Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical interference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

On Hilbert-Huang Transform Based Synthesis of a Signal Contaminated by Radio Frequency Interference or Fringes

Norden E. Huang et al. had proposed and published the Hilbert-Huang Transform (HHT) concept correspondently in 1996, 1998. The HHT is a novel method for adaptive spectral analysis of non-linear and non-stationary signals. The HHT comprises two components: - the Huang Empirical Mode Decomposition (EMD), resulting in an adaptive data-derived basis of Intrinsic Mode functions (IMFs), and the Hilbert Spectral Analysis (HSA1) based on the Hilbert Transform for 1-dimension (1D) applied to the EMD IMF's outcome. Although paper describes the HHT concept in great depth, it does not contain all needed methodology to implement the HHT computer code. In 2004, Semion Kizhner and Karin Blank implemented the reference digital HHT real-time data processing system for 1D (HHT-DPS Version 1.4). The case for 2-Dimension (2D) (HHT2) proved to be difficult due to the computational complexity of EMD for 2D (EMD2) and absence of a suitable Hilbert Transform for 2D spectral analysis (HSA2). The real-time EMD2 and HSA2 comprise the real-time HHT2. Kizhner completed the real-time EMD2 and the HSA2 reference digital implementations respectively in 2013 & 2014. Still, the HHT2 outcome synthesis remains an active research area. This paper presents the initial concepts and preliminary results of HHT2-based synthesis and its application to processing of signals contaminated by Radio-Frequency Interference (RFI), as well as optical systems' fringe detection and mitigation at design stage. The Soil Moisture Active Passive (SMAP mission (SMAP) carries a radiometer instrument that measures Earth soil moisture at L1 frequency (1.4 GHz polarimetric - H, V, 3rd and 4th Stokes parameters). There is abundant RFI at L1 and because soil moisture is a strategic parameter, it is important to be able to recover the RFI-contaminated measurement samples (15% of telemetry). State-of-the-art only allows RFI detection and removes RFI-contaminated measurements. The HHT-based analysis and synthesis facilitates recovery of measurements contaminated by all kinds of RFI, including jamming [7-8]. The fringes are inherent in optical systems and multi-layer complex contour expensive coatings are employed to remove the unwanted fringes. HHT2-based analysis allows test image decomposition to analyze and detect fringes, and HHT2-based synthesis of useful image.

Spacecraft Electronics Equipment↗

Surface Temperature Measurements from a Stator Vane Doublet in a Turbine Engine Afterburner Flame Using a YAG:Tm Thermographic Phosphor

Luminescence-based surface temperature measurements were obtained from a YAG:Tm-coated stator vane doublet exposed to the afterburner flame of a J85 test engine at University of Tennessee Space Institute (UTSI). The objective of the testing was to demonstrate that reliable surface temperatures based on luminescence decay of a thermographic phosphor producing short-wavelength emission could be obtained from the surface of an actual engine component in a high gas velocity, highly radiative afterburner flame environment. YAG:Tm was selected as the thermographic phosphor for its blue emission at 456 nm (1D23F4 transition) and UV emission at 365 nm (1D23H6 transition) because background thermal radiation is lower at these wavelengths, which are shorter than those of many previously used thermographic phosphors. Luminescence decay measurements were acquired using a probe designed to operate in the afterburner flame environment. The probe was mounted on the sidewall of a high-pressure turbine vane doublet from a Honeywell TECH7000 turbine engine coated with a standard electron-beam physical vapor deposited (EB-PVD) 200-m-thick TBC composed of yttria-stabilized zirconia (YSZ) onto which a 25-m-thick YAG:Tm thermographic phosphor layer was deposited by solution precursor plasma spray (SPPS). Spot temperature measurements were obtained by measuring luminescence decay times at different afterburner power settings and then converting decay time to temperature via calibration curves. Temperature measurements using the decays of the 456 and 365 nm emissions are compared. While successful afterburner environment measurements were obtained to about 1300C with the 456 nm emission, successful temperature measurements using the 365 nm emission were limited to about 1100C due to interference by autofluorescence of probe optics at short decay times.

