Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiation imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Silicon ion radiation as a viable surrogate for emulating neutron radiation damage in silicates

Abstract Nuclear power plants are aging around the world, and a precise assessment of irradiation damage in their components is needed. One key component, concrete, and specifically the silicates in its aggregates, can undergo significant expansion upon neutron radiation, which can lead to cracking and, ultimately, structural failure. However, assessing and predicting the extent of damage via neutron radiation is challenging due to reasons such as residual radioactivity and, most importantly, the high time involved. Here, we evaluate whether ion radiation can be a viable surrogate. Specifically, by employing Si 2+ ion radiations and a comprehensive multi-modal imaging protocol, we report mineral-specific responses for key silicates such as quartz, albite, anorthite, and microcline. We find that 10 MeV Si 2+ ions result in mineral expansions that are remarkably comparable to neutron radiation equivalent expansions (R 2 = 0.86, RMSE = 1.29%), opening up pathways towards rapid assessment of silicates subject to irradiation.

36 MATERIALS SCIENCE↗

High-throughput terahertz imaging: progress and challenges

Abstract Many exciting terahertz imaging applications, such as non-destructive evaluation, biomedical diagnosis, and security screening, have been historically limited in practical usage due to the raster-scanning requirement of imaging systems, which impose very low imaging speeds. However, recent advancements in terahertz imaging systems have greatly increased the imaging throughput and brought the promising potential of terahertz radiation from research laboratories closer to real-world applications. Here, we review the development of terahertz imaging technologies from both hardware and computational imaging perspectives. We introduce and compare different types of hardware enabling frequency-domain and time-domain imaging using various thermal, photon, and field image sensor arrays. We discuss how different imaging hardware and computational imaging algorithms provide opportunities for capturing time-of-flight, spectroscopic, phase, and intensity image data at high throughputs. Furthermore, the new prospects and challenges for the development of future high-throughput terahertz imaging systems are briefly introduced.

36 MATERIALS SCIENCE↗

Noise from undetected sources in Dark Energy Survey images

ABSTRACT For ground-based optical imaging with current CCD technology, the Poisson fluctuations in source and sky background photon arrivals dominate the noise budget and are readily estimated. Another component of noise, however, is the signal from the undetected population of stars and galaxies. Using injection of artifical galaxies into images, we demonstrate that the measured variance of galaxy moments (used for weak gravitational lensing measurements) in Dark Energy Survey (DES) images is significantly in excess of the Poisson predictions, by up to 30 per cent, and that the background sky levels are overestimated by current software. By cross-correlating distinct images of ‘empty’ sky regions, we establish that there is a significant image noise contribution from undetected static sources (US), which, on average, are mildly resolved at DES resolution. Treating these US as a stationary noise source, we compute a correction to the moment covariance matrix expected from Poisson noise. The corrected covariance matrix matches the moment variances measured on the injected DES images to within 5 per cent. Thus, we have an empirical method to statistically account for US in weak lensing measurements, rather than requiring extremely deep sky simulations. We also find that local sky determinations can remove most of the bias in flux measurements, at a small penalty in additional, but quantifiable, noise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photonuclear cross sections for the 197 Au ⁢(𝛾, 𝑝⁢𝑛)⁢ 195⁢𝑚 Pt reaction near threshold

Platinum radioisotopes are of growing interest for targeted cancer therapy and diagnostic imaging because their decay delivers highly localized radiation doses in tissue, herewith enabling precise DNA damage through Auger-electron emission. Developing production technologies that provide platinum isotopes with high specific activity is essential in radioisotope therapy. Photonuclear reactions on stable nuclei offer a viable accelerator-based route for isotope production when supported by reliable cross-section data. We report photonuclear cross-section measurements for the 197 Au(γ, pn) 195m Pt reaction at incident γ-ray energies of 27, 29, and 31 MeV using the activation method. The measurements were performed by irradiating a stack of concentric-ring gold targets with a quasi-monoenergetic γ-ray beam provided by the High Intensity Gamma-ray Source (HI γS). The induced 195m Pt activity was quantified using off-line γ-ray spectroscopy. These data provide the first experimental constraints on the 197 Au(γ, pn) 195m Pt cross section in the near-threshold region. Furthermore, the comparison of the measured excitation function to PHITS and TALYS calculations indicates that the reaction becomes measurable only near 30 MeV and that substantially higher bremsstrahlung end-point energies are required for practically meaningful production.

