Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Using Technology to Better Characterize the Apollo Sample Suite: A Retroactive PET Analysis and Potential Model for Future Sample Return Missions

From 1969-1972 the Apollo missions collected 382 kg of lunar samples from six distinct locations on the Moon. Studies of the Apollo sample suite have shaped our understanding of the formation and early evolution of the Earth-Moon system, and have had important implications for studies of the other terrestrial planets (e.g., through the calibration of the crater counting record) and even the outer planets (e.g., the Nice model of the dynamical evolution of the Solar System). Despite nearly 50 years of detailed research on Apollo samples, scientists are still developing new theories about the origin and evolution of the Moon. Three areas of active research are: (1) the abundance of water (and other volatiles) in the lunar mantle, (2) the timing of the formation of the Moon and the duration of lunar magma ocean crystallization, (3) the formation of evolved lunar lithologies (e.g., granites) and implications for tertiary crustal processes on the Moon. In order to fully understand these (and many other) theories about the Moon, scientists need access to "new" lunar samples, particularly new plutonic samples. Over 100 lunar meteorites have been identified over the past 30 years, and the study of these samples has greatly aided in our understanding of the Moon. However, terrestrial alteration and the lack of geologic context limit what can be learned from the lunar meteorites. Although no "new" large plutonic samples (i.e., hand-samples) remain to be discovered in the Apollo sample collection, there are many large polymict breccias in the Apollo collection containing relatively large (approximately 1 cm or larger) previously identified plutonic clasts, as well as a large number of unclassified lithic clasts. In addition, new, previously unidentified plutonic clasts are potentially discoverable within these breccias. The question becomes how to non-destructively locate and identify new lithic clasts of interest while minimizing the contamination and physical degradation of the samples.

Zeigler, R. A.↗

Understanding Martian Alteration Processes by Comparing In-Situ Chemical Measurements from Multiple Landing Sites

Characterizing the history of aqueous activity at the martian surface has been an objective of the Mars Exploration Rovers (MER) and the Mars Science Laboratory (MSL). Although the geologic context of the three landing sites are different, comparisons across the datasets can provide greater insight than using data from one mission alone. The Alpha Particle X-ray Spectrometer (APXS) is common to all three rovers (Spirit at Gusev crater, Opportunity at Meridiani Planum, and Curiosity at Gale crater) and provides a consistent basis for these comparisons. Soil and Dust: Fine grained basaltic soils and dust are remarkably uniform in chemical composition across multiple landing sites. These similarities in the concentrations of major, minor, and a few trace elements (Fig. 1) are indicative of planet-wide consistency in the composition of source materials for the soils. S and Cl vary by a factor of two in the soil and dust, but there is no clear association with any bulk cation (e.g., no correlation between S and total Ca, Mg, or Fe in soils). These volatile elements, however, are clearly associated with the nanophase-ferric iron component in the soil established by Mössbauer spectroscopy [1,2]. S and Cl likely originated as acidic species from volcanic out-gassing and subsequently coalesced on dust and sand grain surfaces, possibly with an affinity towards Fe3+ sites. Importantly, given the mobility of S and Cl in aqueous exposures, soil samples maintaining the typical molar S/Cl ratio of ~3.7:1 indicate minimal interactions with liquid water after the addition of S and Cl. In contrast to this well-established baseline, soil samples have been discovered at all three landing sites with atypical S/Cl ratios (e.g., subsurface soils), indicative of a more complex aqueous history.

