Search NASA⌕ Search

SEARCH · Search NASA

Results for “scanning probe microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Assessing the quality of large-area monolayer graphene grown on liquid copper for size-selective ionic/molecular membrane separations

Monolayer graphene growth on liquid copper (Cu) has attracted attention due to advantages of a flat/smooth catalytic growth surface, high synthesis temperature (>1080 °C) as well as the possibility of forming graphene domains that are mobile on the liquid Cu with potential to minimize grain boundary defects and self-assemble into a continuous monolayer film. However, the quality of monolayer graphene grown on liquid copper and its suitability for size-selective ionic/molecular membrane separations has not been evaluated/studied. Here, we probe the quality of monolayer graphene grown on liquid Cu (via a metallurgical process, HSMG ® ) using Scanning Electron Microscope (SEM), High-resolution transmission electron microscope (HR-TEM), Raman spectroscopy and report on a facile approach to assess intrinsic sub-nanometer to nanometer-scale defects over centimeter-scale areas. We demonstrate high transfer yields of monolayer graphene (>93% coverage) from the growth substrate to polyimide track etched membrane (PITEM, pore diameter ~200 nm) supports to form centimeter-scale atomically thin membranes. Next, we use pressure-driven transport of ethanol to probe defects > 60 nm and diffusion-driven transport of analytes (KCl ~0.66 nm, L-Tryptophan ~0.7–0.9 nm, Vitamin B12 ~1–1.5 nm and Lysozyme ~3.8–4 nm) to probe nanoscale and sub-nanometer scale defects. Diffusive transport confirms the presence of intrinsic sub-nanometer to nanometer scale defects in monolayer graphene grown on liquid Cu are no less than that in high-quality graphene synthesized via chemical vapor deposition (CVD) on solid Cu. Our work not only benchmarks quality of graphene grown on liquid copper for membrane applications but also provides fundamental insights into the origin of intrinsic defects in large-area graphene synthesized via bottom-up processes for membrane applications.

36 MATERIALS SCIENCE↗

Chemical and Morphological Inhomogeneity of Aluminum Metal and Oxides from Soft X-ray Spectromicroscopy

Oxygen and aluminum K-edge X-ray absorption spectroscopy (XAS), imaging from a scanning transmission X-ray microscope (STXM), and first-principles calculations were used to probe the composition and morphology of bulk aluminum metal, α- and γ-Al 2 O 3 , and several types of aluminum nanoparticles. The imaging results agreed with earlier transmission electron microscopy studies that showed a 2 to 5 nm thick layer of Al 2 O 3 on all the Al surfaces. Spectral interpretations were guided by examination of the calculated transition energies, which agreed well with the spectroscopic measurements. The features we observed in the experimental O and Al K-edge XAS were used to determine the chemical structure and phase of the Al 2 O 3 on the aluminum surfaces. For unprotected 18 and 100 nm Al nanoparticles, this analysis revealed an oxide layer that was similar to γ-Al 2 O 3 and comprised of both tetrahedral and octahedral Al coordination sites. For oleic acid-protected Al nanoparticles, only tetrahedral Al oxide coordination sites were observed. Our results were correlated to trends in the reactivity of the different materials, which suggests that the structures of different Al 2 O 3 layers have an important role in the accessibility of the underlying Al metal toward further oxidation. Combined, the Al K-edge XAS and STXM results provided detailed chemical information that was not obtained from powder X-ray diffraction or imaging from a transmission electron microscope.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectroscopic setup for submicrometer-resolution mapping of low-signal absorption and luminescence using photothermal heterodyne imaging and photon-counting techniques

A spectroscopic setup that enables one to map the absorption and photoluminescence with submicrometer spatial resolution and high sensitivity is described. Here a photothermal heterodyne imaging pump/probe technique is employed for absorption mapping, and low-signal, spatially resolved photoluminescence is recorded using photon counting. High-spatial-resolution mapping is accomplished by using high-numerical-aperture microscope objective focusing laser beams (pump and probe) into a submicrometer spot and raster-scanning sample mounted on the nanopositioning translation stage. Performance of the setup is illustrated by mapping absorption and luminescence of the hafnium oxide film with embedded hafnium nanoparticles and multilayer dielectric grating. In both cases submicrometer spatial resolution is demonstrated and possible physical mechanisms leading to image contrast on a submicrometer scale is discussed

47 OTHER INSTRUMENTATION↗

Avoided Level Crossing and Entangled States of Interacting Hydrogen Molecules Detected by the Quantum Superposition Microscope

Pump–probe measurements by ultrashort THz pulses can be used to excite and follow the coherence dynamics in the time domain of single hydrogen molecules (H 2 ) in the junction of a scanning tunneling microscope (STM). By tailoring the resonance frequency through the sample bias, we identified two spectral signatures of the interactions among multiple H 2 molecules. First, the avoided level crossing featured by energy gaps ranging from 20 to 80 GHz was observed because of the level repulsion between two H 2 molecules. Second, the tip can sense the signal of H 2 outside the junction through the projective measurement on the H 2 inside the junction, owing to the entangled states created through the interactions. A dipolar-type interaction was integrated into the tunneling two-level system model of H 2 , enabling accurate reproduction of the observed behaviors. Furthermore, our results obtained by the quantum superposition microscope reveal the intricate quantum mechanical interplay among H 2 molecules and additionally provide a 2D platform to investigate unresolved questions of amorphous materials.

