Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantitative analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Quantitative Analysis of the Nucleation and Growth of Ferroelectric Domains in Epitaxial Pb(Zr,Ti)O3 Thin Films

We determined simultaneously the domain wall speed (v) and the nucleation rate (N) of ferroelectric (FE) domain in 100-nm-thick epitaxial PbZr{sub 0.2}Ti{sub 0.8}O{sub 3} capacitors from the successive domain evolution images under various applied electric field (E{sub app}) by piezoresponse force microscopy. It was found that, at a given electric field, the v and N values decreased as the switching process proceeded. The averaged domain wall speed <v> was confirmed to follow the Merz's law, <v>exp[-(E{sub 0}/E{sub app})], with an activation field E{sub 0} of about 700 kV/cm. Moreover, we found that the nucleation process played a more important role in the FE domain switching at higher fields, while domain wall motion mainly contributed to the switching at lower fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantitative analysis of supported membrane composition using the NanoSIMS

We have improved methods reported earlier [1] for sample preparation, imaging and quantifying components in supported lipid bilayers using high-resolution secondary ion mass spectrometry performed with the NanoSIMS 50. By selectively incorporating a unique stable isotope into each component of interest, a component-specific image is generated from the location and intensity of the unique secondary ion signals exclusively produced by each molecule. Homogeneous supported lipid bilayers that systematically varied in their isotopic enrichment levels were freeze-dried and analyzed with the NanoSIMS 50. The molecule-specific secondary ion signal intensities had an excellent linear correlation to the isotopically labeled lipid content. Statistically indistinguishable calibration curves were obtained using different sample sets analyzed months apart. Fluid bilayers can be patterned using lithographic methods and the composition of each corralled region varied systematically by simple microfluidic methods. The resulting composition variations can be imaged and quantified. This approach opens the possibility of imaging and quantifying the composition of microdomains within membranes, including protein components, without using bulky labels and with very high lateral resolution and sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Point Defect Characterization in HAADF-STEM Images Using Multivariate Statistical Analysis

Quantitative analysis of point defects is demonstrated through the use of multivariate statistical analysis. This analysis consists of principal component analysis for dimensional estimation and reduction, followed by independent component analysis to obtain physically meaningful, statistically independent factor images. Results from these analyses are presented in the form of factor images and scores. Factor images show characteristic intensity variations corresponding to physical structure changes, while scores relate how much those variations are present in the original data. The application of this technique is demonstrated on a set of experimental images of dislocation cores along a low-angle tilt grain boundary in strontium titanate. A relationship between chemical composition and lattice strain is highlighted in the analysis results, with picometer-scale shifts in several columns measurable from compositional changes in a separate column.

99 GENERAL AND MISCELLANEOUS↗

Aquarium Shot Image Analysis

Quantitative analysis of fast-frame imagery of explosive aquarium shots can extract an abundance of information regarding the evolution of both the shock and the product gases following the passage of a detonation front. Analysis of the product gases (or any other surface of interest that lies within the shock and is observed from outside of the shock) is complicated by the fact that the water shock refracts the light in all three dimensions. This makes it necessary to correct for this refraction in order to get an accurate perception of the location of the surface and subsequently the velocities derived from the shape of that surface.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The existence of amorphous phase in Portland cements: Physical factors affecting Rietveld quantitative phase analysis

Rietveld quantitative phase analysis has become a widespread tool for the characterization of Portland cement, both for research and production control purposes. One of the major remaining points of debate is whether Portland cements contain amorphous content or not. This paper presents detailed analyses of the amorphous phase contents in a set of commercial Portland cements, clinker, synthetic alite and limestone by Rietveld refinement of X-ray powder diffraction measurements using both external and internal standard methods. A systematic study showed that the sample preparation and comminution procedure is closely linked to the calculated amorphous contents. Particle size reduction by wet-grinding lowered the calculated amorphous contents to insignificant quantities for all materials studied. No amorphous content was identified in the final analysis of the Portland cements under investigation.

