A Guide to Case Studies of Grid Enhancing Technologies

This document has been developed as a resource for the electric power industry to rapidly understand the scale and history with which certain new technologies have been installed on or otherwise simulated to impact the transmission system. This document is attempting to address the findings of the 2022 U.S. Department of Energy (DOE) Report "Grid Enhancing Technologies: A Case Study on Ratepayer Impact", which identified the need for workforce development and training materials to transition new technologies from a state of “pilots” and “case studies” to “business-as-usual.” The authors go beyond typical survey-style literature reviews in that the key details and notes about each project are identified. Still, as will become evident, there is a need for more work to be done to increase the industry’s public knowledge on important topics related to the implementation of grid enhancing technology on the transmission system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The utility of Bayesian data reconciliation for separations

Data reconciliation methods for separation processes typically rely on classical statistical approaches to generate estimates of true mass flow rates from measurements. Knowledge regarding the uncertainty of these estimates has value in decision making, but is often not acquired. Bayesian approaches intrinsically quantify uncertainty; however, literature for Bayesian data reconciliation of separation processes is scarce. This publication outlines two Bayesian data reconciliation models and provides details for how the models were implemented for the BayesMassBal (V 1.0.0) software package written in R. To demonstrate the advantages of this approach for data reconciliation, the models were first applied to simulated data and then compared to a classical model through a Monte Carlo experiment. In this example, the Bayesian models were found to provide more accurate estimates of the simulated data, while also providing quantitative information on the estimate uncertainty. To demonstrate the use of the technique in a practical problem, the models were also applied to real data collected from a pilot-scale rare earth solvent extraction process. Here, this publication provides a small window into how Bayesian methods can be used for data reconciliation, but findings suggest Bayesian data reconciliation models for separation processes have distinct advantages over classical alternatives.

01 COAL, LIGNITE, AND PEAT↗

Assessment of vertical stability for negative triangularity pilot plants

Abstract Negative triangularity (NT) tokamak configurations may be more susceptible to magneto-hydrodynamic instability, posing challenges for recent reactor designs centered around their favorable properties, such as improved confinement and operation free of edge-localized modes. In this work, we assess the vertical stability of plasmas with NT shaping and develop potential reactor solutions. When coupled with a conformal wall, NT equilibria are confirmed to be less vertically stable than equivalent positive triangularity (PT) configurations. Unlike PT, their vertical stability is degraded at higher poloidal beta. Furthermore, improvements in vertical stability at low aspect ratio do not translate to the NT geometry. NT equilibria are stabilized in PT vacuum vessels due to the increased proximity of the plasma and the wall on the outboard side, but this scenario is found to be undesirable due to reduced vertical gaps which give less spatial margin for control recovery. Instead, we demonstrate that informed positioning of passively conducting plates can lead to improved vertical stability in NT configurations on par with stability metrics expected in PT scenarios. An optimal setup for passive plates in highly elongated NT devices is presented, where plates on the outboard side of the device reduce vertical instability growth rates to 16% of their baseline value. For lower target elongations, integration of passive stabilizers with divertor concepts can lead to significant improvements in vertical stability. Plates on the inboard side of the device are also uniquely enabled in NT geometries, providing opportunity for spatial separation of vertical stability coils and passive stabilizers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Residential Vehicle-to-Home Backup Power Capabilities: Key Findings from a ComEd Beneficial Electrification R&D Pilot

