Search NASA⌕ Search

SEARCH · Search NASA

Results for “relative humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Mechanistic modeling of copper corrosions in data center environments

Air-side economizers are increasingly used to take advantage of “free-cooling” in data centers with the intent of reducing the carbon footprint of buildings. However, they can introduce outdoor pollutants to indoor environment of data centers and cause corrosion damage to the information technology equipment. Here, to evaluate the reliability of information technology equipment under various thermal and air-pollution conditions, a mechanistic model based on multi-ion transport and chemical reactions was developed. The model was used to predict Cu corrosion caused by Cl2-containing pollutant mixtures. It also accounted for the effects of temperature (25 °C and 28 °C), relative humidity (50%, 75%, and 95%), and synergism. It also identified higher air temperature as a corrosion barrier and higher relative humidity as a corrosion accelerator, which agreed well with the experimental results. The average root mean square error of the prediction was 13.7 Å. The model can be used to evaluate the thermal guideline for data centers design and operation when Cl2 is present based on pre-established acceptable risk of corrosion in data centers’ environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Attributing human mortality from fire PM 2.5 to climate change

Climate change intensifies fire smoke, emitting hazardous air pollutants that impact human health. However, the global influence of climate change on fire-induced health impacts remains unquantified. Here, in this study, we used three well-tested fire-vegetation models in combination with a chemical transport model and health risk assessment framework to attribute global human mortality from fire fine particulate matter (PM 2.5 ) emissions to climate change. Of the 46401 (1960s) –to 98748 (2010s) annual fire PM 2.5 mortalities, 669 (1.2%, 1960s) –to 12566 (12.8%, 2010s) were attributed to climate change. The most substantial influence of climate change on fire mortality occurred in South America, Australia, and Europe, coinciding with decreased relative humidity, and in boreal forests with increased air temperature. Increasing relative humidity lowered fire mortality in other regions, like South Asia. Our study highlights the role of climate change in fire mortality, aiding public health authorities in spatial targeting adaptation measures for sensitive fire-prone areas.

54 ENVIRONMENTAL SCIENCES↗

Long-term ultrasonic monitoring of concrete affected by alkali-silica reaction

This article presents continuous monitoring results of alkali-silica reaction (ASR) development in concrete specimens for over 400 days using ultrasonic testing and expansion measurements. Eight concrete specimens with nonreactive aggregate (Control), reactive coarse aggregate, and reactive fine aggregates were cast with two reinforced confinement conditions. The specimens were conditioned in an environmental chamber with high temperature and humidity (38°C and 90% relative humidity) to accelerate the ASR development. A multichannel ultrasonic monitoring system was developed to collect ultrasonic signals automatically, and the expansions in three directions were measured periodically. Results showed that the relative velocity change could detect the ASR initiation in all reactive specimens and show a correlation with expansion in the early stage. However, these correlations are inconsistent for different ASR specimens, and the velocity change becomes less sensitive to ASR damage in the late stage (after 300 days). Irrecoverable velocity drop was observed during every chamber shutdown period, especially in specimens with higher levels of ASR damage. This phenomenon suggests that the nonlinear ultrasonic response caused by the ambient temperature variation may indicate the ASR damage.

Engineering↗

Long-distance recording of the humidity over the sea

A procedure is developed for long distance recording of humidity over the sea that uses humidity detectors of the sorption type, whose electrical properties depend on the relative humidity of the air. The moisture sensitive material of the hygristor is the organic polymer polyacrylonitryl, deposited on silver electrodes and thermally treated. In the measurements of the relative humidity from 60% to 95%, the resistance of the hygristor varies from several hundred kiloohms to a few kiloohms, and is an essentially nonlinear function of the humidity.

