At least 235 records · Page 13

Low Carbon Technology Strategies: Hospital

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon hospitals within their existing building portfolios. Hospitals typically include complex heating and cooling systems and specialty medical equipment.

analytics↗

Low Carbon Technology Strategies: Small Hotel

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon small hotels within their existing building portfolios. Small hotels are typically four floors or less and less than 50,000 square feet and often use packaged rooftop units for heating, cooling, and ventilation.

analytics↗

Low Carbon Technology Strategies: Stand-Alone Retail and Strip Mall

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon retail buildings within their existing building portfolios. Stand-alone retail and strip malls often use packaged rooftop units for heating, cooling, and ventilation.

analytics↗

Medical Imaging Equipment Energy Efficiency

The energy use of medical imaging equipment (MIE) in healthcare facilities is estimated to be about 5% of total site energy use. MIE energy use is only expected to increase as technology advances and more patients seek services from MIE, enabling more facilities to install additional MIE. Healthcare organizations need reliable information regarding comprehensive energy use or lifetime energy costs with which to make energy-efficient MIE procurement decisions, and there are currently no MIE energy or efficiency standards in the United States (U.S.). This fact sheet provides background on MIE energy consumption, key terms, and guidance on why and how to meter MIE, helping stakeholders make informed decisions to enhance their facility's performance.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Quick-connect scanning tunneling microscope head with nested piezoelectric coarse walkers

To meet changing research demands, new scanning tunneling microscope (STM) features must constantly evolve. We describe the design, development, and performance of a modular plug-in STM, which is compact and stable. The STM head is equipped with a quick-connect socket that is matched to a universal connector plug, enabling it to be transferred between systems. This head can be introduced into a vacuum system via a load-lock and transferred to various sites equipped with the connector plug, permitting multi-site STM operation. Its design allows for reliable operation in a variety of experimental conditions, including a broad temperature range, ultra-high vacuum, high magnetic fields, and closed-cycle pulse-tube cooling. The STM’s compact size is achieved by a novel nested piezoelectric coarse walker design, which allows for large orthogonal travel in the X, Y, and Z directions, ideal for studying both bulk and thin film samples ranging in size from mm to μm. Its stability and noise tolerance are demonstrated by achieving atomic resolution under ambient conditions on a laboratory desktop with no vibrational or acoustic isolation. The operation of the nested coarse walkers is demonstrated by successful navigation to a μm-sized 2D sample.

Instruments & Instrumentation↗

Thermal Load Reduction System Development in a Hyundai Sonata PHEV

Increased market penetration of electric drive vehicles (EDVs) requires overcoming a number of hurdles, including limited vehicle range and the elevated cost in comparison to conventional vehicles. Climate control loads have a significant impact on range, cutting it by over 50% in both cooling and heating conditions. To minimize the impact of climate control on EDV range, the National Renewable Energy Laboratory has partnered with Hyundai America and key industry partners to quantify the performance of thermal load reduction technologies on a Hyundai Sonata plug-in hybrid electric vehicle. Technologies that impact vehicle cabin heating in cold weather conditions and cabin cooling in warm weather conditions were evaluated. Tests included thermal transient and steady-state periods for all technologies, including the development of a new test methodology to evaluate the performance of occupant thermal conditioning. Heated surfaces demonstrated significant reductions in energy use from steady-state heating, including a 29%-59% reduction from heated surfaces. Solar control glass packages demonstrated significant reductions in energy use for both transient and steady-state cooling, with up to a 42% reduction in transient and 12.8% reduction in steady-state energy use for the packages evaluated. Technologies that demonstrated significant climate control load reduction were selected for incorporation into a complete thermal load reduction package. The complete package is set to be evaluated in the second phase of the ongoing project.

33 ADVANCED PROPULSION SYSTEMS↗

The Effect of Spark-Plug Heat Dispersal Range and Exhaust Valve Opening Timing on Cold-Start Emissions and Cycle-to-Cycle Variability

