Search NASA⌕ Search

SEARCH · Search NASA

Results for “risk communication”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Stripline Block Sensor System

The Long Baseline Neutrino Facility requires a secondary sensor system to aid in the installation and replacement of the stripline blocks. These blocks are responsible for delivering large amounts of current to the horn and must be installed with high precision to avoid possible physical damage. There are many constraints due to the modules' surroundings, such as small clearances and a highly radioactive environment. Existing systems have already been implemented within the process; however, these systems offer limited information, leaving much risk during operations. This calls for a sufficiently accurate sensor system, which has a small space requirement and provides valuable information throughout the replacement period. A variety of methods and technologies were explored to provide an applicable approach to the issue. The proposed solution consisted of the use of retroreflective and target, however, it cannot provide positional feedback throughout the entire process. A proposed alternative utilizes a three-dimensional indoor positioning system to provide the operator with real-time positioning and rotational information. Sensors placed on the module and stripline would communicate with fixed receivers surrounding the target hall to provide precise positional feedback. However, this solution may still contain line-of-sight issues as well as installation complications due to the radioactive environment. Future work would consist of finding vendors capable of providing technology that fits our constraints, proof of concept tests for both solutions, implementation planning, and trials within the target hall itself. Due to its ability to provide continuous positional and rotational feedback, the indoor positioning system is the most suitable solution for accurately installing the stripline block.

Espinoza, David [Unlisted, US]↗

Regression Analysis with the Directed Infusion of Data

Integrating artificial intelligence and machine learning tools into industry necessitates large-scale collaborative efforts that ensure the robust and accurate execution of downstream analytics such as time series prediction, uncertainty quantification, grid optimization, and condition monitoring. However, concerns related to data privacy pervade the nuclear industry due to the proprietary nature of its data and the possibility of data leakage. Legacy techniques such as encryption often require the explicit transmission of data to trustworthy parties, thereby inviting data leakage concerns. The ideal collaboration scenario avoids the explicit dissemination of data/code while maintaining experimental fidelity, which is currently accomplished using various techniques such as trusted execution environments, homomorphic encryption, differential privacy, and multimatrix masking. These techniques, however, often necessitate a trade-off between trust, efficiency, and utility. This article extends a previously proposed technique called the directed infusion of data (DIOD) that ensures data privacy, allows for scalable obfuscation, and combats the risk of data leakage without compromising utility. The experiments discussed in this article examine a regression-type scenario using DIOD with the goal of preserving the inferential link between two variables. Using the point-kinetics equations, regression experiments compare the performance of a model trained using the original data to that of a model trained using the obfuscated data, which produced identical results. Our claim is further strengthened by an information theoretic proof and experiment, which showed that the inferential content between variables remains the same after obfuscation, thereby avoiding the required communication of the proprietary data.

