Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance loss”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Side-by-Side Comparison of Subhourly Clipping Models

Over the past several years there have been numerous attempts at quantifying the inherent power clipping of inverters due to subhourly irradiance variability that is not captured in hourly PV performance models. Different models have been proposed to correct for these clipping losses in PV performance estimates, including matrix lookup models, distribution modeling of the PV power performance within a given hour, and machine learning methods. To date, there have been few comprehensive quantitative comparisons of these inverter clipping correction modeling approaches to evaluate the effectiveness of these approaches in predicting the actual behavior of PV system inverter clipping. In this study, we perform such a comparison, evaluating the Allen and Walker correction loss modeling approaches recently implemented in the System Advisor Model (SAM) against clipping losses modeled with 1-minute climate data. These comparisons were performed across a variety of climate locations and inverter loading ratios to thoroughly analyze the effectiveness of these modeling approaches relative to each other. Results from this analysis reveal that both clipping correction approaches improve annual energy accuracy to within 2% of 1-minute modeled energy yield. The two models predict annual clipping loss more accurately than simple hourly power limit clipping, with the Allen method typically being slightly more accurate at typical ILR values and the Walker method often being slightly more accurate at high ILR values The models can improve accuracy over the status quo clipping approach up to 3 percentage points in systems with ILR of 2.0, showing the importance of this modeling factor in energy yield estimates.

accuracy↗

Side-by-Side Comparison of Subhourly Clipping Models: Preprint

Over the past several years there have been numerous attempts at quantifying the inherent power clipping of inverters due to inter-hourly irradiance variability that is not captured in hourly PV performance models. Different models have been proposed to correct for these clipping losses in PV performance estimates, including matrix lookup models, distribution modeling of the PV power performance within a given hour, and machine learning methods. To date, there have been few comprehensive quantitative comparisons of these inverter clipping correction modeling approaches to evaluate the effectiveness of said approaches in predicting the actual behavior of PV system inverter clipping. In this study, we perform such a comparison, evaluating two different clipping correction loss modeling approaches recently implemented in the System Advisor Model (SAM) against clipping losses modeled with 1-minute climate data. These comparisons will be performed across a variety of climate locations and inverter loading ratios to thoroughly analyze the effectiveness of these modeling approaches relative to each other. Results from this analysis reveal that both clipping correction approaches improve annual energy accuracy to within 2% of 1-minute modeled energy yield. The models can improve accuracy up to 3% in systems with ILR of 2.0, showing the importance of this modeling factor in energy yield estimates.

clipping↗

Exploratory analysis and performance prediction of big data transfer in High-performance Networks

Big data transfer in large-scale scientific and business applications is increasingly carried out over connections with guaranteed bandwidth provisioned in High-performance Networks (HPNs) via advance bandwidth reservation. Provisioning agents need to carefully schedule data transfer requests, compute network paths, and allocate appropriate bandwidths. Such reserved bandwidths, if not fully utilized, could be simply wasted due to the exclusive access during the approved time window, and cause extra overhead and complexity for resource management. This calls for accurate performance prediction to reserve bandwidths that match actual needs and avoid over-provisioning. We employ machine learning algorithms to predict big data transfer performance based on extensive performance measurements collected in the past several years from data transfer tests using different protocols and toolkits between various end sites on several real-life physical or emulated testbeds. We first analyze the performance patterns in response to a comprehensive list of parameters in end-host systems, network connections, and data transfer applications, which motivate the use of machine learning and also help us identify the effects of latent factors. We then propose threshold- and clustering-based methods to eliminate negative effects of latent factors in data preprocessing and build a robust performance predictor based on customized domain-oriented loss functions. The performance of the proposed methods is verified by extensive experiments using SVR and RFR as well as theoretical analysis of the general performance bound.

