Search NASA⌕ Search

SEARCH · Search NASA

Results for “probability analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Bayesian Framework For Bioburden Density Calculations To Perform Planetary Protection Probabilistic Risk Assessment

The planetary protection discipline aims to minimize the microbial contamination on spacecraft to prevent the inadvertent contamination of other planetary bodies, known as forward planetary protection (PP). Planetary protection probabilistic risk assessment (PRA) relies on two core methodologies-the contamination probability event tree analysis and statistical parameter estimation. Planetary protection engineers combine several techniques to estimate the bioburden present on spacecraft components. A direct assay to enumerate CFU (colony forming units) is the preferred methodology, but given a similar processing environment the bioburden present on certain components is inferred using: (1) a NASA defined bioburden estimate based upon the biological cleanliness of the manufacturing/assembly environment or (2) sampled data from a similar spacecraft component. The paper presents an empirical Bayesian framework to systematically treat bioburden estimation and its uncertainties on different levels starting with measurement procedures to combining different components to subsystems and whole spacecraft. It is shown that the Bayesian approach can effectively handle estimations and their uncertainties at different levels and produce a reliable estimate for bioburden to be used to evaluate the probability of contamination.

Seuylemezian, Arman↗

Novel Biomedical Device Utilizing Light-Emitting Nanostructures Developed

Sketches and chemical diagrams of state-of-the-art device and novel proposed device are presented. Current device uses a diode laser that emits into a fluorescent fluid only one wavelength and a photodetector diode that detects only one wavelength. Only one type of bacteria can be detected. The proposed device uses a quantum dot array that emits into a fluorescent fluid multiple wavelengths and an NIR 512 spectrometer that scans 0.8- to 1.7-mm wavelengths. Hundreds of different bacteria and viruses can be detected. A novel biomedical device is being developed at the NASA Glenn Research Center in cooperation with the University of Michigan. This device uses nano-structured quantum dots that emit light in the near-infrared (IR) region. The nanostructured quantum dots are used as a source and excite fluorochrome polymers coupled with antibodies that seek out and attach to specific bacteria and viruses. The fluorochrome polymers/antibodies fluoresce at specific wavelengths in the near-IR spectrum, but these wavelengths are offset from the excitation wavelength and can be detected with a tunable spectrometer. The device will be used to detect the presence of viruses and bacteria in simple fluids and eventually in more complex fluids, such as blood. Current state-of-the-art devices are limited to single bacteria or virus detection and a considerable amount of time and effort is required to prepare samples for analysis. Most importantly, the devices are quite large and cumbersome, which prohibits them from being used on the International Space Station and the space shuttles. This novel device uses nanostructured quantum dots which, through molecular beam epitaxy and highly selective annealing processes, can be developed into an illumination source that could potentially generate hundreds of specific wavelengths. As a result, this device will be able to excite hundreds of antibody/fluorochrome polymer combinations, which in turn could be used to detect hundreds of bacteria and viruses in fluids. A novel sample preparation technique that exploits micromembrane filtration and centrifugation methods has been developed for this device. The technique greatly reduces the time required to prepare the sample and the amount of sample needed to perform an accurate and comprehensive analysis. Last, and probably most important, because of the nano-light-emitting source and the novel sample preparation technique, the overall size of the device could be reduced dramatically. This device will serve as a nanoscale lab-on-a-chip for in situ microorganism detection and will enable tests to be performed on a time scale of minutes rather than days. Thus, it is ideally suited for monitoring the environmental conditions onboard the International Space Station and the space shuttles, thereby enhancing the safety of the astronauts. In addition, the device has important commercial applications, such as detecting the presence of bacteria and viruses in water at food- and beverage-processing centers, water treatment plants, and restaurants. Also, this technology has the potential to be used to detect bacteria and viruses in more complex fluids, such as blood--which in all likelihood would revolutionize blood analysis as it is performed today. This project was made possible through the Director's Discretionary Fund and is ongoing. In addition, this project provides funding to Dr. Rachel Goldman of the University of Michigan for the research and development of nanostructured quantum dots.

