Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Multi-element stochastic spectral projection for high quantile estimation

We investigate quantile estimation by multi-element generalized Polynomial Chaos (gPC) metamodel where the exact numerical model is approximated by complementary metamodels in overlapping domains that mimic the model’s exact response. The gPC metamodel is constructed by the non-intrusive stochastic spectral projection approach and function evaluation on the gPC metamodel can be considered as essentially free. Thus, large number of Monte Carlo samples from the metamodel can be used to estimate α-quantile, for moderate values of α. As the gPC metamodel is an expansion about the means of the inputs, its accuracy may worsen away from these mean values where the extreme events may occur. By increasing the approximation accuracy of the metamodel, we may eventually improve accuracy of quantile estimation but it is very expensive. A multi-element approach is therefore proposed by combining a global metamodel in the standard normal space with supplementary local metamodels constructed in bounded domains about the design points corresponding to the extreme events. To improve the accuracy and to minimize the sampling cost, sparse-tensor and anisotropic-tensor quadratures are tested in addition to the full-tensor Gauss quadrature in the construction of local metamodels; different bounds of the gPC expansion are also examined. The global and local metamodels are combined in the multi-element gPC (MEgPC) approach and it is shown that MEgPC can be more accurate than Monte Carlo or importance sampling methods for high quantile estimations for input dimensions roughly below N=8, a limit that is very much case- and α-dependent.

97 MATHEMATICS AND COMPUTING↗

Efficient learning of accurate surrogates for simulations of complex systems

Machine learning methods are increasingly deployed to construct surrogate models for complex physical systems at a reduced computational cost. However, the predictive capability of these surrogates degrades in the presence of noisy, sparse or dynamic data. Here, we introduce an online learning method empowered by optimizer-driven sampling that has two advantages over current approaches: it ensures that all local extrema (including endpoints) of the model response surface are included in the training data, and it employs a continuous validation and update process in which surrogates undergo retraining when their performance falls below a validity threshold. We find, using benchmark functions, that optimizer-directed sampling generally outperforms traditional sampling methods in terms of accuracy around local extrema even when the scoring metric is biased towards assessing overall accuracy. Finally, the application to dense nuclear matter demonstrates that highly accurate surrogates for a nuclear equation-of-state model can be reliably autogenerated from expensive calculations using few model evaluations.

79 ASTRONOMY AND ASTROPHYSICS↗

Mitigation of the Brighter-Fatter Effect in the LSST Camera

Thick, fully depleted charge-coupled devices (CCDs) are known to exhibit non-linear behavior at high signal levels due to the dynamic behavior of charges collecting in the potential wells of pixels, called the brighter-fatter effect (BFE). This particularly impacts bright calibration stars, which appear larger than their intrinsic shape, creating a flux-dependent point-spread function (PSF) that if left unmitigated, could make up a large fraction of the error budget in Stage IV weak-lensing (WL) surveys such as the Legacy Survey of Space and Time (LSST). In this paper, we analyze image measurements of flat fields and artificial stars taken at different illumination levels with the LSST Camera (LSSTCam) at SLAC National Accelerator Laboratory in order to quantify this effect in the LSST Camera before and after a previously introduced correction technique. We observe that the BFE evolves anisotropically as a function of flux due to higher-order BFEs, which violates the fundamental assumption of this correction method. We then introduce a new sampling method based on a physically motivated model to account these higher-order terms in the correction, and then we test the modified correction on both datasets. We find that the new method corrects the effect in flat fields better than it corrects the effect in artificial stars which we conclude is the result of a unmodeled curl component of the deflection field by the correction. We use these results to define a new metric for the full-well capacity of our sensors and advise image processing strategies to further limit the impact of the effect on LSST WL science pathways.

47 OTHER INSTRUMENTATION↗

Efficient Learning of Accurate Surrogates for Simulations of Complex Systems

Machine learning methods are increasingly deployed to construct surrogate models for complex physical systems at a reduced computational cost. However, the predictive capability of these surrogates degrades in the presence of noisy, sparse, or dynamic data. We introduce an online learning method empowered by optimizer-driven sampling that has two advantages over current approaches: it ensures that all local extrema (including endpoints) of the model response surface are included in the training data and it employs a continuous validation and update process in which surrogates undergo retraining when their performance falls below a validity threshold. We find, using benchmark functions, that optimizer-directed sampling generally outperforms traditional sampling methods in terms of accuracy around local extrema even when the scoring metric is biased towards assessing overall accuracy. Finally, the application to dense nuclear matter demonstrates that highly accurate surrogates for a nuclear equation of state model can be reliably auto-generated from expensive calculations using few model evaluations.

