At least 235 records · Page 13

SeaWiFS technical report series. Volume 11: Analysis of selected orbit propagation models for the SeaWiFS mission

An analysis of orbit propagation models was performed by the Mission Operations element of the Sea-viewing Wide Field-of-View Sensor (SeaWiFS) Project, which has overall responsibility for the instrument scheduling. The orbit propagators selected for this analysis are widely available general perturbations models. The analysis includes both absolute accuracy determination and comparisons of different versions of the models. The results show that all of the models tested meet accuracy requirements for scheduling and data acquisition purposes. For internal Project use the SGP4 propagator, developed by the North American Air Defense (NORAD) Command, has been selected. This model includes atmospheric drag effects and, therefore, provides better accuracy. For High Resolution Picture Transmission (HRPT) ground stations, which have less stringent accuracy requirements, the publicly available Brouwer-Lyddane models are recommended. The SeaWiFS Project will make available portable source code for a version of this model developed by the Data Capture Facility (DCF).

Patt, Frederick S.↗

Pushing the Limits of Aquatic Remote Sensing: Synthetic Data and Deep Learning for Fast Inverse Emulation of A Coupled Ocean-Atmosphere Radiative Transfer Model

The inversion of electromagnetic information to physical and biological properties of the water column is a notoriously difficult problem, yet fundamental to our ability of understanding aquatic processes on large time and space scales. There is now a growing necessity to develop pragmatic approaches that allow timely and effective extrapolation of local processes, to spatially resolved global products, and to promote operational and sustainable resource policy management. This presentation will discuss research integrating advanced biological and radiative modeling, high-end computation, and machine learning to develop a portable global processor for simultaneous retrieval of atmosphere and water optics for diverse aquatic systems from the open and coastal ocean to optically extreme inland waters and harmful algal blooms. We will discuss some of the basic concepts behind the forward modeling approach including DEAP, the novel Distributed Equivalent Algal Populations model, for developing large spectral libraries of aquatic particle optics to aid in our ability to distinguish phytoplankton functional types (PFTs) and inorganic material, as well as other factors which enable comprehensive modeling from the benthos to top-of-atmosphere (TOA). This information is being used to understand how we can leverage next-generation deep learning methods for maximum information retrieval and rapid image processing, while also providing capabilities to identify minimum sensor spectral requirements necessary for certain aquatic applications. Further, I will touch on how we envision this research to enable the aquatic community for science discovery and how we are moving closer towards the capability for high-fidelity global analysis of aquatic ecosystems.

Jeremy Alan Kravitz↗

Portable Apparatus for Electrochemical Sensing of Ethylene

A small, lightweight, portable apparatus based on an electrochemical sensing principle has been developed for monitoring low concentrations of ethylene in air. Ethylene has long been known to be produced by plants and to stimulate the growth and other aspects of the development of plants (including, notably, ripening of fruits and vegetables), even at concentrations as low as tens of parts per billion (ppb). The effects are magnified in plant-growth and -storage chambers wherein ethylene can accumulate. There is increasing recognition in agriculture and related industries that it is desirable to monitor and control ethylene concentrations in order to optimize the growth, storage, and ripening of plant products. Hence, there are numerous potential uses for the present apparatus in conjunction with equipment for controlling ethylene concentrations. The ethylene sensor is of a thick-film type with a design optimized for a low detection limit. The sensor includes a noble metal sensing electrode on a chip and a hydrated solid-electrolyte membrane that is held in contact with the chip. Also located on the sensor chip are a counter electrode and a reference electrode. The sensing electrode is held at a fixed potential versus the reference electrode. Detection takes place at active-triple-point areas where the sensing electrode, electrolyte, and sample gas meet. These areas are formed by cutting openings in the electrolyte membrane. The electrode current generated from electrochemical oxidation of ethylene at the active triple points is proportional to the concentration of ethylene. An additional film of the solid-electrolyte membrane material is deposited on the sensing electrode to increase the effective triple-point areas and thereby enhance the detection signal. The sensor chip is placed in a holder that is part of a polycarbonate housing. When fully assembled, the housing holds the solid-electrolyte membrane in contact with the chip (see figure). The housing includes a water reservoir for keeping the solid-electrolyte membrane hydrated. The housing also includes flow channels for circulating a sample stream of air over the chip: ethylene is brought to the sensing surface predominately by convection in this sample stream. The sample stream is generated by a built-in sampling pump. The forced circulation of sample air contributes to the attainment of a low detection limit.