190 ≤ A ≤ 219↗

Analysis of streaked images of x-ray self-emission in laser-driven spherical implosions

Imaging of x-ray self-emission provides a powerful in situ measurement of the spatial and temporal evolution of high-energy-density plasmas. However, interpretation of these measurements requires detailed understanding of the data-generating process. This work presents a case study in the interpretation of x-ray self-emission data for the specific application of streaked one-dimensional slit imaging of spherical laser-driven implosions. A comprehensive generative model of the streaked slit-imaging diagnostic is developed including detailed treatments of the radiation transfer, photometrics, and photostatistics associated with the measurement. The model is used to generate realistic synthetic streaked images and to analyze experimental streaked images to extract important physical quantities of interest. An example analysis of streaked images from implosion experiments on the OMEGA laser is presented, where the model developed in this work is used to constrain the trajectory and peak velocity of the implosion using Bayesian inference.

Bayesian inference↗

Infrared MBE-Grown HgCdTe Focal Plane Arrays and Cameras After High Energy Neutron Irradiation

HgCdTe is one of the most important materials for the fabrication of infrared detectors and focal plane arrays (FPAs) deployed in environments where high-energy particles, such as protons and neutrons, are present. We designed and fabricated HgCdTe-based FPAs that can be used in high neutron radiation environments and we measured their characteristics. The influence of the radiation on the infrared FPAs and cameras is investigated. HgCdTe material and devices are capable of maintaining high performances in a high energy neutron irradiation environment. For MWIR FPA directly facing a $2.59 × 10^8$ n/cm$^2$ s neutron flux beam (with the highest energy 66 MeV) for 1 h, the noise equivalent differential temperature (NEDT) increased ~8 times after irradiation. However, NEDT decreased to 33 mK (compared to the original value of 21 mK) after one warming-up (to room temperature) and cooling-down cycle. The NEDT for the MWIR FPAs mounted parallel to the beam did not degrade (16 mK and 28 mK before irradiation, changed to 18 mK and 26 mK after irradiation, respectively).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0νββ), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0νββ of 136 Xe with projected half-life sensitivity of 1.35 x 10 28 yr. To reach this sensitivity, the design goal for nEXO is ≤1% energy resolution at the decay Q-value (2458.07 ± 0.31 keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163 K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay Q-value for the nEXO design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Feasibility of Directly Imaging Nearby Cold Jovian Planets with MIRI/JWST

The upcoming launch of the James Webb Space Telescope (JWST) will dramatically increase our understanding of exoplanets, particularly through direct imaging. Microlensing and radial velocity surveys indicate that some M dwarfs host long-period giant planets. Some of these planets will likely be just a few parsecs away and a few astronomical units from their host stars, a parameter space that cannot be probed by existing high-contrast imagers. We studied whether the coronagraphs on the Mid-infrared Instrument on JWST can detect Jovian-type planets around nearby M dwarfs. For a sample of 27 very nearby M dwarfs, we simulated a sample of Saturn–Jupiter-mass planets with three atmospheric configurations and three orbital separations, observed in three different filters. We found that the f1550c 15.5 μm filter is best suited for detecting Jupiter-like planets. Jupiter-like planets with patchy cloud cover, 2 au from their star, are detectable at 15.5 μm around 14 stars in our sample, while Jupiters with clearer atmospheres are detectable around all stars in the sample. Saturns were most detectable at 10.65 and 11.4 μm (f1065c and f1140c filters), but only with cloud-free atmospheres and within 3 pc (six stars). Surveying all 27 stars would take <170 hr of JWST integration time, or just a few hours for a shorter survey of the most favorable targets. There is one potentially detectable known planet in our sample: GJ 832 b. Observations aimed at detecting this planet should occur in 2024–2026, when the planet is maximally separated from the star.

79 ASTRONOMY AND ASTROPHYSICS↗

Poster for 12th World Conference for Neutron Radiography (WCNR-12)

