Search NASA⌕ Search

SEARCH · Search NASA

Results for “size measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Investigation of spray characteristics for flashing injection of fuels containing dissolved air and superheated fuels

The flow, atomization and spreading of flashing injector flowing liquids containing dissolved gases (jet/air) as well as superheated liquids (Freon II) were considered. The use of a two stage expansion process separated by an expansion chamber, ws found to be beneficial for flashing injection particularly for dissolved gas systems. Both locally homogeneous and separated flow models provided good predictions of injector flow properties. Conventional correlations for drop sizes from pressure atomized and airblast injectors were successfully modified, using the separated flow model to prescribe injector exit conditions, to correlate drop size measurements. Additional experimental results are provided for spray angle and combustion properties of sprays from flashing injectors.

Solomon, A. S. P.↗

Atomization and combustion properties of flashing injectors

Flashing injection involves expanding a fluid through an injector until a supersaturated state is reached, causing a portion of the fluid to flash to a vapor. This investigation considered the flow, atomization and spreading properties of flashing injectors flowing liquids containing dissolved gases (Jet A/air) as well as superheated liquids (Freon 11). The use of a two stage expansion process, separated by an expansion chamber, was found to be beneficial for good atomization properties of flashing injection - particularly for dissolved gas systems. Both locally homogeneous and separated flow models provided good predictions of injector flow properties. Conventional correlations for drop sizes from pressure atomized and airblast injectors were successfully modified, using the separated flow model to prescribe injector exit conditions, to correlate drop size measurements. Additional experimental results are provided for spray angle and combustion properties of sprays from flashing injectors.

Solomon, A. S. P.↗

Detection of sulphur in the galactic center

A strong detection at the (SIII) 18.71 micron line is reported for the Galactic Center region, Sgr A West. A line flux of 1.7 + or - 0.2x10 to the -17th power W cm(-2) is found for a 20-arc second beam-size measurement centered on IRS 1. A preliminary analysis indicates that the SIII abundance relative to hydrogen is consistent with the cosmic abundance of sulfur, 1.6x10 to the -5th power, if a filling factor of unity within the known clumps is assumed. However, the sulfur abundance in the Galactic Center may be as much as a factor of 3 overabundant if a filling factor of 0.03 is adopted, a value found to hold for some galactic HII regions.

Herter, T.↗

Detection of sulfur in the galactic center

A strong detection at the S III forbidden 18.71 micron line is reported for the galactic center region, Sgr A West. A line flux of 1.7 + or - 0.2 x 10 to the -17th W/sq cm is found for a 20 inch beam size measurement centered on IRS 1. A preliminary analysis indicates that the S III abundance relative to hydrogen is consistent with the cosmic abundance of sulfur, 0.000016, if a filling factor of unity within the known clumps is assumed. However, the sulfur abundance in the galactic center may be as much as a factor of 3 overabundant if a filling factor of 0.03 is adopted, a value found to hold for some galactic H II regions.

Herter, T.↗

Deposition of Na2SO4 from salt-seeded combustion gases of a high velocity burner rig

The mechanism of deposition of Na2SO4 was studied under controlled laboratory conditions and the results have been compared to a recently developed comprehensive theory of vapor deposition. Thus Na2SO4, NaCl, NaNO3 and simulated sea salt solutions were injected into the combustor of a nominal Mach 0.3 burner rig burning jet fuel at constant fuel/air ratios. The deposits formed on inert collectors, rotation in the cross flow of the combustion gases, were weighed and analyzed. Collector temperature was uniform and could be varied over a large range by internal air cooling. Deposition rates and dew point temperatures were determined. Supplemental testing included droplet size measurements of the atomized salt solutions. These tests along with thermodynamic and transport calculations were utilized in the interpretation of the deposition results.

Santoro, G. J.↗

Development of a global model for atmospheric backscatter at CO2 wavelengths

Work on the following tasks is reported briefly: (1) to investigate the effect of aerosol microphysical processes, occurring in an aerosol plume which undergoes transport in the atmosphere, on its beta sub CO2 value and (2) to examine experimentally measured size distributions for the free troposphere, fit bimodal log-normal models with different retractive indices for the two modes, and calculate beta sub CO2.

Source record↗

Flow and atomization in flashing injectors

Flashing injection involves expanding a fluid through an injector until a supersaturated state is reached, causing a portion of the fluid to flash to a vapor. This investigation considered the flow, atomization and spreading properties of flashing injectors with flowing liquids containing dissolved gases (Jet A/air) as well as superheated liquids (Freon-11). The use of a two-stage expansion process, separated by an expansion chamber, was found to be beneficial for good atomization properties of flashing injection - particularly for dissolved gas systems. Both locally homogeneous and separated flow models provided good predictions of injector flow properties. Conventional correlations for drop sizes from pressure and airblast injectors were successfully modified, using the separated flow model to prescribe injector exit conditions, and to correlate drop size measurements. Additional experimental results are provided for spray angles of sprays from flashing injectors.

