Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiometer uncertainty”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Inferred Variable FeO Content in Medium-sized Lunar Pyroclastic Deposits from LRO Diviner Data

Lunar pyroclastic deposits (LPDs) are low albedo features that mantle underlying terrain (Gaddis et al. 1985). They are high priority targets for science and exploration as they are believed to originate from and therefore reflect the composition of the deep lunar interior (NRC, 2011). They are also the best potential resource of oxygen out of any Apollo samples (Allen et al. 1996). Historically, LPDs have been divided into regional versus local categories (Gaddis et al. 2003). The large (>1000 km2 area) regional deposits are deeply sourced (>400 km deep) and result from fire fountaining. Small (<1000 km2) local deposits are thought to result from Vulcanian eruptions in which magma is slowly emplaced beneath the surface until enough volatiles exsolve and the high pressure causes an explosion. Bennett et al. (2013) identified a local deposit (674 km2 area) that may have resulted from both Vulcanian activity and fire fountaining. This deposit potentially represents a new intermediate class of LPDs that straddles the interface between the two formation mechanisms. The deposit also exhibits the highest inferred FeO wt.% of any known lunar glass. In this work we investigate the inferred FeO abundances of other medium-sized deposits to characterize this potential new class of deposits and understand the magnitude of variations in inferred FeO among pyroclastic deposits. We use the method of Greenhagen et al. (2010) to calculate the wavelength of the Christiansen Feature (CF) from Lunar Reconnaissance Orbiter Diviner Lunar Radiometer instrument thermal-infrared observations for four medium-sized deposits. From the CF values, we estimate each deposit's FeO abundance using the method of Allen et al. (2012). The four LPDs that we examined (Oppenheimer South, Beer, Cleomedes, and J. Herschel) all have average CF values from 8.22-8.28 microns, corresponding to FeO abundances of approx. 10-15 wt.%. All of these values are within the range and uncertainties of FeO abundances measured in Apollo samples. As previously identified, the Oppenheimer South deposit exhibits an area of enhanced CF values (8.49 microns) that, if the methods of Allen et al. (2012) can be extrapolated, correspond to a highest observed approx. 30 wt.% FeO. Moon Mineralogy Mapper near-infrared spectra indicate that this area is glass-rich as opposed to olivine-rich. While we are still investigating the nature of the high CF wavelength in Oppenheimer South, spatially-resolved observations there and (to a smaller degree) in our other study sites, shows that FeO wt.% can vary within LPDs. Thus, obtaining only the average FeO abundance over a large area may not be adequate to understand global variation. The magnitude of Oppenheimer South's CF variability, if due to actual surface variations rather than calibration artifacts or spectral mixing, could indicate that it is a unique deposit and not part of a new mid-sized class of deposits. The higher value could be a result of its location within the South Pole Aitken Basin and exsolution of more deeply sourced magma due to the thin crust there.

Bennett, K. A.↗

Wiener filtering of the COBE Differential Microwave Radiometer data

We derive an optimal linear filter to suppress the noise from the cosmic background explorer satellite (COBE) Differential Microwave Radiometer (DMR) sky maps for a given power spectrum. We then apply the filter to the first-year DMR data, after removing pixels within 20 deg of the Galactic plane from the data. We are able to identify particular hot and cold spots in the filtered maps at a level 2 to 3 times the noise level. We use the formalism of constrained realizations of Gaussian random fields to assess the uncertainty in the filtered sky maps. In addition to improving the signal-to-noise ratio of the map as a whole, these techniques allow us to recover some information about the cosmic microwave background anisotropy in the missing Galactic plane region. From these maps we are able to determine which hot and cold spots in the data are statistically significant, and which may have been produced by noise. In addition, the filtered maps can be used for comparison with other experiments on similar angular scales.