Buklanov, V. V.↗

Developing a Database of Bio-based Materials for Building Envelope Applications

Oak Ridge National Laboratory (ORNL) has been funded by the Department of Energy (DOE) to help accelerate the introduction of building envelope materials that would reduce the carbon footprint of the buildings sector. The DOE’s Building Technologies Office has historically sought to resolve the knowledge gaps regarding the energy efficiency and moisture durability of building envelope systems and to develop the data, guidance, and tools needed to facilitate rapid industry adoption of high-performance, moisture-managed envelope systems. This project will help accelerate the widespread acceptance of a new generation of building materials developed specifically with the intent of reducing the carbon footprint of buildings. We have produced a database of hygrothermal transport properties on low embodied carbon building materials that can be added to energy and durability simulation tools. Properties that were measured include density, heat capacity, thermal conductivity as a function of temperature and relative humidity, moisture dependent permeance, and sorption isotherms as a function of relative humidity. These data sets were measured following consensus national standards using state-of-the-art facilities. The data has been compiled and is being made available to building designers who require these data to assess these new materials in their designs. We will publish the data and seek its addition to reference databases such as the ASHRAE Handbook of Fundamentals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SPARC-IGAC Symposium on Climate-Chemistry Interactions. Climate Feedback by Water Vapor in the Tropical Upper Troposphere

The strong greenhouse forcing by atmospheric water vapor is expected to play an important role in shaping the direction of any future changes in climate. We present calculations that provide a new perspective on the sensitivity of upper tropospheric water vapor to changes in surface temperature. Equilibrium states of our atmospheric model show unambiguously that as the surface warms, changes in the vertical distribution and temperature of detraining air parcels from tropical convection lead to higher water vapor mixing ratios in the upper troposphere. However, the increase in mixing ratio is not as large as the increase in saturation mixing ratio due to warmer environmental temperatures, so that the relative humidity decreases. Our analysis suggests that models that maintain a fixed relative humidity are likely overestimating the magnitude of the water vapor feedback.

Dessler, A. E.↗

CRGTBSO3 TBS Ozone Data

The Tethered Balloon System (TBS) operated for two weeks during a summer IOP of the CoURAGE campaign. This dataset includes data collected from an En-Sci electrochemical cell (ECC) ozonesonde on the TBS. The ozonesonde was connected to an iMet-4RSB radiosonde, and the overall data collected included ozone, relative humidity, temperature, and altitude. The data from the iMet is the same as that found in the TBSMERGED data product. The TBS also had another instrument (iMet XQ2) that collected meteorological data, which may have more accurate relative humidity (RH) data. This ozonesonde data set is intended to complement the TBSMERGED data product, the CRGTBSO3 surface ozone measurements, and the CoURAGE SWARM ozone lidar (TOLNet) measurements from other locations.

Atmospheric relative humidity↗

Changes in SSL Device Efficiency and Optical Performance Under Accelerated Aging Conditions