This report summarizes key findings from a collaborative technical study of residential, non-grid-tied vehicle-to-home (V2H) backup power systems in Commonwealth Edison’s (ComEd’s) service territory. The work integrates (1) a feeder-level technoeconomic analysis (TEA) using historical outage-event data and simulated electric-vehicle (EV) driving/charging profiles to estimate potential reliability and customer interruption-cost impacts under V2H and vehicle-to-grid (V2G) adoption scenarios; (2) controlled laboratory performance testing of a representative V2H backup ecosystem to characterize transfer-to-backup behavior, sustained power delivery, efficiency trends, and repeatable reliability limitations; and (3) a cybersecurity assessment aligned with NIST Cybersecurity Framework (CSF) 2.0 and ISO/SAE 21434 to evaluate interface-level risk drivers and identify program-relevant mitigations. Results indicate that V2H can provide measurable resilience value, but outcomes are strongly context dependent on outage patterns and the share of events that are “V2H-applicable.” Typical transfer-to-backup behavior clustered on the order of minutes, but rare long-delay edge cases were observed (including an event approaching 30 minutes) and should be treated as a reliability risk. High-power testing showed that peak-rated output is not necessarily continuously deliverable; stable operation may require operation below nameplate ratings and attention to thermal and installation constraints. The cybersecurity assessment highlights a broad attack surface spanning commissioning, home networks, embedded services, and cloud/OTA pathways, motivating minimum controls for secure onboarding, signed updates, patch cadence, and coordinated vulnerability response for any scaled deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Melt compounding of spray-dried cellulose nanofibrils/polypropylene and their application in 3D printing

Abstract Micro- and nano-scale cellulosic fillers exhibit excellent dispersion and distribution within a thermoplastic matrix during the process of melt compounding or injection molding. In this study, spray-dried cellulose nanofiber (SDCNF) powders were manufactured using a pilot-scale rotating disk atomizer spray dryer. Bleached Kraft pulp (BKP), unbleached Kraft pulp (UKP), and old corrugated cardboard pulp (OCC) fibrillated at a fines level of 90% were used as feedstock materials for spray-drying. BKP-, UKP-, and OCC- SDCNFs were compounded with polypropylene using a twin screw co-rotating extruder. Maleic anhydride grafted polypropylene (MAPP) was used as a coupling agent in the composite formulations. The tensile, flexural, and impact properties of SDCNF-filled PP composites increased at 10 wt% SDCNF loading. The presence of SDCNFs in the PP matrix resulted in faster crystallization and a 12% reduction in the degree of crystallinity of the neat PP. The coefficient of thermal expansion (CTE) of neat PP was reduced by up to 31% attributable to the presence of the SDCNFs. Application of the SDCNF-reinforced PP composites in 3D printing reduced the shrinkage rate of the printed neat PP by 39%, and the printability of the PP was significantly improved with the addition of the SDCNFs.

Materials Science↗

Advanced Moderation Module for High-Temperature Micro-Reactor Applications

Development and deployment of micro-reactors that provide competitive efficiency, prevailing compactness, and inherent safety is an immediate focus of the U.S. nuclear industry. For thermal neutron micro-reactors operating at elevated temperature for optimized efficiency, such as micro molten-salt reactors (MSRs), heat-pipe reactors, and very-high temperature reactors (VHTRs), high-performance moderator based on metal hydride can enhance the neutron economy and therefore achieve reduced weight and enhanced portability. As unclad metal hydride inevitably decomposes at elevated temperature, an enclosure is required for hydride moderator to deliver desired performance at elevated temperatures. Conventional moderator enclosure solutions based on high-temperature alloys introduce extraneous neutron penalty into the micro-reactor, affecting the neutronic benefits provided by the hydride moderator. Additionally, the compatibility between the high-temperature alloy enclosure and the micro-reactor matrix is also a potential issue. In this report, we disclose an Advanced Moderator Module (AMM) concept enabled by an innovative enclosure solution combining the advantages of refractory metals, ceramic matrix composites (CMCs), and advanced coating technology to serve as hydrogen permeation barrier up to very-high temperatures. A schematic description of the AMM structure is illustrated in Figure A1. The AMM contains a moderating material core made of metal hydride with high thermal stability, such as YH 2-x . The hydride core is enclosed by an H 2 barrier layer coated on a ductile refractory metal liner to minimize hydrogen loss during high-temperature operation. A ceramic matrix composite (CMC) cladding is adopted to provide further structural strength, especially during power transients. Between the CMC cladding and metal liner, an extra diffusion barrier coating is inserted to suppress the chemical interaction at elevated temperatures. Hence, based on a series of innovative material solutions, the AMM is capable of containing the metal hydride core at elevated temperature (>900oC) inside coated and lined CMC envelop with negligible hydrogen loss throughout the microreactor lifetime. The benefit of the AMM technology was assessed based on a comprehensive multi-stage reactor-physics analysis. Advanced moderation based on hydride metals (such as YH2-x) enables reaching optimum moderation with higher fuel content than traditional VHTR technology, which is required to design compact micro-reactor cores targeting long-life operation. The AMM enclosure technology provides lower thermal neutron absorption rates than traditional solutions (based on stainless steel or Mo-based alloy such as TZM), which reduces the fissile enrichment requirements by 6-8% on a TRISO-fueled design based on the EMPIRE core. Finally, combining the hydride moderator with neutron transparent enclosure solutions provides significant potential to boost neutronics performance of micro-reactors in terms of increased core lifetime or reduced size and weight by 30-50% on a micro-reactor based on the Holos Quad technology. The progress and plans for on-going development and demonstration efforts are also discussed in this report. The current demonstration of AMM is focused on the hydrogen diffusion barrier demonstration under thermal cycling, while radiation tolerance demonstration is planned. The next step of the demonstration plan will be the assembly of miniature AMM for high-temperature testing, which can be used as a prototype for future pilot scale demonstration.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The scoping, design, and plasma physics optimization of the Eos neutron source stellarator

