Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Systems and methods for optical measurement of cross-wind

Various technologies pertaining to optical measurement of cross-wind are described herein. A beam of light is emitted along a trajectory through a shooting space from a location of a shooter to a target using a laser. The beam is reflected by the target, and the beam is received at two optical detectors. Due to changes in the index of refraction of air along the path of the beam, an envelope signal atmospherically encoded on the beam is received at each of the two apertures at different times. A signal analyzer receives a signal from each of the detectors and outputs data indicative of an average speed of the cross-wind along the trajectory in the shooting space based upon a time delay between the signals.

Bagwell, Brett↗

Dew point meter, components thereof, and methods of use thereof

In one aspect, the present disclosure is directed to a sample cell for a dew point meter, the sample cell comprising: a flow channel configured to receive a gas sample, the flow channel comprising: a non-mirror window surface, wherein the flow channel is configured to allow a first optical beam originating from an optical source to impinge on the non-mirror window surface and output a second optical beam from the non-mirror window surface towards an optical detector.

Cheng, Mao↗

Making Optical-Fiber Chemical Detectors More Sensitive

Calculations based on exact theory of optical fiber shown how to increase optical efficiency and sensitivity of active-cladding step-index-profile optical-fiber fluorosensor using evanescent wave coupling. Optical-fiber fluorosensor contains molecules fluorescing when illuminated by suitable light in presence of analyte. Fluorescence coupled into and launched along core by evanescent-wave interaction. Efficiency increases with difference in refractive indices.

Rogowski, Robert S.↗

Thin-film lithium niobate electro-optic terahertz wave detector

Here, the design, fabrication, and validation of a thin-film lithium niobate on insulator (LNOI) electro-optic (EO) time-domain terahertz (THz) wave detector is reported. LNOI offers unprecedented properties for the EO detection of freely propagating THz wave radiation pulses and transient electric fields because of the large EO coefficient of the material, engineering of the velocity matching of the THz wave and optical wave, and much reduced detector size. The proof-of-concept device is realized using thin-film lithium niobate optical waveguides forming a Mach–Zehnder interferometer with interferometer arms electrically poled in opposite directions. THz waves are coupled effectively to the fully dielectric device from free space without using antennas or plasmonics. The detection of THz waves with frequencies up to 800 GHz is successfully demonstrated. The detector allows for the detection of THz frequency electric fields up to 4.6 MV/m. The observed frequency response of the device agrees well with theoretical predictions.

47 OTHER INSTRUMENTATION↗

CMOS detector cells for holographic optical interconnects in microcircuits

This paper reports on the characterization of CMOS detectors for holographic optical interconnects in micro circuits. A VLSI temporal response system has been built, which has high-magnification viewing capabilities to facilitate the identification of the sample area under investigation. An isolated photodiode and load circuit has been characterized to determine responsivity, response time, and light spot positioning effects. The threshold of optical gate cells incorporating the above detectors and a transistor inverter stage to couple to other circuitry has been determined. The rise time and fall time of the optical gate cells have also been determined experimentally. The results were compared with the results of SPICE simulation, and show satisfactory agreement. The time delay of optical gate cell output was thus determined to be 70 ns at 10 microW light input. Threshold power was 0.5 microW light input.

Wu, W. H.↗

System and method for focal-plane illuminator/detector (FASID) design for improved graded index lenses

The present disclosure relates to a detector system for imaging an optical signal received by a graded index (GRIN) optical element to account for known variations in a graded index distribution of the GRIN optical element. The detector system incorporates a plurality of optical detector elements configured to receive optical rays received by the GRIN optical element at specific locations on a plane of the GRIN optical element. Ray tracing software is configured to receive and map the optical rays to a plurality of additional specific locations on the plane based on the known variations in the graded index distribution of the GRIN optical element. A processor uses algorithms for diagonalization of a linear system matrix to determine information on both an intensity and an angle of the received optical rays at each one of the plurality of specific locations on the plane.

Bude, Jeffrey Devin↗

A spectrometric approach to measuring the Rayleigh scattering length for liquid scintillator detectors

Good optical transparency is a fundamental requirement of liquid scintillator (LS) detectors. Characterizing the transparency of a liquid scintillator to its own emitted light is a key parameter to determine the overall sensitivity of a large-volume detector. The attenuation of light in an optical-pure LS is dominated by Rayleigh scattering, which poses an intrinsic limit to the transparency of LS. This work presents a spectrometric approach of measuring the wavelength-dependent scattering length of liquids by applying the Einstein-Smoluchowski theory to a measurement of scattered light intensity. The scattering lengths of linear alkyl benzene (LAB) and EJ309-base (Di-isopropylnaphthalene, DIN) were measured and are reported in the wavelength range of 410–520 nm. The spectral peak of scintillation light emitted by a nominal LS is around 430 nm at which the scattering lengths for LAB and EJ-309-base were determined to be 27.9 ± 2.3 m and 6.1 ± 0.6 m.

