Search NASA⌕ Search

SEARCH · Search NASA

Results for “snapping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Automation of the Mark 3 field system

The software and hardware components which will enable hands off operation are described. The operation of the field system begins with the scheduling of observations. An interactive program, SKED, provides displays of mutual visibility, automatic calculation of telescope slewing times, and the ability to list and edit the schedule. The output of SKED is a schedule file containing commands in the Standard Notation for Astronomy Procedures (SNAP) language which the field system uses for controlling events during the experiment. The most important features of SNAP include sophisticated time sequencing of events, automatic logging of all commands and responses, and the ability to define often used sequences of commands as procedures. A control program, BOSS, running in an HP 1000 minicomputer, reads the SNAP commands from a schedule file and interprets them in terms of commands and requests to devices. Interactive command input is possible through the operator's display terminal. Communication with all of the Mark 3 electronics modules is done via a small general purpose interface board (a microprocessor based ASCII transceiver) which has been installed in each module. Additional devices are controlled and monitored using the IEEE 488 General Purpose Interface Bus.

Vandenbere, N. R.↗

Anomalous Oxygen and Krypton Abundances in Interstellar Gas

The primary objective of this program was to obtain FUSE observations of the interstellar H2 absorption toward a sample of stars observed with the HST STIS spectrograph as part of the ISM SNAP Survey. This Survey was designed to produce a database of high quality, high resolution W spectra from which interstellar gas-phase elemental abundances could be derived for large portions of the Galaxy. In particular, oxygen and krypton were chosen as excellent tracers for measuring the homogeneity of the interstellar gas due to their weak depletion into dust grains. The gas-phase 0 and Kr abundances relative to total hydrogen column density had previously been shown with HST GHRS measurements to be essentially constant in the local Milky Way. One of the main motivations of the ISM SNAP Survey was to determine if this constancy held at greater distances and in denser sightlines (where depletion into dust could be a possibility). The initial ISM SNAP STIS observations indicated a number of sightlines with unusual 0 and Kr abundances relative to the measured H I column densities. Since the appropriate benchmark for accurate abundance comparisons is the total hydrogen column density (H I plus H2), FUSE observations of interstellar H2 were carried out in these sightlines in order to determine if they represent cases of true abundance anomalies.

Meyer, David M.↗

Nitric oxide donors, sodium nitroprusside and S-nitroso-N-acetylpencillamine, stimulate myoblast proliferation in vitro

Nitric oxide (NO) is an inter- and intracellular messenger involved in a variety of physiologic and pathophysiologic conditions. The effect of two NO donors, sodium nitroprusside (SNP) and S-nitroso-N-acetylpenicillamine (SNAP) and their effect on myoblast proliferation was examined. Both donors stimulated an increase in myoblast cell number over a range (1-10 microM) of donor concentrations. However, 50 microM SNAP inhibited myoblast proliferation. Cell numbers from cultures treated with degraded 10 microM SNAP were equivalent to the control. Therefore, it appears NO can stimulate as well as inhibit myoblast proliferation.

Non-NASA Center↗

EVA Swab Tool to Support Planetary Protection and Astrobiology Evaluations

When we send humans to search for life on other planets, we'll need to know what we brought with us versus what may already be there. To ensure our crewed systems meet planetary protection requirements-and to protect our science from human contamination-we'll need to assess whether microorganisms may be leaking or venting from our spacecraft. Microbial sample collection outside of a pressurized spacecraft is complicated by temperature extremes, low pressures that preclude the use of laboratory standard (wetted) swabs, and operation either in bulky spacesuits or with robotic assistance. Engineers at the National Aeronautics and Space Administration (NASA) recently developed a swab kit for use in collecting microbial samples from the external surfaces of crewed spacecraft, including spacesuits. The Extravehicular Activity (EVA) Swab Kit consists of a single swab tool handle and an eight-canister sample caddy. The design team minimized development cost by re-purposing a heritage Space Shuttle tile repair handle that was designed to quickly snap into different tool attachments by engaging a mating device in each attachment. This allowed the tool handle to snap onto a fresh swab attachment much like popular shaving razor handles can snap onto a disposable blade cartridge. To disengage the handle from a swab, the user performs two independent functions, which can be done with a single hand. This dual operation mitigates the risk that a swab will be inadvertently released and lost in microgravity. Each swab attachment is fitted with commercially available foam swab tips, vendor-certified to be sterile for Deoxyribonucleic Acid (DNA). A microbial filter installed in the bottom of each sample container allows the container to outgas and repressurize without introducing microbial contaminants to internal void spaces. Extensive ground testing, post-test handling, and sample analysis confirmed the design is able to maintain sterile conditions as the canister moves between various pressure environments. To further minimize cost, the design team acquired extensive ground test experience in a relevant flight environment by piggy-backing onto suited crew training runs. These training runs allowed the project to validate tool interfaces with pressurized EVA gloves and collect user feedback on the tool design and function, as well as characterize baseline microbial data for different types of spacesuits. In general, test subjects found the EVA Swab Kit relatively straightforward to operate, but identified a number of design improvements that will be incorporated into the final design. Although originally intended to help characterize human forward contaminants, this tool has other potential applications, such as for collecting and preserving space-exposed materials to support astrobiology experiments.

