Search NASA⌕ Search

SEARCH · Search NASA

Results for “rapid adjustments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Preparation of Thick NI/AL Reactive Multilayer Films and Prospective Use for Self-Powered Brazing of TI-6AL-4V

In this study we demonstrate a new method for depositing thick reactive multilayer films (RMFs) (thickness > 14 µm) by using Ti interlayer integration and substrate preheating during fabrication. These two adjustments are designed to alleviate internal planar stresses that cause delamination between deposited layers and peeling off the substrate. Decreasing the distance between Ti interlayers helps to eliminate delamination between deposited layers. Through high speed camera measurements, the reaction propagation speed of an RMF sample with preheating is 42% slower than the same RMF that was not preheated, indicating a slower heat release rate. The preliminary experiments on brazing Ti-6Al-4V coated with BAlSi-4 brazing material revealed dendritic structure branching out from the RMF surface into the brazing material. The dendrite structures most likely form because of rapid melting and solidification of the brazing material. However, this rapid melting and solidification cycle does not appear to occur uniformly across the BAlSi-4RMF interface which is linked to its low bonding strength. When the Ti-6Al-4V substrate is heated to 150 °C prior to ignition, the strength increases to 0.47 MPa when the total RMF thickness is 84 µm and 15 MPa of pressure is applied.

Cheng, Jinquan↗

Mean flow and noise measurements in a Mach 3.5 pilot quiet tunnel

The use of Mach 3.5 two-dimensional rapid expansion nozzle for wind tunnel testing at supersonic speeds and low noise conditions encountered in high altitude flights is described. The supersonic pilot quiet tunnel is located at the NASA Langley Research Center and a description of the facility is provided, along with instrumentation and noise measurement test data at 30, 50, and 75 psia. The mean pitot pressure distributions, rms noise levels, the effect of unit Reynolds number, wall waviness, wall contaminants, and the effects of closing the bleed valve are analyzed. Typical laminar and turbulent spectra are presented, along with a summary of the effect of slot throat adjustment on the power spectra. Comparisons are made of the power spectra with the bleed valve open and closed, and of the rms fluctuating pressures with levels from conventional nozzles, and the performance capabilities are evaluated for use in transition studies.

Beckwith, I. E.↗

Space Exploration Technologies Developed through Existing and New Research Partnerships Initiatives

The Space Partnership Development Program of NASA has been highly successful in leveraging commercial research investments to the strategic mission and applied research goals of the Agency through industry academic partnerships. This program is currently undergoing an outward-looking transformation towards Agency wide research and discovery goals that leverage partnership contributions to the strategic research needed to demonstrate enabling space exploration technologies encompassing both robotic spacecraft missions and human space flight. New Space Partnership Initiatives with incremental goals and milestones will allow a continuing series of accomplishments to be achieved throughout the duration of each initiative, permit the "lessons learned" and capabilities acquired from previous implementation steps to be incorporated into subsequent phases of the initiatives, and allow adjustments to be made to the implementation of the initiatives as new opportunities or challenges arise. An Agency technological risk reduction roadmap for any required technologies not currently available will identify the initiative focus areas for the development, demonstration and utilization of space resources supporting the production of power, air, and water, structures and shielding materials. This paper examines the successes to date, lessons learned, and programmatic outlook of enabling sustainable exploration and discovery through governmental, industrial, academic, and international partnerships. Previous government and industry technology development programs have demonstrated that a focused research program that appropriately shares the developmental risk can rapidly mature low Technology Readiness Level (TRL) technologies to the demonstration level. This cost effective and timely, reduced time to discovery, partnership approach to the development of needed technological capabilities addresses the dual use requirements by the investing partners. In addition, these partnerships help to ensure the attainment of complimenting human and robotic exploration goals for NASA while providing additional capabilities for sustainable scientific research benefiting life and security on Earth.