97 MATHEMATICS AND COMPUTING↗

Correlation function distributions for O ( N ) lattice field theories in the disordered phase

Numerical computations in strongly interacting quantum field theories are often performed using Monte Carlo sampling methods. A key task in these calculations is to estimate the value of a given physical quantity from the distribution of stochastic samples that are generated using the Monte Carlo method. Typically, the sample mean and sample variance are used to define the expectation values and uncertainties of computed quantities. However, the Monte Carlo sample distribution contains more information than these basic properties, and it is useful to investigate it more generally. In this work, the exact form of the probability distributions of two-point correlation functions at zero momentum in O ( N ) lattice field theories in the disordered phase and in infinite volume are determined. These distributions allow for a robust investigation of the efficacy of the Monte Carlo sampling procedure and are shown also to allow for improved estimators of the target physical quantity to be constructed. The theoretical expectations are shown to agree with numerical calculations in the O ( 2 ) model. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Statistical data analysis of x-ray spectroscopy data enabled by neural network accelerated Bayesian inference

Bayesian inference applied to x-ray spectroscopy data analysis enables uncertainty quantification necessary to rigorously test theoretical models. However, when comparing to data, detailed atomic physics and radiation transfer calculations of x-ray emission from non-uniform plasma conditions are typically too slow to be performed in line with statistical sampling methods, such as Markov Chain Monte Carlo sampling. Furthermore, differences in transition energies and x-ray opacities often make direct comparisons between simulated and measured spectra unreliable. Here, we present a spectral decomposition method that allows for corrections to line positions and bound–bound opacities to best fit experimental data, with the goal of providing quantitative feedback to improve the underlying theoretical models and guide future experiments. In this work, we use a neural network (NN) surrogate model to replace spectral calculations of isobaric hot-spots created in Kr-doped implosions at the National Ignition Facility. The NN was trained on calculations of x-ray spectra using an isobaric hot-spot model post-processed with Cretin, a multi-species atomic kinetics and radiation code. The speedup provided by the NN model to generate x-ray emission spectra enables statistical analysis of parameterized models with sufficient detail to accurately represent the physical system and extract the plasma parameters of interest.

47 OTHER INSTRUMENTATION↗

Field expedient stool collection methods for gut microbiome analysis in deployed military environments

ABSTRACT Field expedient devices and protocols for the collection, storage, and shipment of stool samples in deployed settings are needed for the advancement of microbiome research in military health. Relevant assessments include the evaluation of microbiome signatures associated with susceptibility to travelers’ diarrhea and recovery of gut function following infection. However, inherent biases in microbial measurements due to preservatives and sampling methods are unclear and should be assessed for an accurate evaluation of the microbiome. We performed shotgun metagenomic sequencing and compared the microbiome composition in paired fecal samples collected using Flinters Technology Associates (FTA) cards and OMNIgene (OG) Gut tubes, prior to and during international travel, from 49 adult participants, 39 of whom remained asymptomatic and 10 experienced travelers’ diarrhea. Higher concentrations of nucleic acid and sequencing libraries were observed in OG samples. A majority of genera (82.9%) were detected with both methods, and detections of genera limited to one collection method were not highly prevalent across samples and were present in extremely low relative abundances (<0.01%). Differences in beta diversity were largely explained by inter-individuality of microbiome composition, followed by the effect of collection method and timepoint-disease states. Differential abundance analysis indicated that Corynebacterium and Blautia were consistently higher in abundance across all groups with FTA and OG collection, respectively. The observed differences in microbiome composition between methods suggest the need for consistent and standardized protocols within a study. Overall, the data presented here could help guide the future design of fecal microbiome study protocols in field and military deployment settings. IMPORTANCE The assessment of field-deployable methods for fecal sample collection and storage is required to reliably capture samples collected in remote and austere locations. This study describes a comparative metagenomics analysis between samples collected by two different commercially available methods in a military-deployed setting. The results presented here are foundational for the future design of fecal microbiome study protocols in an operational context.