Bunn, Emory F.↗

Mars2020 Entry, Descent, and Landing Instrumentation 2 (MEDLI2) Do No Harm Test Series

A total of seventeen instrumented thermal sensor plugs, eight pressure transducers, two heat flux sensors, and one radiometer are planned to be utilized on the Mars 2020 missions thermal protection system (TPS) as part of the Mars Entry, Descent, and Landing Instrumentation II (MEDLI2) project. Of the MEDLI2 instrumentation, eleven instrumented thermal plugs and seven pressure transducers will be installed on the heatshield of the Mars 2020 vehicle while the rest will be installed on the backshell. The goal of the MEDLI2 instrumentation is to directly inform the large performance uncertainties that contribute to the design and validation of a Mars entry system. A better understanding of the entry environment and TPS performance could lead to reduced design margins enabling a greater payload mass-fraction and smaller landing ellipses. To prove that the MEDLI2 system will not degrade the performance of the Mars 2020 TPS, an Aerothermal Do No Harm (DNH) test series was designed and conducted. Like Mars 2020s predecessor, Mars Science Laboratory (MSL), the heatshield material will be Phenolic Impregnated Carbon Ablator (PICA); the Mars 2020 entry conditions are enveloped by the MSL design environments, therefore the development and qualification testing performed during MEDLI is sufficient to show that the similar MEDLI2 heatshield instrumentation will not degrade PICA performance. However, given that MEDLI did not include any backshell instrumentation, the MEDLI2 team was required to design and execute a DNH test series utilizing the backshell TPS material (SLA-561V) with the intended flight sensor suite. To meet the requirements handed down from Mars 2020, the MEDLI2 DNH test series emphasized the interaction between the MEDLI2 sensors and sensing locations with the surrounding backshell TPS and substrucutre. These interactions were characterized by performing environmental testing of four 12 by 12 test panels, which mimicked the construction of the backshell TPS and the integration of the MEDLI2 sensors as seen in Figure 1. The testing included thermal vacuumcycling, random vibration, shock, and arc jet testing. The test panels were fabricated by Lockheed Martin, establishing techniques that will be utilized during the Mars 2020 vehicle installation. Each test panel included one thermal sensor plug (two embedded thermocouples), one heat flux sensor, and multiple pressure port holes for evaluation.This presentation will discuss the planning and execution of the MEDLI2 DNH test series. Selected highlights and results of each environmental test will be presented, and lessons learned will be addressed that will feed forward into the planning for the MEDLI2 flight system certification testing.

backshell↗

The absolute radiometric calibration of the advanced very high resolution radiometer

The early results of an absolute radiometric calibration of the NOAA-9 AVHRR sensor indicate significant degradations in the response of bands 1 and 2 compared to prelaunch values. The results are currently in the process of being verified and it may be that refinements of the methodology will be in order as additional data sets are analyzed. The LANDSAT TM calibration used in this approach is known to be very precise and the Herman radiative transfer code, supplemented by the 5-S code for gaseous transmission, is reliable as well. The extent to which other steps in the analysis procedure give rise to uncertainties in the results is currently under investigation. Particular attention is being given to the geometric matching of the AVHRR and TM imagery, as well as to the spectral redistribution procedure. By taking advantage of a reasonably precise calibration of TM imagery acquired on the same day as the AVHRR data at White Sands, a promising approach to the in-orbit calibration of AVHRR sensors is being developed. Current efforts involve primarily the examination of additional test cases and the investigation of possible simplifications in the procedure through judicious use of atmospheric models.

