Data-Driven Load Modeling and Forecasting of Residential Appliances

The expansion of residential demand side management programs and increased deployment of controllable loads require accurate appliance-level load modeling and forecasting. This paper proposes a conditional hidden semi-Markov model to describe the probabilistic nature of residential appliance demand. Model parameters are estimated directly from power consumption data using scalable statistical learning methods. We also propose an algorithm for short-term load forecasting as a key application for appliance-level load models. Case studies performed using granular sub-metered power measurements from various types of appliances demonstrate the effectiveness of the proposed load model for short-term prediction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal Loads and Cooling Design for ITER in-Port Low Field Side Reflectometer Diagnostic System

The current design for the ITER Low Field Side Reflectometer (LFSR) diagnostic system contains six circular waveguides that function as both launch and receive antennas. The front end of LFSR system, interfacing with the plasma facing DFW and its supporting diagnostic shielding Modules (DSM), is integrated into Equatorial Port Plug 11(EPP#11). In-vessel LFSR configuration is mainly divided into two sections, i.e. Front Antenna Unit (FAU) and in-vessel Transmission Line (TL) components. During plasma normal operation, the 14 MeV neutrons from D-T fusion reactions penetrate into the port plug and LFSR components. Neutronics code ATTILA is used for assessing the volumetric heating of in-vessel components. The maximum normal heat load due to radiation and the charge exchange from plasma is 0.35 MW/m 2 , which has to be applied on those surfaces affected by a viewing factor consistent with the aperture surface position and orientation. The front antenna unit (FAU) needs the active cooling to handle the radiant and nuclear heating from the plasma. Due to the specific viewing aperture layout at the front-end of in-vessel LFSR, the cooling channel design is challenging. The thermal-hydraulic iterations are performed to achieve the desirable temperature distribution of the water cooled front antenna units. The progressive ratcheting effects of the FAU subjected to cyclic thermal loading are examined by the preliminary non-linear elastic-plastic analysis.

42 ENGINEERING↗

A MEMS dynamic mechanical analyzer for in situ viscoelastic characterization of 3D printed nanostructures

Cellular metamaterial structures with sub-micron features have shown the ability to become excellent energy absorbing materials for impact mitigation due to the enhanced mechanical properties of materials at the nanoscale. However, in order to optimize the design of these energy absorbing metamaterial structures we need to be able to measure the dynamic properties of the sub-micron features such as storage and loss moduli and the loss factor. Therefore, at scale testing is required to capture the scale, temperature, and strain rate dependent material properties of these nanoscale materials. This study presents the design, fabrication, and calibration of a MEMS-based dynamic mechanical analyzer (DMA) that can be directly integrated with the two photon lithography (TPL) process commonly used to fabricate metamaterial structures with nanoscale features. The MEMS-based DMA consists of a chevron style thermal actuator used to generate a tensile load on the structure and two differential capacitive sensors on each side of the structure used to measure load and displacement. This design demonstrated 1.5 ± 0.75 nm displacement resolution and 104 ± 52 nN load resolution, respectively. Dynamic mechanical analysis was successfully conducted on a single nanowire feature printed between the load and displacement stages of the MEMS device with testing frequencies ranging between 0.01–10 Hz and testing temperatures ranging between 22 °C–47 °C. These initial tests on an exemplar TPL part demonstrate that the printed nanowire behaves as a viscoelastic material wherein the transition from glassy to viscous behavior has already set in at the room temperature.

42 ENGINEERING↗

Factors affecting the open-circuit voltage and electrode kinetics of some iron/titanium redox flow cells

Performance of the iron-titanium redox flow cell was studied as a function of acid concentration. Anion permeable membranes separated the compartments. Electrodes were graphite cloth. Current densities ranged up to 25 mA/square centimeter. Open-circuit and load voltages decreased as the acidity was increased on the iron side as predicted. On the titanium side, open-circuit voltages decreased as the acidity was increased in agreement with theory, but load voltages increased due to decreased polarization with increasing acidity. High acidity on the titanium side coupled with low acidity on the iron side gives the best load voltage, but such cells show voltage losses as they are repeatedly cycled. Analyses show that the bulk of the voltage losses are due to diffusion of acid through the membrane.

