Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantitative phase imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Scalable method for micro-CT analysis enables large scale quantitative characterization of brain lesions and implants

Anatomic evaluation is an important aspect of many studies in neuroscience; however, it often lacks information about the three-dimensional structure of the brain. Micro-CT imaging provides an excellent, nondestructive, method for the evaluation of brain structure, but current applications to neurophysiological or lesion studies require removal of the skull as well as hazardous chemicals, dehydration, or embedding, limiting their scalability and utility. Here we present a protocol using eosin in combination with bone decalcification to enhance contrast in the tissue and then employ monochromatic and propagation phase-contrast micro-CT imaging to enable the imaging of brain structure with the preservation of the surrounding skull. Instead of relying on descriptive, time-consuming, or subjective methods, we develop simple quantitative analyses to map the locations of recording electrodes and to characterize the presence and extent of hippocampal brain lesions.

3-D reconstruction↗

Denoised Wigner distribution deconvolution via low-rank matrix completion

Wigner distribution deconvolution (WDD) is a decades-old method for recovering phase from intensity measurements. Although the technique offers an elegant linear solution to the quadratic phase retrieval problem, it has seen limited adoption due to its high computational/memory requirements and the fact that the technique often exhibits high noise sensitivity. Here, we propose a method for noise suppression in WDD via low-rank noisy matrix completion. Our technique exploits the redundancy of an object’s phase space to denoise its WDD reconstruction. We show in model calculations that our technique outperforms other WDD algorithms as well as modern iterative methods for phase retrieval such as ptychography. Here, our results suggest that a class of phase retrieval techniques relying on regularized direct inversion of ptychographic datasets (instead of iterative reconstruction techniques) can provide accurate quantitative phase information in the presence of high levels of noise.

47 OTHER INSTRUMENTATION↗

Understanding Fission Gas Bubble Distribution and Zirconium Redistribution in Neutron-irradiated U-Zr Metallic Fuel Using Machine Learning

U-10wt.% Zr (U-10Zr) based metallic fuel is the leading candidate for next-generation sodium cooled fast reactor in United States. Currently, Idaho National Laboratory (INL) has been the leading national laboratory for research, development, and demonstration (RD&D) on metallic fuel. Advanced post-irradiation characterization will help to understand fuel microstructure and property change during irradiation, benefiting fuel qualification for commercial application. Characterization capabilities ranging from sub-nanometer to micrometer, such as scanning electron microscopy (SEM), focused ion beam (FIB) sampling, transmission electron microscopy (TEM) characterization, and local thermal conductivity microscopy (TCM), have been utilized recently on irradiated U-10Zr fuel samples to gain a better understanding of nuclear fuel microstructure and property evolution inside a reactor. The FIB/SEM coupled with energy dispersive X-ray spectroscopy (EDS) can capture the essential information to achieve better understanding of fuel behaviors. Inside a nuclear reactor, the phase and microstructure of U-10Zr is constantly changing under neutron bombardment. For example, the gaseous fission product atoms have a limited solubility inside fuel matrix and tend to precipitate out in bubble form, which not only contribute to fuel thermal conductivity degradation but also provide a shortcut for movement of fission products, i.e. lanthanides. The resultant deposition of lanthanides at the cladding inner surface will potentially trigger a chemical reaction/interaction between nuclear fuel and cladding at reactor operational conditions, threatening fuel integrity and safety. FIB/SEM coupled with EDS can provide the fission bubble information as well as probe into phase separation or Zr redistribution, which is fundamental to predict the fuel performance. With high velocity image data generating method, such as FIB/SEM, an automatic way to extract the microstructural information quantitively can better serve the needs from post irradiation characterization. A trained machine learning model, named Decision Tree, is employed to generate a bubble classifier and to categorize bubbles into three categories: isolated bubble, connected without lanthanides, and connected with lanthanides bubbles[3]. This work presents a showcase of this approach on six regions of a fuel cross-section along the radial temperature gradient. We obtained distributions of bubble categories and porosity rates along the six regions. Moreover, a secondary phase U-Zr2 was determined and found on regions 5 and 6. The secondary phase fraction was increasing from 15.61% in region 5 to 34.79% in region 6 based on this approach . This quantitative data offers insights into the lanthanide migration and potentially thermal conductivity degradation. This information from machine learning will be fed into fuel design code for better prediction of fuel performance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Resolving High Amplitude Surface Motion with Diffusing Light