97 MATHEMATICS AND COMPUTING↗

High-Temperature Linear Receiver Enabled by Multicomponent Aerogels

Concentrating solar thermal (CST) technology has significant potential mainly due to its dispatchability and low cost of storage. However, to compete with other sources, including utility-scale solar PV, its final cost (cents/kWh) still needs to be lowered. Cost reduction can be achieved by improving the system level efficiency of the CST plants through the deployment of advanced power cycles, which operate at high temperatures of ~700°C. However, optical, and thermal losses pose a major challenge to the efficiency of such CST systems. The overall aim of this project is to investigate and de-risk a linear solar receiver concept called an Aerogel Insulated Receiver (AIR) that generates high temperatures (up to 700°C) at a low solar concentration ratio (<100) and with a high collection efficiency (optical × receiver). Our prior work has demonstrated the thermal stability1 and optical and heat-insulating properties2,3 of transparent aerogel insulation at a one-inch scale. The focus of this work is on (1) co-optimization of the geometry of the aerogel tile and receiver enclosure to fit a standard parabolic collector (PTC), (2) scale-up of aerogels into 4-inch tiles while preserving key properties, (3) experimental measurement of receiver heat loss (W/m) in a >70-cm test stand and validation of anticipated receiver performance at high temperatures. Regarding (1), appropriate optical and thermal models for a parabolic trough receiver (PTR) are developed and validated. The geometry of the aerogels and the receiver enclosure are co-optimized to maximize the collection efficiency. The model predicts a 54% collection efficiency at 700°C for an AIR design based on flat aerogels. By combining the collection efficiency with the power block efficiency of supercritical CO 2 cycles, we predict >10% improvements in peak plant efficiency relative to existing line-focusing CST systems. The application of curved plasmonic aerogels is predicted to further increase the collection efficiency to 64%. Regarding (2), we demonstrate the successful development of 6-inch-long refractory aerogel tiles with optical, thermal, and stability characteristics consistent with our prior work. This scale-up requires a transition to a larger ALD station and modifying the ALD process variables such as exposure time and the number of precursor doses. Regarding (3), we design and develop an AIR test stand measuring 3 feet in length. Heat loss performance analysis is carried out using the test stand. The results indicate that aerogel insulation can significantly reduce receiver thermal losses at the high operating temperatures required for next-generation PTRs. The experimental results agree with the heat loss performance predicted by our receiver model. Lastly, we conducted preliminary failure mode and effects (FMEA) and techno-economic (TEA) analyses to identify failure mitigation strategies and commercial opportunities, respectively. Overall, this project identifies key opportunities and challenges in deploying aerogel insulating receivers in next-generation line-focusing CST technologies.

14 SOLAR ENERGY↗

An Investigation on the Pollen-Induced Soiling Losses in Utility-Scale PV Plants

Here in this study, the impact of pollen as a PV soiling agent is investigated. The performance data of five utility-scale PV plants in North Carolina, USA, was collected and analyzed using two soiling extraction methods. Satellite and environmental data, including pollen counts, cropland, and vegetation, was also collected and analyzed to identify impacts to soiling losses. During the spring peak pollen season, performance losses of >15% were observed at all five sites. Partial performance recoveries following the pollen season were slow, with lack of correlation with rainfall. This means that the statistical soiling estimation methods that assume abrupt performance recovery from rain are not appropriate for pollen-impacted solar sites. When manual cleanings were performed on site the performance recovery ranged from 5% to 11% indicating persistent soiling impacts are present in this region. The results of this work provide new insights into the phenomenon of pollen deposition on PV systems, demonstrating that 1) soiling can also affect systems located in rainy locations and 2) that its effects cannot be determined using the current estimation methodologies.

14 SOLAR ENERGY↗

Enhancing Header Shape Through Computational Fluid Dynamics for Improved Performance

Shape optimization in power plant design is crucial for maximizing efficiency and minimizing energy losses It impacts performance, cost effectiveness, and environmental sustainability Our project focuses on optimizing header pipe geometry using a method that considers temperature, flow, and pressure distributions, along with structural analysis This approach ensures structural integrity while minimizing material costs

20 FOSSIL-FUELED POWER PLANTS↗

Quantifying Trapped Magnetic Vortex Losses in Niobium Resonators at mK Temperatures