Scardelletti, Maximilian C.↗

Development of STS/Centaur failure probabilities liftoff to Centaur separation

The results of an analysis to determine STS/Centaur catastrophic vehicle response probabilities for the phases of vehicle flight from STS liftoff to Centaur separation from the Orbiter are presented. The analysis considers only category one component failure modes as contributors to the vehicle response mode probabilities. The relevant component failure modes are grouped into one of fourteen categories of potential vehicle behavior. By assigning failure rates to each component, for each of its failure modes, the STS/Centaur vehicle response probabilities in each phase of flight can be calculated. The results of this study will be used in a DOE analysis to ascertain the hazard from carrying a nuclear payload on the STS.

Hudson, J. M.↗

A timer inventory based upon manual and automated analysis of ERTS-1 and supporting aircraft data using multistage probability sampling

A quasi-operational study demonstrating that a timber inventory based on manual and automated analysis of ERTS-1, supporting aircraft data and ground data was made using multistage sampling techniques. The inventory proved to be a timely, cost effective alternative to conventional timber inventory techniques. The timber volume on the Quincy Ranger District of the Plumas National Forest was estimated to be 2.44 billion board feet with a sampling error of 8.2 percent. Costs per acre for the inventory procedure at 1.1 cent/acre compared favorably with the costs of a conventional inventory at 25 cents/acre. A point-by-point comparison of CALSCAN-classified ERTS data with human-interpreted low altitude photo plots indicated no significant differences in the overall classification accuracies.

Nichols, J. D.↗

Physics-coupled data-driven design of high-temperature alloys

We present a materials design loop, which streamlines physics-coupled machine learning (ML) surrogate models to discover new alloy chemistries with improved properties. The efficacy is demonstrated by discovering a high-temperature alumina-forming austenitic (AFA) stainless steel with enhanced creep, followed by experimental validation. The ML models have been trained using a well-curated, highly consistent experimental dataset augmented with synthetic microstructural features from a computational thermodynamic approach. We have populated a large number of hypothetical AFA alloys to explore the high-dimensional composition space and have predicted their creep properties by providing the same synthetic input features obtained from the trained ML models. Uncertainties from the ML training were taken as thresholds for truncating predicted results to identify alloys with improved or deteriorated creep. Individual elemental compositions have been determined via probability density distribution analysis from the group of alloys at the top and bottom of the predicted creep values for further virtual and experimental validations. In conclusion, we anticipate that this workflow can be applied to screen desired conditions, such as chemistry and processing parameters, in high-dimensional space through physics-guided data analytics.

Alloy design↗

Automated Patient Identification and Localization Error Detection Using 2-Dimensional to 3-Dimensional Registration of Kilovoltage X-Ray Setup Images

Purpose: To determine whether kilovoltage x-ray projection radiation therapy setup images could be used to perform patient identification and detect gross errors in patient setup using a computer algorithm. Methods and Materials: Three patient cohorts treated using a commercially available image guided radiation therapy (IGRT) system that uses 2-dimensional to 3-dimensional (2D-3D) image registration were retrospectively analyzed: a group of 100 cranial radiation therapy patients, a group of 100 prostate cancer patients, and a group of 83 patients treated for spinal lesions. The setup images were acquired using fixed in-room kilovoltage imaging systems. In the prostate and cranial patient groups, localizations using image registration were performed between computed tomography (CT) simulation images from radiation therapy planning and setup x-ray images corresponding both to the same patient and to different patients. For the spinal patients, localizations were performed to the correct vertebral body, and to an adjacent vertebral body, using planning CTs and setup x-ray images from the same patient. An image similarity measure used by the IGRT system image registration algorithm was extracted from the IGRT system log files and evaluated as a discriminant for error detection. Results: A threshold value of the similarity measure could be chosen to separate correct and incorrect patient matches and correct and incorrect vertebral body localizations with excellent accuracy for these patient cohorts. A 10-fold cross-validation using linear discriminant analysis yielded misclassification probabilities of 0.000, 0.0045, and 0.014 for the cranial, prostate, and spinal cases, respectively. Conclusions: An automated measure of the image similarity between x-ray setup images and corresponding planning CT images could be used to perform automated patient identification and detection of localization errors in radiation therapy treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Properties of hydrothermally synthesized Zn{sub 2}SnO{sub 4} nanoparticles using Na{sub 2}CO{sub 3} as a novel mineralizer