A new technique has been developed for the purpose of imaging high amplitude surface motion. With this method one can quantitatively measure the transition to ripple wave turbulence. In addition, one can measure the phase of the turbulent state. These experiments reveal strong coherent structures in turbulent range of motion.

Wright, W.↗

Actinic characterization of EUV bump-type phase defects

Despite tremendous progress and learning with EUV lithography, quantitative experimental information about the severity of point-like phase defects remains in short supply. We present a study of measured, EUV aerial images from a series of well-characterized, open-field, bump-type programmed phase defects, created on a substrate before multilayer deposition.

36 MATERIALS SCIENCE↗

A general theory of interference fringes in x-ray phase grating imaging

Purpose: The authors note that the concept of the Talbot self-image distance in x-ray phase grating interferometry is indeed not well defined for polychromatic x-rays, because both the grating phase shift and the fractional Talbot distances are all x-ray wavelength-dependent. For x-ray interferometry optimization, there is a need for a quantitative theory that is able to predict if a good intensity modulation is attainable at a given grating-to-detector distance. In this work, the authors set out to meet this need. Methods: In order to apply Fourier analysis directly to the intensity fringe patterns of two-dimensional and one-dimensional phase grating interferometers, the authors start their derivation from a general phase space theory of x-ray phase-contrast imaging. Unlike previous Fourier analyses, the authors evolved the Wigner distribution to obtain closed-form expressions of the Fourier coefficients of the intensity fringes for any grating-to-detector distance, even if it is not a fractional Talbot distance. Results: The developed theory determines the visibility of any diffraction order as a function of the grating-to-detector distance, the phase shift of the grating, and the x-ray spectrum. The authors demonstrate that the visibilities of diffraction orders can serve as the indicators of the underlying interference intensity modulation. Applying the theory to the conventional and inverse geometry configurations of single-grating interferometers, the authors demonstrated that the proposed theory provides a quantitative tool for the grating interferometer optimization with or without the Talbot-distance constraints. Conclusions: In this work, the authors developed a novel theory of the interference intensity fringes in phase grating x-ray interferometry. This theory provides a quantitative tool in design optimization of phase grating x-ray interferometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deep Learning Automates the Quantitative Analysis of Individual Cells in Live-Cell Imaging Experiments

Live-cell imaging has opened an exciting window into the role cellular heterogeneity plays in dynamic, living systems. A major critical challenge for this class of experiments is the problem of image segmentation, or determining which parts of a microscope image correspond to which individual cells. Current approaches require many hours of manual curation and depend on approaches that are difficult to share between labs. They are also unable to robustly segment the cytoplasms of mammalian cells. Here, we show that deep convolutional neural networks, a supervised machine learning method, can solve this challenge for multiple cell types across the domains of life. We demonstrate that this approach can robustly segment fluorescent images of cell nuclei as well as phase images of the cytoplasms of individual bacterial and mammalian cells from phase contrast images without the need for a fluorescent cytoplasmic marker. These networks also enable the simultaneous segmentation and identification of different mammalian cell types grown in co-culture. A quantitative comparison with prior methods demonstrates that convolutional neural networks have improved accuracy and lead to a significant reduction in curation time. We relay our experience in designing and optimizing deep convolutional neural networks for this task and outline several design rules that we found led to robust performance. We conclude that deep convolutional neural networks are an accurate method that require less curation time, are generalizable to a multiplicity of cell types, from bacteria to mammalian cells, and expand live-cell imaging capabilities to include multi-cell type systems.