On the path to a fusion pilot plant, Thea Energy plans to build Eos, a sub-breakeven, deuterium-deuterium, beam-target fusion, stellarator neutron source facility for producing tritium and other valuable radioisotopes. In this paper, a set of 1D plasma physics models are coupled and used to design the operating point of the facility and predict performance. At this foundational stage of the design, analytic and approximate models are sufficient to capture the leading-order effects, and fast enough to run in the inner loop of an optimizer. Higher-fidelity analyses will follow. Models of 1D profile-dependent neutral beam stopping, ion beam slowing down, beam-target fusion, electron-ion classical heat transfer, energy confinement (ISS04), beam pressure, beam heating of ions and electrons, beam-beam fusion fraction, and neutral beam injection and gyrotron heating electrical efficiencies are included. A numerical optimizer is used to determine the minimum required facility electric power to generate tritium at a given rate. A potentially advantageous regime is described in which modern precisely-quasisymmetric stellarators, new high-temperature superconductors, ITER-derived neutral beam injection, and new high-frequency gyrotrons enable a suitible target plasma with hot electrons, cold ions, peaked density and temperature profiles, and high beam-injected ion density. It appears possible at this time for a facility with a medium-scale and medium-strength stellarator whose required facility electric power is less than 40 MW to produce $2.5\times 10^{17}$ neutrons s -1 for the production of radioisotopes. With the addition of a tritium breeding blanket, such a facility could produce 0.2 grams d -1 or 70 grams yr -1 of tritium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First Ever Polymer Flood Field Pilot to Enhance the Recovery of Heavy Oils on Alaska North Slope – Producer Responses and Operational Lessons Learned

The US Department of Energy and Hilcorp Alaska, LLC are jointly cosponsoring a field pilot project entitled “First Ever Field Pilot on Alaska’s North Slope to Validate the Use of Polymer Floods for Heavy Oil Enhanced Oil Recovery (EOR).” The objective of this pilot is to perform a field experiment to validate the use of an advanced polymer flooding technology to unlock the vast heavy oil resources on Alaska North Slope (ANS). Two pairs of horizontal injection and production wells have been deployed in an isolated fault block of the Schrader Bluff heavy oil reservoir at the Milne Point Field to conduct a polymer flood pilot which was designed to acquire field performance data to optimize polymer flood design in the Schrader Bluff heavy oil reservoirs on ANS. Hydrolyzed polyacrylamide (HPAM) polymer injection started on August 28, 2018 using a custom made polymer mixing and pumping unit. Polymer solution properties such as concentration, viscosity, and filter ratio, have been closely monitored and adjusted as necessary. Operational procedures have been improved to ensure adequate injectivity and polymer propagation through the formation. Oil and water production is tested frequently to monitor water cut performance, and produced water is sampled and analyzed for polymer content. Tracers were pumped pre and post polymer injection startup to compare polymer flood breakthrough timing and sweep efficiency. Polymer injectivity of the horizontal wells drilled in the Schrader Bluff NB sand is found to be sufficient to replace the reservoir production voidage although there were some declines as high viscosity polymer swept the near wellbore region. Production data show significant reduction in water cut and the oil production rate has stabilized. No polymer production has been confirmed from the two horizontal producers after 22 months of polymer injection into the two supporting horizontal injectors. Tracer data show very low sweep efficiencies with waterflood alone, whereas significant improvement has been achieved with polymer flood. Many operational lessons have been learned and improvements have been made regarding polymer mixing, pumping, and onsite quality control, particularly in a challenging Arctic environment. Adequate polymer injection rate can be achieved with diligent monitoring and quality assurance of the properties of the injected polymer solution.