Manoukian, Mourad↗

Apparatus for Testing Flat Specimens of Thermal Insulation

An apparatus has been developed to implement an improved method of testing flat-plate specimens of thermal-insulation materials for cryogenic application. The method includes testing under realistic use conditions that could include vacuum and mechanical loading at a pressure up to 70 psi (=0.48 MPa). The apparatus can accommodate a rigid or flexible specimen having thickness up to 1.25 in. (=3.2 cm) and diameters between 6 and 10 in. (about 15.2 and 25.4 cm, respectively). Typical test conditions include boundary temperatures between 77 K and 373 K and vacuum/interstitial gas filling at a pressure between 10(exp -6) torr (=1.3 x 10(exp -4) Pa) and 760 torr (atmospheric pressure =0.1 MPa). The interstitial gas could be N2, He, CO2, or any other suitable gas to which the insulation is expected to be exposed in use. Relative to prior apparatuses and testing methods, this apparatus and the testing method that it implements offer advantages of relative simplicity and ease of use. The basic principle of operation of the apparatus is that of boil-off calorimetry, using liquid nitrogen or any other suitable liquid that boils at a desired temperature below ambient temperature. Comparative rates of flow of heat through the thicknesses of the specimens (heat-leak rates) and apparent-thermal-conductivity values are obtained from tests of specimens. Absolute values of heat-leak rates and apparent thermal conductivities are computed from a combination of (1) the aforementioned comparative values and (2) calibration factors obtained by testing reference specimens of materials that have known thermal-insulation properties. The apparatus includes a full complement of temperature sensors, a vacuum pump and chamber, a monitoring and control system, and tools and fixtures that enable rapid and reliable installation and removal of specimens. A specimen is installed at the bottom of the vacuum chamber, and a cold-mass assembly that includes a tank is lowered into position above and around the specimen (see figure). A spring-based compensating fixture helps to ensure adequate thermal contact with possibly irregular specimen surfaces. For a high-compression test, the springs can be replaced with spacers. A flat circular load cell at the bottom of the chamber measures the compressive load on the specimen. Once the desired compressive-load, temperature, and vacuum/gas-filling conditions are established, testing begins. During a test, all measurements are recorded by use of a portable data-acquisition system and a computer. The total heat-leak rate is measured and calculated as the boil-off flow rate multiplied by the latent heat of vaporization. The parasitic heat leak (to the side of the specimen and to the top and side of the cold-mass tank) is reduced to a small fraction of the total heat leak by use of a combination of multilayer-insulation (MLI) shield rings, reflective film, a fiberglass/epoxy centering ring, and a bulk fill of aerogel beads. This combination eliminates the need for a cryogenic guard chamber used in a typical prior apparatus to reduce the parasitic heat leak.

Fesmire, James E.↗

An Evaluation of Oceanographic Optical Instruments and Deployment Methodologies

The primary objective of the Sea-viewing, Wide Field-of-view Sensor (SeaWiFS) Project is to produce water- leaving radiances with an uncertainty of 5% in clear-water regions and chlorophyll a concentrations within +/- 35% over the range of 0.05-50 mg/cu m. Any global mission, like SeaWiFS, requires validation data be submitted from a wide variety of investigators which places a significant challenge on quantifying the total uncertainty associated with the in situ measurements, because each investigator follows slightly different practices when it comes to implementing all of the steps associated with collecting field data, even those with a prescribed set of protocols. This study uses data from multiple cruises to quantify the uncertainties associated with implementing data collection procedures while utilizing differing in-water optical instruments and deployment methods. A comprehensive approach is undertaken and includes: (1) the use of a portable light source and in-water intercomparisons to monitor the stability of the field radiometers, (2) alternative methods for acquiring reference measurements, and (3) different techniques for making in-water profiles. The only system to meet the 5% radiometric objective of the SeaWiFS Project was a free-fall profiler using (relatively inexpensive) modular components, although a more sophisticated (and comparatively expensive) profiler using integral components was very close and only 1% higher. A relatively inexpensive system deployed with a winch and crane was also close, but the ship shadow contamination problem increased the total uncertainty to approximately 6.5%.