Slater, P. N.↗

Northern Hemisphere Surface Freeze-Thaw Product from Aquarius L-Band Radiometers

In the Northern Hemisphere, seasonal changes in surface freeze–thaw (FT) cycles are an important component of surface energy, hydrological and eco-biogeochemical processes that must be accurately monitored. This paper presents the weekly polar-gridded Aquarius passive L-band surface freeze–thaw product (FT-AP) distributed on the Equal-Area Scalable Earth Grid version 2.0, above the parallel 50 N, with a spatial resolution of 36 km36 km. The FT-AP classification algorithm is based on a seasonal threshold approach using the normalized polarization ratio, references for frozen and thawed conditions and optimized thresholds. To evaluate the uncertainties of the product, we compared it with another satellite FT product also derived from passive microwave observations but at higher frequency: the resampled 37 GHz FT Earth Science Data Record (FTESDR). The assessment was carried out during the overlapping period between 2011 and 2014. Results show that 77.1% of their common grid cells have an agreement better than 80 %. Their differences vary with land cover type (tundra, forest and open land) and freezing and thawing periods. The best agreement is obtained during the thawing transition and over forest areas, with differences between product mean freeze or thaw onsets of under 0.4 weeks. Over tundra, FT-AP tends to detect freeze onset 2–5 weeks earlier than FT-ESDR, likely due to FT sensitivity to the different frequencies used. Analysis with mean surface air temperature time series from six in situ meteorological stations shows that the main discrepancies between FT-AP and FT-ESDR are related to false frozen retrievals in summer for some regions with FT-AP. The Aquarius product is distributed by the U.S. National Snow and Ice Data Center (NSIDC) at https://nsidc.org/data/aq3_ft/versions/5 with the DOI https://doi.org/10.5067/OV4R18NL3BQR.

Prince, Michael↗

Instrumentation for measurements of solar irradiance and atmospheric optical properties

The Active Cavity Radiometer (ACR), an accurate absolute pyrheliometer, has been developed for measurements of total solar irradiance. It has been used to discover a -2.2% error in the International Pyrheliometric Scale and to make measurements in balloon flight experiments yielding a solar constant value of 136.6 (+ or - 0.7) mW/sq cm. New ACRs are being developed to monitor the total output of solar optical radiation in balloon, satellite and space shuttle experiments with long-term absolute uncertainty of + or - 0.1% or less. In a separate program, instrumentation for the measurement of the scattering and extinction of solar radiation by the atmosphere is being constructed to provide data for modeling atmospheric aerosol content. The aerosol models will facilitate computation of radiative transfer effects yielding quantitative net fluxes useful in evaluating the climatological impact of aerosols.

Willson, R. C.↗

Achieving Climate Change Absolute Accuracy in Orbit

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission will provide a calibration laboratory in orbit for the purpose of accurately measuring and attributing climate change. CLARREO measurements establish new climate change benchmarks with high absolute radiometric accuracy and high statistical confidence across a wide range of essential climate variables. CLARREO's inherently high absolute accuracy will be verified and traceable on orbit to Système Internationale (SI) units. The benchmarks established by CLARREO will be critical for assessing changes in the Earth system and climate model predictive capabilities for decades into the future as society works to meet the challenge of optimizing strategies for mitigating and adapting to climate change. The CLARREO benchmarks are derived from measurements of the Earth's thermal infrared spectrum (5-50 micron), the spectrum of solar radiation reflected by the Earth and its atmosphere (320-2300 nm), and radio occultation refractivity from which accurate temperature profiles are derived. The mission has the ability to provide new spectral fingerprints of climate change, as well as to provide the first orbiting radiometer with accuracy sufficient to serve as the reference transfer standard for other space sensors, in essence serving as a "NIST [National Institute of Standards and Technology] in orbit." CLARREO will greatly improve the accuracy and relevance of a wide range of space-borne instruments for decadal climate change. Finally, CLARREO has developed new metrics and methods for determining the accuracy requirements of climate observations for a wide range of climate variables and uncertainty sources. These methods should be useful for improving our understanding of observing requirements for most climate change observations.

Wielicki, Bruce A.↗

On the Dome Effect of Flux Radiometers to Radiative Forcing

Since the introduction of thermopile, pyranometers (solar, e.g., 0.3-3.0 micrometers) and pyrgeometers (terrestrial, e.g., 4-50 micrometers) have become instruments commonly used for measuring the broadband hemispherical irradiances at the surface in a long-term, monitoring mode for decades. These commercially available radiometers have been manufactured in several countries such as from the United States, Asia, and Europe, and are generally reliable and economical. These worldwide distributions of surface measurements become even more important in the era of Earth remote sensing in studying climate forcing. However, recent studies from field campaigns have pointed out that erroneous factors (e.g., temperature gradients between the filter dome and detector, emissivity of the thermopile) are responsible for the unacceptable level of uncertainty (e.g., 10-20 W m (exp -2)). Using a newly developed instrument of Quantum Well Infrared Photodetector (QWIP), we have characterized the brightness temperature fields of pyranometers and pyrgeometers under various sky conditions. The QWIP is based on the superlattice (GaAs/AlGaAs) technology and has a noise equivalent temperature (NE delta T) less than 0.1 K. The quality of pyranometer and pyrgeometer measurements can be improved largely by applying proper knowledge of the thermal parameters affecting the operation of the thermopile systems. For example, we show a method to determine the "dome factor" (the longwave emission divided by the longwave transmission of a pyrgeometer dome) from field measurements. The results show, and are verified independently by the QWIP, that our dome factors of 0.59 and 0.90 are much smaller than the value of 4.0 assumed by the WMO (World Meteorological Organization). Data correction procedure and algorithm will be presented and discussed.

