At least 235 records · Page 13

Tamper performance for confined laser drive applications

The shock imparted by a laser beam striking a metal surface can be increased by the presence of an optically transparent tamper plate bonded to the surface. We explore the shock produced in an aluminum slab, for a selection of tamper materials and drive conditions. The experiments are conducted with a single-pulse laser of maximum fluence up to 100 J/cm 2 . The pressure and impulse are measured by photon doppler velocimetry, while plasma imaging is used to provide evidence of nonlinear tamper absorption. We demonstrate a pressure enhancement of 50x using simple commercially available optics. We compare results from hard dielectric glasses such as fused silica to soft plastics such as teflon tape. We discuss the mechanism of pressure saturation observed at high pulse fluence, along with some implications regarding applications. Below saturation, overall dependencies on pulse intensity and material parameters such as mechanical impedances are shown to correlate with a model by Fabbro et al .

36 MATERIALS SCIENCE↗

Heat Transfer Experiments of a 1st Stage Blade Cascade for Supercritical CO2 Oxy-Combustion Turbine Application

The results of internally cooled 1st stage blade (S1B) cascade testing in a supercritical CO2 environment is presented. The turbine blade design has been previously established for the end application of an oxy-combustion turbine operating in the Allam-Fetvedt cycle with turbine inlet conditions of 305 bar and 1150°C. The internally cooled blade features leading edge (LE) region impingement cooling, mid-section ribbed serpentine passages, and a pin-finned trailing edge (TE) region before cooling ejection holes. The geometry for the tested blade cascade has a cooled central blade with un-cooled blades on either side to match flowpath areas of the actual turbine. The flowpath reuses internal components previously employed for mid-section region ribbed serpentine passage experiments that established Nusselt number enhancement ratios over a range of Reynolds numbers from 100,000-400,000. New components include flow conditioning plates upstream and downstream of the blade cascade to adequately represent the flow field and blade external heat transfer coefficient profiles for the actual turbine. The cooled central blade utilizes uniform crystal temperature sensors (UCTS) with six sensors each on the blade pressure and suction surfaces distributed radially and from LE to TE. The post-processed UCTS quantified the maximum wall temperature seen at each installed sensor location. The test procedure consisted of establishing supercritical CO2 cooling flow temperature and flow rate and maintaining it throughout the test. The flow rate aims to match that for the actual in-service turbine blade design and is maintained through an orifice restriction to keep the pressure differential between internal cooling flow and external hot flow nearly constant. For the sCO2 flow path external to the blade, temperatures were ramped throughout the test via control of the test loop’s natural gas burner heater. The maximum temperature seen was 468°C and held constant for a duration of 10 minutes at which the blade metal temperature was predicted to be at its maximum before ramping down. For the turbine blade design for service inlet conditions, external flow path computational fluid dynamics (CFD) results and an internal cooling 1-D thermal and hydraulic flow network model using experimentally validated correlations served as thermal finite element (FE) boundary conditions to predict blade metal temperatures. These predicted temperatures were subsequently utilized in a structural FE model to predict blade life ratings dictated by Haynes 282 creep strength data, having a strong dependence on temperature. The boundary conditions experienced during testing are used in the same workflow and compared to the experimental results, with the goal of validating the analysis methodology and providing insight on the uncertainty in local metal temperature predictions.

20 FOSSIL-FUELED POWER PLANTS↗

Design and Testing of a Prototype Eddy Current Actuated Valve for the ITER Shattered Pellet Injection System