36 MATERIALS SCIENCE↗

Risk Assessment and Management Workflow—An Example of the Southwest Regional Partnership

This paper summarizes the risk assessment and management workflow developed and applied to the Southwest Regional Partnership on Carbon Sequestration (SWP) Phase III Demonstration Project. The risk assessment and management workflow consists of six primary tasks, including management planning, identification, qualitative analysis, quantitative analysis, response planning, and monitoring. Within the workflow, the SWP assembled and iteratively updated a risk registry that identifies risks for all major activities of the project. Risk elements were ranked with respect to the potential impact to the project and the likelihood of occurrence. Both qualitative and quantitative risk analyses were performed. To graphically depict the interactions among risk elements and help building risk scenarios, process influence diagrams were used to represent the interactions. The SWP employed quantitative methods of risk analysis including Response Surface Method (RSM), Polynomial Chaos Expansion (PCE), and the National Risk Assessment Partnership (NRAP) toolset. The SWP also developed risk response planning and performed risk control and monitoring to prevent the risks from affecting the project and ensure the effectiveness of risk management. As part of risk control and monitoring, existing and new risks have been tracked and the response plan was subsequently evaluated. Findings and lessons learned from the SWP’s risk assessment and management efforts will provide valuable information for other commercial geological CO2 storage projects.

Lee, Si-Yong↗

High-Resolution Mass Spectrometry Quantification: Impact of Differences in Data Processing of Centroid and Continuum Data

High-resolution mass spectrometry (HRMS) in full scan mode acquires all ions present in the sample of interest offering a lot of qualitative information. This, in combination with the improved performance of the new generation HRMS systems, triggers more (bio) analysts to switch from triple quad MS systems to HRMS for quantitative analysis. Quantitative processing of HRMS data is performed based on narrow mass extraction windows rather than on nominal mass product ion chromatograms (SRM or MRM). Optimal processing of HRMS data requires different considerations and software tools and can have an impact on data processing and final results. The selection of centroid versus continuum/profile data for processing, selection of the optimal narrow mass extraction window, using theoretical versus measured accurate mass for the extraction of the ion chromatograms as well as differences in calculations and data handling residing in the different vendor software packages are tackled in the presented manuscript. These differences are illustrated on HRMS data acquired for the same plasma samples on three different platforms, i.e., a Sciex QToF, a Waters QToF, and a Thermo Orbitrap system, and processed in four different software packages, i.e., Sciex Analyst® TF, Waters Masslynx, Waters Unifi, and Thermo Xcalibur. The impact of these differences on quantitative HRMS performance was evaluated on calibration curves of eight small molecule compounds in plasma using four different ways of processing. Simple guidelines are provided for the selection of an optimal mass extraction window for continuum and centroided data. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative resilience analysis through control design.

Critical infrastructure resilience has become a national priority for the U. S. Department of Homeland Security. System resilience has been studied for several decades in many different disciplines, but no standards or unifying methods exist for critical infrastructure resilience analysis. Few quantitative resilience methods exist, and those existing approaches tend to be rather simplistic and, hence, not capable of sufficiently assessing all aspects of critical infrastructure resilience. This report documents the results of a late-start Laboratory Directed Research and Development (LDRD) project that investigated the development of quantitative resilience through application of control design methods. Specifically, we conducted a survey of infrastructure models to assess what types of control design might be applicable for critical infrastructure resilience assessment. As a result of this survey, we developed a decision process that directs the resilience analyst to the control method that is most likely applicable to the system under consideration. Furthermore, we developed optimal control strategies for two sets of representative infrastructure systems to demonstrate how control methods could be used to assess the resilience of the systems to catastrophic disruptions. We present recommendations for future work to continue the development of quantitative resilience analysis methods.

42 ENGINEERING↗

Addressing the Amorphous Content Issue in Quantitative Phase Analysis: The Certification of NIST Standard Reference Material 676a

A non-diffracting surface layer exists at any boundary of a crystal and can comprise a mass fraction of several percent in a finely divided solid. This has led to the long-standing issue of amorphous content in standards for quantitative phase analysis (QPA). NIST standard reference material (SRM) 676a is a corundum ({alpha}-Al{sub 2}O{sub 3}) powder, certified with respect to phase purity for use as an internal standard in powder diffraction QPA. The amorphous content of SRM 676a is determined by comparing diffraction data from mixtures with samples of silicon powders that were engineered to vary their specific surface area. Under the (supported) assumption that the thickness of an amorphous surface layer on Si was invariant, this provided a method to control the crystalline/amorphous ratio of the silicon components of 50/50 weight mixtures of SRM 676a with silicon. Powder diffraction experiments utilizing neutron time-of-flight and 25 keV and 67 keV X-ray energies quantified the crystalline phase fractions from a series of specimens. Results from Rietveld analyses, which included a model for extinction effects in the silicon, of these data were extrapolated to the limit of zero amorphous content of the Si powder. The certified phase purity of SRM 676a is 99.02% {+-} 1.11% (95% confidence interval). This novel certification method permits quantification of amorphous content for any sample of interest, by spiking with SRM 676a.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diffraction Methods for Qualitative and Quantitative Texture Analysis of Ferroelectric Ceramics

Crystallographic textures are pervasive in ferroelectrics and underpin the functional properties of devices utilizing these materials because many macroscopic properties (e.g., piezoelectricity) require a non-random distribution of dipoles. Inducing a preferred grain texture has become a viable route to improve these functional properties. X-ray and neutron diffraction have become valuable tools to probe crystallographic textures. This paper presents an overview of qualitative and quantitative methods for assessing crystallographic textures in electroceramics (domain and grain textures) and discusses their strengths and weaknesses.