Rucker, Michelle A.↗

EVA Swab Tool to Support Planetary Protection and Astrobiology Evaluations

When we send humans to search for life on other planets, we'll need to know what we brought with us versus what may already be there. To ensure our crewed systems meet planetary protection requirements-and to protect our science from human contamination-we'll need to assess whether microorganisms may be leaking or venting from our spacecraft. Microbial sample collection outside of a pressurized spacecraft is complicated by temperature extremes, low pressures that preclude the use of laboratory standard (wetted) swabs, and operation either in bulky spacesuits or with robotic assistance. A team at the National Aeronautics and Space Administration (NASA) recently developed a swab kit for use in collecting microbial samples from the external surfaces of crewed spacecraft, including spacesuits. The Extravehicular Activity (EVA) Swab Kit consists of a single swab tool handle and an eight-canister sample caddy. The design team minimized development cost by re-purposing a heritage Space Shuttle tile repair handle that was designed to quickly snap into different tool attachments by engaging a mating device in each end effector. This allowed the tool handle to snap onto a fresh swab end effector much like popular shaving razor handles can snap onto a disposable blade cartridge. To disengage the handle from a swab, the user performs two independent functions, which can be done with a single hand. This dual operation mitigates the risk that a swab will be inadvertently released and lost in microgravity. Each swab end effector is fitted with commercially available foam swab tips, vendor-certified to be sterile for Deoxyribonucleic Acid (DNA). A microbial filter installed in the bottom of each sample container allows the container to outgas and re-pressurize without introducing microbial contaminants to internal void spaces. Extensive ground testing, post-test handling, and sample analysis confirmed the design is able to maintain sterile conditions as the canister moves between various pressure environments. To further minimize cost, the design team acquired extensive ground test experience in a relevant flight environment by piggy-backing onto suited crew training runs. These training runs allowed the project to validate tool interfaces with pressurized EVA gloves and collect user feedback on the tool design and function, as well as characterize baseline microbial data for different types of spacesuits. In general, test subjects found the EVA Swab Kit relatively straightforward to operate, but identified a number of design improvements that will be incorporated into the final design. Although originally intended to help characterize human forward contaminants, this tool has other potential applications, such as for collecting and preserving space-exposed materials to support astrobiology experiments.

Rucker, Michelle A.↗

EVA Swab Tool to Support Planetary Protection and Astrobiology Evaluations

When we send humans to search for life on other planets, we'll need to know what we brought with us versus what may already be there. To ensure our crewed systems meet planetary protection requirements?and to protect our science from human contamination?we'll need to assess whether microorganisms may be leaking or venting from our spacecraft. Microbial sample collection outside of a pressurized spacecraft is complicated by temperature extremes, low pressures that preclude the use of laboratory standard (wetted) swabs, and operation either in bulky spacesuits or with robotic assistance. A team at the National Aeronautics and Space Administration (NASA) recently developed a swab kit for use in collecting microbial samples from the external surfaces of crewed spacecraft, including spacesuits. The Extravehicular Activity (EVA) Swab Kit consists of a single swab tool handle and an eight-canister sample caddy. The design team minimized development cost by re-purposing a heritage Space Shuttle tile repair handle that was designed to quickly snap into different tool attachments by engaging a mating device in each end effector. This allowed the tool handle to snap onto a fresh swab end effector much like popular shaving razor handles can snap onto a disposable blade cartridge. To disengage the handle from a swab, the user performs two independent functions, which can be done with a single hand. This dual operation mitigates the risk that a swab will be inadvertently released and lost in microgravity. Each swab end effector is fitted with commercially available foam swab tips, vendor-certified to be sterile for Deoxyribonucleic Acid (DNA). A microbial filter installed in the bottom of each sample container allows the container to outgas and re-pressurize without introducing microbial contaminants to internal void spaces. Extensive ground testing, post-test handling, and sample analysis confirmed the design is able to maintain sterile conditions as the canister moves between various pressure environments. To further minimize cost, the design team acquired extensive ground test experience in a relevant flight environment by piggy-backing onto suited crew training runs. These training runs allowed the project to validate tool interfaces with pressurized EVA gloves and collect user feedback on the tool design and function, as well as characterize baseline microbial data for different types of spacesuits. In general, test subjects found the EVA Swab Kit relatively straightforward to operate, but identified a number of design improvements that will be incorporated into the final design. Although originally intended to help characterize human forward contaminants, this tool has other potential applications, such as for collecting and preserving space-exposed materials to support astrobiology experiments.