Reliably mitigating disruptions is essential for ITER to meet its long-term operational research plan without damage to the in-vessel components. Currently, the shattered pellet injection (SPI) technique is the most effective radiator of thermal energy and has been chosen for the baseline disruption mitigation system (DMS) for ITER. The SPI process uses cryogenic temperatures to desublimate material into the barrel of a pipe gun forming a solid cylindrical pellet. Pellets for ITER will initially be hydrogen and hydrogen-neon mixtures. Once formed, pellets are dislodged and accelerated using high-pressure gas (40-60 bar) delivered by a fast-opening valve. The solenoid valves currently used for SPI experiments will not operate in an ITER environment due to the large background magnetic field. An ITER prototype fast-opening valve, called a flyer plate valve (FPV), has been designed and has undergone a wide range of testing. The FPV operates by pulsing current through a pancake coil that is closely coupled with a ``flyer plate.'' The flyer plate is an aluminum plate in which eddy currents are generated creating a repulsive force from the pancake coil. The force generated in the flyer plate rapidly lifts the valve tip off the seat and delivers a pulse of gas to the rear of the pellet, breaking it free from the barrel and accelerating the pellet downstream to its intended target. The design of the valve has been iterated on over the lifetime of this project, as the DMS for ITER shifted from massive gas injection (MGI) to SPI. The most recent design has been tested, and operational ranges have been mapped. The valve must survive 3000+ cycles in an ITER-like magnetic field. The principal functional requirement of this valve is to reliably dislodge and accelerate hydrogen (or H-Ne mixture) pellets into ITER. The valve was mated with an ITER SPI test stand and has been shown to be capable of launching pellets reliably. The valve and power supply design will be discussed in this article, along with the various testing setups used to determine the feasibility of this valve for use on ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A709 Qualification Plan Update and Mechanical Properties Data Assessment

This report provides a summary of the development effort for the qualification of Alloy 709, an advanced austenitic stainless steel, in the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, Section III, Division 5, High Temperature Reactors. It provides an assessment of the mechanical properties data generated to date from the tensile, creep, fatigue and creep-fatigue tests of the precipitation-treated Alloy 709 from two commercial heats in plate product form. It was concluded that the mechanical properties of Alloy 709 with the precipitation treatment continued to outperform those of Type 316 stainless steel. This affirms the recommendation to Code qualification this alloy as a replacement for Type 316 stainless steel to support the objective of reducing the construction and operating costs to incentivize advanced reactor deployment. The data also demonstrated that the precipitation treatment is effective in enhancing the creep-fatigue resistance of Alloy 709 while maintaining a significant creep strength advantage over Type 316 stainless steel. This report also provides an update to the test conditions for the creep, fatigue and creep-fatigue test matrices in order to cover the Code Case data package more effectively. Finally, it is recommended to continue the Alloy 709 Code Case Testing Program to develop the data package needed for the determination of the material-specific design parameters for inclusion in the Alloy 709 Code Case.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hexagonal Distributed Embedded Energy Converters (HexDEECs)

Distributed Embedded Energy Converter Technologies (DEEC-Tec) is a new domain for marine renewable energy research that utilizes a conglomeration of small distributed embedded energy converters (DEECs) that, in aggregate, form larger metamaterial frameworks. These resulting DEEC-Tec metamaterials can then, in turn, be used to construct flexible ocean wave energy converters called flexWECs. DEEC-Tec enables flexWECs: (i) to be inherently broad-banded ocean wave frequency energy converters and (ii) to have an inherent lack of highly loaded rigid bodies. The DEEC-Tec domain also benefits the marine renewable energy domain by inherently availing ways that marine energy can be harvested and converted that heretofore has not yet been considered possible: real-time execution of transforming topologies (e.g., actively changing a flexWEC's shape and form) and morphologies (e.g., actively changing a flexWEC's stiffness and damping throughout its entire structure). Presented, is one specific type of DEEC, a HexDEEC, that shows promise in aiding the adoption and further development of the DEEC-Tec domain - it is a small energy transducer being developed by the United States National Renewable Energy Laboratory. The HexDEEC is a small (characteristic length approximating a centimeter) energy transducer that converts the dynamic deformations of an elastomer into electricity through a charging-discharging cycle of a capacitor whose capacitance is varied by those elastic deformations. The HexDEEC is composed of a hyperelastic hexagonal housing (nominally silicon rubber) with six electrodes on its inner faces. The upper three electrodes share the same charge while the lower three electrodes oppose the upper electrode charges. Externally, the HexDEEC has two arms extending away from the middle vertices of the hexagon. Via principles governing the relationship between electrical capacitance and electrical potential (voltage and charge), electricity is generated when the HexDEEC's arms are dynamically pulled or released under tensile loading as doing so causes the distance between the upper and lower sets of electrodes to change - varying the energy converter's overall capacitance. Analytical and numerical modeling have already been used to estimate the electrical energy produced by a HexDEEC. The cursory models approximate the HexDEEC as a parallel plate variable capacitor - simplifying from six to two opposing plates with a constant dielectric volume between those two plates. To account for the elastic HexDEEC material properties, software such as SolidWorks and STAR-CCM+ have been used to generate hyperelastic models; notably, Mooney-Rivlin based models. Individual HexDEECs have been fabricated by drawing uncured liquid silicon rubber into molds via vacuum pressure. To simplify manufacturing, HexDEEC sub-components - e.g., electrodes, wires - can be placed within those molds such that they are directly embedded into the hexagonal housing during the curing process. Furthermore, DEEC-Tec metamaterials can be created by interweaving or sequentially layering multiple HexDEEC strands together. The HexDEEC based metamaterial could then generate electricity through its gross deformations. Ultimately, HexDEECs represent a specific type of energy transducer that can be leveraged, by the DEEC-Tec domain, to create metamaterials used to construct novel flexWECs.