The partnership for advancing combustion engines (PACE) is a US Department of Energy consortium involving multiple national laboratories and includes a goal of addressing key efficiency and emission barriers in light-duty engines fueled with a market-representative E10 gasoline. A major pillar of the initiative is the generation of detailed experimental data and modeling capabilities to understand and predict cold-start behavior. Cold-start, as defined by the time between first engine crank and three-way catalyst light-off, is responsible for a large percentage of NOx, unburned hydrocarbon and particulate matter emissions in light-duty engines. Minimizing emissions during cold-start is a trade-off between achieving faster light-off of the three-way catalyst and engine out emissions during that period. In this study, gaseous and soot emissions were measured at a distance representative of the three-way catalyst position downstream of the engine at a 2 bar net indicated mean effective pressure (NIMEP) steady-state operating condition representative of cold-start. The test matrix included sweeps of ignition timing 15 degrees-before to 10 degrees-after top dead center firing (TDCf) across three different spark-plug heat dispersal ranges (HR). Additionally, the effect of varying exhaust valve opening (EVO) timing on combustion stability and emissions was also studied. Results show that the spark plug HR affects the coefficient of variation (COV) of NIMEP under all cold-start conditions, while the impact on emissions was found to be minimal. At very retarded spark timings, colder spark plugs required higher air and fuel flow to maintain the desired 2bar NIMEP load, but the fraction of fuel energy going into the exhaust was found to be similar for all spark plugs. Finally, retarding exhaust valve timings showed a simultaneous reduction in emissions while increasing the fraction of fuel energy being fed into the exhaust. However, engine COV was also observed to increase with retarded exhaust timings.

42 ENGINEERING↗

Plug-in connector socket accepts coaxial cable end

Connector which includes a spring-loaded contact to receive a protruding center conductor and an internal collet to clamp against a collar attached to a woven outer conductor, is used as a receptacle for the end of a coaxial cable. This plug-in connector socket is used successfully with remote manipulators.

Mitchell, D.↗

Achieving Very High Efficiency and Net Zero Energy in an Existing Home in a Hot-Humid Climate: Long-Term Utility and Monitoring Data (Revised)

This study summarizes the first six months of detailed data collected on a single family home that experienced a series of retrofits targeting reductions in energy use. The project was designed to develop data on how envelope modifications and renewable measures can result in considerable energy reductions and potentially net zero energy for an existing home. Originally published in February2012, this revised version of the report contains further research conducted on the Parker residence. Key updates include one full year of additional data, an analysis of cooling performance of the mini-split heat pump, an evaluation of room-to-room temperature distribution, and an evaluation of plug-in automobile charging performance, electricity consumption, and load shape.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Achieving Very High Efficiency and Net Zero Energy in an Existing Home in a Hot-Humid Climate: Long-Term Utility and Monitoring Data

This study summarizes the first six months of detailed data collected on a single family home that experienced a series of retrofits targeting reductions in energy use. The project was designed to develop data on how envelope modifications and renewable measures can result in considerable energy reductions and potentially net zero energy for an existing home. Originally published in February 2012, this revised version of the report contains further research conducted on the Parker residence. Key updates include one full year of additional data, an analysis of cooling performance of the mini-split heat pump, an evaluation of room-to-room temperature distribution, and an evaluation of plug-in automobile charging performance, electricity consumption, and load shape.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Motor Controller

M.H. Marks Enterprises' Power Factor Controller (PFC) matches voltage with motor's actual need. Plugged into a motor, PFC continuously determines motor load by sensing shifts between voltage and current flow. When it senses a light load, it cuts voltage to the minimum needed. It offers potential energy savings ranging from eight percent up to 65 percent depending on the application. Myles Marks started out with the notion of writing an article for Popular Electronics magazine at the same time offering to furnish kits to readers interested in assembling PFC's. Within two weeks from publication he had orders for 500 kits and orders are still coming three years later.

Source record↗

Transient Pressure Test Article (TPTA) 1.1 and 1.1A, volume 1

This final test report presents the results obtained during the static hot firing and cold-gas high Q tests of the first Transient Pressure Test Article (TPTA) 1.1. The TPTA consisted of field test joints A and B, which were the original RSRM J-insulation configuration, with a metal capture feature. It also consisted of a flight configuration nozzle-to-case test joint (Joint D) with shorter vent slots. Fluorocarbon O-rings were used in all the test joints. The purpose of the TPTA tests is to evaluate and characterize the RSMR field and nozzle-to-case joints under the influence of ignition and strut loads during liftoff anf high Q. All objectives of the cold-gas high Q (TPTA 1.1A) test were met and all measurements were close to predicted values. During the static hot-firing test (TPTA 1.1), the motor was inadvertently plugged by the quench injector plug, making it a more severe test, although no strut loads were applied. The motor was depressurized after approximately 11 min using an auxiliary system, and no anomalies were noted. In the static hot-firing test, pressure was incident on the insulation and the test joint gaps were within the predicted range. During the static hot-firing test, no strut loads were applied because the loading system malfunctioned. For this test, all measurements were within range of similar tests performed without strut loads.