Nall, Mark↗

Convolutional Neural Networks for Image Classification in Metal Selective Laser Meting Additive Manufacturing

Selective laser melting (SLM) is a metal additive manufacturing process that has several advantages such as the large range of metal materials that can be accommodated, 3D printing of complex shape components, the ability to adjust material properties, and cost reduction as expensive production equipment may not be required. Therefore, process monitoring is crucial in different stages of the component building. In this work, convolutional neural networks (CNNs) are investigated as a suitable technique for post-inspection of builds. The monitoring of manufactured parts was conducted by collecting computed tomography (CT) images and identifying defects. Five CNN models were implemented and tested for the classification of the CT images. The models were based on NASNetMobile and DenseNet121, and a custom built CNN model. The results of this work show that CNNs can be feasible and reliable for rapid monitoring and classification of defects in CT images from build fabrication using SLM.

Rodolfo Ledesma↗

Automated Software for Crewed Spacecraft - Bridging the Gap from Sci Fi to Reality

With a voice command or a few taps on the console, the spacecraft pivots on a dime at high velocity and gently docks to an orbiting space platform. This is the image most people have of the complex software computations and integrated hardware performance necessary for a spacecraft to successfully perform an automated launch, rendezvous, and docking. Today’s reality is that while computer operations are advancing rapidly, science fiction over-simplifies and over-sells current capabilities. This paper discusses the integration of spacecraft computer automation into the operation of one of the United States’ new Commercial Crew vehicles - the Boeing CST-100 Starliner. Lessons learned by the Boeing Mission Operations team, a unique private-public partnership with NASA, from conceptual design through real-time operation of the first test flight will be discussed along with evolution of the system in preparation for the second uncrewed test flight. Focus will center on how operations has learned to use the automated software to their advantage while also knowing how to adjust the automation in response to spacecraft or mission anomalies.

Robert C. Dempsey↗

Electrophoretic Focusing

Electrophoretic focusing is a new method of continuous flow electrophoresis that introduces precision flow control to achieve high resolution separations. The electric field is applied perpendicular to an incoming sample lamina and buffer but also perpendicular to the broad faces of the thin rectangular chamber. A uniform fluid cross-flow then enters and exits the separation chamber through the same broad faces which are porous. A balance is achieved by adjusting either the electric field or the cross-flow so the desired sample fraction with its specific migration velocity encounters an opposing flow of the same velocity. Applying an electric field transverse to the incoming sample lamina and opposing this field with a carefully configured buffer flow, a sample constituent can be selected and focused into a narrow stream for subsequent analysis. Monotonically changing either electric field or buffer cross-flow will yield a scan of all constituents of the sample. Stopping the scan increases the collection time for minor constituents to improve their analysis. Using the high voltage gradients and/or cross-flow to rapidly deflect extraneous sample through the porous screens and into either of the side (purge) chambers, the selected sample is focused in the center plane of the separation chamber and collected without contact or interaction with the separation chamber walls. Results will be presented on the separation of a range of materials including dyes, proteins, and monodisperse polystyrene latexes. Sources of sample dispersion inherent in other electrokinetic techniques will be shown to be negligible for a variety of sample concentrations, buffer properties and operating conditions.

Snyder, Robert S.↗

Development Status of the WetLab-2 Project: New Tools for On-orbit Real-time Quantitative Gene Expression.