Complimentary Relationships Between Neutron Computed Radiography and Digital X-ray Radiography of Radioactive Specimens The Transient Reactor Test (TREAT) Facility is a 19,000 MW reactor located at the Idaho National Laboratory which is used for transient testing of materials and experiments. A neutron radiography facility is installed which allows for low resolution neutron imaging with a capability of items up to 20 cm wide and 400 cm long. Along with the neutron radiography facility, a 370 kV digital X-ray system is located onsite for when X-ray imaging is more practical or when rapid imaging is requested. The X-ray facility can accommodate specimens up to 61 cm wide and 1000 cm long. This poster discusses the complimentary relationship between transfer-method Neutron Computed Radiography (nCR) and Digital X-ray Radiography (DR) imaging of radioactive specimens along with practical applications for nuclear fuels and materials testing programs. Both nCR and DR images were acquired of inert gas and water filled apparatus containing differing materials at varying radiation levels. Highly radioactive items have no effect on nCR image quality whereas radioactivity has varying degrees of effect in DR. Radioactive items as high as 20 mSv/h have been successfully imaged using X-ray DR methods.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Synchrotron X-ray based particle image velocimetry to measure multiphase streamflow and densitometry

Synchrotron-based radiation techniques are increasingly used in the field of flow condition measurements. As a complicated multiphase flow, cavitation has been investigated in a wide variety of industrial fields, to prevent damages on spillways at large dams or intensify the bacteria eradication rate during water treatments. To control the detrimental effects of cavitating flows, the dynamics of and mechanisms affecting cavitation development shall be visualized and identified in real-time. Due to the large reflection and scattering effects of multiphase flow, standard visible-light imaging technologies cannot penetrate vapor bubbles and provide extremely limited information. In this study, the synchrotron source emitted high-flux X-ray pulses are used to capture flow motion and visualize internal structures with sufficiently high spatial and temporal resolutions. The image processing procedures on raw x-ray images are developed using 2D Fourier transform (FT) and wavelet transform (WT) to implement the contrast enhancement and de-noising. Through the edge detection algorithm, tracking either seeded particles or phase interfaces inside the opaque multiphase flow can be achieved to perform the particle image velocimetry. Further, with decomposing particle-only and particle-eliminated subplots from the X-ray phase-contrast image, the time-resolved velocity and void fraction fields are obtained simultaneously, paving a way for further flow condition analysis such as densitometry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cryo-electron tomography related radiation-damage parameters for individual-molecule 3D structure determination

To understand the dynamic structure–function relationship of soft- and biomolecules, the determination of the three-dimensional (3D) structure of each individual molecule (nonaveraged structure) in its native state is sought-after. Cryo-electron tomography (cryo-ET) is a unique tool for imaging an individual object from a series of tilted views. However, due to radiation damage from the incident electron beam, the tolerable electron dose limits image contrast and the signal-to-noise ratio (SNR) of the data, preventing the 3D structure determination of individual molecules, especially at high-resolution. Although recently developed technologies and techniques, such as the direct electron detector, phase plate, and computational algorithms, can partially improve image contrast/SNR at the same electron dose, the high-resolution structure, such as tertiary structure of individual molecules, has not yet been resolved. Here, we review the cryo-electron microscopy (cryo-EM) and cryo-ET experimental parameters to discuss how these parameters affect the extent of radiation damage. This discussion can guide us in optimizing the experimental strategy to increase the imaging dose or improve image SNR without increasing the radiation damage. With a higher dose, a higher image contrast/SNR can be achieved, which is crucial for individual-molecule 3D structure. With 3D structures determined from an ensemble of individual molecules in different conformations, the molecular mechanism through their biochemical reactions, such as self-folding or synthesis, can be elucidated in a straightforward manner.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adaptive Radiation Therapy (ART) Strategies and Technical Considerations: A State of the ART Review From NRG Oncology

The integration of adaptive radiation therapy (ART), or modifying the treatment plan during the treatment course, is becoming more widely available in clinical practice. ART offers strong potential for minimizing treatment-related toxicity while escalating or de-escalating target doses based on the dose to organs at risk. Yet, ART workflows add complexity into the radiation therapy planning and delivery process that may introduce additional uncertainties. This work sought to review presently available ART workflows and technological considerations such as image quality, deformable image registration, and dose accumulation. Quality assurance considerations for ART components and minimum recommendations are described. Personnel and workflow efficiency recommendations are provided, as is a summary of currently available clinical evidence supporting the implementation of ART. Finally, to guide future clinical trial protocols, an example ART physician directive and a physics template following standard NRG Oncology protocol is provided.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterizing Dislocation Defects in Dark Field X-ray Microscopy Images of Bulk Aluminum

Material defects play a large role in material response under shock loading, yet the process of how these defects initiate, propagate, and annihilate is not well understood. Using a newly developed diagnostic, dark field X-ray microscopy (DFXM), we can now visualize the behavior of dislocation defects in materials at the mesoscale under varying conditions. Using data from the European Synchrotron Radiation Facility, we apply a variety of image processing techniques to capture relevant features to locate and characterize size and orientation of dislocation defects in bulk aluminum DFXM images. Beyond simple visualization, this analysis drives statistical characterization of the defects and their dynamic response to further improve the relevant physics models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing cloud motion estimation on the edge with phase correlation and optical flow

