methods that would be beneficial in qualifying digital I&C systems and devices for safety-related usage. One such method that would be useful in qualifying field components such as sensors and actuators is the concept of testability. The Nuclear Regulatory Commission (NRC) considers testability to be one of two design attributes sufficient to eliminate consideration of software-based or software logic-based common cause failure (the other being diversity). The NRC defines acceptable “testability” as follows: Testability – A system is sufficiently simple such that every possible combination of inputs and every possible sequence of device states are tested and all outputs are verified for every case (100% tested). [NUREG 0800, Chapter 7, Branch Technical Position (BTP) 7-19] This qualification method has never proven to be practical in view of the very large number of combinations of inputs and sequences of device states for a typical I&C device. However, many of these combinations are not unique in the sense that they represent the same state space or in that that they represent state space that would not affect the critical design basis functions of the device. Therefore, the state space of interest might possibly be reduced to a manageable dimension through such analysis. This project will focus on a representative I&C device similar in design, function, and complexity to the types of devices that would likely be deployed in nuclear power plants as digital or software based sensors and actuators (e.g. Smart Sensors). Analysis will be conducted to determine the feasibility of testing this device in a manner consistent with the NRC definition. This report describes the development of test process for Bounded Exhaustive Testing with respect to Combinatorial Test (CT) methods. The report describes the candidate Device Under Test SW – the VCU smart sensor, conceptual experimental methods for stated test objectives, description of the process, tools, resources, and computing. This information will be used to fully develop a detailed test plan (based on statistical measure needs) and test environment for conducting an I&C device testability demonstration study. The future planed experimental study of this project is to demonstrate digital qualification via Bounded Exhaustive Testability with respect to Common Cause Failure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Defining and Characterizing Methods, Tools, and Computing Resources to Support Pseudo Exhaustive Testability of Software Based I&C Devices

Under the Department of Energy’s Light Water Reactor Sustainability Program, within the Plant Modernization research pathway, the Digital I&C Qualification Project is identifying new methods that would be beneficial in qualifying digital I&C systems and devices for safety-related usage. One such method that would be useful in qualifying field components such as sensors and actuators is the concept of testability. The Nuclear Regulatory Commission (NRC) considers testability to be one of two design attributes sufficient to eliminate consideration of software-based or software logic-based common cause failure (the other being diversity). The NRC defines acceptable “testability” as follows: Testability – A system is sufficiently simple such that every possible combination of inputs and every possible sequence of device states are tested and all outputs are verified for every case (100% tested). [NUREG 0800, Chapter 7, Branch Technical Position (BTP) 7-19] This qualification method has never proven to be practical in view of the very large number of combinations of inputs and sequences of device states for a typical I&C device. However, many of these combinations are not unique in the sense that they represent the same state space or in that that they represent state space that would not affect the critical design basis functions of the device. Therefore, the state space of interest might possibly be reduced to a manageable dimension through such analysis. This project focuses on a representative I&C device similar in design, function, and complexity to the types of devices that would likely be deployed in nuclear power plants as digital or software based sensors and actuators (e.g. Smart Sensors). Analysis will be conducted to determine the feasibility of testing this device in a manner consistent with the NRC definition. This report describes acceptable test methods, needed tools (existing or new), and computing resources, all based on engineering and computer science principles. This information will then be used in a later phase of this project to develop a test specification for I&C device testability that can be used in a future phase of this project to demonstrate digital qualification with respect to common cause failure. Following that, testing will be conducted and the results analyzed to determine if the methods employed are sufficient to eliminate consideration of software common cause failure in accordance with the concept of testability.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Remote monitoring of critical reactor parameters

A nuclear reactor instrumentation system monitors a nuclear power system that includes a reactor core within a reactor vessel and one or more sensors for monitoring parameters of the nuclear power system. The nuclear reactor instrumentation system includes a computer having a processor and configured to be powered by a normal power source and a backup power source; a wireless transmitter operable under the control of the processor; and a memory coupled to the processor and containing stored programming instructions. The stored programming instructions are executable by the processor to cause the processor to receive data from the sensors; identify a loss of normal power from the normal power source; and in response to identifying the loss of normal power, cause the wireless transmitter to transmit the received data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear data uncertainty propagation applied to the versatile test reactor conceptual design

