Replaceable Paddle Tip Fabrication and Testing for Saltstone Production Facility (SPF) Mixer (FY2020 Update)

Details of the operations and issues related to the paddles used in the Saltstone Production Facility (SPF) employing the 10-inch READCO ™ -Kurimoto co-rotating dual shaft continuous mixer are provided in SRNL-ST1-2019-00142, Based on a recent effort performed by the Savannah River National Laboratory (SRNL) and funded by Savannah River Remediation (SRR), eight different replaceable paddle designs were proposed and the angled notched design was selected for this study. This design was selected over the other designs due to its simplicity and its ability to meet the fitness of duty requirements. There are two types of angled notched replaceable tip designs, one being flat and the other helical. Either of these designs can be used for blending the premix with the salt solution. Stress calculations performed on this design (the use of the bolts and connections) are documented in M-CLC-Z-00137 showing it was suitable for use.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Site Revegetation Monitoring Report for Fiscal Year 2025

Revegetation of remediated and disturbed areas on the Hanford Site is performed to support U.S. Department of Energy, Hanford Field Office’s goal of meeting cleanup and revegetation requirements mandated in the Comprehensive Environmental Response, Compensation, and Liability Act of 1980. Revegetation and monitoring activities are conducted in accordance with DOE/RL-2011-116, Hanford Site Revegetation Manual , area-specific revegetation plans, mitigation action plans, and memorandums of agreement.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Infrequent Samples from the Concentration, Storage, and Transfer Facility: H-Area Diversion Box 7 (HDB-7) Sump Sample: January 2022 Samples

Savannah River Remediation Engineering (SRR-E) requested that the Savannah River National Laboratory (SRNL) analyze the Concentration, Storage, and Transfer Facility (CSTF) samples from the following Tank Farm areas: the sump encasement, catch tank, drain cell, and waste tank annulus. In general, these CSTF samples will be analyzed on an infrequent basis and analyses will include detection for total beta/gamma, total alpha activities, density, free hydroxide, and pH measurements. This report presents characterization results for the H-Area diversion box 7 sump (HDB-7) 07 January 2022 and 18 January 2022 samples. The samples were clear and colorless and free from any solids. The results are measurements for total gamma, total alpha, total beta, density, free hydroxide, and pH.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results for the Fourth Quarter Calendar Year 2018 Tank 50 Salt Solution Sample

In this Technical Report, the chemical and radionuclide contaminant results from the Fourth Quarter Calendar Year 2018 (CY18) sample of Tank 50 salt solution are presented in tabulated form. The information from this characterization will be used by Savannah River Remediation (SRR) for the transfer of aqueous waste from Tank 50 to the Saltstone Production Facility (SPF), where the waste will be treated and disposed in the Saltstone Disposal Facility. This Technical Report compares results, where applicable, to SPF Waste Acceptance Criteria (WAC) Limits and Targets. The chemical and radionuclide contaminant results from the characterization of the Fourth Quarter CY18 sampling of Tank 50 were requested by SRR personnel via a Task Technical Request (TTR) and details of the testing are presented in the Savannah River National Laboratory (SRNL) Task Technical and Quality Assurance Plan (TTQAP). This Technical Report is part of Deliverable 2 relating to Task 1 from the SRR request. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals will be documented at a later time per the TTQAP for the Tank 50 Saltstone task.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of Radiological Contamination at Parks in the Gateway National Recreation Area - 20350