field study↗

Making Steppingstones out of Stumbling Blocks: A Bayesian Model Evidence Estimator with Application to Groundwater Transport Model Selection

Bayesian model evidence (BME) is a measure of the average fit of a model to observation data given all the parameter values that the model can assume. By accounting for the trade-off between goodness-of-fit and model complexity, BME is used for model selection and model averaging purposes. For strict Bayesian computation, the theoretically unbiased Monte Carlo based numerical estimators are preferred over semi-analytical solutions. This study examines five BME numerical estimators and asks how accurate estimation of the BME is important for penalizing model complexity. The limiting cases for numerical BME estimators are the prior sampling arithmetic mean estimator (AM) and the posterior sampling harmonic mean (HM) estimator, which are straightforward to implement, yet they result in underestimation and overestimation, respectively. We also consider the path sampling methods of thermodynamic integration (TI) and steppingstone sampling (SS) that sample multiple intermediate distributions that link the prior and the posterior. Although TI and SS are theoretically unbiased estimators, they could have a bias in practice arising from numerical implementation. For example, sampling errors of some intermediate distributions can introduce bias. We propose a variant of SS, namely the multiple one-steppingstone sampling (MOSS) that is less sensitive to sampling errors. We evaluate these five estimators using a groundwater transport model selection problem. SS and MOSS give the least biased BME estimation at an efficient computational cost. If the estimated BME has a bias that covariates with the true BME, this would not be a problem because we are interested in BME ratios and not their absolute values. On the contrary, the results show that BME estimation bias can be a function of model complexity. Thus, biased BME estimation results in inaccurate penalization of more complex models, which changes the model ranking. This was less observed with SS and MOSS as with the three other methods.

54 ENVIRONMENTAL SCIENCES↗

A practical perspective on the implementation of hyperdynamics for accelerated simulation

Consideration is given to several practical issues arising during the implementation of hyperdynamics, a methodology that extends the time scale of the conventional molecular dynamics simulation potentially by orders of magnitude. First, the methodology is reformulated in terms of the transition rate based on the buffer region approach (buffer rate), which can describe transitions in more general contexts than the transition state theory (TST). It will be shown that hyperdynamics can exactly preserve the buffer rate as well as the TST rate, which broadens the scope of the method. Next, the originally proposed scheme to compute the boost factor on-the-fly is reviewed and some alternative methods, one of which uses the umbrella sampling method, are presented. Finally, the methodology is validated in the context of a 1-dimensional example potential and a 3-dimensional simulation of the motion of an atomic force microscope tip moving along a surface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Iron corrosion in the “inert” supercritical CO 2 , ab initio dynamics insights: How impurities matter

Metal corrosion from exposure to supercritical fluids is a long-standing challenge lacking atomistic understanding for effective corrosion prevention in diverse important applications. Here, in this work, reactions relevant to corrosion in supercritical CO 2 (sCO 2 ), with H 2 O and NO 2 as impurities, are revealed using ab initio molecular dynamics and enhanced sampling methods. While little reactivity is observed in bulk sCO 2 , the iron surface is found to play a crucial almost-catalytic role in its own corrosion, activating the inert CO2 and hence facilitating $\ast$HCO 3 – and $\ast$CO 3 2– formation at the interface. Moreover, the hydrogen bond network of $\ast$H 2 O assists the H shuttling to the activated CO 2 and impurities, forming reactive species observed in experiments. Such atomistic insight elucidates the reaction mechanisms of metal corrosion in aqueous and supercritical fluids and can point to possible remedies.

