NEVADA NATIONAL SECURITY SITE WASTE DISPOSAL OPERATIONS - DISPOSAL VOLUME REPORT FY 2021 - QUARTER FOUR
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Increasing use of digital technology in nuclear power plants (NPPs) poses cyber-security as a crucial threat to public safety and to continuous energy production. Cyber-security risks are comprised of complex known and unknown interactions between various entities, system vulnerabilities, network protocols, human users and malicious attacks. There is little understanding or research geared towards plant operators’ response under cyber-security threats and operational procedures to cope with such threats. This is particularly critical when a cyber-security event masquerades as a safety incident or an evolving accident. Instead of leading operators to the remediation of the accident, the masked cyber event may lead them to circumvent the safety mechanisms of the plant. Given these challenges, the objective of this project is to develop a tool to characterize abnormal NPP events as “cyber” or “safety” incidents, and to further develop this tool as a real-time operator aid to assist in response to the incident. This NEUP Final Report summarizes the research efforts towards the above goals and the results in the following three aspects. First, a methodology for classifying abnormal NPP events as cyber-attacks or safety incidents was developed. This provides the basis for responding to potential cyber-attacks. In this methodology, the causal relationships between various variables (i.e., physical variables, network variables, and control variables) for a nuclear system under consideration are modeled using dynamic Bayesian networks. Based on observations of certain variables (i.e., the evidence), inference is performed to identify the state of hidden variables, which helps indicate the occurrence of cyber-attacks or safety incidents. The proposed methodology was applied to the full scope NPP simulator system at The Ohio State University as a case study. The result shows that the proposed methodology is capable of distinguishing between cyber-attacks and safety incidents. Second, a game-theoretic approach for responding to cyber-attacks on nuclear power plants was developed. This is the second major goal of the project, and the method is used to recommend optimal responses to reactor operators in the case of cyber-attacks. We consider two cases in this research. In the first case, the interaction between the defender (i.e., the reactor operator) and the attacker is modeled as a two-player, nonzero-sum, Markov game with an infinite time horizon. In the second case, we consider a semi-Markov game between the defender and the attacker within a finite time horizon. The model in the second case enables us to consider the time sensitive response of the defender. In each case, the method for deriving the Nash equilibrium is developed. The Nash Equilibrium of the game provides the valid prediction of both players’ actions because no single player can benefit from unilaterally deviating from the equilibrium policy if the other player adheres to his/hers, hence it provides the best response of the defender to cyber-attacks. The proposed method in each case is demonstrated through a simplified benchmark digital feedwater control system. Third, a prototype display is developed to integrate the above information. The prototype display depicts the communication information to the operator and incorporates the cyber-security tool developed by the team into the interface. It consists of the regular display in current control rooms, as well as a panel used to indicate the occurrence of cyber-attacks or safety events and a panel used to guide the operator’s response to detected cyber-attacks.
Microgrids require reliable communication systems for equipment control, power delivery optimization, and operational visibility. To maintain secure communications, Microgrid Operational Technology (OT) networks must be defensible and cyber-resilient. The communication network must be carefully architected with appropriate cyber-hardening technologies to provide security defenders the data, analytics, and response capabilities to quickly mitigate malicious and accidental cyberattacks. In this work, we outline several best practices and technologies that can support microgrid operations (e.g., intrusion detection and monitoring systems, response tools, etc.). Then we apply these recommendations to the New Jersey TRANSITGRID use case to demonstrate how they would be deployed in practice.
This paper proposes a hybrid data and model-based anomaly detection scheme to secure the operation of distributed energy resources (DERs) in distribution grids. Data-driven autoencoders are set up at the edge device level and they use local DER operational data as inputs. The abnormal statuses are detected by analyzing reconstruction errors. In parallel, modelbased state estimation (SE) is set up at the central level and it uses system-wide models and measurements as data inputs. The anomalies are identified by analyzing measurement residuals. The hybrid scheme preserves the benefits of both data-driven and model-based analyses and thus improves the robustness and the accuracy of anomaly detection. Numerical tests based on the model of a real distribution feeder in Southern California highlight the proposed scheme's effectiveness and benefits.