36 MATERIALS SCIENCE↗

Note: Alignment/focus dependent core-line sensitivity for quantitative chemical analysis in hard x-ray photoelectron spectroscopy using a hemispherical electron analyzer

X-ray photoelectron spectroscopy is an established technique for quantitative chemical analysis requiring accurate peak intensity analysis. We present evidence of focus/alignment dependence of relative peak intensities for peaks over a broad kinetic energy range with a hemispherical electron analyzer operated in a position imaging mode. A decrease of over 50% in the Ag 2p{sub 3/2} to Ag 3d ratio is observed in a Ag specimen. No focus/alignment dependence is observed when using an angular imaging mode, necessitating the use of angular mode for quantitative chemical analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Introductory guide to backgrounds in XPS spectra and their impact on determining peak intensities

Photoelectron and Auger peaks are central to most of the important uses of x-ray photoelectron spectroscopy (XPS), and thus, they receive the most attention in many types of analysis. Quantitative chemical analysis using XPS requires the assessment of the intensities of the photoemission peaks of the elements detected. Determination of peak intensities requires separation of the photoelectron peak signals from the background on which the peaks rest. For the determination of peak area intensities, the background is subtracted from overall signal intensity. The spectral background is also critical when peak fitting is used to determine intensities of overlapping peaks, and the model of background used in this process can impact the results. In addition to the impact on quantitative analysis, information about the depth distribution of elements in the near surface region can often be obtained by visual inspection of the background and quantified using appropriate modeling. Here, this introductory guide provides some basic information about backgrounds in the XPS analysis, describes the types of background models that are commonly used, suggests some of their strengths and weaknesses, and provides examples of their use and misuse. Although the fundamental nature of some components of the background signals in XPS is not understood, indicating that none of the models in use are fully correct and the area is subject to active research, appropriate good practices have been established for most routine analysis. The guide describes good practices, identifies errors that frequently appear in the literature, and uses examples to demonstrate the impacts of background selections on determinations of peak intensities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Potential Chemical Impacts of CO2 Leakage on Underground Source of Drinking Water Assessed by Quantitative Risk Analysis

Many geologic carbon storage site options include not only excellent storage reservoirs bounded by effective seal layers, but also Underground Sources of Drinking Water (USDWs). An effective risk assessment and mitigation plan provides maximum protection for USDWs, to respect not only current policy but also to accommodate likely future USDW-specific regulatory protections. The goal of this study is to quantify possible risks to USDWs, specifically risks associated with chemical impacts on USDWs. Reactive transport models involve tremendous computational expense. Therefore, a secondary purpose of this study is to develop, calibrate and test reduced order models specifically for assessing risks of USDW chemical impacts by CO2 leakage from a storage reservoir. In order to achieve these goals, a geochemical model was developed to interpret changes in water chemistry following CO2 intrusion. A response surface methodology (RSM) based on these geochemical simulations was used to quantify associated risks. The case study example for this analysis is the Ogallala aquifer overlying the Farnsworth unit (FWU), an active commercial-scale CO2-enhanced oil recovery field. Specific objectives of this study include: (1) to understand how CO2 leakage is likely to influence geochemical processes in aquifer sediments; (2) to quantify potential risks to the Ogallala groundwater aquifer due to CO2 leakage from the FWU oil reservoir; and (3) to identify water chemistry factors for early detection criteria. Results indicate that the leakage rate would most likely range between 10-14 – 10-10 kg/(m2·year) for typical and likely leakage pathway permeability ranges. Within this range of CO2 leakage rate, groundwater quality is not likely to be significantly impacted. The worst-case scenario yields trace metal concentrations approximately twice as much as the initial value, but these predicted concentrations are still less than one-fifth of regulation-stipulated maximum contamination levels and do not exceed the no-impact thresholds. Finally, the results of this analysis suggest that pH may be an effective geochemical indicator of CO2 leakage.