Hooker, Stanford B.↗

Deploying a Route Optimization EFB Application for Commercial Airline Operational Trials

The Traffic Aware Planner (TAP), developed for NASA Langley Research Center to support the Traffic Aware Strategic Aircrew Requests (TASAR) project, is a flight-efficiency software application developed for an Electronic Flight Bag (EFB). Tested in two flight trials and planned for operational testing by two commercial airlines, TAP is a real-time trajectory optimization application that leverages connectivity with onboard avionics and broadband Internet sources to compute and recommend route modifications to flight crews to improve fuel and time performance. The application utilizes a wide range of data, including Automatic Dependent Surveillance Broadcast (ADS-B) traffic, Flight Management System (FMS) guidance and intent, on-board sensors, published winds and weather, and Special Use Airspace (SUA) schedules. This paper discusses the challenges of developing and deploying TAP to various EFB platforms, our solutions to some of these challenges, and lessons learned, to assist commercial software developers and hardware manufacturers in their efforts to implement and extend TAP functionality in their environments. EFB applications (such as TAP) typically access avionics data via an ARINC 834 Simple Text Avionics Protocol (STAP) server hosted by an Aircraft Interface Device (AID) or other installed hardware. While the protocol is standardized, the data sources, content, and transmission rates can vary from aircraft to aircraft. Additionally, the method of communicating with the AID may vary depending on EFB hardware and/or the availability of onboard networking services, such as Ethernet, WIFI, Bluetooth, or other mechanisms. EFBs with portable and installed components can be implemented using a variety of operating systems, and cockpits are increasingly incorporating tablet-based technologies, further expanding the number of platforms the application may need to support. Supporting multiple EFB platforms, AIDs, avionics datasets, and user interfaces presents a challenge for software developers and the management of their code baselines. Maintaining multiple baselines to support all deployment targets can be extremely cumbersome and expensive. Certification also needs to be considered when developing the application. Regardless of whether the software is itself destined to be certified, data requirements in support of the application and user interface elements may introduce certification requirements for EFB manufacturers and the airlines. The example of TAP, the challenges faced, solutions implemented, and lessons learned will give EFB application and hardware developers insight into future potential requirements in deploying TAP or similar flight-deck EFB applications.

Roscoe, David A.↗

SERFE PLSS Component Lessons Learned from ISS

NASA has been developing a new spacesuit, called the Exploration Extravehicular Mobility Unit (xEMU) for over a decade. This spacesuit is under development to support missions to the International Space Station (ISS) and also to the Moon. Improvements in the life and robustness of the Portable Life Support System (PLSS) has been a major objective of these efforts. The Suit Water Membrane Evaporator (SWME) was chosen as the technology to provide cooling to the xEMU and has undergone several iterations of development over this period. An ISS flight experiment centered around the SWME and other thermal control loop (TCL) technologies was developed and tested in an ISS EXpedite PRocessing of Experiments to the Space Station (EXPRESS) rack from November of 2020 to August of 2022. In addition to the SWME, the SWME EXPRESS Rack Flight Experiment (SERFE) contains several technologies from the xEMU project and demonstrated their performance in micro-gravity and over an extended duration. These included two dissimilar water pumps, custom check valves, custom bypass relieve valves, a custom thermal control valve, development pressure and temperature sensors, and the thermal loop controller. This paper presents PLSS component lessons learned after return of the SERFE flight unit in August of 2022. The SERFE team took the flight unit apart and handed hardware components over to hardware owners to see how parts of the TCL managed after almost 2 years on the ISS and 25 simulated EVAs (Exploration Extravehicular Activity) on orbit. The team performed inspection, testing, and analysis and provided lessons learned on PLSS components for NASA’s prototype spacesuit. This analysis included how well SWME maintained its heat rejection capability, as well as looked at the robustness of the other TCL hardware.