Lighting application efficiency (LAE) describes the efficient delivery of light from the light source to the lighted task and is viewed as a new frontier—increasing energy savings with solid-state lighting (SSL) technologies. The framework for LAE that is proposed by the U.S. Department of Energy (DOE) consists of four major elements: light source efficiency, optical delivery efficiency, spectral efficiency, and intensity effectiveness. This report focuses on a sampling of the available SSL products that can be broadly defined as having modified spectral output because the method of spectra modification has a significant impact on light source efficiency and long-term optical delivery and spectral efficiencies. This report focused on the changes in light source, optical delivery, and spectral efficiencies that occur during aging of SSL devices. An accelerated stress test (AST) regiment was developed for the devices under test (DUTs) examined in this report to provide insights into how the performance of SSL devices change with aging. The AST protocols demonstrate that the SSL products discussed in this report often reduce light source efficiency to achieve different spectral characteristics. In addition, aging of the optical components (e.g., lenses, solder masks) in SSL devices can produce increased light absorption, which negatively impacts optical delivery efficiency and light source efficiency. The modified spectral outputs of the selected SSL products discussed in this report come in a variety of form factors and achieve enhanced optical performance by using a variety of methods. All of the products examined in this study use mid-power light-emitting diodes (MP-LEDs), although the number, configuration, phosphor content, and light-emitting diode (LED) pump of the MP-LEDs differ. Product MS-1 is a 60-watt (W) replacement A19 lamp with a hermetically sealed glass globe, which contains an embedded optical filter to absorb green and yellow emissions, thereby creating a “sunlike” modified spectrum. Product MS-2 is a 60-W replacement A19 lamp with 30 MP-LEDs, and it uses a violet LED pump, along with green and red phosphor emissions, to produce a “healthy” spectrum. This spectrum omits blue emissions in an effort to reduce melanopic lux. Product MS-3 is an LED module consisting of 21 MP-LEDs that use a violet LED pump, along with blue, green, and red phosphors, to produce a “sunlike” spectrum. Products MS-4 and MS-5 are both 6-inch (in) downlights that use a manual switching mechanism so that users can select application-specific correlated color temperatures before installation. Products MS-4 and MS-5 both contain two LED primaries (2,700 Kelvin [K] and 5,000 K) for spectral tuning. Product MS-4 contains 12 MP-LEDs for each LED primary, and Product MS-5 contains 10 MP-LEDs for each LED primary. This report summarizes the overall findings from up to 8,000 hours (hrs) of AST on the lamp DUTs (Products MS-1 and MS-2); up to 5,000 hrs of AST on the LED light engine DUTs (Product MS-3); and up to 7,000 hrs of AST on the downlight DUTs (Products MS-4 and MS-5). The AST procedures used in this study included a room temperature operational life (RTOL) test, an operational life test conducted at 45 degrees Celsius (°C; 45OL) test, an operational life test conducted at 75°C (75OL), a wet high-temperature operational life test performed at 65°C and 90% relative humidity (6590), and a wet high-temperature operational life test performed at 75°C and 75% relative humidity (7575). The AST procedures used for Products MS-1 and MS-2 were RTOL, 45OL, and 6590. The AST procedures used for Products MS-3, MS-4, and MS-5 were RTOL, 75OL, and 7575. During the ASTs described herein, separate populations of each product (three DUTs in each population for Products MS-1, MS-2, MS-4, and MS-5; four DUTs in each population for Product MS-3) were subjected to power cycling of 1 hr on and 1 hr off. The key findings from this study include the following. Enhanced optical performance came at the cost of reduced light source efficiency for the lamps and light engines examined in this study. The optical filter used to produce a “sunlike” spectrum for Product MS-1 reduced light source efficiency by 26%, from 113 lumens per watt (lm/W) to 85 lm/W. Products MS-2 and MS-3 that used a violet-pumped LED to achieve “healthy” and “sunlike” enhanced optical performance, respectively, suffered the largest reduction in initial light source efficiency (49 lm/W for Product MS-2 and 68 lm/W for Products MS-3) perhaps because of the use of violet LED as the optical pump. Product MS-2 also had the poorest color fidelity because of undersaturation of blues and oversaturation of greens and yellows. Chromaticity maintenance of the products in this study was generally good, with parametric failure only occurring for one product at one AST condition (i.e., Product MS-3 at 7575). The chromaticity shift for Product MS-3 in 7575 test conditions resulted from reduced emissions of the broad green and red phosphors used to mimic sunlight in the 500–750 nanometer (nm) range. As a result of these phosphor emission losses, chromaticity shifted toward the more stable violet-pumped LED and blue phosphor. Although chromaticity maintenance was acceptable for most products tested, different chromaticity shift mechanisms were observed for temperature and humidity tests compared with temperature alone for Products MS-1, MS-2, and MS-3. For Product MS-1, a relative increase in green emissions was observed with humidity, which may indicate humidity-accelerated degradation of the optical filter at green wavelengths (optical delivery efficiency reduction) or degradation of the emitters in the red region (spectral efficiency reduction). The violet-pumped products (i.e., MS-2 and MS-3) exhibited different chromaticity shift behavior in the temperature-humidity environments, with Product MS-2 shifting generally yellow because of photo-induced oxidation of the plastic globe (i.e., a reduction of optical delivery efficiency) and Product MS-3 shifting toward violet and blue emitters because of faster loss of emission from green and red phosphors (i.e., a reduction in spectral efficiency). Because of an initial drop in power consumption, the light source efficiency of downlights (Products MS-4 and MS-5) increased at RTOL throughout the test duration. The light source efficiency initially increased during 75OL until a decay in luminous flux maintenance (LFM) dominated light source efficiency, whereas the light source efficiency decreased for the entire 7575 test duration. It was found that increasing the ambient environment of an SSL device from 25°C to 75°C decreases the LFM by 2.7 to 5.5, depending on design of the SSL device. Adding humidity to the system (75OL to 7575) was found to decrease LFM by another factor of approximately 3.0. A common location of failure was identified for the downlights (Products MS-4 and MS-5) operated in the 7575 environment. This failure abruptly occurred between 3,000 to 5,000 hrs of testing on the film capacitor of the electromagnetic interference (EMI) filter near the diode bridge for 11 of the 12 downlights. It is likely that this failure was caused by a combination of the high electrical voltage across the capacitor, the location of the capacitor near the heat sources (e.g., transformers, diode bridges, power resistors), and the high stress environment of 7575. Longer test times are needed to fully understand the LFM, luminous efficacy changes, and chromaticity shifts for some of the products. Because of the high reliability, light source efficiency, and spectral tuning capabilities of LEDs, the expectations of LAE for SSL products are greatly increased over traditional lighting products. The data gathered in this report begin to provide an understanding of the tradeoffs that current SSL products undergo when optimizing the different efficiency elements of LAE. As discussed in this report, the findings from the tests conducted show that the optimization of spectral efficiency can come at the cost of initial light source efficiency. Furthermore, the introduction of violet LEDs can promote long-term optical delivery efficiency degradation, and the introduction of optical filters or new phosphors can lead to unwanted spectral efficiency changes because the ratio of phosphor emitters changes with aging. The data presented in this report also identified a common failure location in 6-in downlights. The results regarding long-term behavior of the modified spectra devices studied provide valuable information about changes to the light source, spectral, and optical delivery efficiencies as the devices age. This information can be used to improve future SSL designs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electron Microscopy Transfer System to Protect Atmosphere‐Sensitive Materials for Scanning Electron Microscopy Characterization

