Search NASA⌕ Search

SEARCH · Search NASA

Results for “procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Light Water Reactor Sustainability Program: Use of Time Distributions to Predict Operator Procedure Performance in Dynamic Human Reliability Analysis

The Human Unimodel for Nuclear Technology to Enhance Reliability (HUNTER) framework affords software capable of conducting human reliability analysis (HRA) using a dynamic approach built around operating procedures (OPs) from nuclear power plants (NPPs). Previous HUNTER reports document the development of this software tool, the coupling of HUNTER to the simulator code, the collection of operator performance data by using simulators to calibrate HUNTER models, and linking HUNTER to probabilistic risk assessment (PRA) software. The present report largely addresses two topics. The first is a new function in HUNTER called the HUNTER Procedure Performance Predictor (P3). HUNTER P3 uses HUNTER’s built in Monte Carlo tools featuring human performance variability to identify potential error traps in procedures. The second topic is time distribution analysis to generate time inputs for dynamic HRA. The current analysis was performed to investigate time distributions for task primitives, which are the minimum task unit of analysis used in dynamic HRA modeling. Using the time distribution data, the elapsed time for human actions in an extended loss of AC power (ELAP) scenario is then investigated. Time data and prediction are essential for modeling procedure performance.

99 GENERAL AND MISCELLANEOUS↗

Relevance of Generation Interconnection Procedures to Feed-in Tariffs in the United States

Feed-in tariffs (FITs) have been used to promote renewable electricity development in over 40 countries throughout the past two decades. These policies generally provide guaranteed prices for the full system output from eligible generators for a fixed time period (typically 15-20 years). Due in part to the success of FIT policies in Europe, some jurisdictions in the United States are consideringimplementing similar policies, and a few have already put such policies in place. This report is intended to offer some guidance to policymakers and regulators on how generator interconnection procedures may affect the implementation of FITs and how state generator interconnection procedures can be formulated to support state renewable energy objectives. This report is based on a literaturereview of model interconnection procedures formulated by several organizations, as well as other documents that have reviewed, commented on, and in some cases, ranked state interconnection procedures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Procedure Automation Rating Matrix

The National Aeronautics and Space Administration (NASA) Advanced Air Mobility (AAM) National Campaign (NC) is researching the means by which future Urban Air Mobility (UAM) aircraft will operate safely in an integrated and scalable airspace architecture. Consistent with this objective, the NASA NC Airspace Procedures team designed a matrix to evaluate UAM instrument flight procedure design, flyability and interoperability of candidate departure, enroute, and approach architectures in live flight or simulation. The Procedure Automation Rating Matrix (PARM) is a multi-dimensional rating scale designed to provide direct feedback from test pilots and operators to airspace procedure designers developing airspace constructs for the integration and scalability of AAM operations in the National Airspace System (NAS). The PARM is assessed using a hierarchical decision tree that guides the operator through a ten-point alpha-numeric rating scale initiated either with or without the use of automation.

National Campaign↗

eVTOL Vehicle-Agnostic Instrument Flight Procedures Test Plan

NASA Advanced Air Mobility National Campaign is researching the utility of electric vertical takeoff and land (eVTOL) advanced air mobility (AAM) instrument flight procedures. The result will be dynamic and tailored procedures that align to the following modus operandi: maximize safety, optimize efficiency, support passenger comfort and minimize acoustics. This is achieved through dynamic airspace procedure design, which is a modular approach to create an airspace construct that customizes procedures to vehicle design and configuration, operation and environmental conditions. The test plan supports different eVTOL platforms and envisioned operations for flight test or simulation and may be leveraged by AAM aircraft manufacturers and operators for any given aircraft, location and operation.

eVTOL test plan↗

CONSIDERATIONS FOR THE TREATMENT OF COMPUTERIZED PROCEDURES IN HUMAN RELIABILITY ANALYSIS

Computerized procedures (CPs) are an emerging technology within nuclear power plant control rooms. While CPs have been implemented internationally in advanced control rooms, to date no US nuclear power plant has implemented CPs in its main control room. Yet, CPs are a reality of new plant builds and are an area of considerable interest to existing plants, which see advantages in terms of easier records management by omitting the need for updating hardcopy procedures. The overall intent of this paper is to provide a characterization of human reliability analysis (HRA) issues for computerized procedures. It is beyond the scope of this document to propose a new HRA approach or to recommend specific methods or refinements to those methods. Rather, this paper serves as a review of current HRA as it may be used for the analysis and review of computerized procedures.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