Solomon, A. S. P.↗

Effect of mass-velocity on liquid jet atomization in Mach 1 gasflow

Interacting two-phase flow in four differently sized pneumatic two-fluid atomizers was investigated to determine the effect of gas mass-velocity on the Sauter mean diameter of sprays produced by small diameter liquid jets breaking up in high velocity gas flow. Tests were conducted primarily in the acceleration-wave regime for liquid jet atomization, where it was found that the loss of droplets due to vaporization had a marked effect on drop size measurements. A scattered-light scanner, developed at NASA Lewis Research Center, was used to measure the Sauter mean diameter, D sub 32, which was correlated with nitrogen gas mass-velocity to give the following expression: D (sup -1)(sub 32) = 11.7(rho (sub n) V (sub n)) (sup 1.33). The exponent 1.33 for the gas mass-velocity is identical to that predicted by atomization theory for liquid jet breakup in the acceleration-wave regime.

Ingebo, Robert D.↗

Rocket engine injection element characterization

Characterization of liquid rocket engine injection elements is an important part of the development process for rocket engine combustion devices. Modern nonintrusive instrumentation for flow velocity and spray droplet size measurement and automated, computer-controlled test facilities allow rapid, low-cost evaluation of injection element performance and behavior. Application of these methods in rocket engine development, paralleling their use in gas turbine engine development, will reduce rocket engine development cost and risk. Two types of liquid rocket engine injection elements have been characterized using such methods.

Cox, George B., Jr.↗

Dehydration in the lower Antarctic stratosphere in late winter and spring

The history of minimum temperatures at 50 and 70 mb is examined from NMC, UK Met 0 and ECMWF analyses. MSU channel 24 data are similarly inspected. South Pole sonde data are used to calculate saturation humidity mixing ratio as a function of altitude and time throughout 1987. Saturation with respect to ice could be maintained for water mixing ratios of 3.5 ppmv for a period of about 80 days from mid-June to mid-September. Dehydration to mixing ratios of 1 ppmv or less was possible sporadically. Data from the ER-2 flights between 53 S and 72 S are used in conjunction with particle size measurements and air parcel trajectories to demonstrate the dehydration occurring over Antarctica. Water mixing ratios at the latitude of Punta Arenas (53 S), in conjunction with tracer measurements and trajectory analysis, show that at potential temperatures from about 325 to 400 K, the dryness (less than 3 ppmv) had its origin over Antarctica rather than in the tropics. Water mixing ratios within the Antarctic vortex varied from 1.5 to 3.8 ppmv, with a strong isentropic gradient being evident in the region of high potential vorticity gradients.

Kelly, K. K.↗

Interior characteristics at mid-levels of thunderstorms in the southeastern United States

Data characterizing the vertical wind structure and hydrometeors within cumulonimbus clouds in the southeastern United States were collected by the armored T-28 aircraft during the 1986 Cooperative Huntsville Meteorological Experiment (COHMEX). Data analysis concentrated on the hydrometeor character and development, as well as the general microphysical and kinematic structure of the clouds penetrated. The high reflectivities which sometimes exceeded the usual 55 dBz limit set for the T-28, are not necessarily related to hail in the COHMEX storms. Instead, large numbers of millimeter-size particles were found, while the hail infrequently encountered was generally small. The fact that the larger hydrometeors were usually found in narrow and weak updrafts that appeared to be well mixed suggests that a coalescence mechanism was active in many of the storms. The depth of warm cloud (typically about 3.5 km) present in these storms apparently allows ample time for particles to reach the observed millimeter sizes. The presence of cloud droplets in the largest sizes measured supports this mechanism. Ice processes play a role in the precipitation, but hail was unable to grow very large in these storms probably because the high concentrations of observed growth centers suggest a natural beneficial competition process.

Musil, Dennis J.↗

Dehydration in the lower Antarctic stratosphere during late winter and early spring, 1987

The history of minimum temperatures at 50 and 70 mb is examined from NMC, UK Met O and ECMWF analyses. MSU channel 24 data are similarly inspected. South Pole sonde data are used to calculate saturation humidity mixing ratio as a function of altitude and time throughout 1987. Saturation with respect to ice could be maintained for water mixing ratios of 3.5 ppmv for a period of about 80 days from mid-June to mid-September. Dehydration to mixing ratios of 1 ppmv or less was possible sporadically. Data from the ER-2 flights between 53 S and 72 S are used in conjunction with particle size measurements and air parcel trajectories to demonstrate the dehydration occurring over Antarctica. Water mixing ratios at the latitude of Punta Arens (53 S), in conjunction with tracer measurements and trajectory analysis, show that at potential temperatures from about 325 to 400 K, the dryness (less than 3 ppmv) had its origin over Antarctica rather than in the tropics. Water mixing ratios within the Antarctic vortex varied from 1.5 to 3.8 ppmv, with a strong isentropic gradient being evident in the region of high potential vorticity gradients.

