Nuclear Diagnostics for ICF: Towards Characterization of Plasma Variables
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Angular filter refractometry is an optical diagnostic that measures the absolute contours of a line-integrated density gradient by placing a filter with alternating opaque and transparent zones in the focal plane of a probe beam, which produce corresponding alternating light and dark regions in the image plane. Identifying transitions between these regions with specific zones on the angular filter (AF) allows the line-integrated density to be determined, but the sign of the density gradient at each transition is degenerate and must be broken using other information about the object plasma. Additional features from diffraction in the filter plane often complicate data analysis. Here, in this paper, we present an improved AF design that uses a stochastic pixel pattern with a sinusoidal radial profile to minimize unwanted diffraction effects in the image caused by the sharp edges of the filter bands. We also present a technique in which a pair of AFs with different patterns on two branches of the same probe beam can be used to break the density gradient degeneracy. Both techniques are demonstrated using a synthetic diagnostic and data collected on the OMEGA EP (extended performance) laser.
Three-dimensional reconstruction algorithms have been developed which determine the hot-spot velocity, hot-spot apparent ion temperature distribution, and fuel areal-density distribution present in laser-direct- drive inertial confinement fusion implosions on the OMEGA laser. These reconstructions rely on multiple independent measurements of the neutron energy spectrum emitted from the fusing plasma. Measurements of the neutron energy spectrum on OMEGA are made using a suite of quasi-orthogonal neutron time-of-flight detectors and a magnetic recoil spectrometer. These spectrometers are positioned strategically around the OMEGA target chamber to provide unique 3-D measurements of the conditions of the fusing hot spot and compressed fuel near peak compression. The uncertainties involved in these 3-D reconstructions are discussed and are used to identify a new nTOF diagnostic line of sight which when built will reduce the uncertainty in the hot-spot apparent ion temperature distribution from 700 to <400 eV.
High gain in hotspot-ignition inertial confinement fusion (ICF) implosions requires the propagation of thermonuclear burn from a central hotspot to the surrounding cold dense fuel. As ICF experiments enter the burning plasma regime, diagnostic signatures of burn propagation must be identified. In previous work [A. J. Crilly et al., Phys. Plasmas 27(1), 012701 (2020)], it has been shown that the spectral shape of the neutron backscatter edges is sensitive to the dense fuel hydrodynamic conditions. The backscatter edges are prominent features in the ICF neutron spectrum produced by the 180° scattering of primary deuterium–tritium fusion neutrons from ions. In this work, synthetic neutron spectra from radiation-hydrodynamics simulations of burning ICF implosions are used to assess the backscatter edge analysis in a propagating burn regime. Significant changes to the edge's spectral shape are observed as the degree of burn increases, and a simplified analysis is developed to infer scatter-averaged fluid velocity and temperature. The backscatter analysis offers direct measurement of the increased dense fuel temperatures that result from burn propagation.
A multi-dimensional incoherent Thomson scattering diagnostic system capable of measuring electron temperature anisotropies at the level of the electron velocity distribution function (EVDF) is implemented on the PHAse Space MApping facility to investigate electron energization mechanisms during magnetic reconnection. This system incorporates two injection paths (perpendicular and parallel to the axial magnetic field) and two collection paths, providing four independent EVDF measurements along four velocity space directions. For strongly magnetized electrons, a 3D EVDF comprised of two characteristic electron temperatures perpendicular and parallel to the local magnetic field line is reconstructed from the four measured EVDFs. As a result, validation of isotropic electrons in a single magnetic flux rope and a steady-state helicon plasma is presented.
This project aimed at establishing connections between fluid dynamics, kinetic theory, and string theory to develop new tools to characterize the far-from-equilibrium properties of relativistic systems, which are instrumental in understanding the emergence of liquid-like behavior of the quark-gluon plasma formed in heavy-ion collisions. This project investigated the fundamental properties of viscous fluids in the full nonlinear regime to pave the way for the systematic inclusion of viscous effects in future numerical simulations of neutron star mergers.