Zn{sub 2}SnO{sub 4} nanoparticles with a band gap of 2.96-3.36 eV were synthesized via a simple hydrothermal method using Na{sub 2}CO{sub 3} as a new mineralizer. The effects of the concentration of Na{sub 2}CO{sub 3} on the formation, morphology and optical properties of the Zn{sub 2}SnO{sub 4} nanoparticles are discussed. Also, the reaction parameters, such as the reaction temperature and reaction time, were optimized. The as-synthesized Zn{sub 2}SnO{sub 4} nanoparticles exhibit no impurity phases such as SnO{sub 2} and ZnO throughout the entire process, as confirmed by X-ray diffraction (XRD) and transmission electron microscopy (TEM) studies. Also, the formation of impurity free Zn{sub 2}SnO{sub 4} nanoparticles in the presence of Na{sub 2}CO{sub 3} is explained by a unique hydrothermal reaction sequence. The average particle size of the highly crystalline Zn{sub 2}SnO{sub 4} nanoparticles was controllable by adjusting the mineralizer concentration, which enabled the facile tuning of the bandgap. From the photoluminescence (PL) study, two emission bands could be found after peak analysis, which are probably due to the presence of oxygen or cation vacancies generated during the hydrothermal process. These bands were shifted to lower frequencies as the concentration of the Na{sub 2}CO{sub 3} mineralizer increased.

36 MATERIALS SCIENCE↗

The Mammary Epithelial Cell Secretome and its Regulation by Signal Transduction Pathways

Extracellular proteins released by mammary epithelial cells are critical mediators of cell communication, proliferation and organization, yet the actual spectrum of proteins released by any given cell (the secretome) is poorly characterized. To define the set of proteins secreted by human mammary epithelial cells (HMEC), we combined analytical and computational approaches to define a secretome protein set based upon probable biological significance. Analysis of HMEC-conditioned medium by liquid chromatography-mass spectrometry resulted in identification of 889 unique proteins, of which 151 were found to be specifically enriched in the extracellular compartment when compared with a database of proteins expressed in whole HMEC lysates. Additional high mass accuracy analysis revealed 36 proteins whose extracellular abundance increased after treatment with phorbol ester (PMA), a protein kinase C agonist and general secretagogue. Many of the PMA stimulated proteins have been reported to be aberrantly expressed in human cancers and appear to be co-regulated as multigene clusters. By inhibiting PMA-mediated transactivation of the epidermal growth factor receptor (EGFR), a pathway critically required for normal HMEC function, we found that the secretion of specific matrix metalloproteases were also coordinately regulated through EGFR transactivation. This study demonstrates a tiered strategy by which extracellular proteins can be identified and progressively assigned to classes of increasing confidence and regulatory importance.

59 BASIC BIOLOGICAL SCIENCES↗

On a stochastic approach to a code performance estimation

The main goal of an efficient profiling of software is to minimize the runtime overhead under certain constraints and requirements. The traces built by a profiler during the work, affect the performance of the system itself. One of important aspect of an overhead arises from the randomness of variability in the context in which the application is embedded, e.g., due to possible cache misses, etc. Such uncertainty needs to be taken into account in the design phase. In order to overcome these difficulties we propose to investigate this issue through the analysis of the probability distribution of the difference between profiler’s times for the same code. The approximating model is based on the finite normal mixtures within the framework of the method of moving separation of mixtures. We demonstrate some results for the MATLAB profiler using plotting of 3D surfaces by the function surf. The idea can be used for an estimating of a program efficiency.

