At least 235 records · Page 13

Assessing DER Network Cybersecurity Defences in a Power-Communication Co-Simulation Environment

Increasing penetrations of interoperable distributed energy resources (DER) in the electric power system are expanding the power system attack surface. Maloperation or malicious control of DER equipment can now cause substantial disturbances to grid operations. Fortunately, many options exist to defend and limit adversary impact on these newly-created DER communication networks, which typically traverse the public internet. However, implementing these security features will increase communication latency, thereby adversely impacting real-time DER grid support service effectiveness. In this work, a collection of software tools called SCEPTRE were used to create a co-simulation environment where SunSpec-compliant PV inverters were deployed as virtual machines and interconnected to simulated communication network equipment. Network segmentation, encryption, and moving target defence security features were deployed on the control network to evaluate their influence on cybersecurity metrics and power system performance. The results indicated that adding these security features did not impact DER-based grid control systems but improved the cybersecurity posture of the network when implemented appropriately.

97 MATHEMATICS AND COMPUTING↗

Renewable energy integration and system operation challenge: control and optimization of millions of devices

The electric power infrastructure, originally designed and built on large-scale power plants, is evolving into a more resilient power generation and delivery system in which millions of smaller units of distributed energy generation resources units will be installed in sub-transmission and distribution networks. In order to control, manage and optimize the future grid, a hierarchical design is presented in this chapter which enables the distributed control on grid edge while inheriting the existing centralized control structure. This layered design of large-scale power system operation and control uses the following principle: reactive power control is treated as a primary control for voltage stability, and the real power control is primarily a grid-level control but can also be a supplementary control for voltage support in the case of insufficient reactive power control capacity. For the purpose of active control and operation at the distribution level, a recursive power network model is derived from nodal injection and branch power flow models. Based on the model, the proposed algorithms of hierarchical control, grid-edge inference and dynamic hosting allowance are developed and presented for multi-level controlled operation. And, a co-simulation architecture of integrated T&D system is presented to validate and demonstrate the feasibility and scalability of proposed algorithms.

Xu, Ying↗

A New Type of Weak Grid IBR Oscillations

This letter presents the discovery of a new type oscillations associated with inverter-based resources (IBRs) in weak grids. While typical weak grid oscillations become worse when the grid strength decreases and the power exporting level increases, this new type of oscillations appear when the grid becomes weaker and the power exporting level decreases. Electromagnetic transient (EMT) simulation results are presented, along with eigenvalue loci for a varying power. The notable signatures of such oscillations are also remarked. In further analysis, a feedback system consisting of two blocks is derived with one block associated with the phase-locked-loop (PLL) and the other associated with the rest of the system. Here, this feedback system quantitatively demonstrates why insufficient damping in the PLL may be an issue for stability. Open-loop analysis shows that a larger phase lag in angle tracking in the low-frequency range due to high power exporting level at the weak grid condition is beneficial to the open-loop poles introduced by the PLL. And this is the reason why such oscillations may appear when power is ramping down.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Performance Computing Based EMT Simulation of Large PV or Hybrid PV Plants

Faults in the transmission grid have led to reduced power generation from power electronics resources that are typically not connected to the faulted transmission line. In many of the cases, partial loss of power is observed within the power electronics resources like large photovoltaic (PV) power plants. This phenomena is not captured in existing simulation models and/or simulators. High-fidelity switched system electromagnetic transient (EMT) dynamic models of PV power plants can improve the fidelity of models available for accurate analysis of the impact on PV plants during simulation of faults. However, these models are extremely computationally expensive and take a long time to simulate. Long simulation times limit the ability to use these models as larger regions are studied in EMT simulations with more power electronics resources. In this paper, numerical simulation algorithms are combined with high-performance computing techniques and applied to the high-fidelity switched system EMT model of PV plants. Using these techniques, a speed-up of up to 58x is obtained, while preserving the accuracy of the simulation at greater than 98%.