Ning, Samson↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

Robust Combined Heat and Hybrid Power (CHHP) for High Electrical Efficiency Cogeneration

Georgia Tech (Prime Recipient), the University of Texas at El Paso (UTEP) and the National Energy Technology Laboratory (NETL) investigated a hybrid fuel cell/ gas turbine system concept as a combined heat and hybrid power (CHHP) system for both robust and high power-to-process heat ratio cogeneration. The novelty of the proposed system entailed the distinct, elevated electrical efficiencies it maintains while simultaneously supporting a broad span of heating needs (e.g., supply temperatures) demanded across variable heat loads. The scope included: 1) leveraging a pioneering national lab facility configured for dynamic system operability development of hybrid fuel cell/gas turbine cycles; 2) enabling technology development to adjust and modulate the quality and quantity of thermal supply to bottoming heat loads via novel extreme temperature gas bypass valves. Hybrid fuel cell/gas turbine systems have primarily been reduced-to-practice in a constrained (e.g., initial proof-of-concept) manner and have still demonstrated considerable electrical efficiencies. However, these pre-pilot systems have focused upon electrical efficiencies and electrical power generation as the exclusive energy demand. Such hybrid systems had not been extensively researched or developed for flexible and variable operation consisting of both power and heat demands; however, these variable combined power and heat demands are characteristic of many types of manufacturers such as animal/poultry processing, bakeries and milk/flour/pastry manufacturing, textile mills, and electrochemical processing. Commercially, developing the system into a working combined heat and power system benefits these types of manufacturers by allowing them to meet their power and heat demands at a lower cost, higher efficiency, and/or through onsite generation. Therefore, the technical scope of this project was largely to study and facilitate these hybrid systems as combined heat and hybrid power (CHHP) systems that include dynamic operability for variable heat and power loads and/or grid dynamics for various types of manufacturers. Simulation results were used to predict the performance of the CHHP system and conceptually develop it to achieve desired dynamic operability. Experimentally, the primary goal was to design, manufacture, and experiment upon a high-temperature bypass valve. Experimental data included air mass flow rates through the valve orifice when the valve was changed to variable extent between fully closed and fully open. The experimental data was then used to create a semi-empirical computational model of the bypass valve. Concluded simulation goals for the research included developing computational heat exchanger models for the hybrid system inclusive of the bottoming heat exchanger and the recuperative heat exchanger, and then combining the computational recuperator model with the computational valve model. Afterwards, the computational models were then integrated to predict the dynamic operation of hybrid fuel cell/gas turbine cycles throughout a design space and reporting such. The scope stated in the preceding paragraph was packaged into five specific goals: 1) enabling the simulation of dynamic combined heat and power through the creation of computational, modular heat exchanger models; 2) simulation and exploration of the CHHP system’s performance by integrating the heat exchanger models with the national lab’s pre-existing hybrid system (computational) simulation, but without the recuperator bypass valve concept in order to initially determine how the (baseline) system behaves and can be controlled in order to meet variable heat and power demands; 3) development and initial deployment of the high-temperature recuperator bypass valve technology in order to confirm and characterize the approach; 4) usage of the experimental data for the valve to create a semi-empirical computational model for the bypass valve which could then be combined with the heat exchanger computational models; 5) repeat of the second task of simulating and exploring the system’s performance, but this time including the bypass valve to resolve its efficacy. Tasks were successfully completed, and the general notion of flexibly operating, high electrical efficiency CHHP was further corroborated. Supportive details are provided in the report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Probing the Origin of Changing-look Quasar Transitions with Chandra