Reid, M. A.↗

Experimental investigation of advanced turbine control strategies and load-mitigation measures with a model-scale floating offshore wind turbine system

To advance the control co-design of offshore wind energy systems, the authors perform basin-scale experiments with a fully instrumented and actuated floating offshore wind turbine model. The model consists of a 1:70 scale performance-matched model of the International Energy Agency Wind Technology Collaboration Programme 15-MW reference turbine atop the VolturnUS-S semisubmersible platform. The Reference OpenSource Controller provides real-time blade pitch and generator torque control. Here we aim to develop an open data set for the validation of numerical models in predicting the influence of turbine control and load-mitigation measures. For this purpose, we measure the effects of advanced turbine control features, including peak shaving and floating feedback as well as hull-based control using tuned mass dampers on the system. Overall, the results demonstrate measurable and consistent influences from the control and load-mitigation measures, thus confirming the usefulness as a validation data set. Peak shaving attenuates the response to wind turbulence at near-rated wind speed. Floating feedback reduces the load and platform pitch motion associated with the negative damping induced by blade pitch control. The tuned mass dampers also attenuate the system response near the targeted frequencies under suitable conditions. We also identify detrimental side effects of each load-mitigation measure.

17 WIND ENERGY↗

Demand Side Management in the Smart Grid: Information Processing for the Power Switch

In this article we discuss the most recent developments in the area of load management, and consider possible interaction schemes of novel architectures with distributed energy resources (DER). In order to handle the challenges faced by tomorrow’s smart grid, which are caused by volatile load and generation profiles (from the large number of plug-in EVs and from renewable integration), the conventional grid operating principle of load-following needs to be changed into load-shaping or generation-following. Demand Side Management will be a most promising and powerful solution to the above challenges. However, many other issues such as load forecasting, pricing structure, market policy, renewable integration interface, and even the AC/DC implementation at the distribution side, need to be taken into the design in order to search for the most effective and applicable solution.

Demand Response↗

Maximum Cs-137 Curie Loading onto Crystalline Silicotitanate for the Documented Safety Analysis of the Tank Side Cesium Removal Platform

The Tank Side Cesium Removal (TSCR) system is currently being constructed to process Hanford tank waste supernates for vitrification. TSCR incorporates a filtration system and cesium (Cs) removal system using columns filled with crystalline silicotitanate (CST) ion exchanger, produced by Honeywell UOP, LLC. The documented safety analysis (DSA) developed for TSCR limits a single column curie loading to 141,600 Ci; given a 137 Cs isotopic mass fraction of 20% and the planned CST bed size of a TSCR column, this equates to 0.10 mmole Cs per g CST. Factors that influence 137Cs loading onto the CST include, but are not limited to, CST production lot (different production lots behave differently), contact temperature, contact duration, 137Cs mass fraction, and competitors in the tank waste feed. Seventeen tank waste feeds (compositions) were identified by Washington River Protection Solutions to be processed through TSCR. These feed compositions were used to develop a simulant (referred to herein as Stage 1) that would provide an upper bound to the Cs loading onto CST based on maximizing the Cs/Na activity coefficient ratios in solution while maintaining Na at no less than 5.0 M. Building upon this Stage 1 simulant, a series of four additional simulants were developed based on the cationic/anionic species that impact Cs exchange, with each successive formulation relaxing one or more matrix component concentration constraints as show in Table S.1

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Categorizing distributed wind energy installations in the United States to inform research and stakeholder priorities

Abstract Background Distributed wind energy adoption in the United States can contribute to the diverse portfolio of energy technologies needed to achieve ambitious decarbonization goals. However, with limited deployment to date, the current distributed wind market must be better understood; these efforts will support the range of stakeholders who will drive successful deployment. This article first distinguishes three categories of distributed wind from existing literature: (1) behind the meter, (2) intended for explicit local load, and (3) physically distributed. A novel methodology to classify individual wind installations into each of these categories is then presented and applied to two data sets of wind installations in the United States to categorize and illuminate distinct segments in the distributed wind market. Results Physically distributed installations, constituted by small to moderately sized projects serving local loads on distribution systems solely because of their proximity to them, account for the highest amount of capacity but the lowest number of installations out of the three categories. The inverse is true for behind-the-meter installations, which are used to serve on-site loads. Installations intended for explicit local load, which are interconnected on the utility side of the distribution system and intentionally built to provide energy to loads on the same distribution system, rank in the middle for both installed capacity and number of installations. Conclusions Distributed wind energy deployment in the United States is geographically widespread, but the extent to which a single category is developed in each state varies. Policies, wind resources, and broad energy technology trends contribute to these deployment patterns. By identifying the extent to which each category of installations exists, decision-makers are empowered with data necessary to tailor research and development programs and address stakeholder priorities through policy and other means, ultimately supporting future deployment.