Debnath, Suman↗

Deadband Voltage Control and Power Buffering for Extreme Fast Charging Station

Voltage fluctuation is one of the most common challenges that electric vehicle charging station (EVCS) may introduce to the power grid. Local reactive power compensation (Q-compensation) capability of bi-directional electric vehicle (EV) chargers can mitigate the steady-state voltage violations caused by the EV charging itself or changes in the neighboring loads. Power buffering, using energy storage system (ESS), can be utilized to address the voltage transients (sags and swells) as a result of EV charging at the EVCS. To address PI controller’s ‘hunting’ issue, this paper proposes a Q-sign triggered deadband voltage control (V-control) method at the point of common coupling (PCC). In addition, to ensure the ramp rate of EV charging is within the allowable limits set forth by the grid code, a ramp rate control is proposed that uses the ESS as a ‘power buffer’. Lastly, different from most reported work in the literature where no explicit limit of the power electronic converters (PECs) is considered, this work considers a reasonable apparent power capacity limit of the PECs when achieving the V-control. This limit also affects the amount of active power that can be obtained from the grid, and subsequently may require ESS to function as ‘load sharing’ device to provide supplemental active power to satisfy EV load. A case study simulated in MATLAB (interfaced with PLECS) is presented to demonstrate the effectiveness of the proposed approaches for EVCS operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Geothermal-integrated thermally anisotropic building envelope for energy and peak-demand reduction

Buildings consume large amounts of energy for heating and cooling, while peak electricity demand places significant stress on the power grid. This paper presents a reduced-order co-simulation framework and load-oriented supervisory control strategy for a geothermal-integrated thermally anisotropic building envelope with a ground loop (TABE+GL). In TABE+GL, a hydronic loop embedded in the building envelope is directly coupled with a geothermal ground loop, allowing for bidirectional heat exchange between the envelope, the ground, and the indoor environment. A hybrid co-simulation framework was established by coupling a reduced-order resistor–capacitor (RC) thermal network model with EnergyPlus augmented with GHEDesigner modules. The RC model generated feasible heat flux options under three operating modes, and EnergyPlus predicted sensible loads, energy use, and pump energy demand. At each simulation step, a supervisory control algorithm selected the optimal loop configuration and duty factor that maximizes useful TABE geothermal utilization without exceeding the predicted sensible load, thereby avoiding overheating or cooling. Case studies were conducted for Los Angeles, California, Charleston, South Carolina, and Denver, Colorado. Results showed that the proposed framework reduced HVAC electricity consumption by 43%–67%, natural gas use for space heating by 11%–38%, and peak electricity demand by 43%–88%. These results highlight the potential of combining reduced-order envelope modeling, direct geothermal coupling, and load-oriented supervisory control to improve whole building energy performance and reduce peak demand across diverse weather conditions.

Howard, Daniel [Southern Adventist University]↗

Enhancing EV Charging Station Resilience with Multifunctional Converter Leg Integration

In this paper, a multifunctional converter leg is integrated into an EV charger’s power circuit to enhance EV charging station resilience under power electronics converter device faults and grid outages. In the event of a device fault, it substitutes the failed converter leg, maintaining operation. During a grid outage, it assists the system as a fourth leg to the front-end converter, enabling grid-forming capability to supply power to the charging station critical loads while allowing limited power vehicle charging. The proposed approach’s effectiveness under both front-end power converter device faults and grid outage scenarios are validated through simulation and controller hardware-in-the-loop results.

Pereira Pinto, Joao [ORNL]↗

NOODLES Grid [SWR-25-93]

NOODLES Grid is a real-time visualization server for power system simulation data. It loads precomputed datasets, builds optimized instance renderings, and streams live interactive scenes to connected clients. It is built for high scalability, flexible visualization, and fast interaction. NOODLES is a cross-platform/device/tool protocol for collaborative visualization. NOODLES was Developed at the National Renewable Energy Laboratory (NREL) as a capability of the Insight Center https://www.nrel.gov/computational-science/insight-center.html

Brunhart-Lupo, Nicholas [National Renewable Energy↗

Combinatorial Algorithms in Scientific Computing

We provide the final report for this grant, detailing the publications, software produced, students trained who have joined the DOE workforce, and the impact our work has had on computational mathematics and related disciplines.