47 OTHER INSTRUMENTATION↗

Snowmass Neutrino Frontier NF10 Topical Group Report: Netrino Detectors

We discuss here future neutrino detectors with physics goals ranging from the eV to the EeV scale. The focus is on future enabling technologies for such detectors, rather than existing detectors or those under construction. The report includes methodologies across the broad spectrum of neutrino physics: liquid noble and other cryogenic detectors, including LAr and LXe TPCs; photon-based detectors including technologies enabling hybrid Cherenkov/scintillation detectors; low-threshold detectors which use a wide variety of technologies to probe physics like coherent neutrino-nucleus scattering or detection of cosmic background neutrinos; and ultra-high energy detectors including optical and radio detectors, as well as tracking detectors for use at the forward physics facility of the LHC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simons Observatory: Characterization of the Large Aperture Telescope Receiver

The Simons Observatory (SO) is a ground-based cosmic microwave background (CMB) survey experiment that currently consists of three 0.42 m small-aperture telescopes and one 6 m large-aperture telescope (LAT), located at an elevation of 5200 m in the Atacama Desert in Chile. At the LAT’s focal plane, SO will install >62,000 transition-edge sensor detectors across 13 optics tubes (OTs) within the Large Aperture Telescope Receiver (LATR), the largest cryogenic camera ever built to observe the CMB. Furthermore we report on the validation of the LATR in the laboratory and the subsequent dark testing and validation within the LAT. We show that the LATR meets cryogenic, optical, and detector specifications required for high-sensitivity measurements of the CMB. At the time of writing, the LATR is installed in the LAT with six OTs (corresponding to >31,000 detectors), and the LAT mirrors and remaining seven OTs are undergoing development.

Astronomical instrumentation↗

New screening methodology to select low outgassing materials for cold, spaceborne optical instruments

Standardized techniques for outgassing tests are developed and set forth for use in the screening of materials for aerospace instruments with cooled sensors, optics, and/or detectors. Materials for optical instruments are discussed in terms of molecular outgassing, and material-outgassing test results are presented which relate to several test conditions. The existing outgassing standard is found to be inadequate, and revised outgassing standards related to four application levels are given. The test protocols are designed for the development of materials for optical instruments that operate in environments with temperatures below 20 C. Consideration is also given to potential molecular contamination in the space environment and to outgas screening of instruments with a variety of sensor/optics/detector temperatures. The standards are designed for use with existing outgassing-test data as well as contamination analyses relating to the instrument being tested.

O'Donnell, T.↗

Optical device enables small detector to see large field of view

Optical device images the sun on a mask that transmits it or prevents its transmission to a photodetector behind the mask depending on image position on the mask. The device uses a pinhole as the image former to provide a large field of view and diffraction-limited resolution.

Arndt, J. H.↗

Faint Object Spectrograph (FOS) calibration

The Faint Object Spectrograph (FOS) designed for use with The Space Telescope (ST), is currently preparing for instrument assembly, integration, alignment, and calibration. Nearly all optical and detector elements have been completed and calibrated, and selection of flight detectors and all but a few optical elements has been made. Calibration results for the flight detectors and optics are presented, and plans for forthcoming system calibration are briefly described.

Harms, R. J.↗

Cubespark: A New Satellite-Based 3d Lightning Observing Concept

Legacy and current space-based optical lightning detectors are insensitive to small and dim pulses that make up much of the lightning activity produced by severe storms. Moreover, lightning flashes produced at low altitudes within optically thick clouds are severely under-detected by current optical detectors. Lastly, there is currently no capability to characterize the 3D structure of lightning both day and night at the global scale, yet this information is critical for identifying lightning produced in updraft regions, including lightning occurring in overshooting tops, which is a distinctive signature of severe weather. Global 3D lightning information is also critical for understanding the vertical distribution of NOx production and identifying anomalously electrified storms. Furthermore, the vertical distribution of lightning has implications for how microphysical (e.g., ice-based) and thermodynamical (e.g., latent heat release) processes vary regionally, as well as seasonally – e.g., winter lightning typically occurs at lower altitudes than summer lightning and is often associated with tall, man-made structures. Finally, global-scale 3D lightning observations would directly provide flash type (i.e., CG or IC) information that is very useful in all of the studies mentioned in this paragraph and is fundamental in identifying/documenting deleterious CG-caused impacts (e.g., wildfires, power-outages, crop and property damage, and associated insurance claims). A new, satellite mission concept called CubeSpark is being designed to address these shortcomings and fill this measurement gap by providing novel 3D observations of total lightning activity. CubeSpark will utilize a constellation of low-Earth orbiting small satellites that make radio frequency (RF) and bi-spectral optical measurements of lightning. Two options for combining these measurements to retrieve the 3D location of lightning are considered with corresponding measurement simulators built to understand the level of detail and viability of each approach. Although the level of detail varies for each combined measurement approach, results indicate that a 3D location accuracy of < 1-2 km in each dimension is feasible across 300-500 km wide swaths, which suggests that CubeSpark can resolve the charge structure of thunderclouds from the tropics to the mid- and high-latitudes.