17 WIND ENERGY↗

Techno-Economic Analysis for the Addition of Thermal Energy Storage to a Campus With Existing Battery Storage

Rising global temperatures and increasing energy demands pose significant challenges for energy management, particularly in institutional and commercial settings. As cooling needs grow, campuses must balance operational efficiency, cost control, and grid stability. Energy storage solutions, such as thermal energy storage (TES) systems, offer a promising approach to shifting energy consumption from peak to off-peak periods, alleviating peak demand, reducing utility costs, and enhancing grid resilience. When integrated with existing battery energy storage systems (BESS), TES can further optimize load management and improve energy savings, especially in buildings with diverse energy needs. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills, which already operates a BESS. We assess three TES sizing strategies—full storage, load leveling, and peak demand limiting—by modeling and simulations based on historical energy loads. Our findings show that we can control TES systems to complement BESS operation, with campus-level load leveling providing the greatest cost savings by reducing peak demands. Furthermore, the study also evaluates the long-term economic viability of TES, considering installation costs, energy savings, and payback periods under varying tariffs. This research offers practical guidance for institutions seeking to enhance energy resilience and reduce operational costs through energy storage solutions.

25 ENERGY STORAGE↗

Proactive demand-side participation: Centralized versus transactive demand-Supply coordination

The active participation of demand-side flexible resources in the wholesale market price formation and load dispatch process is crucial to encouraging demand-side participation. This calls for a joint supply-demand coordination mechanism to fully take advantage of the flexible resources in distribution systems, including distributed energy resources (DERs) and responsive loads (RLs). Here this paper aims at comparing and evaluating the centralized and transactive distribution-level market coordination mechanisms. We introduce the centralized and transactive demand-supply coordination mechanisms for the distribution-level market and elaborate on the structural difference between the two frameworks. Relevant metrics and test scenarios are proposed for a meaningful comparison. The key observations of the comparative study are generalized from the perspective of different entities in the market: fixed loads, flexible loads, DERs, and conventional generators. It is observed that while the centralized approach leads to socially optimum solutions, the transactive approach by allowing for competitive bidding at the distribution-level, results in clearing higher flexible demand, and thus higher electricity cost at the transmission-level. As a result, DERs and fixed loads receive a higher surplus in the centralized approach, while conventional generators and flexible loads are more profitable in the transactive approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Load Modeling—A Review

Load modeling has significant impact on power system studies. This paper presents a review on load modeling and identification techniques. Load models can be classified into two broad categories: 1) static and 2) dynamic models, while there are two types of approaches to identify model parameters: 1) measurement-based and 2) component-based. Load modeling has received more attention in recent years because of the renewable integration, demand-side management, and smart metering devices. However, the commonly used load models are outdated, and cannot represent emerging loads. There is a need to systematically review existing load modeling techniques and suggest future research directions to meet the increasing interests from industry and academia. In this paper, we provide a thorough survey on the academic research progress and industry practices, and highlight existing issues and new trends in load modeling.

demand side↗

Knowledge graph-aided Bayesian active learning for top- K genetic interaction discovery

In silico methods for predicting the effects of multi-gene perturbations hold great promise for advancing functional genomics, computational drug discovery, and disease modeling. However, the development of these predictive algorithms for mammalian systems has been hampered by limited datasets and high experimental costs. In this study, we present a Bayesian active learning framework designed to discover pairwise host gene knockdowns that effectively inhibit viral proliferation in an in vitro HIV-1 infection model. Our method leverages a biological knowledge graph as side information and employs a computationally efficient batch diversification approach. We evaluated this framework using a dataset of viral load measurements obtained from multi-day dual-gene depletion experiments, encompassing all possible pairwise knockdowns of over 350 host genes associated with HIV infection. We demonstrate that our framework rapidly identifies the most effective gene knockdown pairs for reducing viral load. Furthermore, we show that incorporating side information enhances performance during the early stages of active learning (low data regime), while our batch diversification strategy significantly boosts performance in later stages (high data regime). This framework is general and can be adapted to explore gene interactions in other contexts, such as synthetic lethality prediction and mapping epistatic effects across quantitative trait loci.

Computational biology and bioinformatics↗

Aerodynamic Limitations of the UH-60A Rotor

High quality airloads data have been obtained on an instrumented UH-60A in flight and these data provide insight into the aerodynamic limiting behavior of the rotor. At moderate weight coefficients and high advance ratio limiting performance is largely caused by high drag near the blade tip on the advancing side of the rotor as supercritical flow develops on the rotor with moderate to strong, shocks on both surfaces of the blade. Drag divergence data from two-dimensional airfoil tests show good agreement with the development of the supercritical flow regions. Large aerodynamic pitching moments are observed at high advance ratio, as well, and these pitching moments are the source of high torsional moments on the blade and control system loads. These loads occur on the advancing side of the disk and are not related to blade stall which does not occur for these weight coefficients. At high weight coefficients aerodynamic and structural limits are related to dynamic stall cycles that begin on the retreating side of the blade and, for the most severe conditions, carry around to the advancing side of the blade at the presumed first frequency of the blade/control system.