DEEC-Tec↗

End-Use Savings Shapes: Measure Documentation: Add Exhaust Air Heat/Energy Recovery

This documentation focuses on a single end-use savings shape measure—Add Exhaust Air Heat/Energy Recovery. This measure adds exhaust air energy recovery or heat recovery to existing air handling units (AHU) with outdoor air. Systems that already have energy/heat recovery are not modified. Furthermore, food service building types are also not modified by this measure due to the added complication of integrating cooking hood exhaust that could cause heat exchanger fouling from kitchen exhaust. In total, this measure is applicable airloops serving ~70% of the floor area in ComStock. In practice, energy/heat recovery systems are retrofitted to existing air delivery systems either as separate systems that provide outdoor air to the AHUs or are directly integrated to an AHU; the modeling approach used in this study is agnostic of the energy recovery type and simply accounts recovery effectiveness, added static pressure, and other controls which are described further in this document. Energy recovery with sensible and latent exchange gets added in humid climate zones, while heat recovery with sensible-only exchange gets added in drier climate zones. Energy recovery is modeled as a fixed membrane plate counterflow heat exchanger, while heat recovery is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and electric resistance preheat coil for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

In‐operando thermal transport characterization of moving particle bed heat exchanger

The project aimed to develop modulated photothermal radiometry (MPR) for conducting in-operando measurements of thermal transport in moving particle bed heat exchangers (MPBE) located at Sandia National Laboratory (SNL). The plan was to initially conduct lab-scale measurements on a 1-meter-long particle channel at UCSD, followed by in- operando measurements at SNL on a 20 kWth MPBE prototype built for this project, and if time permitting, potential final deployment on SNL’s 1 MWth G3P3 MPBE. The first two goals were successfully achieved but due to changes with commissioning timeline of the G3P3 MPBE, in-operando measurements on the G3P3 MPBE could not be conducted. The measurement campaigns have resulted in some promising results and the MPR tool has been handed over to trained SNL personnel for future use. MPR measurements on UCSD’s 1-meter-long particle channel showed a peculiar length dependence of the particle bed thermal conductivity and near-wall thermal resistance. The bed thermal conductivity increased, and the near-wall thermal resistance decreased, with increasing distance from the channel inlet, both eventually reaching a plateau. This was found to be due to hydrostatic pressure screening by the channel walls, known as the “Janssen effect”, and is the first experimental study on its role in granular heat transfer. A 20 kWth small-scale MPBE prototype, the first of its kind with 3 mm particle channels and 2 mm sCO2 plates, was designed and manufactured by Vacuum Process Engineering (VPE) for this project. This MPBE prototype was installed in SNL’s HEX test stand and the MPR tool was integrated into the test stand for in-operando measurements. Several modifications have been made to the MPR setup for facile installation and easy operation at SNL. Measurements with Carbo HSP40/70 particles were conducted with various particle and sCO2 temperatures and flow rates. Further, apart from regular MPBE operation, fault scenarios such as plate warping, particle stagnation, and choking were also detected and MPR showed excellent sensitivity to the detection of such conditions. Through the course of this project, MPR has evolved from a sensitive laboratory technique to a rugged industrial tool with various applications in high temperature measurements and diagnostics.