Atmosphere- and/or moisture-sensitive materials can be challenging to characterize using electron microscopy techniques due to sample preparation workflows that generally require exposure to ambient conditions. Here, we describe a novel preparation method that uses aluminum foil in combination with a commercial cryo-EM transfer system to circumvent undesired exposure to the atmosphere. First, hygroscopic MgCl 2 was used as a model material, and prepared samples (both protected and unprotected) were placed in a controlled-humidity environment (> 80% relative humidity) for various exposure lengths (circa seconds to hours). Following this, the effectiveness of the sample preparation method was determined by comparing qualitative photos and quantitative X-ray diffraction patterns between the two sample subsets. The combined results of these experiments suggest that the outlined preparation method effectively protects MgCl 2 from atmospheric contamination compared to MgCl 2 samples that had no protective measures taken. Finally, the preparation method was utilized to protect a highly hygroscopic crystalline BaO thin film for characterization via scanning electron microscopy, thereby demonstrating a functional application of the outlined preparation technique and an additional use for the commercial cryo-EM transfer system beyond its intended application.

atmosphere-sensitive materials↗

Formation and degradation mechanism of methylammonium lead iodide perovskite thin film fabricated by electrospray technique

Electrospray deposition technique has been reported previously for fabricating effective and stable perovskite thin film, leading to efficient perovskite solar cells. Here, in this work, a comprehensive investigation of the formation mechanism of methylammonium lead iodide perovskite (CH 3 NH 3 PbI 3 ) film by electrospray technique is demonstrated and compared to the formation mechanism through the conventional spin coating technique. In the electrospray process, charged MAI nanoparticles are gradually introduced onto the PbI 2 film, intercalating within the PbI 2 structure to produce the perovskite film. In contrast, the spin-coating method involves supplying the MAI solution in bulk, leading to perovskite crystal formation through the dissolution of the PbI 2 layer by the MAI solution, followed by recrystallization into perovskite oriented in the [110] direction, 30° inclined to the substrate. The impact of charge and the electric field on the formation of perovskite film using the electrospray is explored. Furthermore, the intrinsic stability of perovskite films is monitored in real-time in a highly humid environment (≥80 % relative humidity (RH)) using in-situ Grazing Incidence Wide Angle X-ray Scattering (GIWAXS), and a degradation mechanism is proposed to enhance the durability of the perovskite-based devices. The study further delves into the comparison of the stability of electrosprayed and spin-coated perovskite film, and the impact of humidity level and the presence of a hole-transporting layer on the stability of the perovskite layer. Overall, this work provides a detailed understanding of the formation and humidity-induced degradation mechanism of electrosprayed perovskite films, offering insights that can extend to various applications of perovskite materials.