Trapped magnetic vortices in niobium introduce microwave losses that degrade the performance of superconducting resonators. While such losses have been extensively studied above 1 K, we report here their direct quantification in the millikelvin and low-photon regime relevant to quantum devices. Using a high-quality factor 3D niobium cavity cooled through its superconducting transition in controlled magnetic fields, we isolate vortex-induced losses and find the resistive component of the sensitivity to trapped flux S to be approximately 2 nOhm/mG at 10 mK and 6 GHz. The decay rate is initially dominated by two-level system (TLS) losses from the native niobium pentoxide, with vortex-induced degradation of T1 occurring above Btrap~50 mG. In the absence of the oxide, even 10 mG of trapped flux limits performance, Q0 ~ 1010, or T1 ~350 ms, underscoring the need for stringent magnetic shielding. The resistive sensitivity, S, decreases with temperature and remains largely field-independent, whereas the reactive component, S , exhibits a maximum near 0.8 K. These behaviors are well modeled within the Coffey Clem framework in the zero-creep limit, under the assumption that vortex pinning is enhanced by thermally activated processes. Our results suggest that niobium-based transmon qubits can tolerate vortex-induced dissipation at trapped field levels up to several hundred mG, but achieving long coherence times still requires careful magnetic shielding to suppress lower-field losses from other mechanisms

Bafia, Daniel P. [Fermilab]↗

Quantifying trapped magnetic vortex losses in niobium resonators at mK temperatures

Trapped magnetic vortices in niobium introduce microwave losses that degrade the performance of superconducting resonators. While such losses have been extensively studied above 1 K, we report here their direct quantification in the millikelvin and low-photon regime relevant to quantum devices. Using a high-quality factor 3D niobium cavity cooled through its superconducting transition in controlled magnetic fields, we isolate vortex-induced losses and find the resistive component of the sensitivity to trapped flux S to be approximately 2 n Ω/mG at 10 mK and 6 GHz. The decay rate is initially dominated by two-level system (TLS) losses from the native niobium pentoxide, with vortex-induced degradation of T 1 occurring above B trap ∼ 50 mG. In the absence of the oxide, even 10 mG of trapped flux limits performance, Q 0 ∼ 10 10 , or T 1 ∼ 350 ms, underscoring the need for stringent magnetic shielding. The resistive sensitivity, S, decreases with temperature and remains largely field-independent, whereas the reactive component, S′, exhibits a maximum near 0.8 K. These behaviors are well modeled within the Coffey–Clem framework in the zero-creep limit, under the assumption that vortex pinning is enhanced by thermally activated processes. Our results suggest that niobium-based transmon qubits can tolerate vortex-induced dissipation at trapped field levels up to several hundred mG, but achieving long coherence times still requires careful magnetic shielding to suppress lower-field losses from other mechanisms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Editors’ Choice—Examining Performance and Durability of Anion Exchange Membrane Fuel Cells with Novel Spirocyclic Anion Exchange Membranes

A series of spirocyclic copolymer membranes with varying ion exchange capacities (IECs) were investigated to probe the impact of polymer properties on in situ fuel cell performance and stability. In-situ electrochemical tests and post-mortem electron microscopy analysis of cross-sectioned membrane electrode assemblies (MEAs) have been combined with voltage loss breakdown analysis to evaluate the performance and degradation of different MEAs, and to probe the catalyst morphology and electrode structure at different stages of operation. Voltage loss breakdown results show that membrane degradation and kinetic losses played only a minor role in observed performance degradation and that performance losses were primarily related to increasing mass transport losses. From microscopy studies, carbon corrosion and Pt nanoparticle growth were identified at both the cathode and anode although more pronounced on the cathode resulting in significant structural changes. The membrane with the lowest IEC (1.3 mmolg −1 ) demonstrated the lowest peak power density ~ 1.16 W cm −2 , however, it showed the most stable performance (constant 0.6 A cm −2 hold) with ~ 5% degradation over 540 h. Isolation of performance losses and microscopic analysis of electrodes for anion exchange membrane fuel cells has not been reported previously, and these results help identify critical performance degradation concerns.

25 ENERGY STORAGE↗

New Approaches to Improved PEM Fuel Cell Catalyst Layers

Polymer-electrolyte membrane (PEM) fuel-cells are one of the most promising energy conversion technologies for renewable clean energy applications. A major challenge preventing the widespread use and commercialization of PEM fuel cells is achieving high performance with low-loadings of platinum group metal (PGM) catalysts. One of the factors driving performance limitations in the cell is the mass transport losses within the cathode catalyst layers (CCL) due to sluggish oxygen-reduction reactions occurring at the platinum-ionomer interface. Any resistance to transport of these ionic and gaseous species within the CCL results in mass-transport limitations and performance losses, especially at high current densities. It is known that mass-transport losses increase with reduced platinum loading, thereby creating a performance-cost tradeoff for fuel cells. A viable solution to reduce the transport resistances in the catalyst layers is to create new ionomers that can provide good ion and oxygen transport needed to accomplish high-performing fuel cell catalysts. Using this approach Tetramer Technologies and LBNL propose improved fuel-cell catalyst ionomers based on Tetramers proprietary polymer chemistry.