14 SOLAR ENERGY↗

Experimental evaluation of thermal-fluids performance of Helium-Cooled Flat Plate (HCFP) divertor

Various helium (He)-cooled solid-tungsten (W) divertor concepts have been proposed for long-pulse magnetic fusion energy reactors. Among these concepts, the He-cooled flat plate divertor (HCFP) modules have the largest plasma-facing surface area of ~0.2 m 2 . Simulations have shown that the most recent version of the design can withstand heat fluxes as great as 8 MW/m 2 . Earlier experimental studies of a single shortened HCFP cooling unit with a slot length of 7.6 cm used air at ambient temperature and pressures below 0.6 MPa. Here, we present initial experimental studies of a copper alloy and steel test section modeling a shortened HCFP cooling unit using He at prototypical pressure of 10 MPa, inlet temperatures T i ≤ 200 °C and steady-state incident heat fluxes q" ≤ 1.2 MW/m 2 . Results for Nusselt number Nu as a function of Reynolds number Re were obtained for Re = 1.2×10 4 –3.4×10 4 , and used to develop a Nu(Re) correlation and validate numerical models of the test section using commercial computational fluid dynamics (CFD) software. Simulations with this model are performed to evaluate the effect of the shortened slot. Furthermore, these analyses are used to estimate the thermal-fluids performance of the HCFP under prototypical conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of shock roughness due to phase plate speckle imprinting relevant for x-ray diffraction experiments on 3rd and 4th generation light sources

Laser-shock compression experiments at 3rd and 4th generation light sources generally employ phase plates, which are inserted into the beamline to achieve a repeatable intensity distribution at the focal plane. Here, the laser intensity profile is characterized by a high-contrast, high-frequency laser speckle. Without sufficient smoothing, these laser non-uniformities can translate to a significant pressure distribution within the sample layer and can affect data interpretation in x-ray diffraction experiments. Here, we use a combination of one- and two-dimensional velocity interferometry to directly measure the extent to which spatial frequencies within the laser focal spot intensity pattern are smoothed out during propagation within the laser plasma and a polyimide ablator. We find that the use of thicker polyimide layers results in spatially smoother shock fronts, with the greatest degree of smoothing associated with the highest spatial frequencies. Focal spots with the smallest initial speckle separation produce the most rapid smoothing. Laser systems that employ smoothing by spectral dispersion techniques to rapidly modulate the focal plane intensity distribution are shown to be the most effective ones in producing a spatially smooth shock front. We show that a simple transport model combined with the known polyimide Hugoniot adequately describes the extent of shock smoothness as a function of polyimide thickness. Finally, our results provide a description of spatial structure smoothing across a shock front, which can be used to design targets on x-ray free electron laser facilities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Northstar Mo99 Window Tests

Tests were completed for window to “first disk” (actually a steel plate for these expariments) gaps of 20 mil as per design gap as well as 10 mil and 30 mil gaps to span the range of possible variations. With possible disk distortion in beam, another test with 0 gap was performed. Based on deflections measured during the pressure test, the 0 gap was most likely very near 3 mil.

43 PARTICLE ACCELERATORS↗

Experimental Characterization of an Additively Manufactured Inconel 718 Heat Exchanger for High-Temperature Applications

This work presents the experimental results of a novel, air-to-air, additively manufactured manifold-microchannel heat exchanger with straight fins on both sides. The heat exchanger was made of Inconel 718 using a direct metal laser sintering technique. The overall core size of the heat exchanger was 94 mm × 87.6 mm × 94.4 mm, with a fin thickness of 0.220 mm on both the hot and cold sides. The heat exchanger was tested with pressurized nitrogen gas at 300 °C and 340 kPa for the hot side, while air at an ambient condition was used for the cold side. An overall heat transfer of 276 W/m2K was obtained for Reynolds number values of 132 and 79 for the cold and hot sides, respectively. A gravimetric heat transfer density (Q/m∆T) of 4.7–6.7 W/kgK and a volumetric heat transfer density (Q/V∆T) of 6.9–9.8 kW/m3K were recorded for this heat exchanger with a coefficient of performance value that varied from 42 to 52 over the operating conditions studied here. The experimental pressure drop results were within 10% of the numerical values, while the corresponding heat transfer results were within 17% of the numerical results, mainly due to imperfections in the fabrication process. Despite this penalty, the performance of the tested heat exchanger was superior to the conventional plate-fin heat exchangers: more than 60% of improvements in both gravimetric and volumetric heat transfer densities were recorded for the entire range of experimental data.

