Quick Look Analysis of TM Data of the Washington, District of Columbia Area

A fixed factor analysis-of-variance (ANOVA) approach was used to quantify the impact of each TM sensor characteristic (spectral, spatial, and radiometric resolutions) on classification accuracy. All assessments were made relative to MSS sensor characteristics, and the impact of each characteristic was assessed individually, and in all possible combinations. Thematic Mapper data acquired over the Washington, D.C. area on November 2, 1982 were utilized to conduct the experiment. The following results were obtained: the reduction of quantization level from eight bits to six bits caused a decrease in overall accuracy (7%); the use of only three bands (TM 2, 3 and 4) covering the isible and near infrared portion of the spectrum caused a decrease in overall accuracy (7%); and the decrease in spatial resolution resulted in an increase in overall accuracy (4%). Results indicate that the increased radiometric and spectral resolution of the TM instrument do provide increased information content. The result of the spatial resolution degradation is somewhat misleading, in that the result is more a function of spatial resolution.

Williams, D. L.↗

A portable spectrometer for use from 5 to 15 micrometers

A field portable spectrometer suitable for collecting data relevant to remote sensing applications in the 8 to 12 micrometer atmospheric window has been built at the Jet Propulsion Laboratory. The instrument employs a single cooled HgCdTe detector and a continuously variable filter wheel analyzer. The spectral range covered is 5 to 14.5 micrometers and the resolution is approximately 1.5 percent of the wavelength. A description of the hardware is followed by a discussion of the analysis of the spectral data leading to finished emissivity and radiance spectra. A section is devoted to the evaluation of the instrument performance with respect to spectral resolution, radiometric precision, and accuracy. Several examples of spectra acquired in the field are included.

Hoover, G.↗

A thermal emission spectrometer for field use

A field portable spectrometer has been built at the Jet Propulsion Laboratory which is suitable for collecting data relevant to remote sensing applications in the 4.7- to 5.6- and 8- to 12-micrometer atmospheric windows. The instrument employs a single cooled HgCdTe detector and a continuously variable filter wheel analyzer. The spectral range covered is 5- to 14.5-micrometers and the resolution is approximately 1.5 percent of the wavelength. A description of the hardware is followed by a discussion of the data processing steps leading to emissivity and radiance spectra. A section is devoted to the evaluation of the instrument performance with respect to spectral resolution, radiometric precision, and accuracy. Several examples of spectra acquired in the field are included.

Hoover, Gordon↗

Validation of the CERES Shortwave Measurements over Desert and Cloud Scenes

The Clouds and the Earth's Radiant Energy System (CERES) broadband shortwave channel, 0.3 - 5 micron, measures atmosphere and surface reflected solar radiation. CERES provides an in-flight tungsten lamp to monitor the shortwave radiometric stability over the lifetime of the instrument. Initial Tropical Rainfall Measurement Mission (TRMM) tungsten calibration results indicate a 0.6% change over the first six months of mission life. The three channel intercomparison technique and the solar diffuser calibration results show shortwave stabilities of 0.2% and 0.3% for the same time period. Current belief is that the tungsten lamp, not the radiometer, has drifted. Radiometers, optics, and onboard calibrators exposed to the harsh space environment often degrade. Independent validation studies based on bright Earth viewing measurements are necessary to support the in-flight filtered calibration results. Instrument measurements of filtered radiances are

Currey, Chris↗

Measurement Sets and Sites Commonly Used for High Spatial Resolution Image Product Characterization

Scientists within NASA's Applied Sciences Directorate have developed a well-characterized remote sensing Verification & Validation (V&V) site at the John C. Stennis Space Center (SSC). This site has enabled the in-flight characterization of satellite high spatial resolution remote sensing system products form Space Imaging IKONOS, Digital Globe QuickBird, and ORBIMAGE OrbView, as well as advanced multispectral airborne digital camera products. SSC utilizes engineered geodetic targets, edge targets, radiometric tarps, atmospheric monitoring equipment and their Instrument Validation Laboratory to characterize high spatial resolution remote sensing data products. This presentation describes the SSC characterization capabilities and techniques in the visible through near infrared spectrum and examples of calibration results.