thermographic phosphor↗

Applicability of Spectral Decomposition by Varimax-Rotated, Principal Component Analysis to the Surface Biology and Geology (SBG) VNIR Mission Concept

Cyanobacterial and Harmful Algal Blooms (CyanoHABs) are a growing concern in coastal and inland waters. But, spectral interference from multiple constituents in optically complex waters can hamper application of remote sensing using traditional image processing methods. The Kent State University (KSU) spectral decomposition method can be applied to multispectral and hyperspectral remote sensing images (e.g. HICO and the NASA Glenn HSI2) to partition and identify signals related to cyanobacteria, algae, pigment degradation products and suspended sediment in each pixel. Fundamental to the use of remote sensing data is the ability to extract independent signals from correlated hyperspectral VNIR data cubes. The Kent State University varimax-rotated, principal component analysis method (VPCA) is important to integrate into the SBG VNIR mission concept because it provides greater specificity, a software-based SNR boost relative to hardware performance, and can assist with Cal/Val, Modeling and Applications. We present examples of the hyperspectral application of the KSU VPCA method with relevance to SBG. The information extracted by VPCA can be validated spectrally or spatially with laboratory and/or in situ sensors, which capture spatial or time series of information at discrete points within remote sensing images. Comparisons show hyperspectral sensors extract more components than multispectral ones, but more independent information can be extracted from multispectral sensors by VPCA than traditional band ratio approaches. The spectral decomposition method is capable of enhancing the signal to noise ratio (SNR) of the NASA Glenn, second-generation hyperspectral imager by a factor of 7x to 20x, with a spectral reproducibility of ±3%. The spectral decomposition method, when compared against existing remote sensing monitoring methods exhibits both greater specificity and a lower detection limit. The method has been validated with multispectral images in Lake Erie to quantify the Microcystis CyanoHAB and from the Indian River Lagoon, Florida to quantify the Brown Tide resulting from A. lagunesnsis. Field operations in the Western Basin of Lake Erie were conducted using a bbe Fluoroprobe to collect vertical profiles and horizontal tows along a transect from the Toledo to the Detroit Lighthouse during coincident satellite overpasses. Extraction of pixel values from the MODIS Aqua sensor yields agreement between in situ field and lab-based measures of cyanobacterial, cryptophyte, diatoms and green algae, suspended sediment and pigment degradation products with R2>0.8.

hyperspectral↗

Paths of Partial Coherence: Jim Wyant’s Influence on my Profession Career

Writing a tribute paper is fraught with peril. While it is supposed to be about the other’s impact upon your life, in really it cannot help but be all about the author. Back in 2012, after my initial reluctance, the paper I wrote for the Bill Wolfe tribute[1]was so cathartic, that I had to write one for Jim Wyant–to add a chapter to my story, to explain how a path of successes and failures have lead me to the present, and in the process to exorcise more ghosts from my subconscious. While our relationship is complicated, it has always been respectful. In many regards, Jim Wyant may be one of the most important people helping me reach my potential. I am NOT ‘A’ Wyant Student. I am ‘a’ Wyant student. I took three classes from Jim: Interference and Diffraction, Holography and Optical Testing. As a result of those classes, I found something that I loved, something at which I was good, something that became apart of me–I found my technical bliss. And beyond the classroom, my professional career has been inescapably connected with Jim Wyant.