Coleman, Colin P.↗

Design and fabrication of brazed Rene 41 honeycomb sandwich structural panels for advanced space transportation systems

The design and fabrication of two large brazed Rene 41 honeycomb panels, the establishment of a test plan, the design and fabrication of a test fixture to subject the panels to cyclic thermal gradients and mechanical loads equivalent to those imposed on an advanced space transportation vehicle during its boost and entry trajectories are discussed. The panels will be supported at four points, creating three spans. The outer spans are 45.7 cm (18 in.) and the center span 76.2 cm (30 in). Specimen width is 30.5 cm (12 in.). The panels were primarily designed by boost conditions simulated by subjecting the panels to liquid nitrogen, 77K (-320 F) on one side and 455K (360 F) on the other side and by mechanically imposing loads representing vehicle fuel pressure loads. Entry conditions were simulated by radiant heating to 1034K (1400 F). The test program subjected the panels to 500 boost thermal conditions. Results are presented.

Hepler, A. K.↗

Automated Dynamic Demand Response Implementation on a Micro-grid

In this paper, we describe a system for real-time automated Dynamic and Sustainable Demand Response with sparse data consumption prediction implemented on the University of Southern California campus microgrid. Supply side approaches to resolving energy supply-load imbalance do not work at high levels of renewable energy penetration. Dynamic Demand Response (D 2 R) is a widely used demand-side technique to dynamically adjust electricity consumption during peak load periods. Our D 2 R system consists of accurate machine learning based energy consumption forecasting models that work with sparse data coupled with fast and sustainable load curtailment optimization algorithms that provide the ability to dynamically adapt to changing supply-load imbalances in near real-time. Our Sustainable DR (SDR) algorithms attempt to distribute customer curtailment evenly across sub-intervals during a DR event and avoid expensive demand peaks during a few sub-intervals. It also ensures that each customer is penalized fairly in order to achieve the targeted curtailment. We develop near linear-time constant-factor approximation algorithms along with Polynomial Time Approximation Schemes (PTAS) for SDR curtailment that minimizes the curtailment error defined as the difference between the target and achieved curtailment values. Our SDR curtailment problem is formulated as an Integer Linear Program that optimally matches customers to curtailment strategies during a DR event while also explicitly accounting for customer strategy switching overhead as a constraint. We demonstrate the results of our D 2 R system using real data from experiments performed on the USC smartgrid and show that 1) our prediction algorithms can very accurately predict energy consumption even with noisy or missing data and 2) our curtailment algorithms deliver DR with extremely low curtailment errors in the 0.01-0.05 kWh range.

Kuppannagari, Sanmukh R.↗

Energy Options Analysis Project (Final Report)

This Bear River Band of Rohnerville Rancheria (BRB) Energy Options Analysis Project provides a rigorous and comprehensive near-term renewable energy implementation plan that aligns with the BRB’s long term strategic vision of “zero net annual utility energy consumption.” Final recommendations were arrived at by following four key project phases:A gas and electricity load assessment was conducted for all existing buildings using historic consumption data, and projected loads of new or anticipated buildings using building designs. A renewable energy resource assessment was conducted that estimated the gross generation potential of solar and wind, constrained to areas that could potentially be developed. Other renewable generation technologies were not considered feasible to meet the loads of the BRB. Demand-side efficiency and fuel switching opportunities were identified that can reduce electrical and gas consumption. These opportunities were not integrated into the load assessment in order to provide a conservative implementation plan, but are recommended to be pursued in order to cost-optimize projects during a feasibility assessment. A strategic vision advisory committee was organized and consulted when iterating on the viability of possible projects. These project phases resulted in finalizing the following three solar PV projects for the near term, which also lay the foundation for a future community-scale or multiple-facility microgrid for added resiliency. Additional solar PV on the hillside south of the Tish-Non Community Center. Solar plus battery storage microgrid at the Pump & Play fuel station. Solar PV at the Casino.

14 SOLAR ENERGY↗

Mechanism for recombination of radiation-induced point defects at interphase boundaries

MD studies of collision cascades in KS-type Cu-Nb interfaces are performed, revealing that Cu interstitials are preferentially loaded into the interface while on the bcc Nb side there is very little absorption of interstitials. The interstitial loading effect at two types of heterogeneous Cu-Nb interfaces, both KS-type and SPD {l_brace}112{r_brace}-type interfaces is studied: (a) The Cu interstitials are observed to spontaneously emit from both types of interfaces to annihilate vacancies in the nearby bulk, (b) MD and NEB studies are used to characterize low barrier emission processes. Our study also indicates that interstitials do not lose their identity when absorbed even at interfaces where they become significantly delocalized.

36 MATERIALS SCIENCE↗