Pagnutti, Mary↗

A Dual-Polarized, Dual-Frequency, Corrugated Feed Horn for SMAP

SMAP will be the first Earth science mission to use a deployable 6m mesh reflector for both radar and radiometric measurements from low Earth orbit. The instrument antenna will spin at about 14 rpm, making the design of both reflector and feed more challenging. While the performance requirements imposed by the radar instrument are relatively benign, those pertinent to the radiometer are more difficult to meet. Extreme care was necessary in designing the feed, especially from a performance stability perspective. Thermal variations due to the spacecraft going in and out of eclipse during orbit and direct solar radiation into the horn are just two of the challenges faced during the design phase. In this paper, the basic concepts behind the design of SMAP's feed will be discussed. Each component of the feed will be analyzed in detail with particular emphasis on its impact on major RF requirements. Overall performance of the feed will also be discussed.

deployable reflector↗

Dual-Telescope Multi-Channel Thermal-Infrared Radiometer for Outer Planet Fly-By Missions

The design of a versatile dual-telescope thermal-infrared radiometer spanning the spectral wavelength range 8-200 microns, in five spectral pass bands, for outer planet fly-by missions is described. The dual- telescope design switches between a narrow-field-of-view and a wide-field-of-view to provide optimal spatial resolution images within a range of spacecraft encounters to the target. The switchable dual-field- of-view system uses an optical configuration based on the axial rotation of a source-select mirror along the optical axis. The optical design, spectral performance, radiometric accuracy, and retrieval estimates of the instrument are discussed. This is followed by an assessment of the surface coverage performance at various spatial resolutions by using the planned NASA Europa Mission 13-F7 fly-by trajectories as a case study.

Aslam, Shahid↗

Calibrating CERES and VIIRS using CLARREO Pathfinder: Adjustment for the Viewing Geometry Mismatch

The Climate Absolute Radiance and Refractivity Observatory Pathfinder (CPF) mission on the International Space Station (ISS) will provide, for the first-time, an SI-traceable on-orbit calibration reference with a reflectance uncertainty of 0.3% (1 sigma). One major mission objective is to demonstrate the capability of transferring CPF’s radiometric accuracy to other satellite-based instruments, such as Clouds and Earth's Radiant Energy System (CERES) and Visible Infrared Imaging Radiometer Suite (VIIRS) on NOAA-20. CPF inter-calibration measurements will be planned to obtain inter-calibration samples that closely match satellite-based target sensor observations in time, space, angle, and wavelength. The inter-calibration event observations cover a wide range of viewing geometry angles with potential angular mismatch between CPF and the target sensors which can introduce non-negligible errors against the mission’s inter-calibration uncertainty budget. We will introduce the CPF approach to adjust for angular mismatch differences, thereby reducing the incurred uncertainties to within the inter-calibration uncertainty budget. The angular adjustment algorithm has been developed and validated based on the high-fidelity simulations of the CPF spectra using the Principal Component based Radiative Transfer Model (PCRTM). The implementation of the algorithm on event simulation data and the characterization for the angular adjustment uncertainty will be presented.

Wan Wu↗

Failure of the ERBE scanner instrument aboard NOAA 10 spacecraft and results of failure analysis

The Earth Radiation Budget Experiment (ERBE) scanner instrument on the NOAA 10 spacecraft malfunctioned on May 22, 1989, after more than 4 years of in-flight operation. After the failure, all instrument operational mode commands were tested and the resulting data analyzed. Details of the tests and analysis of output data are discussed therein. The radiometric and housekeeping data appear to be valid. However, the instrument will not correctly execute operational scan mode commands or the preprogrammed calibration sequences. The data indicate the problem is the result of a failure in the internal address decoding circuity in one of the ROM (read only memory) chips of the instrument computer.