47 - OTHER INSTRUMENTATION↗

FORCE-DISPATCHES Integration - Initial Demonstration

Integrated energy systems (IES) combine, in mutually beneficial ways, power from variable renewable energy sources and nuclear power plants (NPP) to improve economic viability under uncertain market and weather conditions. The open-source Framework for Optimization of Resources and Economics (FORCE) tool suite, developed at Idaho National Laboratory (INL), has enabled comprehensive modeling and simulation of IES. The capabilities within FORCE include grid portfolio optimization through the Holistic Energy Resource Optimization Network (HERON) and the transient process model analysis library HYBRID, among others. Continuous efforts and investments from the IES programs have been made to expand and improve the versatility of the FORCE toolset in fiscal year 2022. Code-coupling and cross-tool communication have been important methods for improving this versatility. This report focuses on an additional workflow in the HERON tool for capacity and dispatch stochastic optimization through integration with the external tool Design Integration and Synthesis Platform to Advance Tightly Coupled Hybrid Energy Systems (DISPATCHES). DISPATCHES was primarily developed by the National Energy Technology Laboratory, in collaboration with other national laboratories, which included INL, universities, and industry partners. It is coupled to a library of algebraic models for specific plant components, and to a framework for stochastic optimization different from that provided in the current Risk Analysis Virtual Environment (RAVEN)-running-RAVEN algorithm in HERON. HERON currently conducts stochastic optimization via an outer-inner loop: it optimizes over variable capacity on the outer loop, and at each step within the capacity parameter space, conducts an inner optimization over scenarios (of market signals, demand, and/or weather patterns) and hourly dispatch throughout a user-specified number of years. On the other hand, DISPATCHES conducts stochastic optimization via an “all-at-once” strategy in which capacity variables are optimized at the same level as dispatch variables, as all scenarios are considered at once. The latter method works especially well for projects of limited size and project length, as the necessary computational power and memory increases with the number of variables and scenarios. The new capability to use the DISPATCHES workflow in HERON enhances standalone simulations by leveraging FORCE tools—namely, the economic metrics from the Tool for Economic Analysis (TEAL) and reduced-order model (ROM) sampling from RAVEN. The initial demonstration of the DISPATCHES workflow simulates an existing nuclear-case flowsheet within the DISPATCHES repository—this models a NPP with a secondary revenue stream for hydrogen production. Electrical output from the plant is converted to hydrogen via a proton-exchange membrane (PEM) electrolyzer, hydrogen tanks are used for storage, and an additional turbine is added for hydrogen combustion. Continued work regarding this FORCE-DISPATCHES integration will include automatic generation of DISPATCHES models from HERON inputs, offering analysts the option of using either the RAVEN-runsRAVEN or DISPATCHES workflow to solve technoeconomic optimization problems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantifying the effect of multiple load flexibility strategies on commercial building electricity demand and services via surrogate modeling

The expansion of commercial building demand response as a demand-side management resource for the electric grid necessitates new decision support resources for customers seeking to assess the benefit–risk tradeoffs of possible strategies for energy flexible building operations. To address this need, we, in this study, develop surrogate models that predict the impacts of several load flexibility strategies on commercial building electricity demand and indoor temperature, focusing on offices and retail buildings at multiple scales. The surrogate models are fit to a synthetic database generated via whole building simulations, which establish the relationships between the key operational features of a given strategy and potential changes in building demand and temperature across a variety of contexts. The surrogate models are translated to a Bayesian framework to allow straightforward communication of uncertainty and parameter updating given new evidence. We find strong predictive performance across the suite of models, underscoring the usefulness of the approach in guiding decisions about implementing load flexibility strategies under a particular set of operational and environmental conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cybersecurity Governance

Cybersecurity governance helps an organization detect, prevent, and respond to cyber incidents by establishing cybersecurity policies and procedures for use across the enterprise. As modern energy systems become increasingly reliant on smaller and decentralized generation sources-equipped with complex, data-driven communications-governance will be of growing importance for the continued protection of the electric grid. This presentation sheds light on the important aspects of cybersecurity governance, best practices to ensure a culture of cybersecurity, and approaches to frequent monitoring and assessment of an organization's cybersecurity posture.

business requirements↗

Real-time Simulation Framework for Hardware-in-the-Loop Testing of Multi-port Autonomous Reconfigurable Solar Power Plant (MARS)

Multiport autonomous reconfigurable solar power plant (MARS) has been proposed for integrated development of photovoltaic (PV) and energy storage system (ESS) that can connect to high-voltage direct current (HVdc) and alternating current (ac) transmission grid. To de-risk the development of this complex integrated system that consists of hundreds to thousands of power electronics modules, a controller hardware-in-the-loop (cHIL) test setup will be extremely beneficial. The cHIL testing can be used for evaluation of modules as well as the hierarchical control system in MARS. With the unique configuration of power electronics modules in MARS, it becomes necessary to develop custom-designed real-time simulation models in the cHIL setup in absence of off-the-shelf models. In this paper, high-fidelity dynamic model of MARS, control algorithms at the lower level, and required communication algorithms are developed and optimized for real-time performance in the cHIL setup. Real-time experimental results from the cHIL are provided.