Yen, A. S.↗

Microbiological Methodology in Astrobiology

Searching for life in astromaterials to be delivered from the future missions to extraterrestrial bodies is undoubtedly related to studies of the properties and signatures of living microbial cells and microfossils on Earth. As model terrestrial analogs of Martian polar subsurface layers are often regarded the Antarctic glacier and Earth permafrost habitats where alive microbial cells preserved viability for millennia years due to entering the anabiotic state. For the future findings of viable microorganisms in samples from extraterrestrial objects, it is important to use a combined methodology that includes classical microbiological methods, plating onto nutrient media, direct epifluorescence and electron microscopy examinations, detection of the elemental composition of cells, radiolabeling techniques, PCR and FISH methods. Of great importance is to ensure authenticity of microorganisms (if any in studied samples) and to standardize the protocols used to minimize a risk of external contamination. Although the convincing evidence of extraterrestrial microbial life will may come from the discovery of living cells in astromaterials, biomorphs and microfossils must also be regarded as a target in search of life evidence bearing in mind a scenario that alive microorganisms had not be preserved and underwent mineralization. Under the laboratory conditions, processes that accompanied fossilization of cyanobacteria were reconstructed, and artificially produced cyanobacterial stromatolites resembles by their morphological properties those found in natural Earth habitats. Regarding the vital importance of distinguishing between biogenic and abiogenic signatures and between living and fossil microorganisms in analyzed samples, it is worthwhile to use some previously developed approaches based on electron microscopy examinations and analysis of elemental composition of biomorphs in situ and comparison with the analogous data obtained for laboratory microbial cultures and fossilized microorganisms. This communication will be focused on the analysis of our experience in working with ancient microorganisms and fossils and discussion of some issues that are crucial for development of the program for future finding of extraterrestrial life and its evidence.

Abyzov, S. S.↗

Cleaning Genesis Sample Return Canister for Flight: Lessons for Planetary Sample Return

Sample return missions require chemical contamination to be minimized and potential sources of contamination to be documented and preserved for future use. Genesis focused on and successfully accomplished the following: - Early involvement provided input to mission design: a) cleanable materials and cleanable design; b) mission operation parameters to minimize contamination during flight. - Established contamination control authority at a high level and developed knowledge and respect for contamination control across all institutions at the working level. - Provided state-of-the-art spacecraft assembly cleanroom facilities for science canister assembly and function testing. Both particulate and airborne molecular contamination was minimized. - Using ultrapure water, cleaned spacecraft components to a very high level. Stainless steel components were cleaned to carbon monolayer levels (10 (sup 15) carbon atoms per square centimeter). - Established long-term curation facility Lessons learned and areas for improvement, include: - Bare aluminum is not a cleanable surface and should not be used for components requiring extreme levels of cleanliness. The problem is formation of oxides during rigorous cleaning. - Representative coupons of relevant spacecraft components (cut from the same block at the same time with identical surface finish and cleaning history) should be acquired, documented and preserved. Genesis experience suggests that creation of these coupons would be facilitated by specification on the engineering component drawings. - Component handling history is critical for interpretation of analytical results on returned samples. This set of relevant documents is not the same as typical documentation for one-way missions and does include data from several institutions, which need to be unified. Dedicated resources need to be provided for acquiring and archiving appropriate documents in one location with easy access for decades. - Dedicated, knowledgeable contamination control oversight should be provided at sites of fabrication and integration. Numerous excellent Genesis chemists and analytical facilities participated in the contamination oversight; however, additional oversight at fabrication sites would have been helpful.