SERFE↗

SERFE PLSS Component Lessons Learned from ISS

NASA has been developing a new spacesuit, called the Exploration Extravehicular Mobility Unit (xEMU) for over a decade. This spacesuit is under development to support missions to the International Space Station (ISS) and also to the Moon. Improvements in the life and robustness of the Portable Life Support System (PLSS) has been a major objective of these efforts. The Suit Water Membrane Evaporator (SWME) was chosen as the technology to provide cooling to the xEMU and has undergone several iterations of development over this period. An ISS flight experiment centered around the SWME and other thermal control loop (TCL) technologies was developed and tested in an ISS EXpedite PRocessing of Experiments to the Space Station (EXPRESS) rack from November of 2020 to August of 2022. In addition to the SWME, the SWME EXPRESS Rack Flight Experiment (SERFE) contains several technologies from the xEMU project and demonstrated their performance in micro-gravity and over an extended duration. These included two dissimilar water pumps, custom check valves, custom bypass relieve valves, a custom thermal control valve, development pressure and temperature sensors, and the thermal loop controller. This paper presents PLSS component lessons learned after return of the SERFE flight unit in August of 2022. The SERFE team took the flight unit apart and handed hardware components over to hardware owners to see how parts of the TCL managed after almost 2 years on the ISS and 25 simulated EVAs (Exploration Extravehicular Activity) on orbit. The team performed inspection, testing, and analysis and provided lessons learned on PLSS components for NASA’s prototype spacesuit. This analysis included how well SWME maintained its heat rejection capability, as well as looked at the robustness of the other TCL hardware.

SERFE↗

Thermoelectric microdevice fabricated by a MEMS-like electrochemical process

Microelectromechanical systems (MEMS) are the basis of many rapidly growing technologies, because they combine miniature sensors and actuators with communications and electronics at low cost. Commercial MEMS fabrication processes are limited to silicon-based materials or two-dimensional structures. Here we show an inexpensive, electrochemical technique to build MEMS-like structures that contain several different metals and semiconductors with three-dimensional bridging structures. We demonstrate this technique by building a working microthermoelectric device. Using repeated exposure and development of multiple photoresist layers, several different metals and thermoelectric materials are fabricated in a three-dimensional structure. A device containing 126 n-type and p-type (Bi, Sb)2Te3 thermoelectric elements, 20 microm tall and 60 microm in diameter with bridging metal interconnects, was fabricated and cooling demonstrated. Such a device should be of technological importance for precise thermal control when operating as a cooler, and for portable power when operating as a micro power generator.

Evaluation Studies↗

SERFE Thermal Performance Results

NASA has been developing a new spacesuit, called the Exploration Extravehicular Mobility Unit (xEMU) for over a decade. This spacesuit is underdevelopment to support missions to the International Space Station (ISS) and also to the Moon. Improvements in the life and robustness of the Portable Life Support System (PLSS) has been a major objective of these efforts. The Suit Water Membrance Evaporator (SWME) was chosen as the technology to provide cooling to the xEMU and has undergone several iterations of development over this period. An ISS flight experiment centered around the SWME and other thermal loop technologies was developed and has been under test in an ISS EXpedite PRocessing of Experiments to the Space Station (EXPRESS) rack since November of 2020. In addition to the SWME, The SWME EXPRESS Rack Flight Experiment (SERFE) contains several technology demonstrations from the xEMU project and has been demonstrating their performance in micro-gravity and over an extended duration. In addition to the SWME, these include two dissimilar water pumps, custom check valves, custom bypass relieve valves, a custom thermal control valve, development pressure and temperature sensors, and the Thermal Loop Controller. This paper presents thermal and fluids testing results of the system as a whole and of key components.