30 DIRECT ENERGY CONVERSION↗

Evaluating the effect of membrane-ionomer combinations and supporting electrolytes on the performance of cobalt nanoparticle anodes in anion exchange membrane electrolyzers

In low temperature polymer electrolyte membrane electrolyzers, component choices and membrane electrode assembly (MEA) fabrication have pivotal roles in determining cell performance. Here, cobalt anodes were used in combination with different ionomers, membranes, and supporting electrolytes to delineate their effect on MEA performance in anion exchange membrane (AEM) based electrolyzers. Changes to the ionomer type suppress or enhance catalyst redox and were found to alter the resulting exchange current densities and Tafel slopes. Changes in membrane conductivity account for large differences in performance and overpotential losses among the different MEAs, with higher conductivity minimizing ohmic losses. Within supporting electrolytes, lower concentration results in lower conductivity and lower MEA performance; the performance, however, is higher in potassium hydroxide than bicarbonate. These experiments address the influence of individual components and their integration on cell-level performance, to help develop a pathway to an electrolyte free system while providing a foundation for studying electrode composition and component incorporation into MEAs.

25 ENERGY STORAGE↗

High Velocity, Low‐Voltage Collective In‐Plane Switching in (100) BaTiO 3 Thin Films

Abstract Ferroelectrics are being increasingly called upon for electronic devices in extreme environments. Device performance and energy efficiency is highly correlated to clock frequency, operational voltage, and resistive loss. To increase performance it is common to engineer ferroelectric domain structure with highly‐correlated electrical and elastic coupling that elicit fast and efficient collective switching. Designing domain structures with advantageous properties is difficult because the mechanisms involved in collective switching are poorly understood and difficult to investigate. Collective switching is a hierarchical process where the nano‐ and mesoscale responses control the macroscopic properties. Using chemical solution synthesis, epitaxially nearly‐relaxed (100) BaTiO 3 films are synthesized. Thermal strain induces a strongly‐correlated domain structure with alternating domains of polarization along the [010] and [001] in‐plane axes and 90° domain walls along the [011] or [01] directions. Simultaneous capacitance–voltage measurements and band‐excitation piezoresponse force microscopy revealed strong collective switching behavior. Using a deep convolutional autoencoder, hierarchical switching is automatically tracked and the switching pathway is identified. The collective switching velocities are calculated to be ≈500 cm s −1 at 5 V (7 kV cm −1 ), orders‐of‐magnitude faster than expected. These combinations of properties are promising for high‐speed tunable dielectrics and low‐voltage ferroelectric memories and logic.

36 MATERIALS SCIENCE↗

Carbon Corrosion in Polymer Electrolyte Fuel Cells: A Complex Interplay between Morphological Changes and Electrochemical Performance

Due to the high gravimetric energy density of hydrogen, the focus of implementation of polymer electrolyte fuel cells (PEFCs) has shifted from light duty passenger vehicles to heavy duty vehicles such as buses, trucks, locomotives and marine vessels. A mechanistic understanding of degradation is therefore necessary to improve durability and efficiency. During start-up and shut-down (SUSD) of PEFC systems, the catalyst (Pt nanoparticles embedded on carbon support) undergoes local potentials ~ 1 - 1.5 V caused by a combination of fuel (H 2 ) starvation, mixed fuel region and cell reversal. This leads to a series of degradation phenomenon including reduction in cathode catalyst layer (cCL) thickness and porosity, loss in electrochemical surface area (ECSA), ionomer degradation and loss in electrical contact, therefore resulting in severe performance loss. The convoluted relationship between these individual degradation mechanisms, their chronology and their effects on electrochemical performance are yet unresolved. Here, the complex interplay between morphological changes due to carbon corrosion and its effects on the electrochemical performance were analyzed using a combination of detailed electrochemical characterization, spectroscopy, and electron microscopy techniques.