Rebells, Clarence A.↗

Failure prediction of thin beryllium sheets used in spacecraft structures

The primary objective of this study is to develop a method for prediction of failure of thin beryllium sheets that undergo complex states of stress. Major components of the research include experimental evaluation of strength parameters for cross-rolled beryllium sheet, application of the Tsai-Wu failure criterion to plate bending problems, development of a high order failure criterion, application of the new criterion to a variety of structures, and incorporation of both failure criteria into a finite element code. A Tsai-Wu failure model for SR-200 sheet material is developed from available tensile data, experiments carried out by NASA on two circular plates, and compression and off-axis experiments performed in this study. The failure surface obtained from the resulting criterion forms an ellipsoid. By supplementing experimental data used in the the two-dimensional criterion and modifying previously suggested failure criteria, a multi-dimensional failure surface is proposed for thin beryllium structures. The new criterion for orthotropic material is represented by a failure surface in six-dimensional stress space. In order to determine coefficients of the governing equation, a number of uniaxial, biaxial, and triaxial experiments are required. Details of these experiments and a complementary ultrasonic investigation are described in detail. Finally, validity of the criterion and newly determined mechanical properties is established through experiments on structures composed of SR200 sheet material. These experiments include a plate-plug arrangement under a complex state of stress and a series of plates with an out-of-plane central point load. Both criteria have been incorporated into a general purpose finite element analysis code. Numerical simulation incrementally applied loads to a structural component that is being designed and checks each nodal point in the model for exceedance of a failure criterion. If stresses at all locations do not exceed the failure criterion, the load is increased and the process is repeated. Failure results for the plate-plug and clamped plate tests are accurate to within 2 percent.

Roschke, Paul N.↗

Direct measurement and calculation of rubber bulk modulus by piston-cylinder method using conventional mechanical testing equipment

This article describes a method to directly measure the bulk modulus of rubber using a piston-cylinder type apparatus. The function of the testing apparatus is to reliably transfer load to the water inside the vessel and allow for the accurate and continuous measurement of volumetric displacement as the contents are compressed. During the test, load is applied to a piston-cylinder containing the rubber test sample and water using a conventional mechanical testing load frame. Load and the travel of the piston are recorded by a load cell and extensometer, respectfully. A brass or stainless steel plug of the same dimensions as the test sample is tested as a control sample to isolate the compliance of the system, including the compressibility of water and compliance of the piston-cylinder. The results from this control test are used to disincorporate the compliance of the system from the sample test results. Load-linear displacement data are mathematically converted to pressure-volumetric displacement data, from which bulk modulus is calculated. The test apparatus and method are validated using the known bulk modulus of water. Finally, the bulk modulus for two similar rubbers is evaluated. The validity of the results and limitations of the device are discussed.

36 MATERIALS SCIENCE↗

Optimal distribution system restoration using PHEVs

Power outages cost billions of dollars every year and jeopardise the lives of hospital patients. Traditionally, power distribution system takes a long time to recover after a major blackout, due to its top-down operation strategy. New technologies in modern distribution systems bring opportunities and challenges to distribution system restoration. As fast response energy resources, plug-in hybrid electric vehicles (PHEVs) can accelerate the load pickup by compensating the imbalance between available generation and distribution system load. This study provides a bottom-up restoration strategy to use PHEVs for reliable load pickup and faster restoration process. The optimisation problem of finding load pickup sequence to maximise restored energy is formulated as a mixed integer linear programming (MILP) problem. Moreover, the coordination between transmission and distribution restoration is developed to efficiently restore the entire system back to normal operating conditions. Simulation results on one 100-feeder test system demonstrate the efficiency of MILP-based restoration strategy and the benefit from PHEVs to restore more energy in given restoration time. The proposed restoration strategy has great potential to facilitate system operators to achieve efficient system restoration plans. It also provides incentives to deploy a large amount of PHEVs to improve system resiliency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Irvine Smart Grid Demonstration, a Regional Smart Grid Demonstration Project

ISGD was a comprehensive demonstration that spanned the electricity delivery system and extended into customer homes. The project used phasor measurement technology to enable substation-level situational awareness, and demonstrated SCE’s next-generation substation automation system. It extended beyond the substation to evaluate the latest generation of distribution automation technologies, including looped 12-kV distribution circuit topology using URCIs. The project team used DVVC capabilities to demonstrate CVR. In customer homes, the project evaluated HAN devices such as smart appliances, programmable communicating thermostats, and home energy management components. The homes were also equipped with energy storage, solar PV systems, and a number of energy efficiency measures (EEMs). The team used one block of homes to evaluate strategies and technologies for achieving ZNE. A home achieves ZNE when it produces at least as much renewable energy as the amount of energy it consumes annually. The project also assessed the impact of device-specific demand response (DR), as well as load management capabilities involving energy storage devices and plug-in electric vehicle charging equipment. In addition, the ISGD project sought to better understand the impact of ZNE homes on the electric grid. ISGD’s SENet enabled end-to-end interoperability between multiple vendors’ systems and devices, while also providing a level of cybersecurity that is essential to smart grid development and adoption across the nation. The ISGD project includes a series of sub-projects grouped into four logical technology domains: Smart Energy Customer Solutions, Next-Generation Distribution System, Interoperability and Cybersecurity, and Workforce of the Future. Section 2.3 provides a more detailed overview of these domains.