Abstract. Phase correlation (PC) is a well-known method for estimating cloud motion vectors (CMVs) from infrared and visible spectrum images. Commonly, phase shift is computed in the small blocks of the images using the fast Fourier transform. In this study, we investigate the performance and the stability of the blockwise PC method by changing the block size, the frame interval, and combinations of red, green, and blue (RGB) channels from the total sky imager (TSI) at the United States Atmospheric Radiation Measurement user facility's Southern Great Plains site. We find that shorter frame intervals, followed by larger block sizes, are responsible for stable estimates of the CMV, as suggested by the higher autocorrelations. The choice of RGB channels has a limited effect on the quality of CMVs, and the red and the grayscale images are marginally more reliable than the other combinations during rapidly evolving low-level clouds. The stability of CMVs was tested at different image resolutions with an implementation of the optimized algorithm on the Sage cyberinfrastructure test bed. We find that doubling the frame rate outperforms quadrupling the image resolution in achieving CMV stability. The correlations of CMVs with the wind data are significant in the range of 0.38–0.59 with a 95 % confidence interval, despite the uncertainties and limitations of both datasets. A comparison of the PC method with constructed data and the optical flow method suggests that the post-processing of the vector field has a significant effect on the quality of the CMV. The raindrop-contaminated images can be identified by the rotation of the TSI mirror in the motion field. The results of this study are critical to optimizing algorithms for edge-computing sensor systems.

54 ENVIRONMENTAL SCIENCES↗

Multimodal, Multidimensional, and Multiscale X-ray Imaging at the National Synchrotron Light Source II

Over the last couple of decades, the synchrotron radiation research community has witnessed tremendous advancement in the field of x-ray imaging and microscopy. Continuing enhancement of the light sources’ brightness, advances in x-ray focusing optics, incorporation of precision instruments, and development of innovative imaging techniques are some of the leading contributors for the rapid progress. New imaging and microscopy beamlines, such as the ones at the National Synchrotron Light Source II (NSLS-II), a Department of Energy (DOE) Office of Science user facility located at DOE’s Brookhaven National Laboratory, are capable of performing more sophisticated and complicated measurements than ever before, either on their own or used together as a suite of tools. These sophisticated and complex measurements exhibit attributes for multimodal, multidimensional, and multiscale imaging. Recent popularity of these methods is strongly driven by the current trends in materials characterizations, where researchers desire to map out hierarchical materials structure over a large range of length scales, to understand structure-property correlation, to quantify materials structures in 3D, and/or to perform operando or in situ experiments. It is important to emphasize that “materials” under investigation are not only synthesized materials but also the natural materials. In this article, we describe multimodal, multidimensional and multiscale x-ray imaging capabilities of the NSLS-II beamlines and how these methods are used to tackle complex scientific problems.

47 OTHER INSTRUMENTATION↗

Fast Neutron Scintillator Screens for Neutron Imaging Using a Layered Polymer-Phosphor Architecture

Fast neutrons enable a nondestructive examination of dense, large, and highly attenuating samples due to their lower interaction probability compared to thermal neutrons. However, this also creates a challenge in fast neutron imaging, as the thicker sensors necessary to detect fast neutrons degrade an image’s spatial resolution due to scattering within the sensor and the indeterminate depth of interaction in the sensor. This work explores the advantages of a fast neutron imaging screen with a layered polymer-phosphor screen approach as opposed to a mixed polymer-phosphor screen typically used in fast neutron imaging. Proton recoil is the primary conversion mechanism for fast neutron imaging. Simulations showed that the recoil proton range of typical fast neutrons is approximately 200 µm, however, tests at Idaho National Laboratory revealed that the light output of these screens increased at much greater polymer thicknesses. The NECTAR fast neutron beamline at FRM II was used to test the imaging performance of layered fast neutron imaging screens. Distinguishing between the fast-neutron and γ-ray signals is a major challenge in fast neutron imaging because all fast neutron sources also produce γ-rays. A relative comparison between a control plate and the fast neutron screen was made to distinguish between a γ-ray and fast neutron signals. MCNP modeling quantified the γ-ray and fast neutron contributions to the images measured at NECTAR, which were approximately a 75% γ-ray image.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