HUMAN RELIABILITY ANALYSIS FOR COMPUTERIZED PROCEDURES, PART TWO: APPLICABILITY OF CURRENT METHODS

Computerized procedures (CPs) are an emerging technology within nuclear power plant control rooms. While CPs have been implemented internationally in advanced control rooms, to date no U.S. nuclear power plant has implemented CPs in its main control room. Yet, CPs are a reality of new plant builds and are an area of considerable interest to existing plants, which see advantages in terms of easier records management by omitting the need for updating hardcopy procedures. The overall intent of this paper is to provide a characterization of human reliability analysis (HRA) issues for computerized procedures. It is beyond the scope of this document to propose a new HRA approach or to recommend specific methods or refinements to those methods. Rather, this paper serves as a review of current HRA as it may be used for the analysis and review of computerized procedures.

99 GENERAL AND MISCELLANEOUS↗

Current Human Reliability Analysis Methods Applied to Computerized Procedures

Computerized procedures (CPs) are an emerging technology within nuclear power plant control rooms. While CPs have been implemented internationally in advanced control rooms, to date no US nuclear power plant has implemented CPs in its main control room (Fink et al., 2009). Yet, CPs are a reality of new plant builds and are an area of considerable interest to existing plants, which see advantages in terms of enhanced ease of use and easier records management by omitting the need for updating hardcopy procedures. The overall intent of this paper is to provide a characterization of human reliability analysis (HRA) issues for computerized procedures. It is beyond the scope of this document to propose a new HRA approach or to recommend specific methods or refinements to those methods. Rather, this paper serves as a review of current HRA as it may be used for the analysis and review of computerized procedures.

99 GENERAL AND MISCELLANEOUS↗

Intraarticular Sacroiliac Joint Injection Under Computed Tomography Fluoroscopic Guidance: A Technical Note to Reduce Procedural Time and Radiation Dose

PurposeA technique for computed tomography fluoroscopy (CTF)-guided intraarticular (IA) sacroiliac joint (SIJ) injection was devised to limit procedural time and radiation dose.MethodsOur Institutional Review Board approved this retrospective analysis and waived the requirement for informed consent. Overall, 36 consecutive diagnostic or therapeutic IA SIJ injections (unilateral, 20; bilateral, 16) performed in 34 patients (female, 18; male, 16) with a mean age of 45.5 years (range 20–76 years) under CTF guidance were analyzed, assessing technical success (i.e., IA contrast spread), procedural time, and radiation dose.ResultsAll injections were successful from a technical perspective and were free of serious complications. Respective median procedural times and effective doses of SIJ injection were as follows: unilateral, 5.28 min (range 3.58–8.00 min) and 0.11 millisievert (mSv; range 0.07–0.24 mSv); and bilateral, 6.72 min (range 4.17–21.17 min) and 0.11 mSv (range 0.09–0.51 mSv).ConclusionsGiven the high rate of technical success achieved in limited time duration and with little radiation exposure, CTF-guided IA SIJ injection is a practical and low-risk procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Doses to Operators in Hepatobiliary Interventional Procedures