history↗

Nickel Accounting for the Psyche Spacecraft

(16) Psyche is a metallic asteroid located in the asteroid belt between Mars and Jupiter. The composition of Psyche is unknown, but the scientific community believes it is composed primarily of iron, nickel, and silicates. The Psyche mission will be the first space mission to study this asteroid in close proximity, and as such, determining the elemental composition of the asteroid is one of the primary objectives of this mission. The spacecraft measures this elemental composition using the Gamma Ray Spectrometer (GRS), which detects cosmic-ray induced gamma rays from Psyche’s surface. In addition to gamma rays from Psyche, the GRS will also detect background gamma rays from spacecraft material nearby the GRS. Because Ni is such a key element for achieving the mission science objectives, a special effort has been made to minimize background gamma rays from Ni, thus maximizing sensitivity to the Ni gamma rays from Psyche. The Psyche mission approached this potential Ni background issue with two methods, locating the GRS away from the spacecraft/source of Ni and setting a threshold requirement against the total Ni mass of the spacecraft. Verifying that the total amount of Ni on the spacecraft is within this threshold is thus a key part of ensuring the GRS can meet its science objectives. Ni alloys are commonly used on spacecraft, but the mass and location of elemental Ni is not typically accounted for. Ni can be found in many materials all over the spacecraft – in fasteners, optical assemblies, magnetic shields, electromagnetic interference (EMI) tape, under gold plating, in connectors, and so on. The task proved further challenging because of the distributed nature of the build of this spacecraft and the use of vendors external to JPL. While the analysis was atypical and source information difficult to cull, the approach described in this paper used tools and data available to the project in some form to achieve this goal. For Psyche, current analysis shows there is margin in meeting the Ni mass requirement. This paper explains the systematic approach used to accurately and precisely record Ni content on the Psyche spacecraft. While this approach was defined for Ni on the Psyche mission, it can be used for any future project with the need to accurately estimate the total mass of a single element or material on a spacecraft.

Cullinan, Joe↗

Nickel Accounting for the Psyche Spacecraft

(16) Psyche is a metallic asteroid located in the asteroid belt between Mars and Jupiter. The composition of Psyche is unknown, but the scientific community believes it is composed primarily of iron, nickel, and silicates. The Psyche mission will be the first space mission to study this asteroid in close proximity, and as such, determining the elemental composition of the asteroid is one of the primary objectives of this mission. The spacecraft measures this elemental composition using the Gamma Ray Spectrometer (GRS), which detects cosmic-ray induced gamma rays from Psyche’s surface. In addition to gamma rays from Psyche, the GRS will also detect background gamma rays from spacecraft material nearby the GRS. Because Ni is such a key element for achieving the mission science objectives, a special effort has been made to minimize background gamma rays from Ni, thus maximizing sensitivity to the Ni gamma rays from Psyche. The Psyche mission approached this potential Ni background issue with two methods, locating the GRS away from the spacecraft/source of Ni and setting a threshold requirement against the total Ni mass of the spacecraft. Verifying that the total amount of Ni on the spacecraft is within this threshold is thus a key part of ensuring the GRS can meet its science objectives. Ni alloys are commonly used on spacecraft, but the mass and location of elemental Ni is not typically accounted for. Ni can be found in many materials all over the spacecraft – in fasteners, optical assemblies, magnetic shields, electromagnetic interference (EMI) tape, under gold plating, in connectors, and so on. The task proved further challenging because of the distributed nature of the build of this spacecraft and the use of vendors external to JPL. While the analysis was atypical and source information difficult to cull, the approach described in this paper used tools and data available to the project in some form to achieve this goal. For Psyche, current analysis shows there is margin in meeting the Ni mass requirement. This paper explains the systematic approach used to accurately and precisely record Ni content on the Psyche spacecraft. While this approach was defined for Ni on the Psyche mission, it can be used for any future project with the need to accurately estimate the total mass of a single element or material on a spacecraft.

Cullinan, Joe↗

In-line, High-Throughput Quality Monitoring for Fuel Cell and Electrolyzer Components Based on Transmission and Reflection Imaging

During the manufacturing of fuel cell and electrolyzer membranes and membrane electrode assemblies (MEAs), real-time, in-line, high-throughput optical-based quality monitoring methods are essential for detecting defects and monitoring thickness variations, thus improving the performance and increasing the durability of fuel cell and electrolyzer in the hydrogen industry. For the MEAs with very opaque coatings, optical transmission-based imaging has been developed and applied in the Roll-to-Roll system using a flashlight and a high-sensitivity CCD camera. We observed high signal-to-noise ratio images while the Roll-to-Roll system ran at 5 ft/min. The entire sample image could quickly be recovered from the discrete frames using customized Python codes for automatic frame cropping and stitching. We detected significant non-uniformities in our experimental MEAs specimen. For fuel cell and low-temperature electrolysis (LTE) transparent membranes, we used optical reflectance hyperspectral imaging with interference fringe-based thickness mapping. We set up a hyperspectral camera to measure various rolls of commercial membranes. The measurement results are analyzed to find the thickness distribution of each roll and to check for defects. Transmission and reflection imaging-based quality monitoring techniques demonstrated in this project can be widely used in the mass production environment to improve the production yield and performance of hydrogen devices.