In 2005, the National Park Service was notified that elevated radiation levels were detected at Great Kills Park during a baseline radiological mapping effort conducted by the Counter Terrorism Bureau of the New York City Police Department and the United States Department of Energy. Great Kills Park is in the Staten Island Unit of the Gateway National Recreation Area. A records search determined that approximately 280 acres of the park was established over an area in which the New York City Department of Sanitation placed approximately 15.1 million cubic yards of waste fill from 1944 to 1948. Since 2005, a series of response actions and investigations were conducted on behalf of the National Park Service to mitigate risk to human health and the environment and to determine the nature of radiological contamination at Great Kills Park. The findings support that radiological contamination is related to certain components of waste fill, including incinerator residue from both on and offsite incinerators, coal ash from the historical use of coal-fired boilers for heating, and incidental radiological artifacts in the waste fill due to their historical use and subsequent disposal. A majority of the radiological artifacts were determined to contain radium-226 and included radioluminescent markers, radium impregnated switch board buttons, radium paint containers, and brachytherapy devices. The National Park Service has several other Parks in the Gateway National Recreation Area that were established in areas with a similar history to Great Kills Park, and overlie waste fill historically placed during landfilling operations, including Spring Creek Park and Dead Horse Bay. Over the last year, the National Park Service has performed additional radiological investigations at Great Kills Park as part of the ongoing Remedial Investigation under the Comprehensive Environmental Response, Compensation, and Liability Act. In addition, preliminary radiological investigations were performed at Spring Creek Park and Dead Horse Bay Park in the Jamaica Bay Unit of Gateway National Recreation Area. These investigation activities identified gamma radiation levels above the ambient level, several of which were attributable to radiological artifacts similar in nature to those recovered at Great Kills Park. Ongoing investigations at Parks in the Gateway National Recreation Area support an association between radiological contamination and historical landfilling practices that were common prior to the regulation and control of radioactive materials. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of the lgnitability Hazards in Remediated Nitrate Salt Waste

The hazards associated with the characteristic of ignitability in remediated nitrate salt (RNS) waste containing nitric acid (HNO 3 ) and metal nitrate salts, currently stored at the Waste Control Specialists (WCS) facility near Andrews, Texas have been evaluated. For these waste drums there are two ignitability hazards that may apply, each separately distinguished from the other and uniquely correlated to one of two competing reaction mechanisms. One ignitability hazard, designated the autocatalytic thermal runway, is uniquely correlated to an acid/base reaction of hydrolysis of a hydrated metal nitrate salt. The other applicable ignitability hazard, designated the oxidizer property, is uniquely correlated to a redox disproportionation reaction involving an anhydrous metal nitrate salt. Which reaction mechanism pathway is accessible to a given metal nitrate, and therefore which ignitability hazard may apply, depends on the acidity of the metal ion and its corresponding capacity to maintain coordination with water.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Infrequent Samples from the Concentration, Storage, and Transfer Facility: H-Area Diversion Box 1 (HDB-1) Sump Sample: January 25, 2022 Sample

Savannah River Remediation Engineering (SRR-E) requested that the Savannah River National Laboratory (SRNL) analyze the Concentration, Storage, and Transfer Facility (CSTF) samples from the following Tank Farm areas: the sump encasement, catch tank, drain cell, and waste tank annulus. In general, these CSTF samples will be analyzed on an infrequent basis and analyses will include detection for total beta/gamma, total alpha activities, density, free hydroxide, and pH measurements. This report presents characterization results for the H-Area diversion box 1 sump (HDB-1) January 2022 sample. The sample was slightly brown with a small amount of suspended fine particulates visually estimated to be less than 1% by volume. The results are measurements for total gamma, total alpha, total beta, density, free hydroxide, and pH.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