planetary protection↗

Qudit Gate Decomposition Dependence for Lattice Gauge Theories

In this work, we investigate the effect of decomposition basis on primitive qudit gates on superconducting radio-frequency cavity-based quantum computers with applications to lattice gauge theory. Three approaches are tested: SNAP & Displacement gates, ECD & single-qubit rotations $R(\theta,\phi)$, and optimal pulse control. For all three decompositions, implementing the necessary sequence of rotations concurrently rather then sequentially can reduce the primitive gate run time. The number of blocks required for the faster ECD &$R_p(\theta)$ is found to scale $\mathcal{O}(d^2)$, while slower SNAP & Displacement set scales at worst $\mathcal{O}(d)$. For qudits with $d<10$, the resulting gate times for the decompositions is similar, but strongly-dependent on experimental design choices. Optimal control can outperforms both decompositions for small $d$ by a factor of 2-12 at the cost of higher classical resources. Lastly, we find that SNAP & Displacement are slightly more robust to a simplified noise model.

Kürkçüoglu, Doga Murat↗

Generalizable machine learning potentials for quantum-accurate predictions of non-equilibrium behavior in 2D materials

Machine learning interatomic potentials (ML-IAPs) are emerging as transformative tools in materials modeling, promising quantum-level accuracy at a fraction of the computational cost. However, their ability to generalize beyond equilibrium configurations and to reliably capture defect- and temperature-driven behavior remains underexplored. Here, we develop and benchmark two state-of-the-art ML-IAPs, Spectral Neighbor Analysis Potential (SNAP) and Allegro, on a comprehensive dataset for monolayer MoSe₂. Using density functional theory (DFT) as the reference, we evaluate their performance in capturing stress–strain behavior, phase transition energetics, defect evolution, edge stability, and fracture toughness. Allegro, a deep equivariant neural network potential, surpasses both SNAP and the classical Tersoff potential in accuracy, efficiency, and transferability. Importantly, both ML potentials accurately reproduce experimental fracture measurements and ab initio predictions of inversion domain formation—phenomena well beyond their training sets. Our findings establish ML-IAPs as viable replacements for traditional force fields in the study of non-equilibrium mechanical phenomena, enabling large-scale, high-fidelity simulations in 2D materials and beyond. In conclusion, this work provides a broadly applicable framework for data-driven modeling of structural and functional transformations under extreme conditions.

2D materials↗

SNAPRed: Reduction of multidimensional neutron time-of-flight diffraction data

SNAP is a neutron time-of-flight diffractometer at the Spallation Neutron Source operated by Oak Ridge National Laboratory. It generates large arrays of neutron detection events that encode the crystalline atomic structure of materials under study. SNAPRed is an application that makes these datasets accessible to end users by orchestrating the process of data reduction while automatically managing the variable neutron instrumentation configuration. It supports arbitrary grouping and masking of individual detector pixels and includes custom-developed data compression approaches to accommodate the large volumes of data generated by the SNAP instrument.

