Search NASA⌕ Search

SEARCH · Search NASA

Results for “program implementation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Performance Evaluation of the CHKED Multi-Elemental Analysis and Software

The Hybrid K-edge Densitometer (HKED) is a high precision safeguards assay system developed by Ottmar and Eberle [1] for quantification of the U and Pu concentrations of dissolver solutions in spent nuclear fuel reprocessing. The HKED measurement supplements traditional destructive assay methods such as Isotope Dilution Mass Spectrometry (IDMS) and is an essential component of the international safeguards program implementation at these facilities. The Canberra Hybrid K-Edge Densitometry (CHKED) software was recently developed by Canberra Industries to better address the changing composition of the nuclear fuel cycle by addition of a multi-elemental analysis capability to the K-Edge transmission measurement. Our evaluation of the CHKED software was performed at the request of the International Atomic Energy Agency (IAEA) to examine the functionality and performance of the CHKED software and algorithms and identify potential areas for improvement of the software. The reader is assumed to be familiar with the HKED technique and its current implementation in safeguards assay of U and Pu in the nuclear fuel cycle. The Canberra Hybrid K-Edge Densitometry CHKED software replicates functionality of the older VMSbased Hybrid K-Edge Densitometer (HKED) software and incorporates additional analysis algorithms and tools. When the traditional HKED analyses are selected, the CHKED software appears to faithfully reproduce the measurement results as reported by the older software. The CHKED software includes a Multi-elemental K-Edge (MEKED) analysis based in part on algorithms devised at Los Alamos National Laboratory. In principle, the MEKED analysis represents a significant advancement over the traditional HKED analysis, providing a capability to analyze the actinide concentrations from complex solutions, such as low U:Pu ratios (e.g., U:Pu = 1:1) including additional minor actinide components such as Np and Am. However, this MEKED analysis is somewhat limited by reliance on a region of interest (ROI) analysis of the spectrum, the need for extensive calibration measurements and a simplistic interpretation of the KED transmission spectrum. Finally, the MEKED algorithm set associated with the CHKED software (V1.0) acquired by Oak Ridge National Laboratory (ORNL) from Canberra Industries does not seem to be “finished” (e.g., the MEKED analysis seems to only determine measurement results for two actinides with while results for the minor actinides appear to be highly dependent on declaration values).

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

China Green Low-Carbon City Index

The main purpose of the new China Green Low-Carbon City Index (CGLCI, or City Index) is to evaluate the status of green and low-carbon development for a large number of Chinese cities. Chinese cities are formulating plans and implementing programs to address national initiatives, especially the national low-carbon pilot program for 36 cities and six provinces. However, there is not yet an established framework for measuring, reporting, or evaluating low-carbon progress across Chinese cities, despite the development of a number of Chinese and international city indicator systems. The new China City Index highlights energy use and carbon emissions of Chinese cities, along with environmental and socio-economic indicators. We selected metrics (indicators) that have data available in China’s statistical system, are commonly used internationally, and reflect Chinese policy goals. We then benchmarked and ranked Chinese cities in terms of their status and progress, identified potential areas for improvement, and identified top-runners.

54 ENVIRONMENTAL SCIENCES↗

Distributed Wind Resilience Metrics for Electric Energy Delivery Systems: Comprehensive Literature Review

While most people have a general concept of what it means to be “resilient,” an examination of definitions from different sources reveals that there are key commonalities but key differences as well. The lack of a generally accepted definition and application of resilience extends to electric energy delivery systems. Without an accepted definition, it is difficult to implement programs or processes to improve resiliency. In this paper, existing work from industry, regulatory bodies, and national laboratories to define and apply resilience to electric energy delivery systems is studied to understand the key components to define resilience and better understand associated metrics. This understanding is then applied to distributed wind for a specific example of how resilience of a system is affected by the technologies and generation sources used to support it. A key finding is that there is no “one size fits all” process for resilience. Each system has a “distinctiveness” characteristic, which qualifies the possibility of differences in resilience due to different threats, geography, stakeholders, risk tolerance, and mitigations. The distinctiveness characteristic extends to distributed wind, where different configurations may lend the distributed wind to contribute to the resilience of systems in a variety of ways. The findings of this research demonstrate the need for a resilience framework that can be readily applied by stakeholders to improve resilience based on the specific system, threat, risk tolerance and stakeholders.