DIRECT ENERGY CONVERSION,ENGINEERING↗

Brewster-Plate Spoiler for Laser Spectrometer

Oscillating Brewster plate reduces effects of unwanted interference fringes on absorption-spectroscopic measurements obtained with tuned diode lasers. Plate modulates optical-path length past several resonance peaks causing interference fringes to pass by rapidly and become blurred. Thus, fringe effects averaged out over time. Technique used at other wavelengths from ultraviolet to infrared and in spectrometers with short or long optical paths, including those with retroreflectors or multipass cells.

Webster, C. R.↗

Peripheral Nerve Magnetoneurography With Optically Pumped Magnetometers

Electrodiagnosis is routinely integrated into clinical neurophysiology practice for peripheral nerve disease diagnoses, such as neuropathy, demyelinating disorders, nerve entrapment/impingement, plexopathy, or radiculopathy. Measured with conventional surface electrodes, the propagation of peripheral nerve action potentials along a nerve is the result of ionic current flow which, according to Ampere’s Law, generates a small magnetic field that is also detected as an “action current” by magnetometers, such as superconducting quantum interference device (SQUID) Magnetoencephalography (MEG) systems. Optically pumped magnetometers (OPMs) are an emerging class of quantum magnetic sensors with a demonstrated sensitivity at the 1 fT/√Hz level, capable of cortical action current detection. But OPMs were ostensibly constrained to low bandwidth therefore precluding their use in peripheral nerve electrodiagnosis. With careful OPM bandwidth characterization, we hypothesized OPMs may also detect compound action current signatures consistent with both Sensory Nerve Action Potential (SNAP) and the Hoffmann Reflex (H-Reflex). In as much, our work confirms OPMs enabled with expanded bandwidth can detect the magnetic signature of both the SNAP and H-Reflex. Taken together, OPMs now show potential as an emerging electrodiagnostic tool.

60 APPLIED LIFE SCIENCES↗

Four Channel Time Multiplexed Photonic Doppler Velocimetry using an Optical Switch

Photonic Doppler Velocimetry (PDV) is a diagnostic commonly used in shock physics and dynamic compression experiments to reliably get velocity information from experiments. In PDV systems, a common method of reducing experimental cost is to use time and frequency multiplexing to increase the number of PDV probes. With time multiplexing, interference between probes is a frequent problem. In this report, we look at using a high-speed optical switch to reduce this interference, including measuring the amount of interference generated to determine if it has the potential to affect experiments and integrating a time multiplexing system into an experiment. We find that, when applied to PDV systems, there is approximately (-23.4 ± 0.9) dB of interference measured in the short time Fourier transform between switch inputs. When an optical switch based time multiplexing system was integrated into a dynamic compression experiment, the system was able to successfully combine the signals from four different PDV probes onto a single optical cable without unacceptable levels of interference in the spectrogram. An optical switch based time multiplexing system appears to be a promising method for reducing the cost of fielding larger numbers of PDV probes in an experiment.

47 OTHER INSTRUMENTATION↗

Silicon-Etalon Fiber-Optic Temperature Sensor

Developmental temperature sensor consists of silicon Fabry-Perot etalon attached to end of optical fiber. Features immunity to electrical interference, small size, light weight, safety, and chemical inertness. Output encoded in ration of intensities at two different wavelengths, rather than in overall intensity, with result that temperature readings not degraded much by changes in transmittance of fiber-optic link.