Extremely variable quasars can also show strong changes in broad-line emission strength and are known as changing-look quasars (CLQs). To study the CLQ transition mechanism, we present a pilot sample of CLQs with X-ray observations in both the bright and faint states. From a sample of quasars with bright-state archival SDSS spectra and (Chandra or XMM-Newton) X-ray data, we identified five new CLQs via optical spectroscopic follow-up and then obtained new target-of-opportunity X-ray observations with Chandra. No strong absorption is detected in either the bright- or the faint-state X-ray spectra. The intrinsic X-ray flux generally changes along with the optical variability, and the X-ray power-law slope becomes harder in the faint state. Large-amplitude mid-infrared variability is detected in all five CLQs, and it echoes the variability in the optical with a time lag expected from the light-crossing time of the dusty torus for CLQs with robust lag measurements. The changing-obscuration model is not consistent with the observed X-ray spectra and spectral energy distribution changes seen in these CLQs. It is highly likely that the observed changes are due to the changing accretion rate of the supermassive black hole, so the multiwavelength emission varies accordingly, with promising analogies to the accretion states of X-ray binaries.

79 ASTRONOMY AND ASTROPHYSICS↗

Computationally-Aided Design of a Small-Scale Radioactive Waste Glass Melter

To provide mission support to the Hanford Waste Immobilization and Treatment Plant for the vitrification of legacy nuclear tank waste, a reduced-scale vitrification pilot system is being designed to process simulated and actual radioactive tank wastes. The tank waste will be separated into high-level waste (HLW) and low-activity waste (LAW) fractions, where the majority by mass (~90%) is LAW and by activity (>95%) is HLW. The first tank waste to be processed at the WTP will be LAW. Since Hanford tank waste and the resultant melter feed compositions are known to vary widely, pilot-scale operations are essential to identify potential problems, provide needed data, confirm assumptions, and determine impacts to full-scale melters and off-gas systems from these different feeds. In addition, the reduced-scale melter system must be capable of quickly providing results to operations without the typically high costs of radioactive operations and provide an engineering platform in close proximity to local operations staff. The objective is to produce similar process conditions to those encountered in the full-scale LAW melters and minimize the volume of radioactive waste necessary for the evaluations. To this end, melter design features are being explored to increase production without significantly increasing surface area, melter glass volumes or compromising data quality. In support of these objectives, a set of computational fluid dynamic models have been developed to provide insight into the flow patterns within these small melters and evaluate design features to increase production without significantly increasing glass inventory. Computed velocities were evaluated at the interface between the cold cap and the molten glass pool and within the bulk glass pool. A method was developed to correlate results to an estimated melt rate and down-select design features that produce the highest gains.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Computationally-Aided Design of a Small-Scale Radioactive Waste Glass Melter

To provide mission support to the Hanford Waste Immobilization and Treatment Plant for the vitrification of legacy nuclear tank waste, a reduced-scale vitrification pilot system is being designed to process simulated and actual radioactive tank wastes. The tank waste will be separated into high-level waste (HLW) and low-activity waste (LAW) fractions, where the majority by mass (~90%) is LAW and by activity (>95%) is HLW. The first tank waste to be processed at the WTP will be LAW. Since Hanford tank waste and the resultant melter feed compositions are known to vary widely, pilot-scale operations are essential to identify potential problems, provide needed data, confirm assumptions, and determine impacts to full-scale melters and off-gas systems from these different feeds. In addition, the reduced-scale melter system must be capable of quickly providing results to operations without the typically high costs of radioactive operations and provide an engineering platform in close proximity to local operations staff. The objective is to produce similar process conditions to those encountered in the full-scale LAW melters and minimize the volume of radioactive waste necessary for the evaluations. To this end, melter design features are being explored to increase production without significantly increasing surface area, melter glass volumes or compromising data quality. In support of these objectives, a set of computational fluid dynamic models have been developed to provide insight into the flow patterns within these small melters and evaluate design features to increase production without significantly increasing glass inventory. Computed velocities were evaluated at the interface between the cold cap and the molten glass pool and within the bulk glass pool. A method was developed to correlate results to an estimated melt rate and down-select design features that produce the highest gains.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Computationally Aided Design of a Small-Scale Waste-Glass Melter - 20452