SERFE↗

Development and Application of a Portable Health Algorithms Test System

This paper describes the development and initial demonstration of a Portable Health Algorithms Test (PHALT) System that is being developed by researchers at the NASA Glenn Research Center (GRC). The PHALT System was conceived as a means of evolving the maturity and credibility of algorithms developed to assess the health of aerospace systems. Comprising an integrated hardware-software environment, the PHALT System allows systems health management algorithms to be developed in a graphical programming environment; to be tested and refined using system simulation or test data playback; and finally, to be evaluated in a real-time hardware-in-the-loop mode with a live test article. In this paper, PHALT System development is described through the presentation of a functional architecture, followed by the selection and integration of hardware and software. Also described is an initial real-time hardware-in-the-loop demonstration that used sensor data qualification algorithms to diagnose and isolate simulated sensor failures in a prototype Power Distribution Unit test-bed. Success of the initial demonstration is highlighted by the correct detection of all sensor failures and the absence of any real-time constraint violations.

Melcher, Kevin J.↗

Design of An Improved Miniature Ion Neutral Mass Spectrometer for NASA Applications

The ion optics of NASA's Ion Neutral Mass Spectrometer (INMS) sensor was simulated with three dimensional models of the open source, the quadrupole deflector, the exit lens system and the quadrupole mass analyzer to design more compact models with lower weight. Comparison of calculated transmission with experimental results shows good agreement. Transmission analyses with varying geometrical parameters and voltages throw light on possible ways of reducing the size of the sensor. Trajectories of ions of mass 1-99 amu were simulated to analyze and optimize transmission. Analysis of open source transmission with varying angle of attack shows that the angular acceptance can be considerably increased by programming the voltages on the ion trap/ collimator. Analysis of transmission sensitivity to voltages and misalignments of the quadrupole deflector rods indicate that increased transmission is possible with a geometrically asymmetrical deflector and a deflector can be designed with much lower sensitivities of transmission. Bringing the disks closer together can decrease the size of the quadrupole deflector and also increase transmission. The exit lens system can be redesigned to be smaller by eliminating at least one electrode entirely without loss of transmission. Ceramic materials were investigated to find suitable candidates for use in the construction of lighter weight mass spectrometer. A high-sensitivity, high-resolution portable gas chromatograph mass spectrometer with a mass range of 2-700 amu has been built and will be commercialized in Phase 3.

Swaminathan, Viji K.↗

JOVE

The focus of our JOVE research has been to develop a field instrument that provides high quality data for atmospheric corrections and in-flight calibration of airborne and satellite remote sensing imaging systems. The instrument package is known as the Portable Ground-based Atmospheric Monitoring System or PGAMS. PGAMS collects a comprehensive set of spectroscopic/radiometric observations that describe the optical properties of the atmosphere and reflectance of a target area on the earth's surface at the time of the aircraft or satellite overpass. To date, the PGAMS instrument system and control software has been completed and used for data collection in several NASA field experiments across the continental US and Puerto Rico. Where do you see your JOVE research going after the initial JOVE Funding Expires? Our JOVE initiated research will continue to be very active in supporting validation and calibration activities in remote sensing involving NASA, DOE, DOD, NSF, and possibly commercial supported programs. Future effort will focus on projects related to NASA's Mission to Planet Earth. This will include field work using PGAMS and data analysis that evaluates sensor calibration and atmospheric effects in images recorded by ASTER, MODIS, and MISR instruments aboard the AM-1 platform.

Schiller, Stephen↗

BEAST: Expanding Sustainable Data Infrastructure for High-Enthalpy Facilities

Reproducible, data-driven thermal protection system (TPS) research requires that experimental records from high-enthalpy testing be consistently structured, traceable, and accessible across campaigns and institutions. In practice, however, arcjet and plasma facilities data remain largely fragmented: raw diagnostics are stored in ad hoc formats, material sample histories are disconnected from test conditions, and metadata standards are absent, precluding systematic cross-campaign analysis and long-term reuse. BEAST (Backend for Experiment Analysis, Storage, and Traceability) is an open-source, web-based platform that addresses these limitations by providing a unified, queryable infrastructure for high-enthalpy ground-test data [1]. First presented at the 15th Ablation Workshop [2], BEAST has since undergone significant development. The platform ingests and structures multi-channel time-series diagnostics, facility configurations, and material property records within a common provenance model, ensuring end-to-end traceability from raw sensor acquisition to reduced experimental quantities. A versioned material library links specimen identity and processing history to the specific runs in which each sample was tested. An integrated modeling workbench enables training and evaluation of regression models directly on archived experimental data, supporting condition interpolation and the construction of empirical material response databases. Beyond its original deployment at NASA Ames Research Center, BEAST has been designed to be facility-agnostic, with ongoing efforts to extend its adoption to other facilities. Its modular architecture accommodates heterogeneous diagnostic setups and facility types, and its future open-source distribution allows institutions to build on a common data standard rather than maintaining isolated, bespoke solutions. BEAST is further integrated within a broader ecosystem of companion tools: arcjetCV [3] extracts recession rates and shock standoff distances from high-speed video using computer vision, and miniSTARscan [4] provides sub-minute, portable photogrammetric surface reconstruction of test articles before and after exposure. All tools share a common data schema, enabling seamless ingestion of surface geometry, imagery, and time-series data into a single, coherent experimental record.