Dong, Zerui↗

Digital Assurance for Grid Reliability in the Era of Large Load Growth

The rapid expansion of large electric loads is reshaping the operational and regulatory landscape of the U.S. electric grid. These facilities are reaching new scales of expansion, now exceeding a gigawatt per site, and their highly sensitive, digitally driven behaviors introduce new reliability risks. Recent grid events, including large load losses following routine transmission disturbances, highlight the consequences of limited ride-through capability, inconsistent protection settings, inadequate modeling, and lack of behind-the-meter visibility. Parallels to earlier integration challenges of new grid technologies suggest that the grid’s existing processes, standards, and interconnection frameworks are no longer adequate for emerging large loads. This brief synthesizes lessons from the evolution of inverter-based resource regulation and applies them to large-load integration. It identifies critical gaps in modeling accuracy, interconnection processes, performance standards, and compliance mechanisms. Technical recommendations emphasize advanced monitoring, improved modeling, coordinated communication protocols, modernized substations, and structured behind-the-meter control schemes. Collectively, these measures provide a roadmap to maintain bulk power system reliability while enabling the continued growth of large, electrified digital infrastructure.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Biphasic response of human iPSC-derived neural network activity following exposure to a sarin-surrogate nerve agent

Organophosphorus nerve agents (OPNA) are hazardous environmental exposures to the civilian population and have been historically weaponized as chemical warfare agents (CWA). OPNA exposure can lead to several neurological, sensory, and motor symptoms that can manifest into chronic neurological illnesses later in life. There is still a large need for technological advancement to better understand changes in brain function following OPNA exposure. The human-relevant in vitro multi-electrode array (MEA) system, which combines the MEA technology with human stem cell technology, has the potential to monitor the acute, sub-chronic, and chronic consequences of OPNA exposure on brain activity. However, the application of this system to assess OPNA hazards and risks to human brain function remains to be investigated. In a concentration-response study, we have employed a human-relevant MEA system to monitor and detect changes in the electrical activity of engineered neural networks to increasing concentrations of the sarin surrogate 4-nitrophenyl isopropyl methylphosphonate (NIMP). We report a biphasic response in the spiking (but not bursting) activity of neurons exposed to low (i.e., 0.4 and 4 μM) versus high concentrations (i.e., 40 and 100 μM) of NIMP, which was monitored during the exposure period and up to 6 days post-exposure. Regardless of the NIMP concentration, at a network level, communication or coordination of neuronal activity decreased as early as 60 min and persisted at 24 h of NIMP exposure. Once NIMP was removed, coordinated activity was no different than control (0 μM of NIMP). Interestingly, only in the high concentration of NIMP did coordination of activity at a network level begin to decrease again at 2 days post-exposure and persisted on day 6 post-exposure. Notably, cell viability was not affected during or after NIMP exposure. Also, while the catalytic activity of AChE decreased during NIMP exposure, its activity recovered once NIMP was removed. Gene expression analysis suggests that human iPSC-derived neurons and primary human astrocytes resulted in altered genes related to the cell’s interaction with the extracellular environment, its intracellular calcium signaling pathways, and inflammation, which could have contributed to how neurons communicated at a network level.