42 ENGINEERING↗

Stress engineering for crack and dendrite prevention in solid electrolytes via ion implantation

Solid-state batteries represent a promising technology that offers safer and more densely packed energy storage. A primary cause of failure in solid-state cells is the penetration of metal dendrites through the solid electrolyte. Here, we report that fluorine-ion implantation can enhance the mechanical resistance of solid electrolyte Li 6.5 La 3 Zr 1.5 Ta 0.5 O 12 to dendrite propagation by inducing residual compressive stress in the subsurface of the electrolyte. Ion implantation modifies subsurface residual stress and also alters the electrolyte’s surface, resulting in multifunctional enhancement. The combined chemical and mechanical effects of ion implantation enable reversible lithium metal stripping and plating at elevated current densities while enhancing air stability and mitigating the formation of a harmful carbonate layer at the surface. This study provides new insights into a scalable dendrite-suppression strategy for designing solid-state batteries suitable for cycling at room temperature and low stack pressures.

25 ENERGY STORAGE↗

Optical transparency of LiF (100) shock compressed to ∼360 GPa

High-purity [100] lithium fluoride (LiF) is the most widely used optical window in dynamic compression experiments due to its wide bandgap and well-characterized mechanical response. Recent plate-impact experiments established the [100] LiF Hugoniot to ∼230 GPa and demonstrated shock-induced melting onset at 182 GPa with complete melting by 195 GPa; theoretical models predict LiF optical transparency to nearly 900 GPa. To experimentally examine the optical transparency of [100] LiF at higher pressures and in the liquid state, laser-driven shock experiments were performed at peak stresses ranging from 223 to 363 GPa. Optical response was examined by measuring the particle velocity histories at the Kapton/LiF interface using laser interferometry at 532 and 1550 nm wavelengths; in-material particle velocities were obtained using established refractive-index corrections. Continuous photonic Doppler velocimetry fringes were observed across the entire stress range, demonstrating that LiF remains transparent to 1550 nm light throughout the multi-megabar regime investigated. At 532 nm, fringe visibility depended on the reflector coating: aluminum mirrors provided signals to ∼235 GPa, while gold mirrors extended this limit to 270.5 GPa, indicating that the shorter-wavelength response is likely sensitive to experimental configuration rather than to the loss of LiF transparency. Continued optical transparency to at least 360 GPa indicates that shock-melted LiF does not display bandgap closure over the stress range explored. Furthermore, these results provide direct experimental constraints on the high-pressure optical response and establish LiF (100) as a robust optical window material for laser-driven dynamic compression experiments approaching 400 GPa.

Renganathan, P. [Argonne National Laboratory (ANL)↗

Convection in Scaled Turbine Internal Cooling Passages With Additive Manufacturing Roughness

Abstract Additive manufacturing processes, such as direct metal laser sintering (DMLS), enable the creation of novel turbine cooling internal passages and systems. However, the DMLS method produces a significant and unique surface roughness. Previous work in scaled passages analyzed pressure losses and friction factors associated with the rough surfaces, as well as investigated the velocity profiles and turbulent flow characteristics within the passage. In this study, the heat transfer characteristics of scaled additively manufactured surfaces were measured using infrared (IR) thermography. Roughness panels were CNC machined from plates of aluminum 6061 to create near isothermal roughness elements when heated. Fluid resistance differences between the aluminum roughness panels and roughness panels constructed from ABS plastic using the same roughness patterns from McClain et al. (2020, “Flow in a Simulated Turbine Blade Cooling Channel With Spatially Varying Roughness Caused by Additive Manufacturing Orientation,” ASME Turbo Expo 2020, Turbomachinery Technical Conference and Exposition, Virtual Conference, Sept. 21–25, GT2020-16069) were investigated. Finally, the overall thermal performance enhancements and friction losses were assessed through the calculation of surface averaged “global thermal performance” ratios. The global thermal performance characterizations indicate results in-line with those found for traditional commercial roughness and slightly below traditional internal passage convection enhancement methods such as swirl chambers, dimples, and ribs. The passages investigated in this study do not include compressibility effects or the long-wavelength artifacts and channel geometric deviations observed by Wildgoose et al. (2020, “Impact of Additive Manufacturing on Internal Cooling Channels with Varying Diameters and Build Directions,” ASME Turbo Expo 2020, Turbomachinery Technical Conference and Exposition, Virtual Conference, Sept. 21–25, GT2020-15049). However, the results of this study indicate that, based on the roughness augmentation alone, artificial convective cooling enhancers such as turbulators or dimples may still be required for additively manufactured turbine component cooling.