Allton, J. H.↗

Center for Isotope Cosmochemistry and Geochronology at NASA Johnson Space Center

Ten years in the making the Center for Isotope Cosmochemistry and Geochronology (CICG) at NASA Johnson Space Center is designed to be a cooperative analytical facility where novel techniques are developed and performed. Our team works collaboratively to operate this integrated lab suite comprising sample preparation, metal-free clean chemistry, and mass spectrometers to measure a wide variety of elements and isotopes in astromaterials. Contamination control is enacted throughout by a positive pressure cascade of HEPA filtered air, weekly surface cleaning and particle counting. Astromaterials processing is performed with application-specific mortar and pestles, heavy liquid separation, a Frantz magnetic separator, as well as hand-picking using optical microscopes in laminar flow boxes. Microsampling is also carried out using a New Wave MicroMill. Elements for isotopic analysis are isolated from acid-digested samples using ion-exchange chromatography. Cross-contamination is minimized with dedicated laminar flow boxes and labware for different purification protocols. Instrumentation includes a ThermoFisher Element XR inductively coupled plasma mass spectrometer (ICP-MS) for quantification of elemental concentrations in dissolved sample solutions. For in situ analysis, a Teledyne Photon Machines Analyte Excite+ laser ablation system is coupled to the Element XR. The ThermoFisher Triton thermal ionization mass spectrometer (TIMS) is used to measure the isotopic composition of elements such as CA, K, Cr, Rb, Sr, Sm, Nd at high precision in processed samples. For a more diverse range of isotopic analyses, CICG houses a Nu Sapphire 1700 multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS), which is a large geometry instrument with a multi-pole collision cell for interference removal. An Applied Spectra Instruments J200 femto-second laser is planned for install this Fall and will be coupled to the Nu Sapphire 1700. NASA’s Internal Scientist Funding Model (ISFM)supports this facility. Advanced analytical geochemistry techniques are applied to targeted astromaterials to address important problems in planetary sciences, with a longer-term goal of preparing for samples collected and returned by space missions. CICG is open to collaborations on projects that utilize the facility’s unique capabilities and are within its research scope. We are particularly eager to support and share expertise with the next generation of planetary scientists.

Justin I Simon↗

Nano Icy Moons Propellant Harvester

As one of just a few bodies identified in the solar system with a liquid ocean, Europa has become a top priority in the search for life outside of Earth. However, cost estimates for exploring Europa have been prohibitively expensive, with estimates of a NASA Flagship class orbiter and lander approaching $5 billion. ExoTerra's NIMPH offers an affordable solution that can not only land, but return a sample from the surface to Earth. NIMPH combines solar electric propulsion (SEP) technologies being developed for the asteroid redirect mission and microsatellite electronics to reduce the cost of a full sample return mission below $500 million. A key to achieving this order-of-magnitude cost reduction is minimizing the initial mass of the system. The cost of any mission is directly proportional to its mass. By keeping the mission within the constraints of an Atlas V 551 launch vehicle versus an SLS, we can significantly reduce launch costs. To achieve this we reduce the landed mass of the sample return lander, which is the largest multiplier of mission mass, and shrink propellant mass through high efficiency SEP and gravity assists. The NIMPH projects first step in reducing landed mass focuses on development of a micro-In Situ Resource Utilization (micro-ISRU) system. ISRU allows us to minimize landed mass of a sample return mission by converting local ice into propellants. The project reduces the ISRU system to a CubeSat-scale package that weighs just 1.74 kg and consumes just 242 W of power. We estimate that use of this ISRU vs. an identical micro-lander without ISRU reduces fuel mass by 45 kg. As the dry mass of the lander grows for larger missions, these savings scale exponentially. Taking full advantage of the micro-ISRU system requires the development of a micro-liquid oxygen-liquid hydrogen engine. The micro-liquid oxygen-liquid hydrogen engine is tailored for the mission by scaling it to match the scale of the micro-lander and the low gravity of the target moon. We also tailor the engine for a near stoichiometric mixture ratio of 7.5. Most high-performance liquid oxygen-liquid hydrogen engines inject extra liquid hydrogen to lower the average molecular weight of the exhaust, which improves specific impulse. However, this extra liquid hydroden requires additional power and processing time on the surface for the ISRU to create. This increases mission cost, and on missions within high radiation environments such as Europa, increases radiation shielding mass. The resulting engine weighs just 1.36 kg and produces 71.5 newton of thrust at 364 s specific impulse. Finally, the mission reduces landed mass by taking advantage of the SEP modules solar power to beam energy to the surface using a collimated laser. This allows us to replace an 45 kg MMRTG with a 2.5 kg resonant array. By using the combination of ISRU, a liquid oxygen-liquid hydrogen engine, and beamed power, we reduce the initial mass of the lander to just 51.5 kg. When combined with an SEP module to ferry the lander to Europa the initial mission mass is just 6397 kg - low enough to be placed on an Earth escape trajectory using an Atlas V 551 launch vehicle. By comparison, we estimate a duplicate lander using an MMRTG and semi-storable propellants such as liquid oxygen-methane would result in an order of magnitude increase in initial lander mass to 445 kg. Attempting to perform the trajectory with a 450 s liquid oxygen-liquid hydrogen engine would increase initial mass to approximately 135,000 kg. Using an Atlas V 1 U.S. Dollar per kg rate to Earth escape value of $27.7k per kg, just the launch savings are over $3.5 billion.

liquid↗

Lunar carbon chemistry - Relations to and implications for terrestrial organic geochemistry.