Database↗

BEAST: Expanding Sustainable Data Infrastructure for High-Enthalpy Facilities

Reproducible, data-driven thermal protection system (TPS) research requires that experimental records from high-enthalpy testing be consistently structured, traceable, and accessible across campaigns and institutions. In practice, however, arcjet and plasma facilities data remain largely fragmented: raw diagnostics are stored in ad hoc formats, material sample histories are disconnected from test conditions, and metadata standards are absent, precluding systematic cross-campaign analysis and long-term reuse. BEAST (Backend for Experiment Analysis, Storage, and Traceability) is an open-source, web-based platform that addresses these limitations by providing a unified, queryable infrastructure for high-enthalpy ground-test data [1]. First presented at the 15th Ablation Workshop [2], BEAST has since undergone significant development. The platform ingests and structures multi-channel time-series diagnostics, facility configurations, and material property records within a common provenance model, ensuring end-to-end traceability from raw sensor acquisition to reduced experimental quantities. A versioned material library links specimen identity and processing history to the specific runs in which each sample was tested. An integrated modeling workbench enables training and evaluation of regression models directly on archived experimental data, supporting condition interpolation and the construction of empirical material response databases. Beyond its original deployment at NASA Ames Research Center, BEAST has been designed to be facility-agnostic, with ongoing efforts to extend its adoption to other facilities. Its modular architecture accommodates heterogeneous diagnostic setups and facility types, and its future open-source distribution allows institutions to build on a common data standard rather than maintaining isolated, bespoke solutions. BEAST is further integrated within a broader ecosystem of companion tools: arcjetCV [3] extracts recession rates and shock standoff distances from high-speed video using computer vision, and miniSTARscan [4] provides sub-minute, portable photogrammetric surface reconstruction of test articles before and after exposure. All tools share a common data schema, enabling seamless ingestion of surface geometry, imagery, and time-series data into a single, coherent experimental record.

Database↗

SeaWiFS Postlaunch Technical Report Series: The Fifth Sea-WiFS Intercalibration Round-Robin Experiment (SIRREX-5), July 1996 - Volume 7

This report documents the fifth Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Intercalibration Round-Robin Experiment (SIRREX-5), which was held at the National Institute of Standards and Technology (NIST) on 23-30 July 1996. The agenda for SIRREX-5 was established based on recommendations made during SIRREX-4. For the first time in a SIRREX activity, instrument intercomparisons were performed at field sites, which were near NIST. The goals of SIRREX-5 were to continue the emphasis on training and the implementation of standard measurement practices, investigate the calibration methods and measurement chains in use by the oceanographic community, provide opportunities for discussion, and intercompare selected instruments. As at SIRREX-4, the day was divided between morning lectures and afternoon laboratory exercises. A set of core laboratory sessions were performed: 1) in-water radiant flux measurements; 2) in-air radiant flux measurements; 3) spectral radiance responsivity measurements using the plaque method; 4) device calibration or stability monitoring with portable field sources; and 5) various ancillary exercises designed to illustrate radiometric concepts. Before, during, and after SIRREX-5, NIST calibrated the SIRREX-5 participating radiometers for radiance and irradiance responsivity. The Facility for Automated Spectroradiometric Calibrations (FASCAL) was scheduled for spectral irradiance calibrations for standard lamps during SIRREX-5. Three lamps from the SeaWiFS community were submitted and two were calibrated.