25 ENERGY STORAGE↗

Chemical Reactor Network Modeling of Ammonia Rich-Quench-Lean Combustion Using a Partially Stirred Reactor Approach

Ammonia is a promising alternative fuel, but its use is challenging due to low flammability and high nitrogen oxide (NOx) emissions. Two-stage rich-quench-lean (RQL) combustion strategies have shown promise in reducing NOx emissions. This approach involves two stages: a rich stage that oxidizes part of the fuel and decomposes ammonia into hydrogen, and a lean stage that burns out the hydrogen and residual ammonia. Researchers used a chemical reactor network model to study the effects of heat loss and mixing on emissions performance. They found that heat loss and reduced mixing rates can lead to increased NOx emissions and N2O formation. The results will inform the development of optimized two-stage RQL combustors for ammonia, with a focus on minimizing NOx emissions and improving overall efficiency.

ammonia combustion↗

Performance Index Assessment for the PV Fleet Performance Data Initiative

We report on 250 PV systems throughout the United States, comprising 157 MWdc of system capacity and more than 10,000 monthly performance index (PI) values. Loss factors were isolated including first-year start-up issues, snowfall, soiling and inverter downtime. Inverter availability was found to contribute significant system energy loss during the first six months of operation, with an average of 8% loss occurring during this period, and 2.3% on average thereafter. Other start-up issues beyond inverter downtime, such as partial string outage, contributed additional underperformance in the first year of operation across the fleet. Winter performance was also found to be below summer performance on average, likely due to snowfall. A relationship was found between monthly snowfall accumulation in centimeters and monthly under-performance, indicating a 6%-40% loss in months with measured snowfall, depending on climate. After correcting for availability, snow and startup loss, over 90% of systems were performing within 10% of monthly expectation based on satellite resource data and PVWatts production estimates.

loss factors↗

Toward More Efficient Organic Solar Cells: A Detailed Study of Loss Pathway and Its Impact on Overall Device Performance in Low‐Offset Organic Solar Cells

Abstract Low‐offset organic solar cell systems have attracted great interest since nonfullerene acceptors came into the picture. While numerous studies have focused on the charge generation process in these low‐offset systems, only a few studies have focused on the details of each loss channel in the charge generation process and their impact on the overall device performance. Here, several nonfullerene acceptors are blended with the same polymer donor to form a series of low‐offset organic solar cell systems where significant variation in device performance is observed. Through detailed analyses of loss pathways, it is found that: i) the donor:acceptor interfaces of PM6:Y6 and PM6:TPT10 are close to the optimum energetic condition, ii) energetics at the donor:acceptor interface are the most important factor to the overall device performance, iii) exciton dissociation yield can be field‐dependent owing to the sufficiently small energetic offset at the donor:acceptor interface, and iv) the change in substituents in the terminal group of Y‐series acceptors in this work mainly affects energetics at the donor:acceptor interface instead of the interface density in the active layer. In general, this work presents a path toward more efficient organic solar cells.

14 SOLAR ENERGY↗

Vortex motion induced losses in tantalum resonators

Tantalum (Ta)-based superconducting circuits have been demonstrated to enable ultrahigh qubit quality factors (𝑄), motivating a careful study of the microscopic origin of the remaining losses that limit their performance. We have recently shown that the losses in Ta-based resonators are dominated by two-level systems at low microwave powers and millikelvin temperatures. We also observe that some devices exhibit loss that is exponentially activated at a lower temperature inconsistent with the superconducting critical temperature (T 𝑐 ) of the constituent film. Specifically, dc resistivity measurements show a T 𝑐 of over 4 K, while microwave measurements of resonators fabricated from these films show losses that increase exponentially with temperature with an activation energy as low as 0.3 K. Here, in this study, we present a comparative study of the structural and thermodynamic properties of Ta-based resonators and identify vortex motion-induced loss as the source of thermally activated microwave loss. Through careful magnetoresistance and x-ray diffraction measurements, we observe that the increased loss occurs for films that are in the clean limit, where the superconducting coherence length (𝜉) is shorter than the mean free path (𝑙). Vortex motion-induced losses are suppressed for films in the dirty limit, which show evidence of structural defects that can pin vortices. We verify this hypothesis by explicitly pinning vortices via patterning, and we find that we can suppress the loss by microfabrication.

36 MATERIALS SCIENCE↗