PurposeThe primary aim of this study is to provide a summary of operators’ radiation doses during hepatobiliary fluoroscopic guided procedures. In addition, patient dose in these procedures was also documented.Materials and MethodsA total of 283 transarterial chemoembolisation (TACE) and 302 biliary procedures, including 52 percutaneous transhepatic cholangiogram (PTC), 36 bilioplasty and 214 biliary catheter changes (BCC) performed over 14 months, were included. Electronic personal dosimeters were used to measure operator radiation doses. Effective dose (E) was calculated using modified Niklason algorithm. Patient dose was measured as dose area product (DAP) and fluoroscopy time (FT).ResultsFor TACE, E for radiologist ranged between 0 and 9.96 µSv, for radiographer 0–0.99 µSv and for nurse 0–4.65 µSv. The patient DAP and FT ranged between 1.5 and 421.9 Gy cm{sup 2} and 1.91–67.25 min. For PTC, E for the radiologist ranged between 0.33 and 55.89 µSv, for radiographer 0–38.61 µSv and for nurse 0–3.18 µSv. Patient DAP and FT ranged between 1.7 and 218.4 Gy cm{sup 2} and 2.07–71.53 min. For bilioplasty, E ranged between 0.09 and 9.24 µSv for radiologist, 0–0.84 µSv for radiographer and 0–1.38 µSv for nurse. The patients’ DAP and FT ranged from 0.7 to 52.54 Gy cm{sup 2} and 1.13–24.47 min. For BCC, E ranged from 0 to 12.78 µSv for radiologist, 0–8.43 µSv for radiographer and 0–4.05 µSv for nurse. Patient DAP and FT ranged between 0.12 and 117.3 Gy cm{sup 2} and 0.57–15.83 min.ConclusionsThis study shows that doses to all operators performing hepatobiliary interventional procedures can be very low.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image Fusion Guidance with Pre-procedural CT with Real-Time Fluoroscopy for Adrenal Venous Sampling

PurposeTo assess the effectiveness of image fusion guidance (IF) with pre-procedural computed tomography (CT) with intraprocedural fluoroscopy for adrenal venous sampling (AVS).Materials and MethodsAVS before and after ACTH stimulation including bilateral segmental sampling of effluent tributaries was performed in 62 patients with IF. A 3D volume rendering image, including adrenal glands and veins extracted from previously obtained contrast-enhanced CT images, was manually registered to the real-time X-ray fluoroscopy. The technical success rates, procedure time, radiation exposure, and volume of contrast medium used were compared with 49 patients who underwent AVS without IF.ResultsNo significant differences in the technical success rates with and without IF were observed (98.4 vs. 91.8% for the right adrenal veins, p = 0.168, and 98.4 vs. 100% for the left adrenal veins, p = 1.000). The procedure time with IF was significantly shorter than that without IF (95.6 ± 18.8 vs. 108.4 ± 20.0 min, p = 0.001). The total dose-area product with IF was significantly lower than that without IF (43.1 ± 30.7 vs. 72.2 ± 45.3 Gy cm{sup 2}, p < 0.001). The contrast medium volume used with IF was significantly lower than that without IF (54.6 ± 21.9 vs. 65.7 ± 27.6 mL, p = 0.020).ConclusionsAlthough the contribution to improving the technical success rates was small in our study, IF can effectively reduce procedure time, radiation exposure, and volume of contrast medium during AVS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An improved scaling procedure for analysis and simplification of process models

Systematic scaling analysis of model equations can be valuable as a tool for developing computationally tractable simulations of physical systems. The scaling analysis methods in literature pose difficulties in the calculation of scale and reference values, when nonlinear terms are involved in the model equations. Further, existing methods involve trial and error procedures in the scaling process. Here in this paper, a systematic approach for handling nonlinear terms is suggested, which results in appropriate scale and reference values that render the dimensionless variable variations to be of order one. Further, trial and error procedures are avoided through a new approach wherein a set of nonlinear algebraic equations are solved to identify the scale and reference values. The proposed scaling approach is common to any given model equations with fixed parameters. However, it is to be noted that the proposed procedure may not handle situations when model equations exhibit steady state multiplicity and have dynamic multi-mode regimes. The proposed scaling procedure is illustrated through various examples of different complexities. A 1D model of WGS reactor as a case study shows the effectiveness of the obtained scale and reference values in obtaining simplified model which represents the steady state and dynamic variations of the variables.