Survey of the various ways in which studies of lunar carbon chemistry have beneficially affected terrestrial organic geochemistry. A lunar organic gas-analysis operating system is cited as the most important instrumental development in relation to terrestrial organic geochemistry. Improved methods of analysis and handling of organic samples are cited as another benefit derived from studies of lunar carbon chemistry. The problem of controlling contamination and minimizing organic vapors is considered, as well as the possibility of analyzing terrestrial samples by the techniques developed for lunar samples. A need for new methods of analyzing carbonaceous material which is insoluble in organic solvents is indicated.

Eglinton, G.↗

Improving Computational Efficiency of Prognostics Algorithms in Resource-Constrained Settings

The field of prognostics and health management provides quantitative methods for monitoring and predicting the health of physical systems. Prognostics algorithms are useful in that they can be employed to assess the current state of a system, propagate the system state throughout time, and predict potential anomalies or failures that may occur. However, effective prognosis can be challenging to achieve in resource-constrained settings due to computational limitations and high computational latency, leading to obsolete predictions. Thus, computationally efficient and accurate algorithms are necessary for some prognostics applications. In this work, we implement three new algorithmic approaches to prediction (sampling methods, variable prediction time step, variable prediction sample size) with the goal of improving computational efficiency while minimizing decrease in model accuracy. To quantitatively analyze our results, we examine a use-case of degradation of a Lithium-ion battery. Notably, through this work it was found that none of the sampling approaches had a significant impact on computational efficiency or model accuracy in predicting EOD of the battery. However, our results show that prediction accuracy is highly dependent on the time step used, and that an appropriate time step can optimize both model accuracy and simulation efficiency. Finally, implementing a variable sample size also affected prediction, and our results show that tuning both the magnitude and timing of the sample size adjustment in an application-specific manner may prove useful in some applications. Taken together, our findings highlight the challenge of performing prognostics in resource-constrained settings, and illustrate the potential of developing new prediction algorithms to improve computational efficiency of prognosis.

Prognostics↗

Elevating the Quality of Space Omics Sequencing Data: Innovations and Methodologies from NASA GeneLab Sample Processing Laboratory

NASA’s GeneLab, part of the NASA Open Science Data Repository, is a space-related database that hosts a diverse range of transcriptomics, proteomics, epigenomics and genomics data. The NASA GeneLab Sample Processing Laboratory (SPL) generates omics data from biological experiments conducted aboard the International Space Station, Space Shuttle and space related ground experiments, this omics data then hosted on the GeneLab repository. Samples generated such experiments pose numerous technical challenges such as small experimental sample size, variance in dissection times, limited tissue preservation methods, prolonged storage time, and more. GeneLab SPL team had developed specialized expertise in nucleic acid extraction, library preparation and sequencing of such biological samples via extensive training and years of experience. In order to ensure data accuracy and consistency across experiments, SPL has developed standardized protocols for each species and tissue type. These protocols in conjunction with quality control metrics and data standards are crucial in generating of high-quality data. SPL protocols and standards have been developed in collaboration with the scientific community and had been made publicly available on the GeneLab portal, guaranteeing comparability of datasets across spaceflight experiments. To ensure reliability of data generation, SPL leverages cutting-edge innovations in laboratory automation for sample processing. By leveraging these state-of-the-art platforms, SPL achieves high levels of data reproducibility while significantly minimizing sources of bias and variability, especially across experiments with large numbers of samples. Over the past few years, the space biology investigator community has accessed SPL-generated data from the Open Science Data Repository for a myriad of data re-analysis and re-use studies. We observe a trend that in-house SPL-generated data consistently outperforms outsourced sequencing data in terms of technical standards, quality control metrics, timeliness of data delivery, and sequencing and reagent efficiency. Superior data generation has and will continue to enable discoveries in disease, diagnostic tools, and the biological effects of long duration spaceflight.