Kelly, K. K.↗

Injector element characterization methodology

Characterization of liquid rocket engine injector elements is an important part of the development process for rocket engine combustion devices. Modern nonintrusive instrumentation for flow velocity and spray droplet size measurement, and automated, computer-controlled test facilities allow rapid, low-cost evaluation of injector element performance and behavior. Application of these methods in rocket engine development, paralleling their use in gas turbine engine development, will reduce rocket engine development cost and risk. The Alternate Turbopump (ATP) Hot Gas Systems (HGS) preburner injector elements were characterized using such methods, and the methodology and some of the results obtained will be shown.

Cox, George B., Jr.↗

Assembly, alignment, and cold focus test methods utilized on CLAES optics

This paper describes the techniques and the equipment used in the assembly and alignment of the Cryogenic Limb Array Etalon Spectrophotometer (CLAES) Telescope and Spectrometer, together with those used to test the system at operating temperatures in order to establish the correct focus for the detector array and other system components. In addition, cryogenic tests were used to determine the stability of the optics over the specified environment, and blur size measurements were performed at operational temperatures.

Dawson, Juan C.↗

Evaluation of the Fracture Toughness of Nb-40Al-8Cr-1W-1Y-0.05B Intermetallic Material by Indentation Techniques

The fracture toughness of an Nb-40Al-8Cr - 1W-1Y-0.05B intermetallic material was evaluated by indentation techniques at room temperature. Two widely used indentation methods, crack size measurement and indent strength, yielded excellent agreement with a conventional fracture toughness technique using straight-through precracked specimens, despite the occasional formation of poorly configured cracks. However, the modified indentation technique, using dummy indent flaws, resulted in a low fracture toughness compared to that evaluated by the other methods. The material did not exhibit rising R-curve behavior, as evaluated from the indentation strength data. These results indicate that indentation fracture principles are applicable to this brittle intermetallic material without modification of the residual contact stress term originally calibrated for ceramic materials.

Choi, S. R.↗

Characteristics of surface roughness associated with leading edge ice accretion

Detailed size measurements of surface roughness associated with leading edge ice accretions are presented to provide information on characteristics of roughness and trends of roughness development with various icing parameters. Data was obtained from icing tests conducted in the Icing Research Tunnel (IRT) at NASA Lewis Research Center (LeRC) using a NACA 0012 airfoil. Measurements include diameters, heights, and spacing of roughness elements along with chordwise icing limits. Results confirm the existence of smooth and rough ice zones and that the boundary between the two zones (surface roughness transition region) moves upstream towards stagnation region with time. The height of roughness grows as the air temperature and the liquid water content increase, however, the airspeed has little effect on the roughness height. Results also show that the roughness in the surface roughness transition region grows during a very early stage of accretion but reaches a critical height and then remains fairly constant. Results also indicate that a uniformly distributed roughness model is only valid at a very initial stage of the ice accretion process.

Shin, Jaiwon↗

Airport surveillance using a solid state coherent lidar

The utility of solid state coherent LIDAR was assessed in the following application areas: (1) wake vortices; (2) dry and wet microburst windshear; (3) gusts; (4) vertical and general wind profiling; and (5) cloud ceiling. The system performance model described was based on a concept definition, system sizing, measurement planning, and algorithm and graphics display development. Data were collected at the Kennedy Space Center and the National Weather Service site adjacent to Denver's Stapleton Airport.

Huffaker, R. Milton↗

Flocculation and aggregation in a microgravity environment (FAME)

An experiment to study flocculation phenomena in the constrained microgravity environment of a space shuttle or space station is described. The small size and light weight experiment easily fits in a Spacelab Glovebox. Using an integrated fiber optic dynamic light scattering (DLS) system we obtain high precision particle size measurements from dispersions of colloidal particles within seconds, needs no onboard optical alignment, no index matching fluid, and offers sample mixing and shear melting capabilities to study aggregation (flocculation and coagulation) phenomena under both quiescent and controlled agitation conditions. The experimental system can easily be adapted for other microgravity experiments requiring the use of DLS. Preliminary results of ground-based study are reported.

Ansari, Rafat R.↗