The primary objective of NASA Ames Research Centers WetLab-2 Project is to place on the ISS a research platform to facilitate gene expression analysis via quantitative real-time PCR (qRT-PCR) of biological specimens grown or cultured on orbit. The WetLab-2 equipment will be capable of processing multiple sample types ranging from microbial cultures to animal tissues dissected on-orbit. In addition to the logistical benefits of in-situ sample processing and analysis, conducting qRT-PCR on-orbit eliminates the confounding effects on gene expression of reentry stresses and shock acting on live cells and organisms. The system can also validate terrestrial analyses of samples returned from ISS by providing quantitative on-orbit gene expression benchmarking prior to sample return. The ability to get on orbit data will provide investigators with the opportunity to adjust experimental parameters for subsequent trials based on the real-time data analysis without need for sample return and re-flight. Finally, WetLab-2 can be used for analysis of air, surface, water, and clinical samples to monitor environmental contaminants and crew health. The verification flight of the instrument is scheduled to launch on SpaceX-5 in Aug. 2014.Progress to date: The WetLab-2 project completed a thorough study of commercially available qRT-PCR systems and performed a downselect based on both scientific and engineering requirements. The selected instrument, the Cepheid SmartCycler, has advantages including modular design (16 independent PCR modules), low power consumption, and rapid ramp times. The SmartCycler has multiplex capabilities, assaying up to four genes of interest in each of the 16 modules. The WetLab-2 team is currently working with Cepheid to modify the unit for housing within an EXPRESS rack locker on the ISS. This will enable the downlink of data to the ground and provide uplink capabilities for programming, commanding, monitoring, and instrument maintenance. The project is currently designing a module that will lyse the cells and extract RNA of sufficient quality for use in qRT-PCR reactions while using a housekeeping gene to normalize RNA concentration and integrity. Current testing focuses on two promising commercial products and chemistries that allow for RNA extraction with minimal complexity and crew time.

quantitative PCR↗

Further results on cooling mechanisms for soft X-ray flares

Analysis of data from the soft X-ray proportional counter spectrometer on OSO-4 has been continued along the lines of earlier work. It was noticed that the time profiles of X-ray counts from the OSO-4 instrument's 1 to 3 Angstrom detectors for two events showed a very rapid initial decay after maximum, followed by a much more slowly falling section. At least in the case of the larger of the two events, the change of slope seems quite definitely to be discontinuous. Temperatures and emission measures for both flares have been derived, by fitting an emission function to eight-channel count histograms which form the output of the 1 to 3 Angstrom detectors, analyzed into eight energy intervals by pulse-height analysis. The computer program is described. It employs temperature and continuum emission measures in the Culhane-Acton formula and the flux in the 6.7 KeV iron-line feature as free parameters, adjusting them by small amounts in successive iterations until the original historgram is approximately reproduced. A chi-squared is used to examine the agreement between histograms and terminates the iteration accordingly. Account is taken of the proportional counters' energy resolution in the fitting process.

Craig, I. J. D.↗

Production of superconductor/carbon bicomponent fibers

Certain materials are unable to be drawn or spun into fiber form due to their improper melting characteristics or brittleness. However, fibrous samples of such materials are often necessary for the fabrication of intricate shapes and composites. In response to this problem, a unique process, referred to as the piggyback process, was developed to prepare fibrous samples of a variety of nonspinnable ceramics. In this technique, specially produced C-shaped carbon fibers serve as micromolds to hold the desired materials prior to sintering. Depending on the sintering atmosphere used, bicomponent or single component fibers result. While much has been demonstrated worldwide concerning the YBa2Cu3O(7-x) superconductor, fabrication into unique forms has proven quite difficult. However, a variety of intricate shapes are necessary for rapid commercialization of the superconducting materials. The potential for producing fibrous samples of the YBa2Cu3O(7-x) compound by the piggyback process is being investigated. Various organic and acrylic materials were investigated to determine suspending ability, reactivity with the YBa2Cu3O(7-x) compound during long term storage, and burn out characteristics. While many questions were answered with respect to the interfacial reactions between YBa2Cu3O(7-x) and carbon, much work is still necessary to improve the quality of the sintered material if the fibers produced are to be incorporated into useful composites or cables. Additional research is necessary to evaluate quality of the barrier layer during long soakings at the peak temperature; adjust the firing schedule to avoid microcracking and improve densification; and increase the solids loading in the superconductive suspension to decrease porosity.