Tsay, S.-C.↗

On the Dome Effect of Flux Radiometers to Radiative Forcing

Since the introduction of thermopile, pyranometers (solar, e.g., 0.3-3.0 microns) and pyrgeometers (terrestrial, e.g., 4-50 microns) have become instruments commonly used for measuring the broadband hemispherical irradiances at the surface in a long-term, monitoring mode for decades. These commercially available radiometers have been manufactured in several countries such as from the United States, Asia, and Europe, and are generally reliable and economical. These worldwide distributions of surface measurements become even more important in the era of Earth remote sensing in studying climate forcing. However, recent studies from field campaigns have pointed out that erroneous factors (e.g., temperature gradients between the filter dome and detector, emissivity of the thermopile) are responsible for the unacceptable level of uncertainty (e.g., 10-20 W/square Meter). Using a newly developed instrument of Quantum Well Infrared Photodetector (QWIP), we have characterized the brightness temperature fields of pyranometers and pyrgeometers under various sky conditions. The QWIP is based on the superlattice (GaAs/AlGaAs) technology and has a noise equivalent temperature (NE delta T) less than 0.1 K. The quality of pyranometer and pyrgeometer measurements can be improved largely by applying proper knowledge of the thermal parameters affecting the operation of the thermopile systems. For example, we show a method to determine the "dome factor" (the longwave emission divided by the longwave transmission of a pyrgeometer dome) from field measurements. The results show, and are verified independently by the QWIP, that our dome factors of 0.59 and 0.90 are much smaller than the value of 4.0 assumed by the WMO. Data correction procedure and algorithm will be presented and discussed.

Tsay, S.-C.↗

Characterization of Thermal Parameters for Improving Pyranometer and Pyrgeometer Measurements

Since the introduction of thermopile, pyranometers (solar, e.g., 0.3-3.0 micrometers) and pyrgeometers (terrestrial, e.g., 4-50 micrometers) have become instruments commonly used for measuring the broadband hemispherical irradiances at the surface in a long-term, monitoring mode for decades. These commercially available radiometers have been manufactured in several countries such as from the United States, Asia, and Europe, and are generally reliable and economical. These worldwide distributions of surface measurements become even more important in the era of Earth remote sensing in studying climate change. However, recent studies from field campaigns have pointed out that erroneous factors (e.g., temperature gradients between the filter dome and detector, emissivity of the thermopile) are responsible for the unacceptable level of uncertainty (e.g., 20 W m(exp -2)). Using a newly developed instrument of Quantum Well Infrared Photodetector (QWTP), we have characterized the brightness temperature fields of pyranometers and pyrgeometers under various sky conditions. The QWIP is based on the superlattice (GaAs/AlGaAs) technology and has a noise equivalent temperature (NEAT) less than 0.1 K. The quality of pyranometer and pyrgeometer measure- ments can be improved largely by applying proper knowledge of the thermal parameters affecting the operation of the thermopile systems. Data correction procedure and algorithm will be presented and discussed.