Fiber-optic bolometers (FOBs) designed for plasma radiation measurement in magnetically confined fusion environments have been previously developed and tested at the DIII-D tokamak. These FOBs utilize a silicon Fabry–Perot interferometer at the fiber tip for temperature measurement and a gold disk as a radiation absorber. This paper presents recent advancements in the development of FOBs with reduced cooling time constants and enhanced temperature tolerance. We also demonstrate high-temperature operation and report findings from irradiation tests. By incorporating a copper sensor holder as a thermal sink and integrating two closely packed sensor heads into a compact design, the cooling time constants were reduced to ∼100 ms in vacuum, while minimizing uncertainties caused by temperature gradients. The FOBs were subjected to heating at 400 °C for five hours, with no observed degradation in noise performance post-heating. High-temperature operation tests were conducted at ∼220 °C using a 404 nm square-wave modulated laser to simulate the plasma radiation. In addition, four FOBs constructed from copper-coated pure-silica fibers were fabricated and underwent irradiation testing, enduring a total γ-radiation dose of 15.2 MGy and a neutron fluence of 1.6 × 10 18 n/cm 2 . As a result, the FOBs maintained their physical integrity and the optical signal shows high visibility throughout the test.
The Cooperative Research and Development Agreement (CRADA) between Oak Ridge National Laboratory (ORNL) and TAE Technologies (TAE) focused on a feasibility study of Doppler-free saturation spectroscopy (DFSS) as a diagnostic strategy to measure the internal magnetic and electric fields of TAE’s C-2W field-reversed configuration (FRC) fusion device. Non-perturbative measurements of magnetic and electric fields in the core of FRCs can provide critical information needed to constrain equilibrium models and for the continued advancement of the fusion research program at TAE. DFSS is a well-established, laser-based absorption spectroscopy technique used to suppress inhomogeneous (Doppler) broadening linewidths and reveal Zeeman/Stark split hyperfine structures of target emission lines. The collaboration involved the use of ORNL’s suite of experimentally validated quantum mechanical modelling codes to simulate theoretical atomic spectra for a variety of machine parameters and laser beam configurations. TAE’s expertise was heavily used to provide measurements/models of the required machine parameters needed as inputs to the simulations. Results of an all-encompassing error analysis demonstrate the favourable capabilities of the diagnostic and provided invaluable insights as to how DFSS can be best used to accurately measure internal B/E-fields in C-2W.
A prototype infrared video bolometer (IRVB) was successfully deployed in the Mega Ampere Spherical Tokamak Upgrade (MAST Upgrade or MAST-U), the first deployment of such a diagnostic in a spherical tokamak. The IRVB was designed to study the radiation around the lower x-point, another first in tokamaks, and has the potential to estimate emissivity profiles with spatial resolution beyond what is achievable with resistive bolometry. The system was fully characterized prior to installation on MAST-U, and the results are summarized here. After installation, it was verified that the actual measurement geometry in the tokamak qualitatively matches the design; this is a particularly difficult process for bolometers and was done using specific features of the plasma itself. The installed IRVB measurements are consistent both with observations from other diagnostics, including magnetic reconstruction, visible light cameras, and resistive bolometry, as well as with the IRVB-designed view. Early results show that with conventional divertor geometry and only intrinsic impurities (for example, C and He), the progression of radiative detachment follows a similar path to that observed for large aspect ratio tokamaks: The peak of the radiation moves along the separatrix from the targets to the x-point and high-field side midplane with a toroidally symmetric structure that can eventually lead to strong effects on the core plasma inside the separatrix.
Shock-driven implosions with 100% deuterium (D 2 ) gas fill compared to implosions with 50:50 nitrogen-deuterium (N 2 D 2 ) gas fill have been performed at the OMEGA laser facility to test the impact of the added mid-Ζ fill gas on implosion performance. Ion temperature (Τ ion ) as inferred from the width of measured DD-neutron spectra is seen to be 34%±6% higher for the N 2 D 2 implosions than for the D 2 -only case, while the DD-neutron yield from the D 2 -only implosion is 7.2±0.5 times higher than from the N 2 D 2 gas fill. The T ion enhancement for N 2 D 2 is observed in spite of the higher Z, which might be expected to lead to higher radiative loss, and higher shock strength for the D 2 -only versus N 2 D 2 implosions due to lower mass, and is understood in terms of increased shock heating of N compared to D, heat transfer from N to D prior to burn, and limited amount of ion-electron-equilibration-mediated additional radiative loss due to the added higher-Z material. Further, this picture is supported by interspecies equilibration timescales for these implosions, constrained by experimental observables. The one-dimensional (1D) kinetic Vlasov-Fokker-Planck code ifp and the radiation hydrodynamic simulation codes hyades (1D) and xrage [1D, two-dimensional (2D)] are brought to bear to understand the observed yield ratio. Comparing measurements and simulations, the yield loss in the N 2 D 2 implosions relative to the pure D 2 -fill implosion is determined to result from the reduced amount of D 2 in the fill (fourfold effect on yield) combined with a lower fraction of the D 2 fuel being hot enough to burn in the N 2 D 2 case. The experimental yield and T ion ratio observations are relatively well matched by the kinetic simulations, which suggest interspecies diffusion is responsible for the lower fraction of hot D 2 in the N 2 D 2 relative to the D 2 -only case. The simulated absolute yields are higher than measured; a comparison of 1D versus 2D XRAGE simulations suggest that this can be explained by dimensional effects. The hydrodynamic simulations suggest that radiative losses primarily impact the implosion edges, with ion-electron equilibration times being too long in the implosion cores. The observations of increased T ion and limited additional yield loss (on top of the fourfold expected from the difference in D content) for the N 2 D 2 versus D 2 -only fill suggest it is feasible to develop the platform for studying CNO-cycle-relevant nuclear reactions in a plasma environment.