Hooker, Stanford B.↗

Water Pump Development for the EVA PLSS

This paper describes the effort by the Texas Engineering Experiment Station (TEES) and Honeywell for NASA to design, fabricate, and test a preflight prototype pump for use in the Extravehicular activity (EVA) portable life support subsystem (PLSS). Major design decisions were driven by the need to reduce the pump s mass, power, and volume compared to the existing PLSS pump. In addition, the pump will accommodate a much wider range of abnormal conditions than the existing pump, including vapor/gas bubbles and increased pressure drop when employed to cool two suits simultaneously. A positive displacement, external gear type pump was selected because it offers the most compact and highest efficiency solution over the required range of flow rates and pressure drops. An additional benefit of selecting a gear pump design is that it is self priming and capable of ingesting noncondensable gas without becoming "air locked." The chosen pump design consists of a 28 V DC, brushless, sealless, permanent magnet motor driven, external gear pump that utilizes a Honeywell development that eliminates the need for magnetic coupling. Although the planned flight unit will use a sensorless motor with custom designed controller, the preflight prototype to be provided for this project incorporates Hall effect sensors, allowing an interface with a readily available commercial motor controller. This design approach reduced the cost of this project and gives NASA more flexibility in future PLSS laboratory testing. The pump design was based on existing Honeywell designs, but incorporated features specifically for the PLSS application, including all of the key features of the flight pump. Testing at TEES will simulate the vacuum environment in which the flight pump will operate. Testing will verify that the pump meets design requirements for range of flow rates, pressure rise, power consumption, working fluid temperature, operating time, and restart capability. Pump testing is currently scheduled for March, 2009, after which the pump will be delivered to NASA for further testing.

Schuller, Michael↗

Custom Unit Pump Design and Testing for the EVA PLSS

This paper describes the effort by the Texas Engineering Experiment Station (TEES) and Honeywell for NASA to design and test a pre-flight prototype pump for use in the Extra-vehicular activity (EVA) portable life support subsystem (PLSS). Major design decisions were driven by the need to reduce the pump s mass, power, and volume compared to the existing PLSS pump. In addition, the pump must accommodate a much wider range of abnormal conditions than the existing pump, including vapor/gas bubbles and increased pressure drop when employed to cool two suits simultaneously. A positive displacement, external gear type pump was selected because it offers the most compact and highest efficiency solution over the required range of flow rates and pressure drops. An additional benefit of selecting a gear pump design is that it is self priming and capable of ingesting non-condensable gas without becoming air locked. The chosen pump design consists of a 28 V DC, brushless, sealless, permanent magnet motor driven, external gear pump that utilizes a Honeywell development that eliminates the need for magnetic coupling. Although the planned flight unit will use a sensorless motor with custom designed controller, the pre-flight prototype to be provided for this project incorporates Hall effect sensors, allowing an interface with a readily available commercial motor controller. This design approach reduced the cost of this project and gives NASA more flexibility in future PLSS laboratory testing. The pump design was based on existing Honeywell designs, but incorporated features specifically for the PLSS application, including all of the key features of the flight pump. Testing at TEES verified that the pump meets the design requirements for range of flow rates, pressure drop, power consumption, working fluid temperature, operating time, gas ingestion , and restart capability under both ambient and vacuum conditions. The pump operated between 40 and 240 lbm/hr flowrate, 35 to 100 F pump temperature range, and 5 to 10 psid pressure rise. Power consumption of the pump controller at the nominal operating point in both ambient and vacuum conditions was 9.5 W, which was less than the 12 W predicted. Gas ingestion capabilities were tested by injecting 100 cc of air into the fluid line; the pump operated normally throughout this test. The test results contained a number of anomalies, specifically power increases and a few flow stoppages, that prompted TEES and Honeywell to disassemble and inspect the pump. Inspection indicated contamination in the pump and fit issues may have played roles in the observed anomalies. Testing following reassembly indicated that the performance of the pump 1) matched both the predicted performance values, 2) the performance values measured prior to disassembly, and 3) was free of the anomalies noted in the pre-disassembly testing.

Schuller, Michael↗