Wise, S. A.↗

Next Generation Life Support Project Status

Next Generation Life Support (NGLS) is one of several technology development projects sponsored by NASA s Game Changing Development Program. The NGLS Project is developing life support technologies (including water recovery and space suit life support technologies) needed for humans to live and work productively in space. NGLS has three project tasks: Variable Oxygen Regulator (VOR), Rapid Cycle Amine (RCA) swing bed, and Alternative Water Processor (AWP). The RCA swing bed and VOR tasks are directed at key technology needs for the Portable Life Support System (PLSS) for an Advanced Extravehicular Mobility Unit, with focus on test article development and integrated testing in an Advanced PLSS in cooperation with the Advanced Extra Vehicular Activity (EVA) Project. An RCA swing-bed provides integrated carbon dioxide removal and humidity control that can be regenerated in real time during an EVA. The VOR technology will significantly increase the number of pressure settings available to the space suit. Current space suit pressure regulators are limited to only two settings whereas the adjustability of the advanced regulator will be nearly continuous. The AWP effort, based on natural biological processes and membrane-based secondary treatment, will result in the development of a system capable of recycling wastewater from sources expected in future exploration missions, including hygiene and laundry water. This paper will provide a status of technology development activities and future plans.

Barta, Daniel J.↗

Crashworthy Seats Would Afford Superior Protection

Seats to prevent or limit crash injuries to astronauts aboard the crew vehicle of the Orion spacecraft are undergoing development. The design of these seats incorporates and goes beyond crash-protection concepts embodied in prior spacecraft and racing-car seats to afford superior protection against impacts. Although the seats are designed to support astronauts in a recumbent, quasi-fetal posture that would likely not be suitable for non-spacecraft applications, parts of the design could be adapted to military and some civilian aircraft seats and to racing car seats to increase levels of protection. The main problem in designing any crashworthy seat is to provide full support of the occupant against anticipated crash and emergency-landing loads so as to safely limit motion, along any axis, of any part of the occupant s body relative to (1) any other part of the occupant s body, (2) the spacecraft or other vehicle, and (3) the seat itself. In the original Orion spacecraft application and in other applications that could easily be envisioned, the problem is complicated by severe limits on space available for the seat, a requirement to enable rapid egress by the occupant after a crash, and a requirement to provide for fitting of the seat to a wide range of sizes and shapes of a human body covered by a crash suit, space suit, or other protective garment. The problem is further complicated by other Orion-application-specific requirements that must be omitted here for the sake of brevity. To accommodate the wide range of crewmember body lengths within the limits on available space in the original Orion application, the design provides for taller crewmembers to pull their legs back closer toward their chests, while shorter crewmembers can allow their legs to stretch out further. The range of hip-support seat adjustments needed to effect this accommodation, as derived from NASA s Human Systems Integration Standard, was found to define a parabolic path along which the knees must be positioned. For a given occupant, the specific position along the path depends on the distance from the heel to the back of the knee. The application of the concept of parabolic adjustment of the hip-support structure caused the seat pan to also take on a parabolic shape, yielding the unanticipated additional benefit that the seat pan fits the occupant s buttocks and thighs more nearly conformally than do seat pans of prior design. This more nearly conformal fit effectively eliminates a void between the occupant s body and the seat pan, thereby helping to prevent what, in prior seat designs, was shifting of the occupant s body into that void during an impact.

Gohmert, Dustin↗

Properties of nearby interstellar hydrogen deduced from Lyman-alpha sky background measurements

For a sufficiently rapid relative motion of the solar system and the nearby interstellar gas, neutral atoms may be expected to penetrate the heliosphere before becoming ionized. Recent satellite measurements of the Lyman alpha emission above the geocorona indicate such an interstellar wind of neutral hydrogen emerging from the direction of Sagittarius and reaching to within a few astronomical units of the sun. A detailed model of the scattering of solar Lyman alpha from the spatial distribution of neutral hydrogen in interplanetary space is presented. This asymmetric distribution is established by solar wind and solar ultraviolet ionization processes along the trajectories of the incoming hydrogen atoms. The values of the interstellar density, the relative velocity, and the gas temperature are adjusted to agree with the Lyman alpha measurements. The results may be interpreted in terms of two models, the cold model and the hot model of the interstellar gas, depending on whether galactic Lyman alpha emission is present at its maximum allowable value or negligibly small.