CO2 leakage, USDWs, Groundwater quality, Risk anal↗

Quantitative proteomics analysis of adsorbed plasma proteins classifies nanoparticles with different surface properties and size

In biofluids (e.g., blood plasma) nanoparticles are readily embedded in layers of proteins that can affect their biological activity and biocompatibility. Herein, we report a study on the interactions between human plasma proteins and nanoparticles with a controlled systematic variation of properties using stable isotope labeling and liquid chromatography-mass spectrometry (LC-MS) based quantitative proteomics. Novel protocol has been developed to simplify the isolation of nanoparticle bound proteins and improve the reproducibility. Plasma proteins associated with polystyrene nanoparticles with three different surface chemistries and two sizes as well as for four different exposure times (for a total of 24 different samples) were identified and quantified by LC-MS analysis. Quantitative comparison of relative protein abundances were achieved by spiking an 18 O-labeled 'universal reference' into each individually processed unlabeled sample as an internal standard, enabling simultaneous application of both label-free and isotopic labeling quantitation across the sample set. Clustering analysis of the quantitative proteomics data resulted in distinctive pattern that classifies the nanoparticles based on their surface properties and size. In addition, data on the temporal study indicated that the stable protein 'corona' that was isolated for the quantitative analysis appeared to be formed in less than 5 minutes. The comprehensive results obtained herein using quantitative proteomics have potential implications towards predicting nanoparticle biocompatibility.

18 O labeling↗

Powder diffraction

Powder diffraction is a non-destructive technique, which is experimentally simple in principle. Because the physics behind diffraction is well understood, an exceptionally large amount of information can be obtained from a single measurement. The positions and relative intensities of the peaks yield a fingerprint that can be used for qualitative phase analysis. Quantitative phase analysis can be obtained by detailed analysis of the intensities. Unit cells can be derived from the peak positions. Crystal structures can be solved using powder diffraction data and refined by the Rietveld method. The peak profiles contain information about crystallite size, strain and nanostructure. Non-idealities in the intensities give information on texture. Abandoning the crystallographic model provides information about local structure, by pair distribution function analysis. For powder diffraction, everything is a sample; the technique is commonly applied to characterize minerals, ceramics, metals and alloys, catalysts, polymers, pharmaceuticals, organic compounds, environmental and forensic samples, among others. The major features of contemporary laboratory powder diffractometers are described. Methods for obtaining suitable powder specimens are summarized. Major applications of qualitative and quantitative phase analysis, structure solution, size/strain/nanostructure analysis using peak profiles, texture analysis and pair distribution function analysis are introduced.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantitative compositional analysis and strain study of InAs quantum wires with InGaAlAs barrier layers

Quantitative compositional analysis of InAs quantum wires deposited between In{sub 0.53}Ga{sub 0.37}Al{sub 0.1}As barrier layers grown on InP substrates was performed by electron energy loss spectrometry and energy dispersive x-ray spectrometry. An indium-rich region in the center of the wire, with decreasing indium concentration toward the interface with the barrier layers, was observed from indium concentration maps for individual quantum wires. 'Stripelike' contrast modulation was observed in diffraction contrast transmission electron microscope images of the In{sub 0.53}Ga{sub 0.37}Al{sub 0.1}As barrier layer immediately above the quantum wires. The contrast originated from indium compositional modulations in the upper barrier layer as confirmed by electron energy loss spectrometry and the modulation is attributed to the presence of an inhomogeneous elastic strain field generated by the buried quantum wires. These results suggest that quantitative analysis of the composition and strain distributions at very high spatial resolution provides insights necessary to further model the physical properties and to understand the growth of these nanostructures.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Toward quantitative deuterium analysis with laser-induced breakdown spectroscopy using atmospheric-pressure helium gas

An experimental study has been carried out for the development of quantitative deuterium analysis using the neodymium doped yttrium aluminum garnet laser-induced breakdown spectroscopy (LIBS) with atmospheric pressure surrounding He gas by exploring the appropriate experimental condition and special sample cleaning technique. The result demonstrates the achievement of a full resolution between the D and H emission lines from zircaloy-4 samples, which is prerequisite for the desired quantitative analysis. Further, a linear calibration line with zero intercept was obtained for the emission intensity of deuterium from a number of zircaloy samples doped with predetermined concentrations of deuterium. The result is obtained by setting a +4 mm defocusing position for the laser beam, 6 {mu}s detection gating time, and 7 mm imaging position of the plasma for the detection, which is combined with a special procedure of repeated laser cleaning of the samples. This study has thus provided the basis for the development of practical quantitative deuterium analysis by LIBS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