Beheim, Glenn↗

Fiber optic multiplex optical transmission system

A multiplex optical transmission system which minimizes external interference while simultaneously receiving and transmitting video, digital data, and audio signals is described. Signals are received into subgroup mixers for blocking into respective frequency ranges. The outputs of these mixers are in turn fed to a master mixer which produces a composite electrical signal. An optical transmitter connected to the master mixer converts the composite signal into an optical signal and transmits it over a fiber optic cable to an optical receiver which receives the signal and converts it back to a composite electrical signal. A de-multiplexer is coupled to the output of the receiver for separating the composite signal back into composite video, digital data, and audio signals. A programmable optic patch board is interposed in the fiber optic cables for selectively connecting the optical signals to various receivers and transmitters.

Bell, C. H.↗

Hemispherical-field-of-view, nonimaging narrow-band spectral filter

Two compound parabolic concentrators are used to create a 180-deg-field-of-view spectral filter. The collection optics are reflective and are designed to collimate the light through a multilayer interference filter and then to refocus it onto an optical detector. Assuming unit reflectance and no loss through the optical filter, this device operates at the thermodynamic collection limit.

Miles, R. B.↗

Fiberoptics technology and its application to propulsion control systems

Electro-optical systems have many advantages over conventional electrical systems. Among these are optics' insensitivity to electro-magnetic interference, good electrical isolation and the ability to make measurements in highly explosive areas without risk. These advantages promise to help improve the reliability of future aircraft engine control systems which will be entirely electronic digital. To improve the reliability of these systems, especially against lightning strikes, passive, optical, sensors and fiberoptic transmission lines are being considered for use in future engine systems. Also under consideration are actuators which receive their command signals over fiber optic cables. This paper reviews concepts used for optical instrumentation and actuation systems and discusses work being done by NASA Lewis Research Center in this area.

Baumbick, R. J.↗

Towards a new generation long trace profiler LTP-2020: optical design of pencil beam interferometry sensor

Improvements in the quality of synchrotron beamline x-ray optics required for next-generation light sources (e.g. the ALS Upgrade project) drive the need to improve the performance of the metrology instrumentation used to measure these components. The Long Trace Profiler (LTP) that is in use at many synchrotron metrology laboratories around the world has some known issues that affect the accuracy of its measurements. The main error source is optical path difference (OPD) phase error introduced into the probe beam by inhomogeneities in the glass components used in the optical head. We have developed a new optical head design, LTP-2020, that replaces the cube polarizing beamsplitter (PBS) with a thin wedge plate polarizing beamsplitter (WPBS) and replaces the cemented doublet lens with an aspheric singlet. Both of these components significantly reduce the glass volume traversed by the laser probe beam. Careful attention to ghost ray interference produced by back reflection from optical surfaces is necessary to minimize distortion in the primary image that translates into systematic error in the slope angle measurement. We make extensive use of a commercial raytracing program to model the back reflections and adjust component parameters as necessary to minimize distortion. Deliberate misalignment of components is necessary to make the system perform correctly. Stringent requirements are placed on the 45◦ incidence coatings on the WPBS and on the normal incidence coatings on the lens and camera window elements. We encourage our colleagues who wish to upgrade their current LTP systems to join us in the procurement of these custom optical components.

Takacs, Peter Z.↗

Fast optical transport of ultracold molecules over long distances

Abstract Optically trapped laser-cooled polar molecules hold promise for new science and technology in quantum information and quantum simulation. Large numerical aperture optical access and long trap lifetimes are needed for many studies, but these requirements are challenging to achieve in a magneto-optical trap (MOT) vacuum chamber that is connected to a cryogenic buffer gas beam source, as is the case for all molecule laser cooling experiments so far. Long distance transport of molecules greatly eases fulfilling these requirements as molecules are placed into a region separate from the MOT chamber. We realize a fast transport method for ultracold molecules based on an electronically focus-tunable lens combined with an optical lattice. The high transport speed is achieved by the 1D red-detuned optical lattice, which is generated by interference of a focus-tunable laser beam and a focus-fixed laser beam. Efficiency of 48(8)% is realized in the transport of ultracold calcium monofluoride (CaF) molecules over 46 cm distance in 50 ms, with a moderate heating from 32(2) μ K to 53(4) μ K. Positional stability of the molecular cloud allows for stable loading of an optical tweezer array with single molecules.

74 ATOMIC AND MOLECULAR PHYSICS↗