97 MATHEMATICS AND COMPUTING↗

FY26 Progress on Demonstration of a Multiphysics Steady State Capability for Modeling Core Radial Expansion in SFRs

Under the U.S. Department of Energy Office of Nuclear Energy Advanced Modeling and Simulation (NEAMS) Program, an integrated multiphysics approach is being developed to model the core bowing phenomena important to liquid metal-cooled fast reactors. Core bowing is an important passive safety mechanism in liquid metal-cooled fast reactors and involves multiphysics effects including radiation transport, fluid flow, heat transfer, and mechanical response to temperature and flux gradients. This report summarizes recent progress on developing a multiphysics, MOOSE-based workflow to predict core bowing and associated reactivity feedback. Significant new capabilities in the reactor physics code Griffin - sodium backfill and pin power reconstruction for deformed geometries - were applied in this effort. This year’s work included verification, code comparisons, sensitivity studies, and coupled demonstrations that advance the state of MOOSE-based core bowing workflow. Griffin’s sodium backfill capability was verified by demonstrating that its automated treatment of geometry expansion and material-density updates reproduces manual calculations exactly, confirming solid mass conservation and proper coolant backfilling in expanded geometries. Reconstructed pin powers were compared for Griffin’s ductheterogeneous and ring-heterogeneous treatments in single-, seven-, and nineteen-assembly cases, with best agreement observed in lower-leakage configurations and the duct-heterogeneous approach offering substantially lower computational cost. Thermal-hydraulic sensitivity sensitivities showed that MOOSE SCM, SAM, and CFD are expected to produce similar deformation predictions despite variances in their temperature predictions, and that explicit treatment of inter-assembly flow becomes increasingly important as gap flow rate increases. Finally, coupled demonstrations on small multi-assembly configurations using Griffin, MOOSE Solid Mechanics, MOOSE SCM, and Heat Conduction produced physically consistent reactivity feedback from thermal expansion and bowing. The coupled demonstrations simulated grid plate expansion as well as resultant core bowing at full power conditions. Simplifications were made in current workflow, namely the assumption of instantaneous full power conditions following hot zero power, and pre-expanding the Griffin geometry axially due to lack of an axial fuel pin expansion model and temperature feedback to Griffin.

Wozniak, Nicholas↗

Electromagnetic Transient Simulation of Large-Scale Inverter-Based Resources With High-Granularity

The power grid is undergoing a significant transformation with the rapid increase in inverter-based resources (IBRs), including large-scale photovoltaic (PV) plants. Ensuring reliable and resilient grid operation in this new paradigm necessitates high-granularity electromagnetic transient (EMT) modeling that accurately captures the behavior of individual inverters and their interactions within IBR plants. Central to this approach is the detailed representation of both the IBR plant’s collector system and the dynamics of individual inverters. To achieve this, a high-granularity EMT model of a large-scale PV plant has been developed using advanced simulation algorithms, including matrix splitting and the Schur complement. These proposed techniques significantly enhance simulation speed, numerical stability, and accuracy while improving the modularity and efficiency of the collector system’s representation. The effectiveness of the proposed methods is validated through simulations of a representative large-scale PV plant consisting of 125 individual PV inverters, 25 IBR unit transformers, and a 52-bus collector system.

Choi, Jongchan [Oak Ridge National Laboratory (ORN↗

Digital Twin + AI: Control Room of the Future

A digital twin enhances power grid control room operations by providing real-time monitoring, predictive insights, simulation capabilities, remote control, training opportunities, data integration, and decision support. This technology empowers control room operators to effectively manage the grid, optimize performance, and ensure reliable and efficient energy distribution.