GeneLab↗

Elevating the Quality of Space Omics Sequencing Data: Innovations and Methodologies from NASA GeneLab Sample Processing Laboratory

NASA’s GeneLab, part of the NASA Open Science Data Repository, is a space-related database that hosts a diverse range of transcriptomics, proteomics, epigenomics and genomics data. The NASA GeneLab Sample Processing Laboratory (SPL) generates omics data from biological experiments conducted aboard the International Space Station, Space Shuttle and space related ground experiments, this omics data then hosted on the GeneLab repository. Samples generated such experiments pose numerous technical challenges such as small experimental sample size, variance in dissection times, limited tissue preservation methods, prolonged storage time, and more. GeneLab SPL team had developed specialized expertise in nucleic acid extraction, library preparation and sequencing of such biological samples via extensive training and years of experience. In order to ensure data accuracy and consistency across experiments, SPL has developed standardized protocols for each species and tissue type. These protocols in conjunction with quality control metrics and data standards are crucial in generating of high-quality data. SPL protocols and standards have been developed in collaboration with the scientific community and had been made publicly available on the GeneLab portal, guaranteeing comparability of datasets across spaceflight experiments. To ensure reliability of data generation, SPL leverages cutting-edge innovations in laboratory automation for sample processing. By leveraging these state-of-the-art platforms, SPL achieves high levels of data reproducibility while significantly minimizing sources of bias and variability, especially across experiments with large numbers of samples. Over the past few years, the space biology investigator community has accessed SPL-generated data from the Open Science Data Repository for a myriad of data re-analysis and re-use studies. We observe a trend that in-house SPL-generated data consistently outperforms outsourced sequencing data in terms of technical standards, quality control metrics, timeliness of data delivery, and sequencing and reagent efficiency. Superior data generation has and will continue to enable discoveries in disease, diagnostic tools, and the biological effects of long duration spaceflight.

GeneLab↗

Remotely Controlled Mixers for Light Microscopy Module (LMM) Colloid Samples

Developed by NASA Glenn Research Center, the LMM aboard the International Space Station (ISS) is enabling multiple biomedical science experiments. Techshot, Inc., has developed a series of colloid specialty cell systems (C-SPECS) for use in the colloid science experiment module on the LMM. These low-volume mixing devices will enable uniform particle density and remotely controlled repetition of LMM colloid experiments. By automating the experiment process, C-SPECS allow colloid samples to be processed more quickly. In addition, C-SPECS will minimize the time the crew will need to spend on colloid experiments as well as eliminate the need for multiple and costly colloid samples, which are expended after a single examination. This high-throughput capability will lead to more efficient and productive use of the LMM. As commercial launch vehicles begin routine visits to the ISS, C-SPECS could become a significant means to process larger quantities of high-value materials for commercial customers.

Kurk, Michael A. (Andy)↗

OSIRIS-REx: Curating Samples from the Carbon rich Asteroid Bennu

The OSIRIS REx mission returned 121 g of pristine material from the asteroid Bennu. This talk will describe the how the sample was collected, returned to earth, retrieved, and how it is currently being curated at the NASA Johnson Space Center. In order to keep the samples pristine they are kept under an ultra pure nitrogen atomosphere inside and ISO 5 equivalent clean room. Special care is taken not to expose the samples to oxygen, or organic contaminants. NASA has implemented additional procedures to minimize the likelihood of biological contamination. The presentation will also include a brief description of the preliminary results from initial study of the samples.

Aaron B. Regberg↗

Synthetic seawater as stress-corrosion test medium

Seawater minimizes pitting corrosion of aluminum-alloy test samples. Of three corrosion-inhibiting methods evaluated using (a) chromate inhibitors in saltwater, (b) surface treating sample via anodizing or alodine treatment, and (c) synthetic seawater, synthetic seawater was most effective test medium, since it is more uniform than fresh seawater.