14 SOLAR ENERGY↗

Trace Gases, Meteorological Parameters, and GPS data for TRACER-MAP

This dataset includes trace gas, meteorological, and GPS measurements made on Mobile Air Quality Laboratory 2 (MAQL2) for the TRACER-MAP sampling campaign. Trace gas measurements include nitric oxide (NO), nitrogen dioxide (NO2), reactive nitrogen compounds (NOy), ozone (O3), sulfur dioxide (SO2), and carbon monoxide (CO). All trace gases are in units of ppbv, excluding CO which is in ppmv. The dataset also includes the photolysis rate of NO2 (jNO2), latitude and longitude, wind speed (WS), wind direction (WD), ambient relative humidity (RH), ambient pressure (press), and ambient temperature (temp). Units for trace gases are in parts per billion (ppbv), latitude and longitude are in decimal degrees (dd), jNO2 is in per second (per sec), pressure is in millibar (mbar), relative humidity is in percent, the temperature is in degrees C, wind direction is in degrees, and wind speed is in meters per second. All data is 5 minutes averaged.

54 ENVIRONMENTAL SCIENCES↗

Fretting wear of iron, nickel, and titanium under varied environmental conditions

Fretting wear experiments were conducted on high-purity iron, nickel and titanium in air under conditions of varied humidity and temperature, and in nitrogen. For iron and titanium, maximum fretting occurred at 10 and 30 percent relative humidity respectively. Nickel showed a minimum in fretting wear at about 10% relative humidity. With increasing temperature, all three metals initially showed reduced fretting wear, with increasing wear observed as temperatures increased beyond 200-300 C. For titanium, dramatically reduced fretting wear was observed at temperatures above 500 C, relatable to a change in oxidation kinetics. All three metals showed much less fretting wear in N2 with the presence of moisture in N2 having a proportionally stronger effect than in air.

Bill, R. C.↗

Fretting wear of iron, nickel, and titanium under varied environmental conditions

Fretting wear experiments were conducted on high purity iron, nickel and titanium in air under conditions of varied humidity and temperature, and in nitrogen. For iron and titanium, maximum fretting occurred at 10 and 30 percent relative humidity respectively. Nickel showed a minimum in fretting wear at about 10 percent relative humidity. With increasing temperature, all three metals initially showed reduced fretting wear, with increasing wear observed as temperatures increased beyond 200-300 C. For titanium, dramatically reduced fretting wear was observed at temperatures above 500 C, relatable to a change in oxidation kinetics. All three metals showed much less fretting wear in N2 with the presence of moisture in N2 having a proportionally stronger effect than in air.

Bill, R. C.↗

A simple method to measure the isosteric energy of adsorption

The effect of temperature on water vapour desorption isotherms can be described simply using the Clausius-Clapeyron equation and the isosteric energy of adsorption, the latter conventionally estimated using two (or more) isotherms obtained at different temperatures. This approach has some disadvantages, however, and this article puts forward a simple alternative methodology for characterising this isosteric energy experimentally. Our method is based on monitoring the relative humidity of a cementitious material heated under sealed conditions. The evolution of the relative humidity as a function of temperature makes it possible to directly evaluate the isosteric energy. In practice, the tests are performed using a cell of the type that is used for self-desiccation studies.

36 MATERIALS SCIENCE↗

CO 2 Sorption in Moisture Swing Anion Exchange Resins for Direct Air Capture: Experimental Isotherm Determination and Modeling