Thomas, G. E.↗

Comparison of Computational Approaches for Rapid Aerodynamic Assessment of Small UAVs

Computational Fluid Dynamic (CFD) methods were used to determine the basic aerodynamic, performance, and stability and control characteristics of the unmanned air vehicle (UAV), Kahu. Accurate and timely prediction of the aerodynamic characteristics of small UAVs is an essential part of military system acquisition and air-worthiness evaluations. The forces and moments of the UAV were predicted using a variety of analytical methods for a range of configurations and conditions. The methods included Navier Stokes (N-S) flow solvers (USM3D, Kestrel and Cobalt) that take days to set up and hours to converge on a single solution; potential flow methods (PMARC, LSAERO, and XFLR5) that take hours to set up and minutes to compute; empirical methods (Datcom) that involve table lookups and produce a solution quickly; and handbook calculations. A preliminary aerodynamic database can be developed very efficiently by using a combination of computational tools. The database can be generated with low-order and empirical methods in linear regions, then replacing or adjusting the data as predictions from higher order methods are obtained. A comparison of results from all the data sources as well as experimental data obtained from a wind-tunnel test will be shown and the methods will be evaluated on their utility during each portion of the flight envelope.

Shafer, Theresa C.↗

Transitioning a Fundamental Research Program to Align with the NASA Exploration Initiative-Perspectives from Microgravity Combustion Science and Fluid Physics

A new Vision for Space Exploration was announced earlier this year by U.S. President George W. Bush. NASA has evaluated on-going programs for strategic alignment with this vision. The evaluation proceeded at a rapid pace and is resulting in changes to the scope and focus of experimental research that will be conducted in support of the new vision. The existing network of researchers in the physical sciences - a highly capable, independent, and loosely knitted community - typically have shared conclusions derived from their work within appropriate discipline-specific peer reviewed journals and publications. The initial result of introducing this Vision for Space Exploration has been to shift research focus from a broad coverage of numerous, widely varying topics into a research program focused on a nearly-singular set of supporting research objectives to enable advances in space exploration. Two of these traditional physical science research disciplines, Combustion Science and Fluid Physics, are implementing a course adjustment from a portfolio dominated by "Fundamental Science Research" to one focused nearly exclusively on supporting the Exploration Vision. Underlying scientific and engineering competencies and infrastructure of the Microgravity Combustion Science and Fluid Physics disciplines do provide essential research capabilities to support the contemporary thrusts of human life support, radiation countermeasures, human health, low gravity research for propulsion and materials and, ultimately, research conducted on the Moon and Mars. A perspective on how these two research disciplines responded to the course change will be presented. The relevance to the new NASA direction is provided, while demonstrating through two examples how the prior investment in fundamental research is being brought to bear on solving the issues confronting the successful implementation of the exploration goals.

Sutliff, Thomas J.↗

Preliminary Investigation of an Active PLZT Lens

The design, analysis and preliminary testing of a prototype Adjustable Focus Optical Correction Lens (AFOCL) is described. The AFOCL is an active optical component composed of solid state lead lanthanum-modified zirconate titanate (PLZT) ferroelectric ceramic with patterned indium tin oxide (ITO) transparent surface electrodes that modulate the refractive index of the PLZT to function as an electro-optic lens. The AFOCL was developed to perform optical re-alignment and wavefront correction to enhance the performance of Ultra-Lightweight Structures and Space Observatories (ULSSO). The AFOCL has potential application as an active optical component within a larger optical system. As such, information from a wavefront sensor would be processed to provide input to the AFOCL to drive the sensed wavefront to the desired shape and location. While offering variable and rapid focussing capability (controlled wavefront manipulation) similar to liquid crystal based spatial light modulators (SLM), the AFOCL offers some potential advantages because it is a solid-state, stationary, low-mass, rugged, and thin optical element that can produce wavefront quality comparable to the solid refractive lens it replaces. The AFOCL acts as a positive or negative lens by producing a parabolic phase-shift in the PLZT material through the application of a controlled voltage potential across the ITO electrodes. To demonstrate the technology, a 4 mm diameter lens was fabricated to produce 5-waves of optical power operating at 2.051 micrometer wavelength. Optical metrology was performed on the device to measure focal length, optical quality, and efficiency for a variety of test configurations. The data was analyzed and compared to theoretical data available from computer-based models of the AFOCL.