59 BASIC BIOLOGICAL SCIENCES↗

Dragonstone Strategy – State of Cybersecurity in the Oil & Natural Gas Sector

The oil & natural gas (ONG) system touches every corner of the nation and increased communications & control capabilities have not only allowed for greater efficiency of system operation, but have also created a massive target for adversaries to launch cyber-attacks. Like any other heavy industrial process, the ONG system relies on a complex system of information technology (IT) and operational technology (OT) devices. The current state of cyber-preparedness across the ONG industry varies from organization to organization. Among the most common challenges that ONG companies face are remote locations, longlived field assets, and lacking capabilities to find and track malware on their systems. ONG companies tend to be concerned with lack of cyber-awareness from employees, risk stemming from remote access for operations & maintenance, and software vulnerabilities within third-party equipment. Various industry and government organizations are performing research and development activities to address some of these challenges, but in many cases industry stakeholders are not aware of solutions that already exist. It is clear that a need exists for a coherent, comprehensive, multi-layered strategy for assuring the security and resilience of the nation's pipeline infrastructure against cyber threats. For a variety of reasons, the general consensus from stakeholders interviewed by LLNL is that the state of cyber-security within the electric grid is currently outpacing its ONG cousin. Existing strategies for the resilience and cyber-security of the electric grid can and should be leveraged to provide immediate benefits to the ONG system. In LLNL’s view, there are two key factors currently limiting the development of necessary cyber-practices within the ONG industry: The sheer number of differing regulatory bodies and trade groups offering both standards and best-practice recommendations for ONG cyber-security makes it difficult to create a comprehensive, directed, and coherent strategy that is applicable to all players within the ONG industry. The ONG industry is unaware of potentially useful technologies that have been developed for ensuring cyber-security of other infrastructure systems, such as the electric grid. Leveraging these technologies—and the science and engineering behind them—can provide some low-hanging fruit that can greatly improve cyber-security in the ONG industry without significant investments in terms of time and money. In the months following this report, LLNL will continue to perform outreach to key oil & gas industry stakeholders in a continual effort to identify the most pressing cyber-resilience issues in the industry. This outreach will be supplemented with LLNL’s threat intelligence capabilities to begin painting a clearer picture of the overall threat landscape faced by this sector. This assessment will be threat-informed and while the strategy itself will not be classified we will leverage intelligence analysis and adversary capabilities to identify gaps in current cybersecurity practices for oil & gas pipeline systems. Recommended efforts will be compiled into a cyber-resilience roadmap for the oil & gas pipeline sector, in which LLNL will highlight priority activities to immediately improve the state of cyber-resilience in the industry.

02 PETROLEUM↗

A Framework to Design Consumer-Centric Operational Strategies for Resilience Enhancement

Extreme temperature-related events like heat waves or cold snaps can significantly stress the power distribution grid as electricity demand spikes leading to brownouts or blackouts if not managed properly. In addition, such extreme events can exacerbate inequity, with vulnerable populations (for example, houses with poor insulation, located in non-critical zones, and lack of local resources) at greater risk. There is a growing deployment of distribution systems automation technologies such as advanced metering infrastructure, sensors, and automated control systems to enhance the visibility of the entire distribution grid while meeting resilience objectives. Here, this paper proposes a framework for investigating how automation can improve the distribution system's resilience and ensure customers' health and safety during such extremes. The proposed framework's efficacy will be demonstrated for the Electricity Reliability Council of Texas (ERCOT) during winter storm Uri with varying levels of distribution automation technologies such as feeder isolation using smart switches, remote outage signals using advanced meters, and comfort-aware outage using advanced analytics and communication. Simulation results show that an outage strategy involving advanced grid technology and communication can reduce the occupant exposure to severe cold by 93% and, simultaneously, reduce expected energy not served by 73.2% when compared against feeder isolation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Critical Infrastructure Decision-Making under Long-Term Climate Hazard Uncertainty: The Need for an Integrated, Multidisciplinary Approach