200-DV-1 Laboratory Treatability Study: Proof-of-Principle Results

This document presents the Phase 1 technical approach and results of laboratory-scale treatability testing of nine in situ remedial technologies for their consideration in a future Feasibility Study (FS) for the 200-DV-1 OU. The primary objective of this initial assessment was a proof-of-principle testing evaluation primarily via batch experiments to determine the potential reduction and sequestration of primary contaminants of interest with and without potential co-contaminants of interest. An effectiveness rate of 35% transformation to immobile or nontoxic end products, along with other experimental indicators, was used by the project team to determine the technologies that advanced to Phase 2 for further evaluations. For most technologies, the performance was evaluated based on a series of sequential extractions designed to evaluate the mobility of contaminants before and after treatment, with each subsequent extraction representing a relative decrease in mobility. The results of this study will be used to inform testing for Phase 2 of the treatability study for further evaluation of selected technologies. The final results from the treatability study, following the completion of remaining experimental phases, will be used to determine whether the technologies tested can be appropriately evaluated in a FS to expand on the limited number of viable DVZ remediation technologies. After completion of the laboratory treatability study and the 200-DV-1 OU Remedial Investigation (RI) and Resource Conservation and Recovery Act Facility Investigation (RFI) of the waste sites, results will be evaluated to determine whether field studies are needed to provide additional information on effectiveness, implementability, or costs for evaluating these technologies in the FS for their site-specific application.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Review of Carbon-14 Removal by Ion Exchange Resins and Potential Remediation Application in the 100-K Area

During operations at the U.S. Department of Energy Hanford Site, releases of chemical and radioactive waste resulted in contamination of the soil and groundwater beneath portions of the site, including inadvertent releases of carbon-14 in the 100-K Area. Ongoing environmental cleanup efforts in the 100-K Area are focused on hexavalent chromium [Cr(VI)] and thus have not yet addressed the two carbon-14 groundwater plumes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Permanganate Oxidation of Actual Defense Waste Processing Facility (DWPF) Slurry Mix Evaporator Condensate Tank (SMECT) and Offgas Condensate Tank (OGCT) Samples to Remediate Glycolate

Savannah River Remediation (SRR) tasked Savannah River National Laboratory (SRNL) to examine glycolate destruction in radioactive samples emulating the proposed process. Experiments with radioactive Defense Waste Processing Facility (DWPF) condensates were performed to demonstrate the oxidation of glycolate using sodium permanganate. One test each was performed for Off-Gas Condensate Tank (OGCT) and Slurry Mix Evaporator Condensate Tank (SMECT) samples received. Condensates were blended with Recycle Collection Tank (RCT) heel simulant and Slurry Mix Evaporator (SME) product containing glycolate to represent typical RCT compositions with estimated nominal entrainment of glycolate. A permanganate to glycolate (P/G) molar ratio targeting 5.7 decreased sample glycolate concentration below Ion Chromatography (IC), glycolate method reporting limits in less than 2 hours for the OGCT sample and in less than 8 hours for the SMECT sample.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank 50 Salt Solution Sample (2QCY21)

In this Technical Report, the chemical and radionuclide contaminant results from the Second Quarter Calendar Year 2021 (CY21) sample of Tank 50 salt solution are presented in tabulated form. The information from this characterization will be used by Savannah River Remediation (SRR) for the transfer of aqueous waste from Tank 50 to the Saltstone Production Facility (SPF), where the waste will be treated and disposed in the Saltstone Disposal Facility. This Technical Report compares results, where applicable, to SPF Waste Acceptance Criteria (WAC) Limits and Targets that were established at the time the Tank 50 sample was obtained. The chemical and radionuclide contaminant results from the characterization of the Second Quarter CY21 sampling of Tank 50 were requested by SRR personnel via a Task Technical Request (TTR) and details of the testing are presented in the Savannah River National Laboratory (SRNL) Task Technical and Quality Assurance Plan (TTQAP). This Technical Report is part of Deliverable 2 relating to Task 1 from the SRR request. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals per Task 2 from the SRR request, will be obtained semi-annually for the 1QCY21 and 3QCY21 Tank 50 samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results for the Third Quarter Calendar Year 2021 Tank 50 Salt Solution Sample