97 MATHEMATICS AND COMPUTING↗

CHROMOSPHERIC VARIABILITY IN SLOAN DIGITAL SKY SURVEY M DWARFS. II. SHORT-TIMESCALE H{alpha} VARIABILITY

We present the first comprehensive study of short-timescale chromospheric H{alpha} variability in M dwarfs using the individual 15 minute spectroscopic exposures for 52, 392 objects from the Sloan Digital Sky Survey. Our sample contains about 10{sup 3}-10{sup 4} objects per spectral type bin in the range M0-M9, with a typical number of three exposures per object (ranging up to a maximum of 30 exposures). Using this extensive data set, we find that about 16% of the sources exhibit H{alpha} emission in at least one exposure, and of those about 45% exhibit H{alpha} emission in all of the available exposures. As in previous studies of H{alpha} activity (L{sub H{alpha}/}L{sub bol}), we find a rapid increase in the fraction of active objects from M0-M6. However, we find a subsequent decline in later spectral types that we attribute to our use of the individual spectra. Similarly, we find saturated activity at a level of L{sub H{alpha}/}L{sub bol} {approx} 10{sup -3.6} for spectral types M0-M5 followed by a decline to about 10{sup -4.3} in the range M7-M9. Within the sample of objects with H{alpha} emission, only 26% are consistent with non-variable emission, independent of spectral type. The H{alpha} variability, quantified in terms of the ratio of maximum to minimum H{alpha} equivalent width (R{sub EW}), exhibits a rapid rise from M0 to M5, followed by a plateau and a possible decline in M9 objects. In particular, variability with R{sub EW} {approx}> 10 is only observed in objects later than M5, and survival analysis indicates a probability of {approx}<0.1% that the R{sub EW} values for M0-M4 and M5-M9 are drawn from the same distribution. We further find that for an exponential distribution, the R{sub EW} values follow N(R{sub EW}) {proportional_to} exp[ - (R{sub EW} - 1)/2.3] for M0-M4 and {proportional_to}exp[ - (R{sub EW} - 1)/2.9] for M5-M9. Finally, comparing objects with persistent and intermittent H{alpha} emission, we find that the latter exhibit greater variability. Based on these results, we conclude that H{alpha} variability in M dwarfs on timescales of 15 minutes to 1 hr increases with later spectral type, and that the variability is larger for intermittent sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A POSSIBLE BINARY SYSTEM OF A STELLAR REMNANT IN THE HIGH-MAGNIFICATION GRAVITATIONAL MICROLENSING EVENT OGLE-2007-BLG-514

We report the extremely high-magnification (A > 1000) binary microlensing event OGLE-2007-BLG-514. We obtained good coverage around the double peak structure in the light curve via follow-up observations from different observatories. The binary lens model that includes the effects of parallax (known orbital motion of the Earth) and orbital motion of the lens yields a binary lens mass ratio of q = 0.321 {+-} 0.007 and a projected separation of s = 0.072 {+-} 0.001 in units of the Einstein radius. The parallax parameters allow us to determine the lens distance D{sub L} = 3.11 {+-} 0.39 kpc and total mass M{sub L} = 1.40 {+-} 0.18 M{sub Sun }; this leads to the primary and secondary components having masses of M{sub 1} = 1.06 {+-} 0.13 M{sub Sun} and M{sub 2} = 0.34 {+-} 0.04 M{sub Sun }, respectively. The parallax model indicates that the binary lens system is likely constructed by the main-sequence stars. On the other hand, we used a Bayesian analysis to estimate probability distributions by the model that includes the effects of xallarap (possible orbital motion of the source around a companion) and parallax (q = 0.270 {+-} 0.005, s = 0.083 {+-} 0.001). The primary component of the binary lens is relatively massive, with M{sub 1} = 0.9{sup +4.6}{sub -0.3} M{sub Sun} and it is at a distance of D{sub L} = 2.6{sup +3.8}{sub -0.9} kpc. Given the secure mass ratio measurement, the companion mass is therefore M{sub 2} = 0.2{sup +1.2}{sub -0.1} M{sub Sun }. The xallarap model implies that the primary lens is likely a stellar remnant, such as a white dwarf, a neutron star, or a black hole.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray and γ-ray studies of the millisecond pulsar and possible X-ray binary/radio pulsar transition object PSR J1723-2837