17 WIND ENERGY↗

China Green Low-Carbon City Index: Report on the Performance of 100+ Cities (2010-2015)

The main purpose of the new China Green Low-Carbon City Index (CGLCI, or City Index ) is to evaluate the status of green and low-carbon development for a large number of Chinese cities. Chinese cities are formulating plans and implementing programs to address national initiatives, especially the national low-carbon pilot program for 36 cities and six provinces. However, there is not yet an established framework for measuring, reporting, or evaluating low-carbon progress across Chinese cities, despite the development of a number of Chinese and international city indicator systems. The new China City Index highlights energy use and carbon emissions of Chinese cities, along with environmental and socio-economic indicators. We selected metrics (indicators) that have data available in China’s statistical system, are commonly used internationally, and reflect Chinese policy goals. (See Table ES-1.) We then benchmarked and ranked Chinese cities in terms of their status and progress, identified potential areas for improvement, and identified top-runners. By “low-carbon” we mean reducing emissions of carbon dioxide (CO 2 ) and methane (CH 4 ), with a focus on energy-related CO 2 . The term “carbon” is used as short-hand for these GHGs throughout the report. By “green” we recognize multiple environmental parameters related to urbanization and climate change: air quality, water use, solid waste, transport networks, and urban green space. In early 2017, China expanded its low-carbon pilot cities program, adding 45 more cities.

54 ENVIRONMENTAL SCIENCES↗

Commercial Building Energy Code Field Study (Final Report)

What is the dollar value of increasing compliance with the energy code? Ultimately, this is the question that policy makers, funders, and program implementers care about. With this in mind, Pacific Northwest National Laboratory (PNNL) developed a new methodology capable of determining how much energy cost savings could potentially be gained through better compliance with the code (Rosenberg et al. 2016). On March 2, 2016 DOE issued Funding Opportunity Announcement (FOA) Number DE-FOA-0001532, requesting proposals to develop and test a methodology for identifying the commercial energy code requirements that can provide the maximum cost-effective energy and cost savings through increased compliance. Awarded to the Institute for Market Transformation, this report summarizes the development and testing of a commercial code compliance methodology, including a summary of results, statistical analysis of sample, and best practices for others implementing a commercial energy code compliance field study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing and benchmarking the fidelity of posterior inference methods for astrophysics data analysis

In this era of large and complex astronomical survey data, interpreting, validating, and comparing inference techniques becomes increasingly difficult. This is particularly critical for emerging inference methods like Simulation-Based Inference (SBI), which offer significant speedup potential and posterior modeling flexibility, especially when deep learning is incorporated. We present a study to assess and compare the performance and uncertainty prediction capability of Bayesian inference algorithms – from traditional MCMC sampling of analytic functions to deep learning-enabled SBI. We focus on testing the capacity of hierarchical inference modeling in those scenarios. Before we extend this study to cosmology, we first use astrophysical simulation data to ensure interpretability. We demonstrate a probabilistic programming implementation of hierarchical and non-hierarchical Bayesian inference using simulations derived from the DeepBench software library, a benchmarking tool developed by our group that generates simple and controllable astrophysical objects from first principles. This study will enable astronomers and physicists to harness the inference potential of these methods with confidence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electricity Subsector Transmission Resilience Maturity Model (TRMM) User Guide