36 MATERIALS SCIENCE↗

Imaging Single Atoms Using Secondary Electrons with an Aberration-Corrected Electron Microscope

Aberration correction has embarked on a new frontier in electron microscopy by overcoming the limitations of conventional round lenses, providing sub-angstrom-sized probes. However, improvement of spatial resolution using aberration correction so far has been limited to the use of transmitted electrons both in scanning and stationary mode, with an improvement of 20-40%. In contrast, advances in the spatial resolution of scanning electron microscopes (SEMs), which are by far the most widely used instrument for surface imaging at the micrometre-nanometre scale, have been stagnant, despite several recent efforts. Here, we report a new SEM, with aberration correction, able to image single atoms by detecting electrons emerging from its surface as a result of interaction with the small probe. The spatial resolution achieved represents a fourfold improvement over the best-reported resolution in any SEM. Furthermore, we can simultaneously probe the sample through its entire thickness with transmitted electrons. This ability is significant because it permits the selective visualization of bulk atoms and surface ones, beyond a traditional two-dimensional projection in transmission electron microscopy. It has the potential to revolutionize the field of microscopy and imaging, thereby opening the door to a wide range of applications, especially when combined with simultaneous nanoprobe spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of first ever scanning probe microscopy capabilities for plutonium

Scanning probe microscopy capabilities have been developed for plutonium and its derivative compounds. Specifically, a scanning tunneling microscope and an atomic force microscope housed in an ultra-high vacuum system and an inert atmosphere glove box, respectively, were prepared for the introduction of small non-dispersible δ-Pu coupons. Experimental details, procedures, and preliminary imaging of δ-Pu coupons are presented to demonstrate the functionality of these new capabilities. In conclusion, these first of a kind capabilities for plutonium represent a significant step forward in the ability to characterize and understand plutonium surfaces with high spatial resolution.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

EBSD of Rough Native CuInGaSe2 Thin-Films

The polycrystalline Cu (In, Ga) Se2, or CIGS, based thin-film materials system has long been studied for use in photovoltaic technologies, where its bandgap tunability, mechanical flexibility, and relatively low production costs are all appealing. Nonetheless, significant defect populations, which serve to reduce efficiency, create performance instabilities, and increase concerns about long-term reliability, have hindered wide-scale adoption. Prior work, including application of a scanning probe based deep level trap spectroscopy (SP-DLTS) defect mapping technique and scanning transmission electron microscope (STEM) based electron energy loss spectroscopy (EELS), has shown that the most detrimental defects, with energy level near mid-gap (thus serving as a carrier recombination center), are most likely caused by CuIn/Ga antisites and tend to cluster at or around certain grain boundaries [1,2]. However, the exact nature of these particular boundaries — their structures, chemistries, or even the relative misorientation of their associated grains — and their relation to this defect clustering and/or its formation is yet unknown. As such, electron backscatter diffraction (EBSD) orientation mapping, directly correlated with defect-sensitive techniques like SP-DLTS and/or STEM-EELS, could prove critical for providing the final missing links toward understanding the mechanisms behind these defects. Indeed, recent studies using correlative electron beam induced current (EBIC) with EBSD have been able to identify boundaries, and their relative misorientations, that possess detrimental electronic properties [3]. However, because EBIC is unable to resolve the defect energy levels, many questions are left unanswered. Furthermore, this study, and others like it, employed focused ion beam (FIB) milling to flatten the natively-rough CIGS [3-5], which may run the risk of changing the nature of any near-surface defect structures.

14 SOLAR ENERGY↗

Aerosol Composition, Mixing State, and Phase State of Free Tropospheric Particles and Their Role in Ice Cloud Formation

The prediction of ice cloud formation in the atmosphere remains challenging. Free tropospheric aerosols can act as ice nucleating particles (INPs), affecting cloud properties and precipitation. The physicochemical properties of free tropospheric particles are modified upon long-range transport by different atmospheric processes. These modifications affect the ice formation potential of individual particles. We investigated free tropospheric particles collected at the remote Pico Mountain Observatory at 2225m a.s.l. in the North Atlantic Ocean using multimodal microspectroscopy and chemical imaging techniques. We probed their ice nucleation activity using an ice nucleation stage interfaced with an environmental scanning electron microscope. Retroplume analysis, chemical imaging, and micro-spectroscopy analysis indicated that the size-resolved chemical composition, mixing state, and phase state of the articles with similar aging times but different transport patterns were substantially different. Relative humidity-dependent glass transition temperatures estimated from meteorological conditions were consistent with the observed organic component of the particles' phase. More viscous (solid and semi-solid-like) particles are more ice active in deposition mode at temperature ranging from 205-220 K than those less viscous particles. Finally, this study provides a better understanding of the phase and mixing state of long range transported free tropospheric aerosols and their role in ice cloud formation.