In this Technical Report, the chemical and radionuclide contaminant results from the Third Quarter Calendar Year 2021 (CY21) sample of Tank 50 salt solution are presented in tabulated form. The information from this characterization will be used by Savannah River Remediation (SRR) for the transfer of aqueous waste from Tank 50 to the Saltstone Production Facility (SPF), where the waste will be treated and disposed in the Saltstone Disposal Facility. This Technical Report compares results, where applicable, to SPF Waste Acceptance Criteria (WAC) Limits and Targets that were established at the time the Tank 50 sample was obtained. The chemical and radionuclide contaminant results from the characterization of the Third Quarter CY21 sampling of Tank 50 were requested by SRR personnel via a Task Technical Request (TTR) and details of the testing are presented in the Savannah River National Laboratory (SRNL) Task Technical and Quality Assurance Plan (TTQAP). This Technical Report is part of Deliverable 2 relating to Task 1 from the SRR request. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals per Task 2 from the SRR request, will be obtained semi-annually for the 1QCY21 and 3QCY21 Tank 50 samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results for the Second Quarter Calendar Year 2021 Tank 50 Salt Solution Sample

In this Technical Report, the chemical and radionuclide contaminant results from the Second Quarter Calendar Year 2021 (CY21) sample of Tank 50 salt solution are presented in tabulated form. The information from this characterization will be used by Savannah River Remediation (SRR) for the transfer of aqueous waste from Tank 50 to the Saltstone Production Facility (SPF), where the waste will be treated and disposed in the Saltstone Disposal Facility. This Technical Report compares results, where applicable, to SPF Waste Acceptance Criteria (WAC) Limits and Targets that were established at the time the Tank 50 sample was obtained. The chemical and radionuclide contaminant results from the characterization of the Second Quarter CY21 sampling of Tank 50 were requested by SRR personnel via a Task Technical Request (TTR) and details of the testing are presented in the Savannah River National Laboratory (SRNL) Task Technical and Quality Assurance Plan (TTQAP). This Technical Report is part of Deliverable 2 relating to Task 1 from the SRR request. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals per Task 2 from the SRR request, will be obtained semi-annually for the 1QCY21 and 3QCY21 Tank 50 samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank 50 Simulant Grout and Toxicity Characteristic Leaching Procedure (TCLP) Results for Methyl Mercury Waste Acceptance Criteria (WAC) Limit

Testing of simulated Tank 50 salt solution grout, spiked with methyl mercury (MeHg) and ionic mercury, used the Toxicity Characteristic Leaching Procedure (TCLP) to evaluate leaching performance with respect to Hg and the Waste Acceptance Criteria (WAC) limits for the Saltstone Production Facility (SPF). This report describes the test parameters for simulant preparation and confirmatory analysis, grout preparation, TCLP leach testing and subsequent leachate analyses. These scoping tests were designed to provide an initial evaluation of the effect of increased MeHg and ionic Hg on the TCLP and were requested by Savannah River Remediation LLC (SRR) through a Technical Assistance Request (TAR). It is expected that this preliminary testing will likely lead to future, more detailed, testing involving the mercury (Hg) WAC and Hg limits with respect to the Tank 50 TCLP for mercury. The TCLP concentrations for total Hg have approached 0.06 mg/L in recent years for Tank 50 radioactive solutions containing up to 105 mg/L of Hg in the form of ionic (Hg(I/II), elemental (Hg(0)) and organo-mercury such as MeHg. In discussions with SRR personnel, it was decided for this non-baseline work to target Hg spike concentrations, using predominately MeHg, in the range of 150 to 350 mg/L total Hg to investigate corresponding Hg TCLP leaching behaviors.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of semivolatile organics in liquid radioactive residue using sorptive stir bar and solvent back-extraction