Lightsey, W. D.↗

New Padded Harness for Self-Acquisition of Resting 12-Lead ECGs

We have developed a dry-electrode harness that permits easy, rapid, and unsupervised self-acquisition of resting 12-lead ECGs without the use of any disposables. Various other advantageous features of the harness include: 1) padded or inflatable cushions at the lateral sides of the torso that function to press the left arm (LA) and right arm (RA) dry electrodes mounted on cushions against sideward (as shown in the Figure below) or downward-rested arms of the subject; 2) sufficient distal placement of the arm electrodes with good abutment and without the need for adhesives, straps, bands, bracelets, or gloves on the arms; 3) padding over the sternum to avoid "tenting" in the V1 through V3 (and V3R, when present) electrode positions; 4) easy-to-don, one-piece design with an adjustable single point of connection and an adjustable shoulder strap; and 5) Lund or "modified Lund" placement of the dry electrodes, the results of which more effectively reproduce results from "standard" 12-lead ECG placements than do results from Mason-Likar lead placements.

Schlegel, T. T.↗

FRET-Aptamer Assays for Bone Marker Assessment, C-Telopeptide, Creatinine, and Vitamin D

Astronauts lose 1.0 to 1.5% of their bone mass per month on long-duration spaceflights. NASA wishes to monitor the bone loss onboard spacecraft to develop nutritional and exercise countermeasures, and make adjustments during long space missions. On Earth, the same technology could be used to monitor osteoporosis and its therapy. Aptamers bind to targets against which they are developed, much like antibodies. However, aptamers do not require animal hosts or cell culture and are therefore easier, faster, and less expensive to produce. In addition, aptamers sometimes exhibit greater affinity and specificity vs. comparable antibodies. In this work, fluorescent dyes and quenchers were added to the aptamers to enable pushbutton, one-step, bind-and-detect fluorescence resonance energy transfer (FRET) assays or tests that can be freeze-dried, rehydrated with body fluids, and used to quantitate bone loss of vitamin D levels with a handheld fluorometer in the spacecraft environment. This work generated specific, rapid, one-step FRET assays for the bone loss marker C-telopeptide (CTx) when extracted from urine, creatinine from urine, and vitamin D congeners in diluted serum. The assays were quantified in nanograms/mL using a handheld fluorometer connected to a laptop computer to convert the raw fluorescence values into concentrations of each analyte according to linear standard curves. DNA aptamers were selected and amplified for several rounds against a 26- amino acid form of CTx, creatinine, and vitamin D. The commonalities between loop structures were studied, and several common loop structures were converted into aptamer beacons with a fluorophore and quencher on each end. In theory, when the aptamer beacon binds its cognate target (CTx bone peptide, creatinine, or vitamin D), it is forced open and no longer quenched, so it gives off fluorescent light (when excited) in proportion to the amount of target present in a sample. This proportional increase in fluorescence is called a "lights on" FRET response. The vitamin D aptamer beacon gives a "lights off" or inversely proportional fluorescence response to the amount of vitamin D present in diluted serum. These FRET-aptamer assays are rapid (<30 minutes), sensitive (low ng/mL detection limits), and quite easy to carry out (add sample, mix, and detect in the handheld reader). Benefits include the speed of the assays as well as the small amount of space taken up by the handheld reader and cuvette assays. The aptamer DNA sequences represent novel additional features of the existing (patent-pending) FRET-aptamer assay platform.