59 BASIC BIOLOGICAL SCIENCES↗

Self-supervised physics-informed generative networks for phase retrieval from a single X-ray hologram

X-ray phase contrast imaging significantly improves the visualization of structures with weak or uniform absorption, broadening its applications across a wide range of scientific disciplines. Propagation-based phase contrast is particularly suitable for time- or dose-critical in vivo/in situ/operando (tomography) experiments because it requires only a single intensity measurement. However, the phase information of the wave field is lost during the measurement and must be recovered. Conventional algebraic and iterative methods often rely on specific approximations or boundary conditions that may not be met by many samples or experimental setups. In addition, they require manual tuning of reconstruction parameters by experts, making them less adaptable for complex or variable conditions. Here we present a self-learning approach for solving the inverse problem of phase retrieval in the near-field regime of Fresnel theory using a single intensity measurement (hologram). A physics-informed generative adversarial network is employed to reconstruct both the phase and absorbance of the unpropagated wave field in the sample plane from a single hologram. Unlike most state-of-the-art deep learning approaches for phase retrieval, our approach does not require paired, unpaired, or simulated training data. This significantly broadens the applicability of our approach, as acquiring or generating suitable training data remains a major challenge due to the wide variability in sample types and experimental configurations. The algorithm demonstrates robust and consistent performance across diverse imaging conditions and sample types, delivering quantitative, high-quality reconstructions for both simulated data and experimental datasets acquired at beamline P05 at PETRA III (DESY, Hamburg), operated by Helmholtz-Zentrum Hereon. Furthermore, it enables the simultaneous retrieval of both phase and absorption information.

36 MATERIALS SCIENCE↗

SU-E-J-260: Quantitative Image Feature Analysis of Multiphase Liver CT for Hepatocellular Carcinoma (HCC) in Radiation Therapy

Purpose: To identify the effective quantitative image features (radiomics features) for prediction of response, survival, recurrence and metastasis of hepatocellular carcinoma (HCC) in radiotherapy. Methods: Multiphase contrast enhanced liver CT images were acquired in 16 patients with HCC on pre and post radiation therapy (RT). In this study, arterial phase CT images were selected to analyze the effectiveness of image features for the prediction of treatment outcome of HCC to RT. Response evaluated by RECIST criteria, survival, local recurrence (LR), distant metastasis (DM) and liver metastasis (LM) were examined. A radiation oncologist manually delineated the tumor and normal liver on pre and post CT scans, respectively. Quantitative image features were extracted to characterize the intensity distribution (n=8), spatial patterns (texture, n=36), and shape (n=16) of the tumor and liver, respectively. Moreover, differences between pre and post image features were calculated (n=120). A total of 360 features were extracted and then analyzed by unpaired student’s t-test to rank the effectiveness of features for the prediction of response. Results: The five most effective features were selected for prediction of each outcome. Significant predictors for tumor response and survival are changes in tumor shape (Second Major Axes Length, p= 0.002; Eccentricity, p=0.0002), for LR, liver texture (Standard Deviation (SD) of High Grey Level Run Emphasis and SD of Entropy, both p=0.005) on pre and post CT images, for DM, tumor texture (SD of Entropy, p=0.01) on pre CT image and for LM, liver (Mean of Cluster Shade, p=0.004) and tumor texture (SD of Entropy, p=0.006) on pre CT image. Intensity distribution features were not significant (p>0.09). Conclusion: Quantitative CT image features were found to be potential predictors of the five endpoints of HCC in RT. This work was supported in part by the National Cancer Institute Grant R01CA172638.

60 APPLIED LIFE SCIENCES↗

Secondary carbides in high chromium cast irons: An alternative approach to their morphological and spatial distribution characterization

Highlights: • Systematic characterization of second phase particles by combining a variety of techniques • Comparison of morphological parameters obtained from SEM, BSE, etching+CLSM and EBSD • Quantitative analysis and degree of distribution of secondary carbides • Particle size, distribution and morphology from image analysis of CLSM, SEM and EBS images - Abstract: Secondary carbides precipitated in high chromium cast irons during thermal treatments were characterized by means of different characterization techniques, including scanning electron microscopy, energy dispersive X-ray spectroscopy, electron backscattered diffraction and a combination of chemical etching with confocal scanning laser microscopy. This set of techniques provides a full morphological, chemical and crystallographic description of the analysed phases. This work evaluated different methods for optimizing the image acquisition for a further image analysis (IA) based on the threshold binarization. Finally, the carbide size, distribution and morphology were determined after IA of the images acquired by aforementioned characterization techniques. Although the different techniques report some dispersion in the value for the average particle size, the particle inter-spacing and aspect ratio meet within the error value. The proposed characterization methodology provides statistically reliable data for a further evaluation of related physical properties in composites.