Current methods for semivolatiles analysis in radioactive samples can produce large volumes of radioactive solvent residue. A method utilizing stir-bar sorptive extraction has been explored in this work for its applicability to radioactive waste samples. This low solvent analytical method may accelerate remediation, minimize hazardous solvent waste, and reduce exposure risk to workers. Organic compounds (polyaromatic hydrocarbons, chlorinated aromatics, and phenolic compounds) were chosen as surrogates for common Liquid Waste System (LWS) contaminants at Savannah River Site (Aiken, SC). Stir-bar extraction parameters (extraction time, matrix modification, and effective pH range) and solvent back extraction parameters (solvent type, volume, and extraction time) were optimized experimentally for the chosen compounds. Affinity of the stir-bar extraction polymer to radionuclides Cs-137 and Am-241 was observed to determine radionuclide concentration effects. The stir-bar method achieved mean recovery of 100 ± 0.7% (1σ), relative to 114 ± 7% using solvent extraction, while reducing weekly method hands-on time by 93.4% and solvent volume consumption by 99.3%. Sensitivity was improved by 378% in simulated tank waste and 278% in real-world LWS matrix, relative to solvent extraction. This work has produced a safe and optimized method for the low solvent analysis of organics in legacy radioactive tank waste by stir-bar sorptive extraction.

GC-MS↗

Application of a Null-Space Monte Carlo Flow Model Set to the Composite Analysis Base Case Fate and Transport Modeling

The Plateau-to-River (P2R) Model is a groundwater flow and contaminant fate and transport (F&T) simulation model used to support remedial activities conducted by Central Plateau Cleanup Company (CPCCo) at the Hanford Site in Washington State. Figure 1 illustrates the P2R Model extents, discretization, and boundary conditions. The P2R Model is utilized in the composite analysis (CA) for the Hanford Site as the computational engine for computing F&T predictions as described in CP-60406, Hanford Site Composite Analysis Technical Approach Description: Groundwater. The model simulates contaminants of concern within the saturated zone of the uppermost aquifer beneath the Central Plateau and downgradient to the Columbia River. CP-57037, Model Package Report for the Plateau to River Model Version 8.3 documents the current version of the P2R Model including a description of the conceptual site model, model development and calibration, and limitations to the model application.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Predictive Contaminant Transport Simulation with the P2R Model for the Composite Analysis Inventory Sensitivity Case

The Plateau to River (P2R) Model is a groundwater flow and contaminant fate and transport (F&T) simulation model used to support remedial activities conducted by the Central Plateau Cleanup Company (CPCCo) at the Hanford Site in Washington State. The model simulates contaminants of concern within the saturated zone of the uppermost aquifer beneath the Central Plateau and downgradient to the Columbia River. The overall objective of the saturated zone modeling effort is to provide a basis for making informed remedial action decisions based on descriptions of current and expected future contaminant concentrations in groundwater at decision points within and downgradient of the Central Plateau of the Hanford Site. Specifically, the purpose of this environmental calculation file (ECF) is to describe an inventory sensitivity case of the CA base case. The inventory sensitivity case implements a change in the activity contribution from the vadose zone in the A Trenches Area model (for tritium (H-3) and iodine-129 (I-129)), BC Cribs and Trenches model (for I-129 and technetium-99 (Tc-99)), and the PUREX Area model (for H-3 and I-129). All other simulated inventories are identical to the CA base case. The simulation of F&T of contaminants reported in this case will support dose predictions as part of the Hanford Site CA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Soil Gas Survey Results Supporting Groundwater Correction Action Plan (GCAP) Development for the Moab Site

A soil gas survey was performed at the Moab Uranium Mill Tailings Remedial Action (UMTRA) Project Site during the week of November 6, 2023. Soil gas surveys are used to characterize residual subsurface sources of volatile contaminants, such as volatile organic compounds, as well as contaminants that generate a surrogate indicator gas or otherwise influence soil gas composition. The primary objective of the Moab soil gas survey was to confirm, identify, quantify, and refine secondary contaminant source area locations for uranium and ammonium/ammonia (NH 4 + /NH 3 ) in the vadose zone and shallow groundwater. The overarching goal was to provide information to assist in developing the technical basis for the Groundwater Compliance Action Plan (GCAP). Specifically, the soil gas data will support the deployment of source control technologies; e.g., where supplementary capping, removal actions, or amendments might be beneficial.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