This paper proposes a hybrid data and model-based anomaly detection for securing the operation of distributed energy resources (DERs) in distribution grids. Data-driven autoencoders (AE) are set up at the edge level by taking local DER data and detect anomalous operations by leveraging the reconstruction ability. In parallel, model-based state estimation (SE) is running at the system level by taking system models and measurements, the anomalies are identified by analyzing the measurements residual. The hybrid scheme preserves the benefits of both data-driven and model-based analysis and thus improves the robustness and accuracy of anomaly detection. It can be established by getting full use of the existing infrastructures in distribution grids. Numerical tests on a realistic distribution feeder in Southern California highlight the effectiveness as well as benefits of the proposed scheme.
This Equipment Assessment Guide, developed by Idaho National Laboratory (INL), provides a comprehensive framework designed to enhance the security of operational technology (OT) devices within power grid operations. The guide outlines essential steps for asset owners to conduct technical inspections and harden vulnerable hardware and firmware components commonly found in embedded systems. It focuses on components frequently targeted by cyber threats, offering valuable identification techniques for locating and recognizing critical components on devices. Additionally, the guide presents recommended secure configurations aimed at minimizing exposure and reinforcing defenses, along with impact analysis that highlights the potential consequences for grid operations if components are compromised. By implementing the recommendations outlined in this guide, asset owners can significantly enhance their cybersecurity posture, reduce the attack surface of field-deployed devices, and improve the resilience of grid services against emerging cyber threats.
Implementing a secure development lifecycle (SDL) presents increasing challenges to software developers as they must ensure software correctly integrates both underlying operating system security features while also managing dependencies on third-party libraries or executables. There are a growing number of security functions that require a close integration between the OS security features and software builds to ensure strong protection. Furthermore, as software platforms grow in complexity, they present many opportunities for misconfigurations and inadequate defenses. This challenge is especially prevalent for industrial control systems (ICS), which oten depend on both legacy sotware platforms, or out of date operating systems. This paper presents the AttackSurface Host Analyzer (AHA) tool, which is used to assess the security of a software platform through its integration with a host operating system. The tool collects data from the various platforms running on an OS, evaluates an array of security properties, and then introduces metrics and visualizations to provide feedback on the system's attack surface based on the external interconnections and the completeness of the available security protections. The paper then explores the attack surface of a variety of industry-standard ICS platforms to provide insight into the current degree of protection enabled by them.
The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. The Faster-than-real-time Simulation with demonstration for Resilient DER Integration project set out to do the following: a. Flatten the voltage profile through the feeders and system for cost saving and voltage stabilization needs. b. Increase the amount of intermittent distributed energy resources (IDERs) that could be deployed on a utility feeder and provide 100% or more energy needed for the demands on that feeder, and c. based on an accurate model (Digital Twin) of the utilities system, be able to detect any abnormalities on the utilities distribution system. To manage the voltage and increase IDER penetration (a,b), Graph Trace Analysis is employed in a time-series, optimal power flow to coordinate the time-varying feedback control setpoints of a distribution feeder’s utility control devices. Under the coordinated control are a Load Tap Changing Transformer, a voltage regulator, and five switched capacitor banks. The feeder serves over 2000 customers, the feeder secondaries are modeled, and the feeder has 2.3 MW of PV generation, corresponding to a 17.4% penetration of PV generation. The feeder model has over 12,000 components, where every customer load bus and PV generator are modeled. The accuracy of the power flow solution is compared against historical meter voltage measurements, the improvement in conservation voltage reduction energy savings as a function of the coordinated control desired voltage profile is investigated, and the increase in PV penetration of the coordinated control over the existing control is presented. To achieve improved control performance while observing system operation constraints, bellwether Advanced Metering Infrastructure (AMI) voltage measurements are used to adjust the desired voltage profile used by the optimal power flow analysis. To detect and alleviate or negate attacks or failures on the distribution and transmission utility grids (c) the grid needs to be resilient and self-healing. In this project software was designed to do just that. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hard-ware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.
Advancements in quantum technology, which include quantum computing, quantum sensing, quantum communications, and associated research, continue to revolutionize various fields of study by solving challenging problems deemed too difficult or more efficient than those used for classical computers. However, as these systems become ever so complex, it is critical to secure their electromagnetic operational environments and the associated impact on quantum systems and infrastructure. The goal of this synopsis is to bring attention to the susceptibility of quantum technology facilities to potential issues related to the radio frequency (RF) environment within the broader electromagnetic context. A framework is proposed for identifying, mitigating, monitoring, and auditing these often complex operational environments. By establishing best practices in the consideration and evaluation of these criteria, one can enhance the operational integrity, resilience, and security of quantum technology systems and facilities, thereby supporting their continued development and application in research and industry.