Miller, J. B.↗

Reducing Uncertainty in the AIRS Radiometric Calibration

The Atmospheric Infrared Sounder (AIRS) radiometric calibration coefficients convert the counts measured from the instruments A/D converters (Level 1A) to SI traceable radiance units (Level 1B). The calibration equations are based on how the instrument operates and follow a simple second order relationship between counts and radiance. Terms are included to account for nonlinearity of the detectors, emissivity and temperature knowledge of the on-board calibrator (OBC) blackbody and radiometric offset due to coupling of the polarization of the scan mirror with the spectrometer. In this paper, we re-derive the radiometric calibration equation with a little more rigor and account for the view angle of each of the 4 space views. We then derive new polarization coefficients from the 4 space views over the mission and use them re-derive the coefficients for blackbody emissivity and nonlinearity. We then compare new coefficients (Version 7k) with the latest operational version of the AIRS radiometric calibration coefficients (Version 5). The AIRS Version 5 coefficients were sufficiently adequate that an update has never been made since AIRS launch in 2002. However, it can be seen, when we compare to the Cross-track Infrared Sounder (CrIS), that better agreement is made in Version 7. The impact of the new coefficients is highest at cold scene temperatures and very warm temperatures.

Strow, Larrabee↗

Progress of the NASA ACE Mission Polarimeter Working Group Instrument Inter-Comparison

The NASA Aerosol-Cloud-Ecosystem (ACE) mission is a National Research Council Decadal Survey recommended mission that will contain an imaging polarimeter for remote sensing of aerosols and clouds. A variety of airborne polarimeter prototypes exist, so the ACE Polarimeter Working Group (ACEPWG) was formed to share information between groups and collectively work for improved measurement techniques, uncertainty characterization, and algorithm development. The initial focus has been on observations made during the Polarimeter Definition Experiment (PODEX), conducted in early 2013 in Southern California. Three ACE mission supported polarimeters were deployed on the high altitude ER-2 aircraft as it flew over a variety of targets. Two of those instruments to date have successfully produced Level 1 (geolocated radiance and polarization) data. Initial matched scene inter-comparisons found little radiometric, but significant polarimetric, bias. After improvement to geolocation in one instrument, and calibration in the other, polarimetric comparisons have improved significantly. We will describe these results, remaining unresolved issues, and future plans.

Polarimeter↗

State of The Art Radiometer Standards For NASA'S Earth Observing System

The Multi-Angle Imaging SpectroRadiometer (MISR), to be launched in 1998, is one of five instruments on NASA's first Earth Observing System (EOS) platform. The 3% absolute radiometric calibration requirement is considered challenging, particularly since it must be maintained through the five-year mission life. The Instrument requirements have led to the development of an On-Board Calibrator (OBC) consisting of diffuse panels and photodiode-based radiometric standards.

SpectroRadiometer↗

Radiometric Quality of the MODIS Bands at 667 and 678nm

The MODIS instruments on Terra and Aqua were designed to allow the measurement of chlorophyll fluorescence effects over ocean. The retrieval algorithm is based on the difference between the water-leaving radiances at 667nm and 678nm. The water-leaving radiances at these wavelengths are usually very low relative to the top- of-atmosphere radiances. The high radiometric accuracy needed to retrieve the small fluorescence signal lead to a dual gain design for the 667 and 678nm bands. This paper discusses the benefits obtained from this design choice and provides justification for the use of only one set of gains for global processing of ocean color products. Noise characteristics of the two bands and their related products are compared to other products of bands from 412nm to 2130nm. The impact of polarization on the two bands is discussed. In addition, the impact of stray light on the two bands is compared to other MODIS bands.

Meister, Gerhard↗

Radiometric Quality of the MODIS Bands at 667 and 678nm

The MODIS instruments on Terra and Aqua were designed to allow the measurement of chlorophyll fluorescence effects over ocean. The retrieval algorithm is based on the difference between the water-leaving radiances at 667nm and 678nm. The water-leaving radiances at these wavelengths are usually very low relative to the top-of-atmosphere radiances. The high radiometric accuracy needed to retrieve the small fluorescence signal lead to a dual gain design for the 667 and 678nm bands. This paper discusses the benefits obtained from this design choice and provides justification for the use of only one set of gains for global processing of ocean color products. Noise characteristics of the two bands and their related products are compared to other products of bands from 412nm to 2130nm. The impact of polarization on the two bands is discussed. In addition, the impact of stray light on the two bands is compared to other MODIS bands.