Humphries, T. S.↗

Reluctant glass formers and their applications in optical lens design

Over ten years ago, it was shown that glasses with high index of refraction and some with low dispersion could be produced from a number of pure refractory oxides, including the lanthanides, by containerless processing. By containerless processing it is possible to minimize surface heterogeneous nucleation and produce larger glass samples of the materials than by other methods. The use of proposed high temperature containerless processing facilities in space permits the fabrication of benchmark samples of new unique glass compositions for optical property determination as well as for glass formation. It was shown that glasses with high refractive indices and large Abbe numbers can be formulated using this technology. These glasses lie in the classical forbidden region of the glass map. Preliminary study of the impact of having such unusual glasses available for the lens designer was made. Results indicate that significant improvements can be realized over the use of only conventional glasses. A cursory survey of a number of nationally recognized lens designers indicated a general agreement that such glasses would be highly desired and could be expected to lead to completely new designs as well as simplifying existing designs.

Ethridge, Edwin C.↗

Microfluidic Mixing Technology for a Universal Health Sensor

A highly efficient means of microfluidic mixing has been created for use with the rHEALTH sensor an elliptical mixer and passive curvilinear mixing patterns. The rHEALTH sensor provides rapid, handheld, complete blood count, cell differential counts, electrolyte measurements, and other lab tests based on a reusable, flow-based microfluidic platform. These geometries allow for cleaning in a reusable manner, and also allow for complete mixing of fluid streams. The microfluidic mixing is performed by flowing two streams of fluid into an elliptical or curvilinear design that allows the combination of the flows into one channel. The mixing is accomplished by either chaotic advection around micro - fluidic loops. All components of the microfluidic chip are flow-through, meaning that cleaning solution can be introduced into the chip to flush out cells, plasma proteins, and dye. Tests were performed on multiple chip geometries to show that cleaning is efficient in any flowthrough design. The conclusion from these experiments is that the chip can indeed be flushed out with microliter volumes of solution and biological samples are cleaned readily from the chip with minimal effort. The technology can be applied in real-time health monitoring at patient s bedside or in a doctor s office, and real-time clinical intervention in acute situations. It also can be used for daily measurement of hematocrit for patients on anticoagulant drugs, or to detect acute myocardial damage outside a hospital.

Chan, Eugene Y.↗

Sampling and Reconstruction of the Pupil and Electric Field for Phase Retrieval

This technology is based on sampling considerations for a band-limited function, which has application to optical estimation generally, and to phase retrieval specifically. The analysis begins with the observation that the Fourier transform of an optical aperture function (pupil) can be implemented with minimal aliasing for Q values down to Q = 1. The sampling ratio, Q, is defined as the ratio of the sampling frequency to the band-limited cut-off frequency. The analytical results are given using a 1-d aperture function, and with the electric field defined by the band-limited sinc(x) function. Perfect reconstruction of the Fourier transform (electric field) is derived using the Whittaker-Shannon sampling theorem for 1<Q<2. The Fourier transform is constructed by periodic extension, i.e., by spacing copies of the transform in a definite way, recognizing that no aliasing occurs for values of the sampling ratio such that 1<Q<2, which can be used to advantage in the application of phase retrieval estimation. A method was developed for propagating the electro magnetic field with no aliasing, which has been extended to 2-d optical apertures.