control room of the future↗

DeepGrid: Robust Deep Reinforcement Learning-based Contingency Management

Increasing uncertainty raised by the integration of renewable energy resources requires an enormous number of simulations to be carried out for the security assessment of the power grid. However, it is challenging to assess the steady-state and dynamic security indices for different system contingency events by doing an exhaustive analysis in real-time due to the computational and communication constraints. One promising solution is using data-driven techniques along with the system models to train an intelligent contingency management framework to better handle the contingencies in real-time. Nevertheless, implementing a data-driven technique to obtain the best remedial actions necessitates to account for the effect of the measurement noise on the performance of the contingency management. To tackle these challenges, we leverage a robust deep reinforcement learning (DRL) algorithm called Double Deep Q-Network (DDQN) to design a recommender system capable of prescribing optimal control actions with the help of the real-time digital simulator (RTDS). The use of RTDS system in combination with the advanced DRL algorithm allows to explore a wide variety of system contingencies in order to derive better remedial actions. The performance of the proposed algorithm is evaluated in IEEE 9-bus system under different loading conditions, and different network configurations in presence of noisy measurements.

Ghasemkhani, Amir↗

Cybersecurity Assessment in DER-rich Distribution Operations: Criticality Levels and Impact Analysis

The integration of distributed energy resources (DERs) in distribution networks has become a pivotal strategy for achieving decarbonization, enhancing grid resilience, and optimizing grid efficiency. Remote monitoring and control op- erations of such resources rely on a network of sensors and communication infrastructure, exposing the system to potential cyber threats. Therefore, as the deployment of DERs increases, ensuring secure monitoring and control becomes an imperative challenge. This paper utilizes real-time feeder models, which are instrumental in developing cybersecurity testbeds tailored for hardware-in-loop (HIL) systems. These models enable users to simulate cyber attacks in a real-world environment and analyze the power distribution operations during vulnerabilities. Furthermore, we discuss several practical sets of grid parameters to identify critical levels of DERs and evaluate various scenarios that simulate cyber threats on sensitive DERs. The modified IEEE 123-bus model is used as the test case for demonstrating the proposed scenarios. The findings from this study provide valuable insights into the vulnerabilities and potential consequences of cyber attacks on DERs, allowing for better mitigation strategies and improved cyber resilience in future distribution networks.

Maharjan, Manisha↗

Dynamic Model of Back-to-Back Converter for System Level Phasor Simulation

The power system is expected to evolve rapidly with increasing deployment of power electronic interface and conditioning systems, microgrids, and hybrid AC/DC grids. Among power electronic systems, back-to-back (BTB) converters can be a powerful interface to integrate microgrids and networked microgrids. However, in system level dynamic simulations for synchronous machine dominated system with BTB converters, a detailed electromagnetic sinusoidal models is not warranted as these simulations are focused on electromechanical transients. This paper focus on developing a simple phasor model for back- to-back converters that can be easily integrated into powerflow solvers to facilitate large-scale power system simulations. The model is implemented using C++ language and integrated into GridLAB-D software as a potential new capability. The GridLAB-D phasor domain model is validated against the electromagnetic transient (EMT) simulation of the detailed switching model. Simulation results show that the phasor model successfully captures the dominant dynamics of the converters.

Mahmood, Hisham↗

Robust Adaptive Control for Large-scale Inverter-based Resources with Partial and Complete Loss of Inverters

This article proposes an approach to address the current and the aggregated active power control challenge for large-scale inverter-based resources subjected to partially or completely loss of inverters and grid voltage variations. To address this problem, a distributed active power mechanism is proposed which generates desired inverters current. Then an adaptive mechanism distributes the voltage control input automatically between inverters in response to the partial or complete loss of inverters. An L2-gain-based controller is designed for each inverter to track the desired current and rejects the grid voltage disturbance. Here, simulation results show a significant robust tracking for collective active power and current.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reliable Protection for an Inverter-Based Resources Dominant Grid: Technology Development and Field Demonstration

The project aimed to address the challenges posed by the rapid growth of inverter-based resources (IBR) such as solar, wind, and battery storage, which have fundamentally changed fault behavior, system strength, and protection performance in bulk power systems. Traditional protection schemes, designed for synchronous generator-dominated grids, are inadequate under high IBR penetration. Overall, the project materially advances protection modeling and simulation capabilities needed to maintain reliable grid protection under high IBR penetration. The results build utility confidence in operating power systems safely and reliably across a wide range of generation mixes, supporting grid modernization goals.

24 POWER TRANSMISSION AND DISTRIBUTION↗