36 MATERIALS SCIENCE↗

Characterizing the microstructures of mammalian enamel by synchrotron phase contrast microCT

The enamel of mammalian teeth is a highly mineralized tissue that must endure a lifetime of cyclic contact and is inspiring the development of next-generation engineering materials. Attempts to implement enamel-inspired structures in synthetic materials have had limited success, largely due to the absence of a detailed understanding of its microstructure. Here, the present work used synchrotron phase-contrast microCT imaging to evaluate the three-dimensional microstructure of enamel from four mammals including Lion, Gray Wolf, Snow Leopard, and Black Bear. Quantitative results of image analysis revealed that the decussation pattern of enamel consists of discrete diazone (D) and parazone (P) bands of rods organized with stacking arrangement of D+/P/D-/P in all mammals evaluated; the D+ and D- refer to distinct diazone bands with juxtaposed rod orientations from the reference plane. Furthermore, the rod orientations in the bands can be described in terms of two principal angles, defined here as the pitch and yaw. While the pitch angle increases from the outer enamel to a maximum (up to ≈ 40°) near the dentin enamel junction, minimal spatial variations are observed in yaw across the enamel thickness. There are clear differences in the decussation parameters of enamel across species that are interpreted here with respect to the structural demands placed on their teeth. The rod pitch and band width of enamel are identified as important design parameters and appear to be correlated with the bite force quotient of the four mammals evaluated.

36 MATERIALS SCIENCE↗

SU-F-BRE-16: VMAT Commissioning and Quality Assurance (QA) of An Elekta Synergy-STM Linac Using ICOM Test HarnessTM

Purpose: To establish a set of tests based on the iCOM software that can be used to commission and perform periodic QA of VMAT delivery on the Elekta Synergy-S, commonly known as the Beam Modulator (BM). Methods: iCOM is used to create and deliver customized treatment fields to characterize the system in terms of 1) MLC positioning accuracy under static and dynamic delivery with full gantry rotation, 2) MLC positioning with known errors, 3) Maximum dose rate, 4) Maximum MLC speed, 5) Maximum gantry speed, 6) Synchronization: gantry speed versus dose rate, and 7) Synchronization: MLC speed versus dose rate. The resulting images were captured on the iView GT and exported in DICOM format to Dosimetry Check™ system for visual and quantitative analysis. For the initial commissioning phase, the system tests described should be supplemented with extensive patient QAs covering all clinically relevant treatment sites. Results: The system performance test suite showed that on our Synergy-S, MLC positioning was accurate under both static and dynamic deliveries. Intentional errors of 1 mm were also easily identified on both static and dynamic picket fence tests. Maximum dose rate was verified with stop watch to be consistently between 475-480 MU/min. Maximum gantry speed and MLC speed were 5.5 degree/s and 2.5 cm/s respectively. After accounting for beam flatness, both synchronization tests, gantry versus dose rate and MLC speed versus dose rate, were successful as the fields were uniform across the strips and there were no obvious cold/hot spots. Conclusion: VMAT commissioning and quality assurance should include machine characterization tests in addition to patient QAs. Elekta iCOM is a valuable tool for the design of customized VMAT field with specific MU, MLC leaf positions, dose rate, and indirect control of MLC and gantry speed at each of its control points.