54 ENVIRONMENTAL SCIENCES↗

Probing the electronic structure and optical response of a graphene quantum disk supported on monolayer graphene

In this paper, we show that a graphene quantum disk (GQD) can be generated on monolayer graphene via structural modification using the electron beam. The electronic structure and local optical responses of the GQD, supported on monolayer graphene, were probed with electron energy-loss spectrum imaging on an aberration-corrected scanning transmission electron microscope. We observe that for small GQD, {approx}1.3 nm in diameter, the electronic structure and optical response are governed by the dominating edge states, and are distinctly different from either monolayer graphene or double-layer graphene. Highly localized plasmon modes are generated at the GQD due to the confinement from the edge of the GQD in all directions. The highly localized optical response from GQDs could find use in designing nanoscale optoelectronic and plasmonic devices based on monolayer graphene.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Atomic Imaging Using Secondary Electrons in a Scanning Transmission Electron Microscope: Experimental Observations and Possible Mechanisms

We report detailed investigation of high-resolution imaging using secondaryelectrons (SE) with a sub-nanometer probe in an aberration-corrected transmissionelectron microscope, Hitachi HD2700C. This instrument also allows us to acquire the corresponding annular dark-field (ADF) images both simultaneously and separately. We demonstrate that atomic SE imaging is achievable for a wide range of elements, from uranium to carbon. Using the ADF images as a reference, we studied the SE image intensity and contrast as functions of applied bias, atomic number, crystal tilt, and thickness to shed light on the origin of the unexpected ultrahigh resolution in SE imaging. We have also demonstrated that the SE signal is sensitive to the terminating species at a crystal surface. Apossiblemechanism for atomic-scale SE imaging is proposed. The ability to image both the surface and bulk of a sample at atomic-scale is unprecedented, and can have important applications in the field of electron microscopy and materials characterization.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Aberration corrected STEM by means of diffraction gratings

In the past 15 years, the advent of aberration correction technology in electron microscopy has enabled materials analysis on the atomic scale. This is made possible by precise arrangements of multipole electrodes and magnetic solenoids to compensate the aberrations inherent to any focusing element of an electron microscope. In this paper, we describe an alternative method to correct for the spherical aberration of the objective lens in scanning transmission electron microscopy (STEM) using a passive, nanofabricated diffractive optical element. This holographic device is installed in the probe forming aperture of a conventional electron microscope and can be designed to remove arbitrarily complex aberrations from the electron's wave front. In this work, we show a proof-of-principle experiment that demonstrates successful correction of the spherical aberration in STEM by means of such a grating corrector (GCOR). Our GCOR enables us to record aberration-corrected high-resolution high-angle annular dark field (HAADF-) STEM images, although yet without advancement in probe current and resolution. Finally, improvements in this technology could provide an economical solution for aberration-corrected high-resolution STEM in certain use scenarios.

47 OTHER INSTRUMENTATION↗

Integration of an Atomic Force Microscope in a Beamline Sample Environment

We developed and optimised an optics-free Atomic Force Microscope (AFM) that can be directly installed on most of the synchrotron radiation end-stations. The combination of Scanning Probe Microscopies with X-ray microbeams adds new possibilities to the variety of synchrotron radiation techniques. The instrument can be used for atomic force imaging of the investigated sample or to locally measure the X-ray absorption or diffraction, or it can also be used to mechanically interact with the sample while simultaneously taking spectroscopy or diffraction measurements. The local character of these measurements is intrinsically linked with the use of the Atomic Force Microscope tip. It is the sharpness of the tip that gives the opportunity to measure the photons flux impinging on it giving beam position monitor features, or allows to locally measure the absorption coefficient or the shape of the diffraction pattern. As an example of the possibilities opened by the instrument we will show diffraction measurements performed on a Ge/Si island while being indented with the AFM tip providing local measure of the Young coefficient. Three ESRF beamlines are going to be equipped with this new instrument.