Diffraction↗

Multidimensional Rietveld refinement of high-pressure neutron diffraction data of PbNCN

High-pressure neutron powder diffraction data from PbNCN were collected on the high-pressure diffraction beamline SNAP located at the Spallation Neutron Source (SNS) of Oak Ridge National Laboratory (Tennessee, USA). The diffraction data were analyzed using the novel method of multidimensional (two dimensions for now, potentially more in the future) Rietveld refinement and, for comparison, employing the conventional Rietveld method. To achieve two-dimensional analysis, a detailed description of the SNAP instrument characteristics was created, serving as an instrument parameter file, and then yielding both cell and spatial parameters as refined under pressure for the first time for solid-state cyanamides/carbodiimides. The bulk modulus B 0 = 25.1 (15) GPa and its derivative B ′ 0 = 11.1 (8) were extracted for PbNCN following the Vinet equation of state. Surprisingly, an internal transition was observed beyond 2.0 (2) GPa, resulting from switching the bond multiplicities (and bending direction) of the NCN 2− complex anion. The results were corroborated using electronic structure calculation from first principles, highlighting both local structural and chemical bonding details.

Meinerzhagen, Yannick↗

A finite element procedure for nonlinear prebuckling and initial postbuckling analysis

A procedure cast in a form appropriate to the finite element method is presented for geometrically nonlinear prebuckling and postbuckling structural analysis, including the identification of snap-through type of buckling. The principal features of this procedure are the use of direct iteration for solution of the nonlinear algebraic equations in the prebuckling range, an interpolation scheme for determination of the initial bifurcation point, a perturbation method in definition of the load-displacement behavior through the postbuckling regime, and extrapolation in determination of the limit point for snap-through buckling. Three numerical examples are presented in illustration of the procedure and in comparison with alternative approaches.

Mau, S. T.↗

Retaining a sleeve on a shaft

Snap ring with slotted tabs fits groove in shaft. Sleeve to be held on shaft fits over snap ring keeping it from expanding. Tabs are bent out to keep sleeve from slipping off shaft.

Pessin, R.↗

A new asymptotic method for jump phenomena

Physical phenomena involving rapid and sudden transitions, such as snap buckling of elastic shells, explosions, and earthquakes, are characterized mathematically as a small disturbance causing a large-amplitude response. Because of this, standard asymptotic and perturbation methods are ill-suited to these problems. In the present paper, a new method of analyzing jump phenomena is proposed. The principal feature of the method is the representation of the response in terms of rational functions. For illustration, the method is applied to the snap buckling of an elastic arch and to a simple combustion problem.

Reiss, E. L.↗

Characterization of silicon-gate CMOS/SOS integrated circuits processed with ion implantation

The procedure used to generate MEBES masks and produce test wafers from the 10X Mann 1600 Pattern Generator Tape using existing CAD utility programs and the MEBES machine in the RCA Solid State Technology Center are described. The test vehicle used is the MSFC-designed SC102 Solar House Timing Circuit. When transforming the Mann 1600 tapes into MEBES tapes, extreme care is required in order to obtain accurate minimum linewidths when working with two different coding systems because the minimum grid sizes may be different for the two systems. The minimum grid sizes are 0.025 mil for MSFC Mann 1600 and 0.02 mil for MEBES. Some snapping to the next grid is therefore inevitable, and the results of this snapping effect are significant when submicron lines are present. However, no problem was noticed in the SC102 circuit because its minimum linewidth is 0.3 mil (7.6 microns). MEBES masks were fabricated and wafers were processed using the silicon-gate CMOS/SOS and aluminum-gate COS/MOS processing.

Woo, D. S.↗

Nonlinear effects of elastic coupling in unsymmetric laminates

Classical lamination theory predicts the room-temperature shape of all unsymmetrically laminated, elevated-temperature cure composites to be a saddle shape. Experimental observation indicates, however, that in many cases the room-temperature shape is cylindrical. In addition, a second cylindrical shape can often be obtained from the first by a simple snap-through action. It is the elastic couplings between inplane and out-of-plane deformations which are inherent in unsymmetric laminates that are responsible for the room-temperature shape. However, the couplings are so strong that geometrically nonlinear effects are produced. These are not accounted for in the classical theory. This paper reviews a theory developed to explain the effects of the coupling on laminate shape. The theory is based on a minimization of the laminate's total potential energy. The theory accounts for geometric nonlinearities. Because the problem is nonlinear, approximate solutions are sought by using a Rayleigh-Ritz procedure. Because of the observed snap-through of some laminates, stability of the predicted shapes is examined. Numerical results and some limited experimental data are presented for several laminates.

Hyer, M. W.↗

Quick-Change Anode for Plating

Proposed fastener for attaching electroplating anode improves quality of plating and increases productivity. Notches in twist-lock fastener mates with projections on end of anode bar. Fastener made of titanium for compatibility with copper-plating solution. Also constructed in snap-on, snap-off configuration.

Beasley, J. L.↗