07 ISOTOPE AND RADIATION SOURCES↗

The phase function of Venus cloud particles from Mariner 10 data

Mariner 10 images of Venus taken at several phase angles were photometrically reduced. The analysis shows that the phase function of the cloud particles is not isotropic, as had been deduced earlier from the brightness distribution on spacecraft images taken at a single phase angle, but has a broad minimum near 60 deg and is forward-scattering. The scattering properties are in quantitative agreement with previous deductions from earth-based polarization measurements by Hansen and his associates.

Hapke, B.↗

High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging

Purpose: Grating-based x-ray phase contrast imaging is considered as one of the most promising techniques for future medical imaging. Many different methods have been developed to retrieve phase signal, among which the phase stepping (PS) method is widely used. However, further practical implementations are hindered, due to its complex scanning mode and high radiation dose. In contrast, the reverse projection (RP) method is a novel fast and low dose extraction approach. In this contribution, the authors present a quantitative analysis of the noise properties of the refraction signals retrieved by the two methods and compare their sensitivities. Methods: Using the error propagation formula, the authors analyze theoretically the signal-to-noise ratios (SNRs) of the refraction images retrieved by the two methods. Then, the sensitivities of the two extraction methods are compared under an identical exposure dose. Numerical experiments are performed to validate the theoretical results and provide some quantitative insight. Results: The SNRs of the two methods are both dependent on the system parameters, but in different ways. Comparison between their sensitivities reveals that for the refraction signal, the RP method possesses a higher sensitivity, especially in the case of high visibility and/or at the edge of the object. Conclusions: Compared with the PS method, the RP method has a superior sensitivity and provides refraction images with a higher SNR. Therefore, one can obtain highly sensitive refraction images in grating-based phase contrast imaging. This is very important for future preclinical and clinical implementations.

60 APPLIED LIFE SCIENCES↗

Reconstructing porous media using generative flow networks

One area of intense scientific interest for the study of sandstones, carbonates, and shale at the pore scale is the use of limited image and petrophysical data to generate multiple realizations of a rock’s pore structure. Such images aid efforts to quantify uncertainty in petrophysical properties, including porosity–permeability transforms. We develop and evaluate a deep learning-based method to synthesize porous media volumes using a so-called generative flow model trained on x-ray microscope images of rock texture and pore structure. These models are optimized on a log-likelihood objective and they synthesize large and realistic three-dimensional images. Further, we demonstrate the rapid generation of sandstone image volumes that display realism as gauged by quantitative comparison of topological features using Minkowski functionals of porosity, specific surface area, and the Euler–Poincaré characteristic (i.e., pore connectivity). We also evaluate the single-phase permeability using Navier–Stokes and lattice Boltzmann methods and show that transport properties of the generated samples match measured trends.

58 GEOSCIENCES↗

edxia: Microstructure characterisation from quantified SEM-EDS hypermaps

The characterisation of cement paste microstructure is an important step towards understanding durability mechanisms in cementitious materials. Scanning electron microscopy (SEM) coupled with energy dispersive spectroscopy (EDS) is a widely used technique to analyse the microstructure at the micron-scale. However, it is challenging, notably because the characteristic size of many phases is found on a scale smaller than the EDS interaction volume. This work presents a new image analysis framework to identify phases and quantify the microstructure of cementitious materials from SEM-EDS hypermaps. By leveraging domain knowledge, representative points are attributed to phases and mixtures of phases based on ratio plots. Then, quantitative analysis of the microstructure can be carried out (chemical composition, particle size distributions, volume fractions, …). We demonstrate the abilities of the framework, and we present possible applications and extensions of the method. The framework is available as both a graphical interface and a Python code.