lightning↗

Few-Mode Fiber Coupled Superconducting Nanowire Single-Photon Detectors for Photon Efficient Optical Communications

The NASA Glenn Research Center's development of a high-photon efficiency real-time optical communications ground receiver has added superconducting nanowire single-photon detectors (SNSPDs) coupled with few-mode fibers (FMF). High data rate space-to-ground optical communication links require enhanced ground receiver sensitivity to reduce spacecraft transmitter constraints, and therefore require highly efficient coupling from fiber to detector. In the presence of atmospheric turbulence the received optical wave front can be severely distorted introducing higher-order spatial mode components to the received signal. To reduce mode filtering and mismatch loss and the resulting degradations to detector coupling efficiency, we explore the use of few-mode fiber coupling to commercial single-pixel SNSPDs. Graded index 20-µm few-mode fibers allow the commercial single pixel SNSPD's active area to couple with equal efficiency as single mode fibers. Here we determine detector characteristics such as count rate, detection efficiency, dark counts, and jitter, as well as detection efficiencies for higher-order fiber spatial modes. Additionally, we assess the laboratory performance of the detectors in an optical system which emulates future deep space optical communications links.

Vyhnalek, Brian E.↗

Evaluation of Carbon Dioxide Sensors for the Constellation Space Suit Life Support System for Surface Exploration

This paper presents the findings of the trade study to evaluate carbon dioxide (CO2) sensing technologies for the Constellation (Cx) space suit life support system for surface exploration. The trade study found that nondispersive infrared absorption (NDIR) is the most appropriate high Technology Readiness Level (TRL) technology for the CO2 sensor for the Cx space suit. The maturity of the technology is high, as it is the basis for the CO2 sensor in the Extravehicular Mobility Unit (EMU). The study further determined that while there is a range of commercial sensors available, the Cx CO2 sensor should be a new design. Specifically, there are light sources (e.g., infrared light emitting diodes) and detectors (e.g., cooled detectors) that are not in typical commercial sensors due to cost. These advanced technology components offer significant advantages in performance (weight, volume, power, accuracy) to be implemented in the new sensor. The exact sensor design (light source, transmitting optics, path length, receiving optics and detector) will be specific for the Cx space suit and will be determined by the performance requirements of the Cx space suit. The paper further identifies specifications for some of the critical performance parameters as well as discussing the engineering aspects of implementing the sensor into the Portable Life Support System (PLSS). The paper then presents testing results from three CO2 sensors with respect to issues important to Extravehicular Activity (EVA) applications; stability, humidity dependence and low pressure compatibility. The three sensors include two NDIR sensors, one commercial and one custom-developed by NASA (for a different purpose), and one commercial electrochemical sensor. The results show that both NDIR sensors have excellent stability, no dependence on ambient humidity (when the ambient temperature is above the dew point) and operate in low pressure conditions and after being exposed to a full vacuum. The commercial electrochemical sensor was not suitable for the Cx space suit for surface exploration. Finally, the paper identifies a number of techniques currently under development that offer significant advantages for EVA applications. These include miniaturized, room temperature, solid electrolyte systems and advanced optical detectors.

Dietrich, Daniel L.↗

(Cd,Mg)Te crystals for picosecond-response optical-to-x-ray radiation detectors

We demonstrate a photodetector sensitive to both optical and x-ray picosecond pulses based on our in-house grown cadmium magnesium telluride (Cd,Mg)Te single crystal. Specifically, we developed In-doped Cd0.96Mg0.04Te material and discuss its femtosecond optical photoresponse, as well as the detector performance, such as <100-pA dark current and up to 0.22-mA/W responsivity for 780-nm wavelength optical radiation. The detector exposed to Ti fluorescence (K alpha) x-ray pulses at 4.5 keV, generated by a free-electron laser beam with the central energy of 9.8 keV and <100 fs pulse width, exhibited readout-electronics-limited 200-ps full-width-at-half-maximum photoresponse, demonstrating that it is suitable for coarse timing in free-electron laser x-ray/optical femtosecond pump–probe spectroscopy applications.

Instruments & Instrumentation↗