U.S. critical infrastructure assets are often designed to operate for decades, and yet long-term planning practices have historically ignored climate change. With the current pace of changing operational conditions and severe weather hazards, research is needed to improve our ability to translate complex, uncertain risk assessment data into actionable inputs to improve decision-making for infrastructure planning. Decisions made today need to explicitly account for climate change – the chronic stressors, the evolution of severe weather events, and the wide-ranging uncertainties. If done well, decision making with climate in mind will result in increased resilience and decreased impacts to our lives, economies, and national security. We present a three-tier approach to create the research products needed in this space: bringing together climate projection data, severe weather event modeling, asset-level impacts, and contextspecific decision constraints and requirements. At each step, it is crucial to capture uncertainties and to communicate those uncertainties to decision-makers. While many components of the necessary research are mature (i.e., climate projection data), there has been little effort to develop proven tools for long-term planning in this space. The combination of chronic and acute stressors, spatial and temporal uncertainties, and interdependencies among infrastructure sectors coalesce into a complex decision space. By applying known methods from decision science and data analysis, we can work to demonstrate the value of an interdisciplinary approach to climate-hazard decision making for longterm infrastructure planning.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cybersecurity Considerations for Hydrogen Infrastructure in Airport Environments

This report explores key cybersecurity concerns and best practices within environments that serve as reference points for the development of hydrogen fueling infrastructure for aviation. This cybersecurity analysis leverages prior NREL studies: 1) hydrogen fueling station component validation to identify vulnerabilities and failure events documented in physical equipment, and 2) electric aircraft charging infrastructure analysis to explore primary cybersecurity vulnerabilities. It reviews the criticality of digitized technologies in sustaining hydrogen fuel production, storage, and fueling systems, noting cybersecurity concerns that are universal to power systems and industrial control systems in general. In considering cybersecurity vulnerabilities within a future landscape of hydrogen energy for aviation applications, a reference architecture was intended to reveal the points of connection between assets and the potential sensors that are vulnerable to manipulation in the event of compromised access or communication within a SCADA system. A generalized reference architecture can help stakeholders, engineers, or strategists understand connections, criticalities, and standard practices when it comes to designing and planning for new systems. There are several gaps to account for in assessing the future of hydrogen production, storage, and fueling for aviation. Engaging stakeholders, including aircraft manufacturers, electric utilities, site property owners, and local communities, will inform decision-making around site structure, operations, and resources for future hydrogen fueling infrastructure to understand operational needs and cybersecurity awareness. Cybersecurity mitigation strategy must consider physical attack vectors that emerge with the integration of hydrogen systems into existing airport security requirements. The cybersecurity risk assessment contained in this report is an entry point into potential future granular-level analyses to be conducted as part of hazard and risk assessments for safe aviation hydrogen infrastructure, determining how the scale of hydrogen fuel infrastructure for aviation impacts the volume of cyber attack vectors, and what, if any, are the vulnerabilities associated with different types of on-board hydrogen systems. In this nascent development phase, assessing how best to integrate cybersecurity practices into an evolving U.S. aviation landscape provides critical insights into building increased awareness and stakeholder engagement to support a cyber-resilient infrastructure.

08 HYDROGEN↗

SDN-Based Smart Cyber Switching (SCS) for Cyber Restoration of a Digital Substation

In recent years, critical infrastructure and power grids have increasingly been targets of cyber-attacks, causing widespread and extended blackouts. Digital substations are particularly vulnerable to such cyber incursions, jeopardizing grid stability. This paper addresses these risks by proposing a cybersecurity framework that leverages software-defined networking (SDN) to bolster the resilience of substations based on the IEC- 61850 standard. The research introduces a strategy involving smart cyber switching (SCS) for mitigation and concurrent intelligent electronic device (CIED) for restoration, ensuring ongoing operational integrity and cybersecurity within a substation. The SCS framework improves the physical network’s behavior (i.e., leveraging commercial SDN capabilities) by incorporating an adaptive port controller (APC) module for dynamic port management and an intrusion detection system (IDS) to detect and counteract malicious IEC-61850-based sampled value (SV) and generic object-oriented system event (GOOSE) messages within the substation’s communication network. The framework’s effectiveness is validated through comprehensive simulations and a hardware-in-the-loop (HIL) testbed, demonstrating its ability to sustain substation operations during cyber-attacks and significantly improve the overall resilience of the power grid.