Meister, Gerhard↗

Fundamentals of absolute pyroheliometry and objective characterization

The radiometric methodology in use with a narrow field of view radiometer for observation of the solar constant is described. The radiation output of the Sun is assumed to be constant, enabling the monitoring of the solar source by an accurately pointed radiometer, and the Sun's output is measured as a function of time. The instrument is described, its angular response considered, and principles for absolute radiometric measurement presented. Active modes of operation are analyzed, taking into consideration instrumental perturbations and sensor efficiency, heating wire effect, cavity sensor efficiency, thermal effects on the surface of the sensitive area, the effect of the field of view limiting system, and the frequency response of the heat flux detector and absolute radiometric system. Performance of absolute measurements with relatively high accuracy is demonstrated.

Crommelynck, D. A.↗

GOME Calibration and Validation Using Backscatter UV Techniques

GOME radiance, irradiance, and ozone products were validated by NASA Goddard Space Flight Center through three tasks which included, pre-launch calibration comparisons with SBUV and TOMS radiometric standards, validation of GOME Level-1 irradiance and radiance and Level 2 total ozone data products using SBUV/2 and TOMS algorithms and data, and studies of GOME data using the Goddard radiative transfer code. The prelaunch calibration using the NASA large aperture integrating sphere was checked against that provided by TPD. Agreement in the calibration constants, derived in air, between the Goddard and TPD system were better than 3%. Validation of Level-1 irradiance data included comparison of GOME and SSBUV and the UARS solar irradiances measurements. Large wavelength dependent differences, as high as 10%, were noted between GOME and the US instruments. This discrepancy has now been attributed to radiometric sensitivity changes experienced by GOME when operating in a vacuum. GOME Earth radiance data were then compared to the NOAA-14 SBUV/2 radiances. These results show that between 340 and 400 nm the differences in GOME and SBUV/2 data are less than 5% with some wavelength dependence. At wavelengths shorter than 300 nm, differences are of the order of 10% or more where the GOME radiances are larger. To test GOME DOAS retrieved total ozone values, these values were compared with ozone amounts retrieved using GOME radiances in the TOMS version-7 algorithm. The differences showed a solar zenith angle dependence ranging from 0 to 10% where the TOMS algorithm values were higher. GOME radiances below 300 nm were further validated by selecting radiances at wavelengths normally used by SBUV and processing them through the SBUV ozone profile algorithm and then compared to climatological values. The GOME ozone profiles ranged from 10-30% lower over altitude compared to climatological values. This is consistent with the offsets detected in the SBUV/2 radiance comparisons at wavelengths shorter than 300 nm.

Hilsenrath, E.↗

Snow Crystal Shape and Microwave Scattering

The radiometric calibration of SeaWiFS data includes a correction for the temperature dependence of the individual detector sensitivities. The detector temperature are measured by temperature sensors mounted on instrument focal planes. Processing of the temperature sensor output by an onboard instrument computer introduces a nonlinear response into the temperature data. This paper describes the calibration of the temperature sensor output and the computation of the temperature corrections for the radiometric calibration of the instrument.

Foster, J. L.↗

MODIS Solar Calibration Simulation Assisted Refinement

A detailed optical radiometric model has been created of the MODIS instruments solar calibration process. This model takes into account the orientation and distance of the spacecraft with respect to the sun, the correlated motions of the scan mirror and the sun, all of the optical elements, the detector locations on the visible and near IR focal planes, the solar diffuser and the attenuation screen with all of its hundreds of pinholes. An efficient computational scheme, takes into account all of these factors and has produced results which reproduce the observed time dependent intensity variations on the two focal planes with considerable fidelity. This agreement between predictions and observations, has given insight to the causes of some small time dependent variations and how to incorporate them into the overall calibration scheme. The radiometric model is described and modeled and actual measurements are presented and compared.

Waluschka, Eugene↗