We report the Versatile Test Reactor (VTR) currently under development is a 300 MWth sodium-cooled fast reactor (SFR) fueled with ternary metal alloy fuel, which aims to accelerate the testing of advanced nuclear fuels, materials, instrumentation, and sensors in high flux environments that are necessary to license the next generation of advanced reactor concepts. To support the VTR design process, uncertainties associated with the nuclear data has been propagated through the reactor core neutronics calculation to global parameters of interest, such as the core multiplication factor, kinetic parameters, and various reactivity feedback coefficients, following the sensitivity based uncertainty propagation approach. By folding the sensitivity coefficients, separately computed by the generalized perturbation theory code PERSENT and Monte Carlo code Serpent 2, with the variance-covariance matrices from COMMARA-2.0, we obtain the reaction-wise, isotope-wise, and overall uncertainties for each response of interest due to nuclear data uncertainty. With Serpent 2, the statistical error of the uncertainty is obtained by propagating the statistical error of the sensitivity coefficients through the same process using a newly developed uncertainty propagation method. From both codes, the overall top uncertainty contributors are found to be the cross section of Fe-56 elastic scattering, Na-23 elastic scattering, and U 238 inelastic scattering. The large contributions of the Fe-56 elastic scattering cross sections to global parameters are due to its relatively large relative uncertainty of 5–10% in nuclear data and the large volume of Fe-containing reflector assemblies in the fairly compact VTR core design. Both codes agreed well for the overall uncertainty estimates of all responses of interest, except the delayed neutron fraction, prompt neutron generation time, and the coolant density feedback coefficient, where Serpent 2 yielded a much larger value than PERSENT due to the large statistical error of sensitivity coefficients. The calculated uncertainties are also compared to those associated with other SFR cores. Another outcome of this study is a variance-covariance matrix of reactivity coefficients, which can be used in the subsequent uncertainty propagation to the system level to investigate the impact of identified uncertainties on system responses in the safety analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Note: Real time optical sensing of alpha-radiation emitting radioactive aerosols based on solid state nuclear track detector

A sensitive radioactive aerosols sensor has been designed and developed. Its design guidance is based on the need for a low operational cost and reliable measurements to provide daily aerosol monitoring. The exposure of diethylene-glycol bis (allylcarbonate) to radiation causes modification of its physico-chemical properties like surface roughness and reflectance. In the present study, optical sensor based on the reflectance measurement has been developed with an aim to monitor real time presence of alpha radioactive aerosols emitted from thorium nitrate hydrate. The results shows that the fabricated sensor can detect 0.0157 kBq to 0.1572 kBq of radio activity by radioactive aerosols generated from (Th(NO{sub 3}){sub 4} ⋅ 5H{sub 2}O) at 0.1 ml/min flow rate. The proposed instrument will be helpful to monitor radioactive aerosols in/around a nuclear facility, building construction sites, mines, and granite polishing factories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Designing a TAC thermometer from a VHTR graphite structure

The interior of a nuclear reactor presents a particularly harsh and challenging environment for both sensors and telemetry due to high temperatures and high fluxes of energetic and ionizing particles among the radioactive decay products. Very High Temperature Reactors are pushing the in core temperatures even higher. A unique sensing approach will be discussed to address the necessary high temperature measurements. Thermoacoustic thermometry exploits high temperatures and uses materials that are immune to the effects of ionizing radiation to create a temperature sensor that is self-powered and wireless. In addition, the form-factor for the Thermoacoustic Thermometer (TACT) can be designed to be integrated within common in-pile structures. There are no physical moving parts required for TACT and the sensor is self-powered, as it uses the nuclear fuel for its heat source. TACT data will be presented from a laboratory prototype mimicking the design necessary for a VHTR graphite structure.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Enhanced Design of Radiation Tolerant High-Temperature Structural Health Monitoring Sensors

Acoustic emission sensors are vital in the nuclear industry for real-time structural health monitoring and early detection of material degradation. By capturing high-frequency stress waves emitted from defects like cracks, corrosion, or fatigue, acoustic emission sensors enable non-invasive monitoring of critical components such as reactor vessels, piping, and containment structures. This technology supports predictive maintenance, enhances safety, and ensures regulatory compliance by providing early warnings of potential failures. It is also instrumental in research, particularly in material testing reactors, where it is used to monitor the behavior of fuels and materials under irradiation, by allowing the detection of cracking or other acoustic signals in real time. This enables the evaluation of performance and accident behavior of advanced fuel concepts.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