Tsay, Si-Chee↗

Thermal Characteristics of Pyranometers and Pyrgeometers in Atmosphere-Surface Energetic Measurements

Since the introduction of thermopile, pyranometers (solar, e.g., 0.3 - 3.0 microns) and pyrgeometers (terrestrial, e.g., 4 - 50 microns) have become instruments commonly used for measuring the broadband hemispherical irradiances at the surface in a long-term, monitoring mode for decades. These commercially available radiometers have been manufactured in several countries such as from the United States, Asia, and Europe, and are generally reliable and economical. These worldwide distributions of surface measurements become even more important in the era of Earth remote sensing in studying climate change. However, recent studies from field campaigns have pointed out that erroneous factors (e.g., temperature gradients between the filter dome and detector, emissivity of the thermopile) are responsible for the unacceptable level of uncertainty (e.g., 20 W/sq m). It is best to utilize an energy balance equation to describe the thermal dome effect of pyranometers and pyrgeometers. Therefore, quality of pyranometer and pyrgeometer measurements can be improved largely by applying proper knowledge of the thermal parameters affecting the operation of the thermopile systems. Data correction procedure and algorithm will be presented and discussed.

Tsay, Si-Chee↗

A Robust Retrieval of Water Vapor Column In Dry Arctic Conditions Using the Rotating Shadowband Spectroradiometer

A method to retrieve water vapor column using the 940-nm water vapor absorption band in dry Arctic conditions is presented. The retrievals with this method are stable with respect to uncertainties in instrument radiometric calibration, air pressure, solar source function, and aerosols. The water vapor column was retrieved with this method using spectra obtained with the rotating shadowband spectroradiometer (RSS) that was deployed during an intensive observation period near Barrow, Alaska, in March 1999. A line-by-line radiative transfer model was used to compute water vapor transmittance. The retrievals with this method are compared with retrievals obtained from three independent measurements with microwave radiometers. All four measurements show the same pattern of temporal variations. The RSS results agree most closely with retrievals obtained with the millimeter-wave imaging radiometer (MIR) at its 183 GHz +/- 7 double-side band channel. Their correlation over a period of 7 days when water vapor column varied between 0.75 mm and 3.6 mm (according to RSS) is 0.968 with MIR readings 0.12 mm higher on average.

Kiedron, P.↗

TOPEX Microwave Radiometer Thermal Control: Post-System-Test Modifications and On-Orbit Performance

The Topex Microwave Radiometer has had an excellent thermal performance since launch. The instrument, however, went through a hardware modification right before launch to correct for athermal design inadequacy that was uncovered during the spacecraft thermal vacuum test. This paper reports on how the initially obscure problem was tracked down, and how the thermal models were revised, validated, and utilized to investigate the solution options and guide the hardware modification decisions. Details related to test data interpretation, analytical uncertainties, and model-prediction vs. test-data correlation, are documented. Instrument/spacecraft interface issues, where the problem originated and where in general pitfalls abound, are dealt with specifically. Finally, on-orbit thermal performance data are presented, which exhibit good agreement with flight predictions, and lessons learned are discussed.

Lin, Edward I.↗

Topex Microwave Radiometer thermal control - Post-system-test modifications and on-orbit performance

The Topex Microwave Radiometer has had an excellent thermal performance since launch. The instrument, however, went through a hardware modification right before launch to correct for a thermal design inadequacy that was uncovered during the spacecraft thermal vacuum test. This paper reports on how the initially obscure problem was tracked down, and how the thermal models were revised, validated, and utilized to investigate the solution options and guide the hardware modification decisions. Details related to test data interpretation, analytical uncertainties, and model-prediction vs. test-data correlation, are documented. Instrument/spacecraft interface issues, where the problem originated and where in general pitfalls abound, are dealt with specifically. Finally, on-orbit thermal performance data are presented, which exhibit good agreement with flight predictions, and lessons learned are discussed.

Lin, Edward I.↗

Subsurface Emission Effects in AMSR-E Measurements: Implications for Land Surface Microwave Emissivity Retrieval