We present X-ray observations of the 'redback' eclipsing radio millisecond pulsar (MSP) and candidate radio pulsar/X-ray binary transition object PSR J1723-2837. The X-ray emission from the system is predominantly non-thermal and exhibits pronounced variability as a function of orbital phase, with a factor of ∼2 reduction in brightness around superior conjunction. Such temporal behavior appears to be a defining characteristic of this variety of peculiar MSP binaries and is likely caused by a partial geometric occultation by the main-sequence-like companion of a shock within the binary. There is no indication of diffuse X-ray emission from a bow shock or pulsar wind nebula associated with the pulsar. We also report on a search for point source emission and γ-ray pulsations in Fermi Large Area Telescope data using a likelihood analysis and photon probability weighting. Although PSR J1723-2837 is consistent with being a γ-ray point source, due to the strong Galactic diffuse emission at its position a definitive association cannot be established. No statistically significant pulsations or modulation at the orbital period are detected. For a presumed detection, the implied γ-ray luminosity is ≲5% of its spin-down power. This indicates that PSR J1723-2837 is either one of the least efficient γ-ray producing MSPs or, if the detection is spurious, the γ-ray emission pattern is not directed toward us.

79 ASTRONOMY AND ASTROPHYSICS↗

Searching for magnetic fields in 11 Wolf-Rayet stars: Analysis of circular polarization measurements from ESPaDOnS

With recent detections of magnetic fields in some of their progenitor O stars, combined with known strong fields in their possible descendant neutron stars, it is natural to search for magnetic fields in Wolf-Rayet (WR) stars, despite the problems associated with the presence of winds enhanced by an order of magnitude over those of O stars. We continue our search among a sample of 11 bright WR stars following our introductory study in a previous paper of WR6 = EZ CMa using the spectropolarimeter ESPaDOnS at Canada-France-Hawaii Telescope, most of them in all four Stokes parameters. This sample includes six WN stars and five WC stars encompassing a range of spectral subclasses. Six are medium/long-period binaries and three show corotating interaction regions. We report no definite detections of a magnetic field in the winds in which the lines form (which is about the same distance from the center of the star as it is from the surface of the progenitor O star) for any of the eleven stars. Possible reasons and their implications are discussed. Nonetheless, the data show evidence supporting marginal detections for WR134, WR137, and WR138. According to the Bayesian analysis, the most probable field intensities are B {sub wind} ∼ 200, 130, and 80 G, respectively, with a 95.4% probability that the magnetic fields present in the observable parts of their stellar wind, if stronger, does not exceed B{sub wind}{sup max}∼1900 G, ∼1500 G, and ∼1500 G, respectively. In the case of non-detections, we report an average field strength upper limit of B{sub wind}{sup max}∼500 G.

79 ASTRONOMY AND ASTROPHYSICS↗

Accurate crystal-structure refinement of Ca{sub 3}Ga{sub 2}Ge{sub 4}O{sub 14} at 295 and 100 K and analysis of the disorder in the atomic positions

The accurate X-ray diffraction study of a Ca{sub 3}Ga{sub 2}Ge{sub 4}O{sub 14} crystal (sp. gr. P321, Z = 1) has been performed using repeated X-ray diffraction data sets collected on a diffractometer equipped with a CCD area detector at 295 and 100 K. The asymmetric disorder in the atomic positions in Ca{sub 3}Ga{sub 2}Ge{sub 4}O{sub 14} is described in two alternative ways: with the use of anharmonic atomic displacements (at 295 K R/wR = 0.68/0.60%, 3754 reflections; at 100 K R/wR = 0.90/0.70%, 3632 reflections) and using a split model (SM) (at 295 K R/wR = 0.74/0.67%; at 100 K R/wR = 0.95/0.74%). An analysis of the probability density function that defines the probability of finding an atom at a particular point in space shows that, at 295 K, five of the seven independent atoms in the unit cell are asymmetrically disordered in the vicinity of their sites, whereas only three atoms are disordered at 100 K. At both temperatures the largest disorder is observed at the 3f site on a twofold axis, which is a prerequisite for the formation of helicoidal chains of atoms along the c axis of the crystal and can serve as a structural basis for multiferroic properties of this family of crystals with magnetic ions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Partial Electron Localization in a Finite-Size Superlattice Placed in an Electric Field

Partial electron localization in a finite-size superlattice placed in an electric field is considered. The role of electric field in forming of quasilocalized states is investigated. A quantitative criterion for the degree of partial localization is suggested based on analysis of maximal probability density of finding an electron at a given point. It is found that with increase in the electric field the degree of localization does not increase monotonically. Furthermore, the localization is affected stronger by the amplitude of superlattice potential than by the electric field.