The Particle Time of Flight (PTOF) diagnostic is a chemical vapor deposition diamond-based detector and is the only diagnostic for measuring nuclear bang times of low yield (<1013) shots on the National Ignition Facility. Recently, a comprehensive study of detector impulse responses revealed certain detectors with very fast and consistent impulse responses with a rise time of <50 ps, enabling low yield burn history measurements. At the current standoff of 50 cm, this measurement is possible with fast 14 MeV neutrons from deuterium–tritium (DT) fusion plasmas. PTOF-inferred DT burn width numbers compare well with widths inferred from the gamma reaction history diagnostic on mid-yield (1013–1015) shots, where both systems are capable of making this measurement. These new capabilities could be extended to 2.5 MeV deuterium–deuterium neutrons from D plasmas and to even lower yield by reducing the detector standoff distance to 10 cm; a design for this is also presented.
Here, we present the development of a compact Thomson parabola ion spectrometer capable of characterizing the energy spectra of various ion species of multi-MeV ion beams from >10 20 W/cm 2 laser produced plasmas at rates commensurate with the highest available from any of the current and near-future PW-class laser facilities. This diagnostic makes use of a polyvinyl toluene based fast plastic scintillator (EJ-260), and the emitted light is collected using an optical imaging system coupled to a thermoelectrically cooled scientific complementary metal–oxide–semiconductor camera. This offers a robust solution for data acquisition at a high repetition rate, while avoiding the added complications and nonlinearities of micro-channel plate based systems. Different ion energy ranges can be probed using a modular magnet setup, a variable electric field, and a varying drift-distance. We have demonstrated operation and data collection with this system at up to 0.2 Hz from plasmas created by irradiating a solid target, limited only by the targeting system. With the appropriate software, on-the-fly ion spectral analysis will be possible, enabling real-time experimental control at multi-Hz repetition rates.
Inertial Confinement Fusion produces energy from a burning plasma lasting a fraction of a nanosecond. Power plant designs based on Inertial Fusion Energy (IFE) will need to ignite targets 1-10 times a second, fired as projectiles into a chamber and delivering the driver to the target location. Driver asymmetry is known to impact ICF experiments at gain near unity and remains a candidate for primary yield degradation, and therefore fusion power plant energy output, for high-gain target designs. For a Fusion Power Plant (FPP), continuous and real-time monitoring of target performance provides an opportunity to stabilize or correct the target-driver registration. This requires x-ray and neutron imaging with a large field-of-view, sufficiently high resolution, fast analysis and to subtend a minimal solid angle. We introduce design criteria for such an imaging system that uses a coded aperture and time-gated, lens-coupled scintillators as a viable solution and outline the research steps required to field such a system. Integrating the imaging system into an IFE power plant as part of an active feedback loop could increase average power output by reducing the failure rate due to mis-aligned drivers with respect to the target.