36 MATERIALS SCIENCE↗

Enhanced AFCI Sampling, Analysis, and Safeguards Technology Review

The focus of this study includes the investigation of sampling technologies used in industry and their potential application to nuclear fuel processing. The goal is to identify innovative sampling methods using state of the art techniques that could evolve into the next generation sampling and analysis system for metallic elements. Sampling and analysis of nuclear fuel recycling plant processes is required both to monitor the operations and ensure Safeguards and Security goals are met. In addition, environmental regulations lead to additional samples and analysis to meet licensing requirements. The volume of samples taken by conventional means, can restrain productivity while results samples are analyzed, require process holding tanks that are sized to meet analytical issues rather than process issues (and that create a larger facility footprint), or, in some cases, simply overwhelm analytical laboratory capabilities. These issues only grow when process flowsheets propose new separations systems and new byproduct material for transmutation purposes. Novel means of streamlining both sampling and analysis are being evaluated to increase the efficiency while meeting all requirements for information. This report addresses just a part of the effort to develop and study novel methods by focusing on the sampling and analysis of aqueous samples for metallic elements. It presents an overview of the sampling requirements, including frequency, sensitivity, accuracy, and programmatic drivers, to demonstrate the magnitude of the task. The sampling and analysis system needed for metallic element measurements is then discussed, and novel options being applied to other industrial analytical needs are presented. Inductively coupled mass spectrometry instruments are the most versatile for metallic element analyses and are thus chosen as the focus for the study. Candidate novel means of process sampling, as well as modifications that are necessary to couple such instruments to introduce these samples, are discussed. A suggested path forward based on an automated microchip capillary based sampling system interfaced to the analysis spectrometer is presented. The ability to obtain micro liter volume samples coupled with remote automated means of sample tracking and transport to the instrument would greatly improve analytical efficiency while reducing both personnel exposure and radioactive waste. Application of this sampling technique to new types of mass spectrometers for selective elemental isotopic analysis could also provide significant improvements in safeguards and security analyses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Kraken2 Metagenomic Virus Database

The Database: Kraken2 [1] database built from a classification tree containing over 700k metagenomic viruses from JGI IMG/VR [2]. (1) Wood, D. E., Lu, J., and Langmead, B. (2019). Improved metagenomic analysis with Kraken 2. Genome Biol., 20(1), 1–13. doi: 10.1186/s13059-019-1891-0 (2) Paez-Espino D, Chen I-MA, Palaniappan K, Ratner A, Chu K, Szeto E, et al. IMG/VR: a database of cultured and uncultured DNA Viruses and retroviruses. Nucleic Acids Res. 2017;45:D457-65. For Paper: Title: A k-mer based approach for virus classification in metatranscriptomic and metagenomic samples identifies viral associations in the Populus phytobiome and autism brains Abstract Background Viruses are an underrepresented taxa in the study and identification of microbiome constituents; however, they play an important role in health, microbiome regulation, and transfer of genetic material. Only a few thousand viruses have been isolated, sequenced, and assigned a taxonomy, which further limits the ability to identify and quantify viruses in the microbiome. Additionally, the vast diversity of viruses represents a challenge for classification, not only in constructing a viral taxonomy, but also in identifying similarities between a virus' genotype and its phenotype. However, the diversity of viral sequences can be leveraged to classify their sequences in metagenomic and metatranscriptomic samples. Methods To identify viruses in transcriptomic and genomic samples, we developed a dynamic programming algorithm for creating a classification tree out of 715,672 metagenome viruses. To create the classification tree, we clustered proportional similarity scores generated from the k-mer profiles of each of the metagenome viruses. We then integrated the viral classification tree with the NCBI taxonomy for use with ParaKraken, a metagenomic/transcriptomic classifier. Results To illustrate the breadth of our utility for classifying viruses with ParaKraken, we analyzed data from a plant metagenome study identifying the differences between two Populus genotypes in three different compartments and on a human metatranscriptome study identifying the differences between Autism Spectrum Disorder patients and controls in post mortem brain biopsies. In the Populus study, we identified genotype and compartment specific viral signatures, while in the Autism study we identified a significant increased abundance of eight viral sequences in Autism brain biopsies. Conclusion Viruses represent an important aspect of the microbiome. The ability to classify viruses represents the first step in being able to better understand their role in the microbiome. The viral classification method presented here allows for more complete identification of viral sequences for use in identifying associations between viruses and the host and viruses and other microbiome members. Acknowledgements and Funding This research used resources of the Oak Ridge Leadership Computing Facility at the Oak Ridge National Laboratory, which is supported by the Office of Science of the U.S. Department of Energy under Contract No. DE-AC05-00OR22725. This research was also supported by the Plant-Microbe Interfaces Scientific Focus Area in the Genomic Science Program, the Office of Biological and Environmental Research (BER) in the U.S. Department of Energy Office of Science, and by the Department of Energy, Laboratory Directed Research and Development funding (ProjectID 8321), at the Oak Ridge National Laboratory. Oak Ridge National Laboratory is managed by UT-Battelle, LLC, for the US DOE under contract DE-AC05-00OR22725. This research used resources of the Compute and Data Environment for Science (CADES).