Dean, Bruce↗

Palmer Station, Antarctica: A Ground-Based Spaceflight Analog Suitable for Validation of Biomedical Countermeasures for Deep Space Missions

Astronauts are known to exhibit a variety of immunological alterations during spaceflight including changes in leukocyte distribution and plasma cytokine concentrations, a reduction in T-cell function, and subclinical reactivation of latent herpesviruses. These alterations are most likely due to mission-associated stressors including circadian misalignment, microgravity, isolation, altered nutrition, and increased exposure to cosmic radiation. Some of these stressors may also occur in terrestrial situations. This study sought to determine if crewmembers performing overwinter deployment at Palmer Station, Antarctica displayed similar immune alterations. The larger goal was to validate a ground analog suitable for the evaluation of countermeasures designed to protect astronauts during future deep space missions. For this pilot study, plasma, saliva, hair, and health surveys were collected from Palmer Station, Antarctica winterover participants at baseline, and at five overwinter timepoints. Twenty-six subjects consented to participate over the course of two seasons. Initial sample processing was performed at Palmer, and eventually stabilized samples were returned to the Johnson Space Center for analysis. A white blood cell differential was performed (real time) using a fingerstick blood sample to determine alterations in basic leukocyte subsets throughout the winterover. Plasma and saliva samples were analyzed for 30 and 13 cytokines, respectively. Saliva was analyzed for cortisol concentration and three latent herpesviruses (DNA by qPCR), EBV, HSV1, and VZV. Hair samples were analyzed for several hormones, as a measure of stress over prolonged periods of time. Voluntary surveys related to general health and adverse clinical events were distributed to participants. It is noteworthy that due to logistical constraints due to COVID-19, the baseline samples for each season were collected in Punta Arenas, Chile, after long international travel and during isolation. Therefore, the palmer pre mission samples may not reflect a true normal ‘baseline’. Minimal alterations were observed in leukocyte distribution during overwinter. The mean percentage of monocyte concentration elevated at one timepoint. Plasma G-CSF, IL1RA, MCP-1, MIP-1β, TNFα and VEGF were decreased during at least one overwinter timepoint, whereas RANTES was significantly increased. No statistically significant changes were observed in mean saliva cytokine concentrations. Salivary cortisol was substantially elevated throughout the entire winterover compared to baseline. Compared to shedding levels observed in healthy controls (23%), the percentage of participants who shed EBV was higher throughout all winterover timepoints (52-60%). Five subjects shed HSV1 during at least one timepoint throughout the season compared to no subjects shedding during pre-deployment. Finally, VZV reactivation, common in astronauts but exceptionally rare in ground-based stress analogs, was observed in one subject during pre-deployment and a different subject at WO2 and WO3. These pilot data, somewhat influenced by the COVID-19 situation, do suggest that participants at Palmer Station do undergo immunological alterations similar to, but likely in reduced magnitude, as those observed in astronauts. We suggest that overwinter at Palmer Station may be suitable test analog for spaceflight biomedical countermeasures designed to mitigate clinical risks for deep space missions.

Space↗

A Compendium of Scale Surface Microstructures: Ni(pt)al Coatings Oxidized at 1150 C for 2000 1-h Cycles

The surface structure of scales formed on Ni(Pt)Al coatings was characterized by SEM/EDS/BSE in plan view. Two nominally identical {100} samples of aluminide coated CMSX4 single crystal were oxidized at 1150 C for 2000 1-h cycles and were found to produce somewhat disparate behavior. One sample, with less propensity for coating grain boundary ridge deformation, presented primarily alpha-Al2O3 scale structures, with minimal weight loss and spallation. The original scale structure, still retained over most of the sample, consisted of the classic theta-alpha transformation-induced ridge network structure, with approx. 25 nm crystallographic steps and terraces indicative of surface rearrangement to low energy alumina planes. The scale grain boundary ridges were often decorated with a fine, uniform distribution of (Hf,Ti)O2 particles. Another sample, producing steady state weight losses, exhibited much interfacial spallation and a complex assortment of different structures. Broad areas of interfacial spalling, crystallographically-faceted (Ni,Co)(Al,Cr)2O4 spinel, with an alpha-Al2O3 base scale, were the dominant features. Other regions exhibited nodular spinel grains, with fine or (Ta,Ti)-rich (rutile) particles decorating or interspersed with the spinel. While these features were consistent with a coating that presented more deformation at extruded grain boundaries, the root cause of the different behavior between the duplicate samples could not be conclusively identified.

Smialek, James L.↗