36 MATERIALS SCIENCE↗

Implications of Initial LHC Searches for Supersymmetry

The CMS and ATLAS Collaborations have recently published the results of initial direct LHC searches for supersymmetry analyzing ~ 35/pb of data taken at 7 TeV in the centre of mass. We incorporate these results into a frequentist analysis of the probable ranges of parameters of simple versions of the minimal supersymmetric extension of the Standard Model (MSSM), namely the constrained MSSM (CMSSM), a model with common non-universal Higgs masses (NUHM1), the very constrained MSSM (VCMSSM) and minimal supergravity (mSUGRA). We present updated predictions for the gluino mass, m_gl, the light Higgs boson mass, M_h, BR(B_s to mu mu) and the spin-independent dark matter scattering cross section, sigma_SI. The CMS and ATLAS data make inroads into the CMSSM, NUHM1 and VCMSSM (but not mSUGRA) parameter spaces, thereby strengthening previous lower limits on sparticle masses and upper limits on sigma_SI in the CMSSM and VCMSSM. The favoured ranges of BR(B_s to mu mu) in the CMSSM, VCMSSM and mSUGRA are close to the Standard Model, but considerably larger values of BR(B_s to mu mu) are possible in the NUHM1. Applying the CMS and ATLAS constraints improves the consistency of the model predictions for M_h with the LEP exclusion limits.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the Kaon Production Normalization in the NuMI Target Using Uncontained Charged-Current Muon Neutrino Interactions in the NOvA Far Detector

aNOvA is a long-baseline neutrino oscillation experiment that uses the NuMI beam from Fermilab. Its physics goals include providing constraints to the neutrino mass hierarchy and the CP-violating phase $\delta$ by precision measurements of the electron (anti)neutrino appearance in a muon (anti)neutrino beam. Similarly, new limits on the values of $\sin^2{\theta_{23}}$ and $\Delta m^{2}_{32}$ will be achieved by measurements of the muon (anti)neutrino disappearance probabilities. A combined analysis measurement will allow a better resolution of the $\theta_{23}$ octant. The NuMI beam is produced by the collision of high energy protons into a target, giving rise to kaon and pion mesons that decay to neutrinos of a specific flavor. This thesis presents a measurement of the kaon production normalization scale using uncontained charged-current muon neutrinos at the Far Detector. Because the neutrino beam is not pure in flavor, it contains an admixture of other different n eutrino flavors that become a source of background. %in oscillation analysis. Therefore, it is of paramount importance for accelerator experiments, such as NOvA, to have a reliable flux prediction of the neutrino beam in order to achieve its physics goals. One method to constrain the flux is to constrain and measure each flux component independently. The kaon component contributes to the intrinsic $\nu_{e}$ contamination of the beam, a key background for the $\nu_{e}$-appearance analysis. We observed that the uncontained sample in the 10-20 GeV region corresponds to the kaon component of the NuMI beam at the Far Detector. We also found a 60-80\% correlation between the Near Detector $\nu_{e}$ background and the Far Detector $\nu_{\mu}$ uncontained signal. The data used for this analysis was collected from October 2014 to February 2017, corresponding to $7.99 \times 10^{20}$ protons-on-target (POT). The ratio between the Far Detector data and the simulation is fitted to a lin e in the 10-20 GeV energy region. Calibration, energy scale,! final state interactions and neutrino flux (e.g. beam transport and hadron production shape only) systematic uncertainties are considered. The kaon production normalization scale is measured to be $S_{K} = 1.07 \pm 0.16$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