To provide mission support to the WTP for the vitrification of legacy nuclear tank waste at the Hanford site, a reduced-scale vitrification pilot system is being designed to process simulated and actual radioactive tank wastes. The waste stored in underground tanks will be separated into HLW and LAW fractions, where the majority is LAW by mass (approximately 90%) and HLW by activity (greater than 95%). The first tank waste to be processed at the WTP will be LAW. Because Hanford tank waste and the resultant melter feed compositions are known to vary widely, pilot-scale operations are essential to identify potential problems, provide needed data, confirm assumptions, and determine impacts to full-scale melters and off-gas systems from these different feeds. In addition, the reduced-scale melter system must be capable of quickly providing results to operations without the typically high cost of full-scale radioactive operations and to provide an engineering platform in close proximity to local operations staff. The objectives of this computational modeling effort are to produce process conditions like those encountered in the WTP LAW melters and to minimize the volume of radioactive waste necessary for the evaluations. To this end, melter design features are being explored to increase production without significantly increasing surface area or melter-glass volumes or compromising data quality. In support of these objectives, a set of computational fluid dynamic models was developed to provide insight into the flow patterns within these small melters and evaluate design features to increase production without significantly increasing glass inventory. Computed velocities were evaluated at the interface between the cold cap and the molten-glass pool and within the bulk-glass pool. Since melt rate correlates with the velocity underneath the cold cap, this information can be used to select design features that produce the highest gains. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of Temperature on the Pilot-Scale Catalytic Pyrolysis of Loblolly Pine

A pilot-scale biomass catalytic pyrolysis unit with a nominal throughput of one tonne of biomass per day (1TPD) has been in operation since 2013 to investigate the process parameters that have the largest influence on biocrude yield, oxygen content, and chemical composition. A parametric study was conducted to investigate the effect of pyrolysis temperature, ranging from 433 to 581 °C, on biocrude yield and quality. A locally sourced loblolly pine feedstock and a commercially available, spray dried, nonzeolitic γ-Al 2 O 3 catalyst were used in individual experiments conducted at each pyrolysis temperature to achieve a minimum of 4 h of steady-state continuous operation. Typically, 600–800 kg of biomass was fed over a 12-h period, with one experiment extended to almost 29 h (1144-kg biomass fed) and one experiment interrupted by a process upset after just 7 h (411-kg biomass fed). Comprehensive analysis of collected gas, liquid, and solid products were used to calculate carbon balances (77% to 107%) for each experiment. The biocrude yield ranged from 12 to 18 wt % C and, in general, decreased with increasing pyrolysis temperature. The average steady-state biocrude yield as a function of temperature translated to a biocrude production rate between 40 and 50 gallons per dry ton. The biocrude oxygen content varied between 21 and 31 wt %, on a dry basis, and as expected, decreased with increasing pyrolysis temperature. The identified components in the semivolatile biocrude products are mostly methoxyphenols and other multiphenolic compounds. The multiphenolic compounds are demethoxylated at pyrolysis temperatures above 500 °C, producing biocrudes with higher concentrations of monophenols and polycyclic aromatic hydrocarbons. The concentration of anhydrosugars, like levoglucosan in the biocrudes, decreased with increasing pyrolysis temperature from ∼15 to ∼1 vol %.

biofuels↗

Combustion Performance and Emissions Optimization through Integration of Miniaturized High Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution of wall conditions in utility boilers. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of a coal-fired utility boiler in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

42 ENGINEERING↗