Engineering↗

Comparative Analysis of Direct and Indirect Cooling of Wide-Bandgap Power Modules and Performance Enhancement of Jet Impingement-Based Direct Substrate Cooling

With the development of high-power and high-torque machines, requirements for high-power density electronics are increasing. Thermal management of such systems requires high heat extraction. Conventional air cooling based heat sinks and cold plate based liquid cooling have their own benefits for various applications but has limitations for high power density applications. The current study explores a jet impingement based direct substrate cooling system that was implemented for a SiC based direct bonded Cu substrate for various power losses. Numerical comparison between jet impingement cooling and conventional horizontal/indirect cooling (pin fin heat sink and genetic algorithm-optimized heat sink) showed that the area weighted average of the heat transfer coefficient (HTC) is high for both horizontal cooling designs, and the local HTC is higher for jet impingement. Design iterations were undertaken to resolve the bottleneck of this cooling system. Increasing the number of nozzles helped to cover more area at the direct bonded Cu bottom plate, which drops the chip temperature considerably. With a constant flow rate, increasing the number of nozzles would decrease local jet velocity, which reduces the heat extraction by jet impingement. This issue can be addressed by reducing the diameter of nozzle but doing so results in a high pressure drop where the design constraint is 2 psi. A flared nozzle design is proposed, which has a higher spreading angle of the jet that increases the flow coverage and reduces the pressure drop of the coolant loop.

Barua, Himel↗

Atmospheric pressure plasma functionalization of polystyrene

Atmospheric pressure plasma jets (APPJs) are used to improve the adhesive and hydrophilic properties of commodity hydrocarbon polymers such as polypropylene, polyethylene, and polystyrene (PS). These improvements largely result from adding oxygen functional groups to the surface. PS functionalization is of interest to produce high value biocompatible well-plates and dishes, which require precise control over surface properties. In this paper, we discuss results from a computational investigation of APPJ functionalization of PS surfaces using He/O 2 /H 2 O gas mixtures. A newly developed surface reaction mechanism for functionalization of PS upon exposure to these plasmas is discussed. A global plasma model operated in plug-flow mode was used to predict plasma-produced species fluxes onto the PS surface. A surface site balance model was used to predict oxygen-functionalization of the PS following exposure to the plasma and ambient air. We found that O-occupancy on the surface strongly correlates with the O-atom flux to the PS, with alcohol groups and cross-linked products making the largest contributors to total oxygen fraction. Free radical sites, such as alkoxy and peroxy, are quickly consumed in the post-plasma exposure to air through passivation and cross-linking. O-atom fluences approaching 10 17 cm -2 saturate the O-occupancy on the PS surface, creating functionality that is not particularly sensitive to moderate changes in operating conditions.

36 MATERIALS SCIENCE↗

High-Strain Rate Spall Strength Measurement for CoCrFeMnNi High-Entropy Alloy

In this study, we experimentally investigate the high stain rate and spall behavior of Cantor high-entropy alloy (HEA), CoCrFeMnNi. First, the Hugoniot equations of state (EOS) for the samples are determined using laser-driven CoCrFeMnNi flyers launched into known Lithium Fluoride (LiF) windows. Photon Doppler Velocimetry (PDV) recordings of the velocity profiles find the EOS coefficients using an impedance mismatch technique. Following this set of measurements, laser-driven aluminum flyer plates are accelerated to velocities of 0.5–1.0 km/s using a high-energy pulse laser. Upon impact with CoCrFeMnNi samples, the shock response is found through PDV measurements of the free surface velocities. From this second set of measurements, the spall strength of the alloy is found for pressures up to 5 GPa and strain rates in excess of 106 s−1. Further analysis of the failure mechanisms behind the spallation is conducted using fractography revealing the occurrence of ductile fracture at voids presumed to be caused by chromium oxide deposits created during the manufacturing process.

36 MATERIALS SCIENCE↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