59 BASIC BIOLOGICAL SCIENCES↗

Comparison of XSUSA and "Two-Step" Approaches for Full Core Uncertainty Quantification

While there are multiple sources of error that are introduced into the standard computational regime for simulating reactor cores, rigorous uncertainty analysis methods are available primarily for quantifying the effects of cross section uncertainties. Two methods for propagating cross section uncertainties through core simulators are the XSUSA statistical approach and the 'Two-Step' method. The XSUSA approach, which is based on the SUSA code package, is fundamentally a stochastic sampling method. Alternatively, the Two-Step method utilizes generalized perturbation theory in the first step and stochastic sampling in the second step. The consistency of these two methods in quantifying uncertainties in the multiplication factor and in the core power distribution will be examined in the framework of phase I-3 of the UAM Benchmark. Using the TMI core as a base model for analysis, the XSUSA and Two-Step methods are applied with certain limitations and the results are compared to those produced by other stochastic sampling-based codes. Based on the uncertainty analysis results, conclusions are made for which method is currently a more viable option for computing uncertainties in burnup and transient calculations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparison of XSUSA and 'two-step' approaches for full-core uncertainty quantification

While there are multiple sources of error that are introduced into the standard computational regime for simulating reactor cores, rigorous uncertainty analysis methods are available primarily for quantifying the effects of cross section uncertainties. Two methods for propagating cross section uncertainties through core simulators are the XSUSA statistical approach and the 'Two-Step' method. The XSUSA approach, which is based on the SUSA code package, is fundamentally a stochastic sampling method. Alternatively, the Two-Step method utilizes generalized perturbation theory in the first step and stochastic sampling in the second step. The consistency of these two methods in quantifying uncertainties in the multiplication factor and in the core power distribution will be examined in the framework of phase 1-3 of the UAM Benchmark. Using the TMI core as a base model for analysis, the XSUSA and Two-Step methods are applied with certain limitations and the results are compared to those produced by other stochastic sampling-based codes. Based on the uncertainty analysis results, conclusions are made for which method is currently a more viable option for computing uncertainties in burnup and transient calculations. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Autonomous adaptive data acquisition for scanning hyperspectral imaging

Non-invasive and label-free spectral microscopy (spectromicroscopy) techniques can provide quantitative biochemical information complementary to genomic sequencing, transcriptomic profiling, and proteomic analyses. However, spectromicroscopy techniques generate high-dimensional data; acquisition of a single spectral image can range from tens of minutes to hours, depending on the desired spatial resolution and the image size. This substantially limits the timescales of observable transient biological processes. To address this challenge and move spectromicroscopy towards efficient real-time spatiochemical imaging, we developed a grid-less autonomous adaptive sampling method. Our method substantially decreases image acquisition time while increasing sampling density in regions of steeper physico-chemical gradients. When implemented with scanning Fourier Transform infrared spectromicroscopy experiments, this grid-less adaptive sampling approach outperformed standard uniform grid sampling in a two-component chemical model system and in a complex biological sample, Caenorhabditis elegans. We quantitatively and qualitatively assess the efficiency of data acquisition using performance metrics and multivariate infrared spectral analysis, respectively.

47 OTHER INSTRUMENTATION↗

Molten Salt Synthesis of Increased (100)-Facet and Polycrystalline Nickel Oxide Nanoparticles for the Oxygen Evolution Reaction: Impact of Facet and Crystallinity on Electrocatalysis