The electric transmission sector is facing a range of threats to its functionality that are either new, more severe than experienced in earlier years, or more well understood. Such threats include more frequent and more severe extreme weather events, wildfires, droughts, and human-caused physical and cyberattacks. They also include geological, electromagnetic, and biological events. The novelty or increasing severity of these threats creates a significant need for transmission owners to implement programs to prevent, prepare for, respond to, and recover from such incidents. The national and economic security of the United States depends on the reliable functioning of the Nation’s critical infrastructure in the face of such threats, and the transmission networks are essential components of that infrastructure. The Electricity Subsector Transmission Resilience Maturity Model (TRMM) is a tool that a transmission organization can use to objectively evaluate and benchmark its currently established transmission resilience strategies, programs, policies, and investments, in order to target and prioritize enhancements where needed. The TRMM was developed to address the unique characteristics of the transmission system. The model can enable users to: • evaluate and benchmark their organization’s resilience capabilities, effectively and consistently • prioritize actions and investments to improve the resilience of their systems • share transmission-related knowledge, best practices, and relevant references within their organization and with business partners as a means to improve resilience capabilities • contribute to increasing the overall resilience of the Nation’s transmission systems. The TRMM provides descriptive rather than prescriptive industry-focused guidance. The model content is presented at a high level of abstraction so that it can be interpreted by transmission organizations of various types, structures, and sizes. The model is designed to an be easy-to-use, self-assessment tool.

24 POWER TRANSMISSION AND DISTRIBUTION↗

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION↗

The NASA System Safety Program

NASA aerospace system safety program implementation and supporting organization with emphasis on background, concepts, constraints, methods and results

Harris, R. E.↗

Space station design

Space station design, discussing existing technology base for earth orbital operations program implementation

Berglund, R. A.↗

CIRCAL-2 - General-purpose on-line circuit design.

CIRCAL-2 is a second-generation general-purpose on-line circuit-design program with the following main features: (1) multiple-analysis capability; (2) uniform and general data structures for handling text editing, network representations, and output results, regardless of analysis; (3) special techniques and structures for minimizing and controlling user-program interaction; (4) use of functionals for the description of hysteresis and heat effects; and (5) ability to define optimization procedures that 'replace' the user. The paper discusses the organization of CIRCAL-2, the aforementioned main features, and their consequences, such as a set of network elements and models general enough for most analyses and a set of functions tailored to circuit-design requirements. The presentation is descriptive, concentrating on conceptual rather than on program implementation details.

Dertouzos, M. L.↗

Dynamic verification of a digital flight control system.

Development of a digital control system dynamic variation technique which accounts for the limitation of available frequency response analyzers. Digital control system theory is briefly reviewed, and generation of the necessary theoretical frequency responses is discussed. Results of the dynamic verification of a digital control system for a Saturn V launch vehicle are presented, and attention is given to the limitations of this technique along with its applicability to other types of digital control systems. A technique for performing open-loop frequency response analyses of a flight program implemented in a 'flight-type' digital computer and interface hardware with vehicle dynamics simulated on an analog computer is described.

Nabers, J. P., Jr.↗

Evaluation of human operator visual performance capability for teleoperator missions.

Investigation of the human operator visual performance demands of teleoperator system applications to earth-orbital missions involving visual system requirements for satellite retrieval and satellite servicing functions. The first phase of an experimental program implementing this investigation is described in terms of the overall test apparatus and procedures used, the specific tests performed, and the test results obtained.

Huggins, C. T.↗

Medical operations: Crew surgeon's report

To assure the safety and well being of the Skylab environment simulation crewmembers it was necessary to develop a medical safety plan with emergency procedures. All medical and nonmedical test and operations personnel, except those specifically exempted, were required to meet the medical standards and proficiency levels as established. Implemented programs included health care of the test crew and their families, occupational medical services for chamber operating personnel, clinical laboratory support and hypobaric and other emergency support.

Ross, C. E.↗

Reliability model derivation of a fault-tolerant, dual, spare-switching, digital computer system

A computer based reliability projection aid, tailored specifically for application in the design of fault-tolerant computer systems, is described. Its more pronounced characteristics include the facility for modeling systems with two distinct operational modes, measuring the effect of both permanent and transient faults, and calculating conditional system coverage factors. The underlying conceptual principles, mathematical models, and computer program implementation are presented.

Source record↗

Safety management of a complex R&D ground operating system

Report discusses safety program implementation for large R&D operating system. Analytical techniques are defined and suggested as tools for identifying potential hazards and determining means to effectively control or eliminate hazards.

Connors, J.↗