An analysis of land surface microwave emission time series shows that the characteristic diurnal signature associated with subsurface emission in sandy deserts carry over to arid and semi-arid region worldwide. Prior work found that diurnal variation of Special Sensor Microwave/Imager (SSM/I) brightness temperatures in deserts was small relative to International Satellite Cloud Climatology Project land surface temperature (LST) variation and that the difference varied with surface type and was largest in sand sea regions. Here we find more widespread subsurface emission effects in Advanced Microwave Scanning Radiometer-EOS (AMSR-E) measurements. The AMSR-E orbit has equator crossing times near 01:30 and 13 :30 local time, resulting in sampling when near-surface temperature gradients are likely to be large and amplifying the influence of emission depth on effective emitting temperature relative to other factors. AMSR-E measurements are also temporally coincident with Moderate Resolution Imaging Spectroradiometer (MODIS) LST measurements, eliminating time lag as a source of LST uncertainty and reducing LST errors due to undetected clouds. This paper presents monthly global emissivity and emission depth index retrievals for 2003 at 11, 19, 37, and 89 GHz from AMSR-E, MODIS, and SSM/I time series data. Retrieval model fit error, stability, self-consistency, and land surface modeling results provide evidence for the validity of the subsurface emission hypothesis and the retrieval approach. An analysis of emission depth index, emissivity, precipitation, and vegetation index seasonal trends in northern and southern Africa suggests that changes in the emission depth index may be tied to changes in land surface moisture and vegetation conditions

Galantowicz, John F.↗

Directional Reflectance Studies in Support of the Radiometric Calibration Test Site (RadCaTS) at Railroad Valley

The Radiometric Calibration Test Site (RadCaTS) is a suite of commercial and custom instruments used to make measurements of the surface reflectance and atmosphere throughout the day at Railroad Valley, Nevada. It was developed in response to the need for daily radiometric calibration data for the vast array of Earth-observing sensors on orbit, which is continuously increasing as more nations and private companies launch individual environmental satellites as well as large constellations. The current suite of instruments at RadCaTS includes five ground-viewing radiometers (GVRs), four of which view the surface in a nadir-viewing configuration. Many sensors such as those on Landsat-7 and Landsat-8 view Railroad Valley within 3° of nadir, while others such as those on Sentinel-2A and -2B, RapidEye, Aqua, Suomi NPP, and Terra can view Railroad Valley at off-nadir angles. Past efforts have shown that the surface bidirectional reflectance distribution function (BRDF) has minimal impact on vicarious calibration uncertainties for views <10°, but the desire to use larger view angles has prompted the effort to develop a BRDF correction for data from RadCaTS. The current work investigates the application of Railroad Valley BRDF data derived from a BRF camera developed at the University of Arizona in the 1990s (but is no longer in use) to the current RadCaTS surface reflectance measurements. Also investigated are early results from directional reflectance studies using a mobile spectro-goniometer system during a round-robin field campaign in 2018. This work describes the preliminary results, the effects on current measurements, and the approach for future measurements.

RadCalNet↗

Validation of SAGE II aerosol measurements by comparison with correlative sensors

The SAGE II limb-scanning radiometer carried on the Earth Radiation Budget Satellite functions at wavelengths of 0.385, 0.45, 0.525, and 1.02 microns to identify vertical profiles of aerosol density by atmospheric extinction measurements from cloud tops upward. The data are being validated by correlating the satellite data with data gathered with, e.g., lidar, sunphotometer, and dustsonde instruments. Work thus far has shown that the 1 micron measurements from the ground and satellite are highly correlated and are therefore accurate to within measurement uncertainty.

Swissler, T. J.↗

Validation of Radiometric Standards for the Laboratory Calibration of Reflected-Solar Earth Observing Satellite Instruments

Historically, the traceability of the laboratory calibration of Earth-observing satellite instruments to a primary radiometric reference scale (SI units) is the responsibility of each instrument builder. For the NASA Earth Observing System (EOS), a program has been developed using laboratory transfer radiometers, each with its own traceability to the primary radiance scale of a national metrology laboratory, to independently validate the radiances assigned to the laboratory sources of the instrument builders. The EOS Project Science Office also developed a validation program for the measurement of onboard diffuse reflecting plaques, which are also used as radiometric standards for Earth-observing satellite instruments. Summarized results of these validation campaigns, with an emphasis on the current state-of-the-art uncertainties in laboratory radiometric standards, will be presented. Future mission uncertainty requirements, and possible enhancements to the EOS validation program to ensure that those uncertainties can be met, will be presented.

Butler, James J.↗