25 ENERGY STORAGE↗

Quantifying Leak Rates and Vacuum Impact on Granular Soil Column Pneumatic Seal

Introduction: All In-Situ Resource Utilization (ISRU) regolith reactor systems that aim to extract gases or vapors must maintain a seal along the flow path of the regolith from the inlet hopper to where extracted gases or vapors are generated. Using a column of regolith at the inlet has been proposed as an alternative to systems using series of mechanical valves to reduce mass and complexity. Preliminary investigations into the use of regolith itself as a barrier to escaping fluids have been conducted, which this research seeks to expand upon. Different vertical regolith simulant plug diameters and heights were tested under vacuum with dry nitrogen to observe leak rates and approximate steady state pressure gradient equilibria. The effect of absolute ambient pressure was also studied by repeating tests at incremental pressures ranging from 10e-5 Torr up to 1 atm to corroborate ambient bench tests from previous work. The impact of regolith dynamics was addressed to emulate continuous-feed regolith reaction processes by measuring leak rates through continuously draining simulant columns. OB-1 lunar highlands regolith simulant was used. Experimental Setup: Regolith simulant columns were constructed using a motorized butterfly valve separating upper acrylic tubes of various diameters from a larger, lower aluminum pipe plenum (See Figure 1). The butterfly valve was cracked open such that gas could freely pass through whereas regolith would bridge and stay suspended as a cohesive plug above in the acrylic portion. These assemblies were loaded into a vacuum chamber, and a compressed dry nitrogen line was routed into the lower plenum. Pressure transducers measured the absolute pressure of the lower plenum, which was compared to absolute chamber pressure to monitor the pressure gradient across the regolith simulant. A precision mass flow controller enabled fine control of plenum pressure. The plenum pressure was quasi-statically increased to set points informed by previous work [1] before shutting off the gas supply to allow the now pressurized gas volume to dissipate through the simulant into the chamber in what was referred to as a ‘leak test.’ In a separate set of tests, the pressure was allowed to quasi-statically build until visual disturbances in the soil were observed via remote camera feeds. Initial leak rate tests were repeated on the disturbed soil to observe changes in leak rates between initial as-poured and post-bubbling soil conditions. This test schedule was applied to simulant columns of three different diameters (approximately 2, 4, and 6 inches) as well as two different heights (around 8 and 16 inches) and was repeated at least three times for each configuration. Plenums were also pressurized while the butterfly valves were opened slightly further to facilitate slow, controlled, constant flowrate draining of the simulant to observe the impact that continuous-feed systems might have on leak rate through the regolith column. Finally, the regolith columns were reset and refilled and static leak rate tests were repeated approximately every decade in ambient pressure from 10e-5 Torr up to ambient conditions to observe the impact of transitioning out of the molecular flow regime on regolith column seal performance. Analysis: Trends with respect to each factor examined were constructed and reported alongside commentary on the most likely responsible physical phenomena. Confidence intervals were applied to the predictive findings of the data by quantifying instrumentation error and accounting for probabilistic impacts of curve fitting the generic exponential function onto pressure decay data. The leak rate is assumed directly proportional to the exponential term coefficient, while the steady-state static pressure gradient is assumed to be the asymptotic limit of each curve fit. Finally, a generic model developed by Ogino et al. [2] and later tuned for ambient testing was re-tuned using vacuum data to estimate leak rates on the lunar surface. Results: Pressure decay rates decreased up to 27-fold under vacuum when compared to ambient pressure, as shown in Figure 2. Simulant column diameter was found to exponentially correlate to both regolith column leak rate and steady-state equilibrium pressure delta. Height was found to be linearly related to leak rate –doubling the regolith column height consistently yielded around a 40% reduction in leak rate. Dynamic regolith draining was found to slightly increase leak rate, although to a lower degree than expected. Conclusion: Because of the transition into molecular gas flow through regolith, vacuum testing is required to properly estimate performance. Regolith columns should be designed as narrow as possible to avoid bridging and minimize leak rate, and as tall as is feasible to both further reduce leak rate and to help prevent bubbling, which has been shown to degrade the quality of the regolith seal. Disrupted soil was found to exhibit higher leak rates than pristine, as-poured soil, indicating the need to consider the impact of recovery from depressurization events. Regolith columns appear equally feasible for both dosed and continuous-feed reactors.

ISRU↗