Liu, Chen-Ching (ORCID:0000000289417958)↗

Molten Salt Loop Operational Experience and Test Campaigns in FY24

The Facility to Alleviate Salt Technology Risks (FASTR) at the US Department of Energy (DOE) Oak Ridge National Laboratory (ORNL) was developed to demonstrate technology for high-temperature chloride salt systems (Figure 1). FASTR is primarily constructed using alloy C-276 and is designed to operate at temperatures of up to 725°C. The facility is loaded with 250 kg of NaCl-KCl-MgCl 2 salt. This salt provides a relevant test environment for de-risking technology while avoiding the costs and hazards associated with beryllium-based or uranium-bearing salts. The facility’s major components include a centrifugal pump for salt circulation, an air-based heat exchanger to reject heat, a suite of instrumentation, and trace heating to prevent salt freezing. The salt was purified in 2020 and 2022, and the pumped loop first operated in December 2022. FASTR is a unique US capability for high-temperature molten halide salt testing. FASTR’s scale, co located purification system, and relatively large power (465 kW) differentiates it from other testing systems. Furthermore, access to the DOE-supported facility and efficient communication of results— which are generally disseminated publicly—distinguish FASTR as being broadly significant throughout the molten salt reactor community. FASTR is similar to ORNL’s Liquid Salt Test Loop (LSTL), although FASTR contains chloride-based salt instead of the fluoride-based salt (LiF-NaF-KF) found in LSTL. Furthermore, FASTR is approximately 2× larger than LSTL in terms of pipe size and length, power, salt volume, flow rate, and number of thermocouples. The LSTL first operated in 2016. At the end of FY23, there was a suspected gas leak in the LSTL that halted operation. At the start of FY24, a leak in the LSTL pump’s tank gas space was confirmed. Because the gas-space leak prevented operation of LSTL, FY24 efforts were focused on operation of FASTR. This report summarizes the progress made during FY24 in support of the DOE Office of Nuclear Energy (DOE-NE) work package, AT-24OR070202 Salt Loop and Capability for Testing Sensors and Off Gas Components.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Aggregate attack surface management for network discovery of operational technology

Interconnectivity has become a substratum of technology as the benefits of data-driven functionality are being realized in nearly all industries. Increased connectivity of Operational Technology (OT) exacerbates cyber risks because Industrial Control Systems (ICS) are becoming exposed to the Internet. These exposures are often done inadvertently through misconfigurations as additional network devices come online. Attack surface management (ASM) platforms can be used to identify vulnerabilities by performing external network discovery over the Internet using web spiders. These web spiders enable big data analytics of Internet of Things (IoT) devices as identifiable information of Internet-exposed equipment are archived in searchable databases that are made publicly available. There are a multitude of ASM service providers on the market. Here, this study was conducted to evaluate several commonly known tools to determine the aggregate attack surface of control systems. Queries were crafted by targeting commonly known manufacturers and communication protocols found in OT networks. Identified devices were that categorized based on technology types. Each query was replicated between several tools to target identical ICS equipment. Findings in this paper suggested a significant variance in the exposures discovered by each tool, but unique contributions were identified for each tool when a merged attack surface was derived. Therefore, all tools should be used in aggregate.

97 MATHEMATICS AND COMPUTING↗

MSD CoP Webinar: Advancing MSD Research with Artificial Intelligence

Context: This webinar was hosted by the MultiSector Dynamics Community of Practice (MSD CoP; https://multisectordynamics.org). Abstract: Recent advances in Artificial Intelligence (AI) are quickly changing the landscape of tools available to conceptualize, execute, and disseminate research. We posit that research efforts in Multi-Sector Dynamics can benefit from these advances; the new AI in MSD Working Group thus aims to identify and quantify opportunities and risks associated with their implementation. In this webinar, we will first introduce the new AI Working Group, which was initially conceived during the first MSD workshop in October 2023. Next, our panelists will explore how generative AI, explainable AI, and machine learning can help us improve modeling efforts in multiple domains, including climate science, hydrology, and energy systems. Finally, we will discuss the aims of the working group, gather inputs from the community, and suggest directions for the next steps. Presenters : Andrea Castelletti (Politecnico di Milano; Invited Speaker), Chaopeng Shen (Pennsylvania State University; Invited Speaker), Nicole Jackson (Sandia National Laboratory; Invited Speaker), Stefano Galelli (Cornell University; Co-Chair), David Gold (Utrecht University; Co-Chair), Jillian Sturtevant (Baylor University; Communications Officer) Moderator: Pat M. Reed (MSD CoP Facilitation Team) This webinar was held on: June 14th, 2024 from 12-1:30 PM EST