43 PARTICLE ACCELERATORS↗

Precision controlled atomic resolution scanning transmission electron microscopy using spiral scan pathways

Atomic-resolution imaging in an aberration-corrected scanning transmission electron microscope (STEM) can enable direct correlation between atomic structure and materials functionality. The fast and precise control of the STEM probe is, however, challenging because the true beam location deviates from the assigned location depending on the properties of the deflectors. To reduce these deviations, i.e. image distortions, we use spiral scanning paths, allowing precise control of a sub-Å sized electron probe within an aberration-corrected STEM. Although spiral scanning avoids the sudden changes in the beam location (fly-back distortion) present in conventional raster scans, it is not distortion-free. “Archimedean” spirals, with a constant angular frequency within each scan, are used to determine the characteristic response at different frequencies. We then show that such characteristic functions can be used to correct image distortions present in more complicated constant linear velocity spirals, where the frequency varies within each scan. Through the combined application of constant linear velocity scanning and beam path corrections, spiral scan images are shown to exhibit less scan distortion than conventional raster scan images. The methodology presented here will be useful for in situ STEM imaging at higher temporal resolution and for imaging beam sensitive materials.

47 OTHER INSTRUMENTATION↗

All-optical evaluation of spin-orbit interaction based on diffusive spin motion in a two-dimensional electron gas

A method is presented that enables the measurement of spin-orbit coefficients in a diffusive two-dimensional electron gas without the need for processing the sample structure, applying electrical currents or resolving the spatial pattern of the spin mode. It is based on the dependence of the average electron velocity on the spatial distance between local excitation and detection of spin polarization, resulting in a variation of spin precession frequency that in an external magnetic field is linear in the spatial separation. By scanning the relative positions of the exciting and probing spots in a time-resolved Kerr rotation microscope, frequency gradients along the [100] and [010] crystal axes of GaAs/AlGaAs QWs are measured to obtain the Rashba and Dresselhaus spin-orbit coefficients, α and β. This simple method can be applied in a variety of materials with electron diffusion for evaluating spin-orbit coefficients.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interfaces in Halide Perovskites: Passivating Defects and Probing Grain Structure

In this talk we describe the role of interfaces, surface defects, and strain on non-radiative recombination losses in hybrid perovskite semiconductors. Using combinations of scanning-probe, electron backscatter diffraction (EBSD), and time-resolved photoluminescence microscopy and spectroscopy, we explore the microscopic origins of non-radiative recombination in both archetypal methylammonium lead tri-iodide (MAPI), and more advanced mixed-cation perovskites. Using EBSD, we image local grain orientation and strain, and correlate surface strain with increased non-radiative recombination in MAPI. We explore the interface between the perovskite and various common charge extraction layers, combining experiment and simulation to show that surface recombination at the charge extraction layers is a limitation in current perovskite solar cell architectures. Finally, we explore alternative passivation and extraction layers to propose ways to more routinely approach the theoretical voltage limits in perovskite photovoltaic using scalable process chemistry.

14 SOLAR ENERGY↗

The Role of Materials Degradation and Analysis in the Space Shuttle Columbia Accident Investigation

The efforts following the loss of the Space Shuttle Columbia included debris recovery, reconstruction, and analysis. The debris was subjected to myriad quantitative and semiquantitative chemical analysis techniques, ranging from examination via the scanning electron microscope (SEM) with energy dispersive spectrometer (EDS) to X-Ray diffraction (XRD) and electron probe micro-analysis (EPMA). The results from the work with the debris helped the investigators determine the location where a breach likely occurred in the leading edge of the left wing during lift off of the Orbiter from the Kennedy Space Center. Likewise, the information evidenced by the debris was also crucial in ascertaining the path of impinging plasma flow once it had breached the wing. After the Columbia Accident Investigation Board (CAIB) issued its findings, the major portion of the investigation was concluded. However, additional work remained to be done on many pieces of debris from portions of the Orbiter which were not directly related to the initial impact during ascent. This subsequent work was not only performed in the laboratory, but was also performed with portable equipment, including examination via portable X-Ray fluorescence (XRF) and Fourier transform infrared spectroscopy (FTIR). Likewise, acetate and silicon-rubber replicas of various fracture surfaces were obtained for later macroscopic and fractographic examination. This paper will detail the efforts and findings from the initial investigation, as well as present results obtained by the later examination and analysis of debris from the Orbiter including its windows, bulkhead structures, and other components which had not been examined during the primary investigation.

McDanels, Steven J.↗

Atomic-Resolution Imaging with a Sub-50-pm Electron Probe

Using a highly coherent focused electron probe in a fifth-order aberration-corrected transmission electron microscope, we report on resolving a crystal spacing less than 50 pm. Based on the geometrical source size and residual coherent and incoherent axial lens aberrations, an electron probe is calculated, which is theoretically capable of resolving an ideal 47 pm spacing with 29% contrast. Our experimental data show the 47 pm spacing of a Ge <114> crystal imaged with 11%-18% contrast at a 60%-95% confidence level, providing the first direct evidence for sub-50-pm resolution in annular dark-field scanning transmission electron microscopy imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