Neutron radiography is a technique uniquely suited to applications in nuclear diagnostics, non-destructive testing, and subcritical experiments. The spatial resolution of neutron radiographs is degraded by optical blur in the imaging system and the neutron source size, where the ideal source is point-like to optimize the point-spread function. A potential neutron source for radiography is the dense plasma focus (DPF), a coaxial Z-pinch that produces thermonuclear and beam-target neutrons. To assess if the source size is suitable for radiography, a neutron imaging system was used to measure the source size of the 4 MA Sodium DPF at the Nevada National Security Site operating with deuterium–tritium gas-fill. The source size was measured using the edge-spread function of tungsten objects, each having a rolled (convex) edge. The spot size was found to be 7–12 mm full-width at half-max (FWHM) assuming a Gaussian source, though comparison is presented for Lorentzian and Bennett distributions. The average FWHM was found to be 8.6 ± 1.2 mm vertically and 10.8 ± 1.2 mm horizontally with respect to the image plane, averaging over varied edges and alignments. The results were sensitive to source alignment and edge metrology, which introduced notable uncertainties. These results are consistent with separate experimental measurements as well as magnetohydrodynamics simulations of this DPF, which suggest that neutron production can originate from pinches ∼5–7 mm off-axis. These results suggest that the DPF should be used for radiography at low magnification (M < 1) where spot size does not dominate spatial blur.
Recent deuterium-tritium (D-T)–layered implosion experiments at the National Ignition Facility have achieved a burning plasma and >1-MJ neutron yield. A series of repeat experiments have shown that the degree of performance is very likely dependent on capsule quality, including the quantity of what are collectively termed “high- Z particles.” These particles are detected on a custom-built radiography system, known as the Sagometer, during the final target qualification process. The term particles is misleading, as the source of these nonuniformities in the capsule images is uncertain; the term detection will be used instead. An increased number of D-T targets have been rejected at the final stages of production due to Sagometer detections. Late detections are deleterious in terms of loss of production parts, effort, and overall operating efficiency. In response, we undertook an effort to determine the origin of these detections and to ultimately mitigate target losses caused by them. Through careful testing and analysis, we have determined neither insufficient production cleanliness nor hohlraum shedding is responsible for the detections on the capsule. Here, we determined that the detections are inherent to the capsule and have made efforts to use the Zeiss Xradia to identify them earlier in the production process. While testing revealed the Xradia is not currently sufficient for identifying such particles using radiography images, we continue to look to other forms of metrology to down select the capsules early in the process.
A new detector design has been fielded on the Omega-60 laser facility using a D 3 He backlighter capsule to radiograph a magnetized experiment. D 3 He capsules produce a low flux (~ 10 8 total yield in 4π) of protons requiring detectors with close-to single-particle sensitivity to be employed. The new detector stack consisted of both imaging plate (IP) and CR-39 to detect 14.7 MeV protons where, historically, only CR-39 has been used. IP is sensitive to significant contributions in signal from both x-rays and protons so additional filtering has to be added to attenuate the x-rays. Here, the signals and features observed from a single shot are detected by both IP and CR-39, giving confirmation that it is protons creating the signatures on the IP. Measurements of PSL/pixel are used to calculate approximate on-shot proton yields and agree with commonly measured yields. A second IP is used at the rear of the stack to measure, and subsequently remove, a background signal. The spatial resolution at the IP is limited, primarily, by a range of proton energies with varying deflections being recorded at the detector, causing potential ‘blurring’ of features. We find for this setup that the blurring effect is less than the smallest identifiable features observed at the detector, and therefore of minimal impact. A large benefit to this new stack design is that IP can be scanned and processed on much faster timescales than CR-39 allowing for prompt shot feedback. Future designs and modifications to the stack design fielded on this experiment could help improve the contrast of the radiograph on IP, as well as detecting protons produced at alternative energies.
The rapid transient method records time stamps of individual ion arrival for accurate identification and quantification of nanoparticles.
We have commissioned a new time-resolved, x-ray imaging diagnostic for the Z facility. The primary intended application is for diagnosing the stagnation behavior of Magnetized Liner Inertial Fusion (MagLIF) and similar targets. We have a variety of imaging systems at Z, both time-integrated and time-resolved, that provide valuable x-ray imaging information, but no system at Z up to this time provides a combined high-resolution imaging with multi-frame time resolution; this new diagnostic, called TRICXI for Time Resolved In-Chamber X-ray Imager, is meant to provide time-resolved spatial imaging with high resolution. The multi-frame camera consists of a microchannel plate camera. A key component to achieving the design goals is to place the instrument inside the Z vacuum chamber within 2 m of the load, which necessitates a considerable amount of x-ray shielding as well as a specially designed, independent vacuum system. Here, a demonstration of the imaging capability for a series of MagLIF shots is presented. Predictions are given for resolution and relative image irradiance to guide experimenters in choosing the desired configuration for their experiments.