Moisture swing (MS) sorption is a promising direct air capture (DAC) technology to achieve negative CO 2 emissions and counter global warming. Here, in this study, MS CO 2 sorption in a model MS sorbent, IRA900, was investigated. IRA900 is a macroporous commercial strong-base anion exchange resin (AER) with quaternary ammonium functional groups. A rigorous CO 2 desorption process was developed to desorb all CO 2 from the sample and obtain CO 2 sorption isotherms as a function of relative humidity, CO 2 partial pressure, and temperature. CO 2 sorption increased with decreasing relative humidity, decreasing temperature, and increasing CO 2 partial pressure. Remarkably, the total CO 2 uptake from the sorption isotherms matched the ion exchange capacity (IEC) of the material, suggesting a stoichiometry of one CO 2 molecule reacting per active site. An isotherm model for CO 2 sorption starting with empty sorption sites (i.e., with the AER in the OH – form) described the experimental data well, supporting the hypothesis that the bicarbonate-loaded AER fully unloaded to the OH – state following rigorous CO 2 desorption. CO 2 sorption kinetics were studied, and carbon diffusion coefficients were estimated as a function of %RH and CO 2 partial pressure. Overall, this study provides a roadmap for the systematic evaluation of MS CO 2 DAC materials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Comparative Study of Cloud Properties Between Northern and Southern High Latitudes Based on ARM Observations and EAMv2 Simulations

Earth's high-latitude regions show a considerable amount of cloud coverage, which significantly affects global radiation budgets. Here, in this study, we examine ground- and ship-based remote sensing observations from two Atmospheric Radiation Measurement (ARM) field campaigns conducted in the high-latitude regions of Northern and Southern Hemispheres (NH and SH). A comparison of macrophysical properties for low, mid-level, high, and deep clouds shows that the cloud top heights and thickness values are higher in the Arctic for each cloud type compared with the Southern Ocean and Antarctic regions, possibly due to higher sea surface temperatures in the north Atlantic. The Arctic also shows lower ice phase occurrence frequencies compared with the SH high latitudes for low clouds. For high, mid-level and deep clouds, the cloud phase distributions as a function of temperature show small geographical variabilities. The observations are then compared with the Department of Energy (DOE) Energy Exascale Earth System Model (E3SM) to evaluate the representations of these cloud properties. Here, the results show that the model captures cloud base and top heights well and reproduces the differences in cloud macrophysical properties between the two hemispheres. But the model underestimates ice phase frequencies for all cloud types. Such model cloud phase bias is strongly correlated with positive relative humidity biases and negative aerosol number concentration biases, indicating an important role of relative humidity and aerosols in modulating cloud phase partitioning in the model.

54 ENVIRONMENTAL SCIENCES↗

Fracture toughness and crack growth of Zerodur

The fracture toughness and crack growth parameters of Zerodur, a low expansion glass ceramic material, were determined. The fracture toughness was determined using indentation techniques and was found to be 0.9 MPa x m(sup 1/2). The crack growth parameters were determined using indented biaxial specimens subjected to static and dynamic loading in an aqueous environment. The crack growth parameters n and 1n(B) were found to be 30.7 and -6.837, respectively. The crack growth parameters were also determined using indented biaxial specimens subjected to dynamic loading in an ambient 50 percent relative humidity environment. The crack growth parameters n and 1n(B) at 50 percent relative humidity were found to be 59.3 and -17.51, respectively.

Viens, Michael J.↗

Elevation distributed micro-climatology data in a coastal glaciated watershed

Air temperature, ground temperature and relative humidity data were collected in a longitudinal transect of the Nooksack watershed at varying elevations from 500 to 1800 m above sea level. Data were collected by anchoring sensors from trees above winter snow levels and shaded from direct solar radiation. Paired sensors were also buried 3 cm under ground near each air temperature sensor to determine snow absence or presence. Select sites included relative humidity sensors to indicate whether precipitation was occurring. Data were collected every 3-4 h from December 2015 to Sept 2018 (with ongoing collection). Code for analysis of daily mean, minimum, maximum, and temperature change with elevation (lapse rates) are available on Github (https://doi.org/10.5281/zenodo.3239539). The sensor download and intermediate data products are available on HydroShare at (http://www.hydroshare.org/resource/222e832d3df24dea9bae9bbeb6f4219d) with publicly accessible visualization available from the Nooksack Observatory at data.cuahsi.org. Hydrologic models are generally structured with a single annual average lapse rate parameter which assumes a linear temperature gradient with elevation. The daily data (2016-2018) is used as part of ongoing studies on the non-linear dynamics and temporal variability of temperature with elevation to improve assessments of watershed function and salmon habitat.

54 ENVIRONMENTAL SCIENCES↗