42 ENGINEERING↗

The Henri Mondor Procedure of Morbidity and Mortality Review Meetings: Prospective Registration of Clinical, Dosimetric, and Individual Radiosensitivity Data of Patients With Severe Radiation Toxicity

Purpose: After radiation therapy (RT), various radiation-induced toxicities can develop in about one-fourth of patients. An international interest in using morbidity and mortality rates to monitor the quality of care and integrate morbidity and mortality review (MMR) meetings into organizations' governance processes has arisen. We report the first results of patients included in our MMR procedure that included biological assays for individual intrinsic radiosensitivity (IIRS). Methods and Materials: Twenty-three patients were prospectively included in the MMR database. Twenty-two were evaluable for IIRS. Prostate (n=10) and breast (n=8) cancers were the most frequent disease types. The total dose delivered, determined according to the type of disease, ranged from 30 to 74 Gy. Our MMR procedure requires strict criteria: patients with unresolved toxicity of grade 3 or higher with availability of clinical (photographic) data, IIRS results obtained from skin biopsy assays, treatment modalities, and follow-up data. The RT technique and dosimetry were reviewed. Results: Our prospective registration of toxicities showed mainly rectitis, occurring in 7 cases, and skin toxicities, occurring in 9. Of the 7 patients with rectitis, 5 received 66 Gy of post-prostatectomy RT with V50 (rectum volume receiving 50 Gy) ranging from 45% to 75% and a mean maximal dose of 66.5 Gy. For dermatitis and cystitis, the mean maximal doses were in the range of classical constraints without any overdosage or dose heterogeneity. No errors were found in the review of treatment planning and positioning. Conversely, all the patients were considered biologically as radiosensitive with genomic instability and ATM (ataxia telangiectasia mutated)-dependent DNA double-strand break repair impairments. Conclusions: The MMR review of files allowed clear answers for patients on the relationship between clinical events and their IIRS. Our procedure has allowed education of all our staff to monitor, identify, and document clinical, physical, and biological aspects of radiation-induced toxicities. Thus we recommend the introduction of the MMR procedure in RT departments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dataset of solution-based inorganic materials synthesis procedures extracted from the scientific literature

The development of a materials synthesis route is usually based on heuristics and experience. A possible new approach would be to apply data-driven approaches to learn the patterns of synthesis from past experience and use them to predict the syntheses of novel materials. However, this route is impeded by the lack of a large-scale database of synthesis formulations. In this work, we applied advanced machine learning and natural language processing techniques to construct a dataset of 35,675 solution-based synthesis procedures extracted from the scientific literature. Each procedure contains essential synthesis information including the precursors and target materials, their quantities, and the synthesis actions and corresponding attributes. Every procedure is also augmented with the reaction formula. Through this work, we are making freely available the first large dataset of solution-based inorganic materials synthesis procedures.

36 MATERIALS SCIENCE↗

Entrance surface dose in cerebral interventional radiology procedures

At the Instituto Nacional de Neurologia y Neurocirugia (INNN) diagnostic as well as therapeutic procedures of interventional radiology are carried out. Since the procedures can last from some minutes to several hours, the absorbed dose for the patient could increase dangerously. An investigation had begun in order to determine the entrance surface dose (ESD) using 25 thermoluminiscent dosimeters TLD-100 and 8 strips of 15 Multiplication-Sign 1 cm{sup 2} of Gafchromic XR-QA2 film bound in a holder of 15 Multiplication-Sign 15 cm{sup 2} in the posteroanterior (PA) and lateral (LAT) positions during all the procedure. The results show that maximum ESD could be from 0.9 to 2.9 Gy for the PA position and between 1.6 and 2.5 Gy for the lateral position. The average ESD was between 0.7 and 1.3 Gy for the PA position, and from 0.44 to 1.1 Gy for the lateral position in a therapeutic procedure.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluating the performance of two neutron spectrum unfolding codes based on iterative procedures and artificial neural networks