36 MATERIALS SCIENCE↗

Image-derived and arterial blood sampled input functions for quantitative PET imaging of the angiotensin II subtype 1 receptor in the kidney

Purpose: The radioligand {sup 11}C-KR31173 has been introduced for positron emission tomography (PET) imaging of the angiotensin II subtype 1 receptor in the kidney in vivo. To study the biokinetics of {sup 11}C-KR31173 with a compartmental model, the input function is needed. Collection and analysis of arterial blood samples are the established approach to obtain the input function but they are not feasible in patients with renal diseases. The goal of this study was to develop a quantitative technique that can provide an accurate image-derived input function (ID-IF) to replace the conventional invasive arterial sampling and test the method in pigs with the goal of translation into human studies. Methods: The experimental animals were injected with [{sup 11}C]KR31173 and scanned up to 90 min with dynamic PET. Arterial blood samples were collected for the artery derived input function (AD-IF) and used as a gold standard for ID-IF. Before PET, magnetic resonance angiography of the kidneys was obtained to provide the anatomical information required for derivation of the recovery coefficients in the abdominal aorta, a requirement for partial volume correction of the ID-IF. Different image reconstruction methods, filtered back projection (FBP) and ordered subset expectation maximization (OS-EM), were investigated for the best trade-off between bias and variance of the ID-IF. The effects of kidney uptakes on the quantitative accuracy of ID-IF were also studied. Biological variables such as red blood cell binding and radioligand metabolism were also taken into consideration. A single blood sample was used for calibration in the later phase of the input function. Results: In the first 2 min after injection, the OS-EM based ID-IF was found to be biased, and the bias was found to be induced by the kidney uptake. No such bias was found with the FBP based image reconstruction method. However, the OS-EM based image reconstruction was found to reduce variance in the subsequent phase of the ID-IF. The combined use of FBP and OS-EM resulted in reduced bias and noise. After performing all the necessary corrections, the areas under the curves (AUCs) of the AD-IF were close to that of the AD-IF (average AUC ratio =1 ± 0.08) during the early phase. When applied in a two-tissue-compartmental kinetic model, the average difference between the estimated model parameters from ID-IF and AD-IF was 10% which was within the error of the estimation method. Conclusions: The bias of radioligand concentration in the aorta from the OS-EM image reconstruction is significantly affected by radioligand uptake in the adjacent kidney and cannot be neglected for quantitative evaluation. With careful calibrations and corrections, the ID-IF derived from quantitative dynamic PET images can be used as the input function of the compartmental model to quantify the renal kinetics of {sup 11}C-KR31173 in experimental animals and the authors intend to evaluate this method in future human studies.

60 APPLIED LIFE SCIENCES↗

Quantification of organ motion based on an adaptive image-based scale invariant feature method

Purpose: The availability of corresponding landmarks in IGRT image series allows quantifying the inter and intrafractional motion of internal organs. In this study, an approach for the automatic localization of anatomical landmarks is presented, with the aim of describing the nonrigid motion of anatomo-pathological structures in radiotherapy treatments according to local image contrast.Methods: An adaptive scale invariant feature transform (SIFT) was developed from the integration of a standard 3D SIFT approach with a local image-based contrast definition. The robustness and invariance of the proposed method to shape-preserving and deformable transforms were analyzed in a CT phantom study. The application of contrast transforms to the phantom images was also tested, in order to verify the variation of the local adaptive measure in relation to the modification of image contrast. The method was also applied to a lung 4D CT dataset, relying on manual feature identification by an expert user as ground truth. The 3D residual distance between matches obtained in adaptive-SIFT was then computed to verify the internal motion quantification with respect to the expert user. Extracted corresponding features in the lungs were used as regularization landmarks in a multistage deformable image registration (DIR) mapping the inhale vs exhale phase. The residual distances between the warped manual landmarks and their reference position in the inhale phase were evaluated, in order to provide a quantitative indication of the registration performed with the three different point sets.Results: The phantom study confirmed the method invariance and robustness properties to shape-preserving and deformable transforms, showing residual matching errors below the voxel dimension. The adapted SIFT algorithm on the 4D CT dataset provided automated and accurate motion detection of peak to peak breathing motion. The proposed method resulted in reduced residual errors with respect to standard SIFT, providing a motion description comparable to expert manual identification, as confirmed by DIR.Conclusions: The application of the method to a 4D lung CT patient dataset demonstrated adaptive-SIFT potential as an automatic tool to detect landmarks for DIR regularization and internal motion quantification. Future works should include the optimization of the computational cost and the application of the method to other anatomical sites and image modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