Bruno, John G.↗

Forecasting Sensorimotor Adaptability from Baseline Inter-Trial Correlations

One of the greatest challenges surrounding adaptation to the spaceflight environment is the large variability in symptoms, and corresponding functional impairments, from one crewmember to the next. This renders preflight training and countermeasure development difficult, as a "one-size-fits-all" approach is inappropriate. Therefore, it would be highly advantageous to know ahead of time which crewmembers might have more difficulty adjusting to the novel g-levels inherent to spaceflight. Such knowledge could guide individually customized countermeasures, which would enable more efficient use of crew time, both preflight and inflight, and provide better outcomes. The primary goal of this project is to look for a baseline performance metric that can forecast sensorimotor adaptability without exposure to an adaptive stimulus. We propose a novel hypothesis that considers baseline inter-trial correlations, the trial-to-trial fluctuations in motor performance, as a predictor of individual sensorimotor adaptive capabilities. To-date, a strong relationship has been found between baseline inter-trial correlations and adaptability in two oculomotor systems. For this project, we will explore an analogous predictive mechanism in the locomotion system. METHODS: Baseline Inter-trial Correlations: Inter-trial correlations specify the relationships among repeated trials of a given task that transpire as a consequence of correcting for previous performance errors over multiple timescales. We can quantify the strength of inter-trial correlations by measuring the decay of the autocorrelation function (ACF), which describes how rapidly information from past trials is "forgotten." Processes whose ACFs decay more slowly exhibit longer-term inter-trial correlations (longer memory processes), while processes whose ACFs decay more rapidly exhibit shorterterm inter-trial correlations (shorter memory processes). Longer-term correlations reflect low-frequency activity, which is more easily measured in the frequency domain. Therefore, we use the power spectrum (PS), which is the Fourier transform of the ACF, to describe our inter-trial correlations. The decay of the PS yields a straight line on a log-log frequency plot, which we quantify by Beta = - (slope of PS on log-log axes). Hence, Beta is a measure of the strength of inter- trial correlations in the baseline data. Larger Beta values are indicative of longer inter-trial correlations. Experimental Approach: We will begin by performing a retrospective analysis of treadmill-gait adaptation data previously collected by Dr. Bloomberg and colleagues. Specifically, we will quantify the strength of inter-trial correlations in the baseline step cadence and heart rate data and compare it to the locomotor adaptability performance results already described by these investigators. Incorporating these datasets will also allow us to explore the applicability of (and potential limitations surrounding) the use of Beta in forecasting physiological performance. We will also perform a new experiment, in which Beta will be derived from baseline data collected during over-ground (non-treadmill) walking, which will enable us to consider locomotor performance, through the parameter Beta, under the most functionallyrelevant, natural gait condition. This experiment will incorporate two baseline and five post-training over-ground locomotion tests to explore the consistency and potential adaptability of the Beta values themselves. HYPOTHESES: We hypothesize that the strength of baseline inter-trial correlations of step cadence and heart rate will relate to locomotor adaptability. Specifically, we anticipate that individuals who show weaker longer-term inter-trial correlations in baseline step cadence data will be the better adaptors, as step cadence can be modified in real-time (i.e., online corrections are an inherent property of the locomotor system; analogous to results observed in the VOR). Conversely, because heart rate is not altered mid-beat, we expect that individuals who demonstrate stronger longer-term correlations in heart rate will be the better adaptors (analogous to results observed in the saccadic system). CONCLUSIONS: At the conclusion of this project we hope to uncover a baseline predictor of locomotor adaptability. If our hypotheses hold true, our results will demonstrate that the temporal structure of baseline behavioral data contains important information that may aid in forecasting adaptive capacities. The ability to predict such adaptability in the sensorimotor system has significant implications for spaceflight, where astronauts must adjust their motor programs following a change in g-level to retain movement accuracy.

Beaton, K. H.↗