In this work the performance of two neutron spectrum unfolding codes based on iterative procedures and artificial neural networks is evaluated. The first one code based on traditional iterative procedures and called Neutron spectrometry and dosimetry from the Universidad Autonoma de Zacatecas (NSDUAZ) use the SPUNIT iterative algorithm and was designed to unfold neutron spectrum and calculate 15 dosimetric quantities and 7 IAEA survey meters. The main feature of this code is the automated selection of the initial guess spectrum trough a compendium of neutron spectrum compiled by the IAEA. The second one code known as Neutron spectrometry and dosimetry with artificial neural networks (NDSann) is a code designed using neural nets technology. The artificial intelligence approach of neural net does not solve mathematical equations. By using the knowledge stored at synaptic weights on a neural net properly trained, the code is capable to unfold neutron spectrum and to simultaneously calculate 15 dosimetric quantities, needing as entrance data, only the rate counts measured with a Bonner spheres system. Similarities of both NSDUAZ and NSDann codes are: they follow the same easy and intuitive user's philosophy and were designed in a graphical interface under the LabVIEW programming environment. Both codes unfold the neutron spectrum expressed in 60 energy bins, calculate 15 dosimetric quantities and generate a full report in HTML format. Differences of these codes are: NSDUAZ code was designed using classical iterative approaches and needs an initial guess spectrum in order to initiate the iterative procedure. In NSDUAZ, a programming routine was designed to calculate 7 IAEA instrument survey meters using the fluence-dose conversion coefficients. NSDann code use artificial neural networks for solving the ill-conditioned equation system of neutron spectrometry problem through synaptic weights of a properly trained neural network. Contrary to iterative procedures, in neural net approach it is possible to reduce the rate counts used to unfold the neutron spectrum. To evaluate these codes a computer tool called Neutron Spectrometry and dosimetry computer tool was designed. The results obtained with this package are showed. The codes here mentioned are freely available upon request to the authors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Verification of the helioseismology travel-time measurement technique and the inversion procedure for sound speed using artificial data

We performed three-dimensional numerical simulations of the solar surface acoustic wave field for the quiet Sun and for three models with different localized sound-speed perturbations in the interior with deep, shallow, and two-layer structures. We used the simulated data generated by two solar acoustics codes that employ the same standard solar model as a background model, but utilize different integration techniques and different models of stochastic wave excitation. Acoustic travel times were measured using a time-distance helioseismology technique, and compared with predictions from ray theory frequently used for helioseismic travel-time inversions. It is found that the measured travel-time shifts agree well with the helioseismic theory for sound-speed perturbations, and for the measurement procedure with and without phase-speed filtering of the oscillation signals. This testing verifies the whole measuring-filtering-inversion procedure for static sound-speed anomalies with small amplitude inside the Sun outside regions of strong magnetic field. It is shown that the phase-speed filtering, frequently used to extract specific wave packets and improve the signal-to-noise ratio, does not introduce significant systematic errors. Results of the sound-speed inversion procedure show good agreement with the perturbation models in all cases. Due to its smoothing nature, the inversion procedure may overestimate sound-speed variations in regions with sharp gradients of the sound-speed profile.

79 ASTRONOMY AND ASTROPHYSICS↗

A Step-Down Test Procedure for Wavelet Shrinkage Using Bootstrapping

Wavelet thresholding (or shrinkage) attempts to remove the noises existing in the signals while preserving inherent pattern characteristics in the reconstruction of true signals. For data-denoising purpose, we present a new wavelet thresholding procedure which employs the step-down testing idea of identifying active contrasts in unreplicated fractional factorial experiments. The proposed method employs bootstrapping methods to a step-down test for thresholding wavelet coefficients. By introducing the concept of a false discovery error rate in testing wavelet coefficients, we shrink the wavelet coefficients with p -values higher than the error rate. The error rate controls the expected proportion of wrongly accepted coefficients among chosen wavelet coefficients. Bootstrap samples are used to approximate the p -value for computational efficiency. We also present some guidelines for selecting the values of hyper-parameters which affect the performance in the step-down thresholding procedure. Based on some common testing signals and an air-conditioner sounds example, the comparison of our proposed procedure with other thresholding methods in the literature is performed. The analytical results show that the proposed procedure has a potential in data-denoising and data-reduction in a variety of signal reconstruction applications.

42 ENGINEERING↗

Performance and Health Test Procedure for Grid Energy Storage Systems

A test procedure to evaluate the performance and health of field installations of grid-connected battery energy storage systems (BESS) is described. Performance and health metrics captured in the procedures are: round-trip efficiency, standby losses, response time/accuracy, and useable energy/state of charge at different discharge/charge rates over the system's lifetime. The procedures are divided into reference performance tests, which require the system to be put in a test mode and are to be conducted in intervals, and real-time monitoring tests, which collect data during normal operation without interruption. The procedures can be applied on a wide array of BESS with little modification and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditure. Simulated results based on a detailed system simulation of a prototype system are provided as guideline.

25 ENERGY STORAGE↗