Artificial Intelligence↗

Recommendations for Distributed Energy Resource Access Control

Cybersecurity for internet - connected Distributed Energy Resources (DER) is essential for the safe and reliable operation of the US power system. Many facets of DER cybersecurity are currently being investigated within different standards development organizations, research communities, and industry committees to address this critical need. This report covers DER access control guidance compiled by the Access Controls Subgroup of the SunSpec/Sandia DER Cybersecurity Workgroup. The goal of the group was to create a consensus - based technical framework to minimize the risk of unauthorized access to DER systems. The subgroup set out to define a strict control environment where users are authorized to access DER monitoring and control features through three steps: (a) user is identified using a proof-of-identity, (b) the user is authenticated by a managed database, (c) and the user is authorized for a specific level of access. DER access control also provides accountability and nonrepudiation within the power system control environment that can be used for forensic analysis and attribution in the event of a cyber-attack. This paper covers foundational requirements for a DER access control environment as well as offering a collection of possible policy, model, and mechanism implementation approaches for IEEE 1547-mandated communication protocols.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Facilitating Data Collection of Maintenance Events to Populate the Hydrogen Component Reliability Database (HyCReD)

The Hydrogen Component Reliability Database (HyCReD) is a collaborative project between the National Renewable Energy Laboratory, the University of Maryland, and hydrogen stakeholders to improve safety and reliability for hydrogen facilities by implementing component reliability data taxonomies that support hydrogen infrastructure failure rate analysis. The project aims to quantify failure rates of hydrogen components through high-quality data collection and analysis on root causes and maintenance needed. HyCReD provides a common database for cataloging hydrogen component failures which exists for reliability research in many other mature industries [2]. The database fills a gap for the hydrogen community by providing a scientifically rigorous approach to quantitative risk assessment (QRA), prognostic health management (PHM), and reliability-centered maintenance (RCM) analysis. High level results will be aggregated and anonymized to protect company sensitive information; detailed results will be used to help address issues of hydrogen components. These advanced analytics will support accelerated deployment of hydrogen infrastructure by enabling better: design and safety of projects (safety codes and standards development), infrastructure reliability and cost (component failure rates, maintenance protocols), and component R&D needs (robust supply chain). A key to a successful HyCReD implementation is facilitating the ease of reporting and data quality in the database that can be used for analysis. Maintenance data was a previously identified gap in initial efforts to populate and validate the database taxonomies [3]. Collection of maintenance data will be instrumental in identifying failure modes and rates, identifying incipient component failures or reduced performance, cataloging best practices for maintenance routines and methods for prognostic health management, and quantifying the risk and effect of different failure modes. Several key priorities are identified for streamlined data collection to achieve quality and detailed failure data: Applicability, Ease of Use, Accessibility, and Information Security. The HyCReD team has now begun deployment of the database to several companies and groups that have signed non-disclosure agreements to facilitate the data collection of failures in industry hydrogen refueling station infrastructure. This paper will provide an update into the process of HyCReD deployment including the development of a coding guide for facility personnel to reference and ensure data quality and consistency from one station to another as well as implementation of contextually dependent data fields of system taxonomy and formatted entries to provide ease of use. The goal is to communicate the lessons learned from the roll-out to technicians and engineers in the field, and the addition of need for high level of security to protect all stakeholders.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