Nickel oxide nanocubes with increased (100) surface facet presence (NiO(100)) were synthesized through a molten salt synthesis procedure to probe their oxygen evolution reaction (OER) activity in order to investigate the relationship between the surface facet and OER performance. While altering the synthesis parameters to decrease NiO(100) particle sizes and agglomeration, a polycrystalline NiO nanoparticle system formed from using Li2O as a Lux-Flood base (labelled Li2O-MSS NiO, where MSS stands for molten salt synthesis). This novel synthesis was further elaborated and the obtained materials were also tested for OER activity. After thorough structural characterization to determine crystallinity, lattice spacings, and elemental distribution, their OER activity was compared versus high surface area NiO(111) nanosheets in a three-electrode rotating disk electrode (RDE) system. The activity trend of (111) > Li2O-MSS > (100) was observed. This decrease in activity of the nanocube and polycrystalline samples was explained by differences between theoretical and experimental conditions, differences in ink rheology and resulting catalyst layer properties, and significant agglomeration seen in the imaging of the sample. Methods for improving the OER activity of these samples are discussed in the conclusion of this study.

08 HYDROGEN↗

Efficient Monte Carlo event generation for neutrino-nucleus exclusive cross sections

Modern neutrino-nucleus cross section computations need to incorporate sophisticated nuclear models to achieve greater predictive precision. However, the computational complexity of these advanced models often limits their practicality for experimental analyses. To address this challenge, we introduce a new Monte Carlo method utilizing normalizing flows to generate surrogate cross sections that closely approximate those of the original model while significantly reducing computational overhead. As a case study, we built a Monte Carlo event generator for the neutrino-nucleus cross section model developed by the Ghent group. This model employs a Hartree-Fock procedure to establish a quantum mechanical framework in which both the bound and scattering nucleon states are solutions to the mean-field nuclear potential. The surrogate cross sections generated by our method demonstrate excellent accuracy with a relative effective sample size of more than 98.4%, providing a computationally efficient alternative to traditional Monte Carlo sampling methods for differential cross sections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ISOLOK VALVE ACCEPTANCE TESTING FOR DWPF SME SAMPLING PROCESS

Evaluation of the Defense Waste Processing Facility (DWPF) Chemical Process Cell (CPC) cycle time identified several opportunities to improve the CPC processing time. Of the opportunities, a focus area related to optimizing the equipment and efficiency of the sample turnaround time for DWPF Analytical Laboratory was identified. The Mechanical Systems & Custom Equipment Development (MS&CED) Section of the Savannah River National Laboratory (SRNL) evaluated the possibility of using an Isolok{reg_sign} sampling valve as an alternative to the Hydragard{reg_sign} valve for taking process samples. Previous viability testing was conducted with favorable results using the Isolok sampler and reported in SRNL-STI-2010-00749 (1). This task has the potential to improve operability, reduce maintenance time and decrease CPC cycle time. This report summarizes the results from acceptance testing which was requested in Task Technical Request (TTR) HLW-DWPF-TTR-2010-0036 (2) and which was conducted as outlined in Task Technical and Quality Assurance Plan (TTQAP) SRNL-RP-2011-00145 (3). The Isolok to be tested is the same model which was tested, qualified, and installed in the Sludge Receipt Adjustment Tank (SRAT) sample system. RW-0333P QA requirements apply to this task. This task was to qualify the Isolok sampler for use in the DWPF Slurry Mix Evaporator (SME) sampling process. The Hydragard, which is the current baseline sampling method, was used for comparison to the Isolok sampling data. The Isolok sampler is an air powered grab sampler used to 'pull' a sample volume from a process line. The operation of the sampler is shown in Figure 1. The image on the left shows the Isolok's spool extended into the process line and the image on the right shows the sampler retracted and then dispensing the liquid into the sampling container. To determine tank homogeneity, a Coliwasa sampler was used to grab samples at a high and low location within the mixing tank. Data from the two locations were compared to determine if the contents of the tank were well mixed. The Coliwasa sampler is a tube with a stopper at the bottom and is designed to obtain grab samples from specific locations within the drum contents. A position paper (4) was issued to address the prototypic flow loop issues and simulant selections. A statistically designed plan (5) was issued to address the total number of samples each sampler needed to pull, to provide the random order in which samples were pulled and to group samples for elemental analysis. The TTR required that the Isolok sampler perform as well as the Hydragard sampler during these tests to ensure the acceptability of the Isolok sampler for use in the DWPF sampling cells. Procedure No.L9.4-5015 was used to document the sample parameters and process steps. Completed procedures are located in R&D Engineering job folder 23269.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