Search NASA⌕ Search

SEARCH · Search NASA

Results for “soaking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Early development of ceramic fiber insulation for the Space Shuttle

The evolution of reusable surface insulation is described, with attention to the mullite and other aluminosilicates, zirconia, and silicon carbide-coated carbon compositions experimented with in the late 1960s and early 1970s. Evaluation and development concentrated in this period on such aspects of design and material properties as cold soak performance, attachment, shock impingement, surface coating cracks, and tile gap design and heating. In addressing the central problem of heat-shield thermal conductivity, it was found that for a given density, silica fibers had a lower conductivity than those of mullite. This was due to the one-micron, as opposed to 4.7-micron, diameter of the silica fibers, which resulted in smaller pores and therefore less convective and radiative heat transfer. Attention is also given to tile coating materials and the high-temperature processes by which they were applied.

Buckley, J. D.↗

Gasification of carbon fiber composites for the alleviation of electrical hazards

A mixture of calcium acetate and lithium acetate applied to the surface of carbon fibers caused the fibers to gasify in a simulated airplane-crash fire. Tests conducted with a JPL-developed electrical detector showed the catalyst-modified composites to release few fibers during burning, while state-of-the-art composites released several hundred. Mechanical property tests demonstrated nearly identical behavior of catalyst-modified and state-of-the-art composites. Aging tests also showed little difference in the composite strength except for a severe reduction when soaked in water. Several promising new concepts resulted from the project, including catalytic elimination of carbon particulates from diesel exhaust, catalytic improvement of coal combustion, and electrical destruction of carbon particulates in combustion systems.

Hull, G.↗

Further developments in the design and analysis of adhesive-bonded structural joints

Previously developed computer programs for analyzing stepped-lap adhesive-bonded joints and doublers have been modified to permit the inclusion of variable adhesives as well as nonuniform adherends. The new version of the analysis program is described with reference to examples illustrating the effects of load redistribution around flaws and porosity. The loss of strength associated with pinched-off edges is illustrated, and the benefits of deliberately thickening the adhesive layer in the immediate vicinity of the ends of the overlap are demonstrated. The changes in shear load transfer due to softening of some of the adhesive by moisture absorption while the remainder either has never been soaked or has dried out locally are discussed.

Hart-Smith, L. J.↗

Comparison of visualized turbine endwall secondary flows and measured heat transfer patterns

Various flow visualization techniques were used to define the secondary flows near the endwall in a large heat transfer data. A comparison of the visualized flow patterns and the measured Stanton number distribution was made for cases where the inlet Reynolds number and exit Mach number were matched. Flows were visualized by using neutrally buoyant helium-filled soap bubbles, by using smoke from oil soaked cigars, and by a few techniques using permanent marker pen ink dots and synthetic wintergreen oil. Details of the horseshoe vortex and secondary flows can be directly compared with heat transfer distribution. Near the cascade entrance there is an obvious correlation between the two sets of data, but well into the passage the effect of secondary flow is not as obvious.

Gaugler, R. E.↗

Topological reaction rate measurements related to scoffing

A ball-on-plate (both consisting of hardened M-50 steel) sliding elastohydrodynamic contact was run with trimethylolpropane triheptanoate (TMPTH) with and without tricresyl phosphate (TCP). The contact area of the plate was optically profiled with a phase-locked interference microscope (PLIM) both before and after exposure to alcoholic hydrochloric acid. As scuffing was approached, the profile within the contact region changed more rapidly after the acid treatment; after scuffing, it assumed a constant high value. A metallurgical phase found in the scuff mark was apparently responsible for the high reactivity. The microscopic profile changes (sensitivity, + or - 3 nm (+ or - A) in depth) involved primarily the small asperities (radius, 3 microns); the larger ones were unaffected. Soaking the steel in TCP smoothed the fine structure of the surface profile but increased its reactivity toward alcoholic hydrochloric acid before sliding was started. Thus it would appear that PLIM examination could be used for screening potentially scuff-resistant materials.

Lauer, J. L.↗

Flight test of a synthetic aperture radar antenna using STEP

To establish confidence in its overall performance, credible information on the synthetic aperture radar antenna's mechanical properties in orbit must be obtained. However, the antenna's size, design, and operating environment make it difficult to simulate operating conditions under 1-g Earth conditions. The Space Technology Experiments Platform (STEP) offers a timely opportunity to mechanically qualify and characterize the antenna design in a representative environment. The proposed experimental configuration would employ a half-system of the full-scale RADARSAT antenna which would be mounted on the STEP platform in the orbiter cargo bay such that it could be deployed and retracted in orbit (as shown in this figure). The antenna would be subjected to typical environmental exposures while an array of targets and sensors on the antenna support structure and reflecting surface are observed and monitored. In particular, the typical environments would include deployment and retraction, dynamic response to vehicle thruster or base exciter inputs, and thermal soak and transient effects upon entering or exiting Earth eclipse. The proposed experiment would also provide generic information on the properties of large space structures in space and on techniques to obtain the desired information.

Zimcik, D. G.↗

Chromium electrodes for REDOX cells

An improved electrode having a gold coating for use in the anode compartment of a REDOX cell is described. The anode fluid utilizes a chromic/chromous couple. A carbon felt is soaked in methanol, rinsed in water, dried and then heated in KOH after which it is again washed in deionized water and dried. The felt is then moistened with a methanol water solution containing chloroauric acid and is stored in a dark place while still in contact with the gold-containing solution. After all the gold-containing solution is absorbed in the felt, the latter is dried by heat and then heat treated at a substantially greater temperature. The felt is then suitable for use as an electrode and is wetted with water or up to two molar HCl prior to installation in a REDOX cell. The novelty of the invention lies in the use of KOH for cleaning the felt and the use of alcohol as a carrier for the gold together with the heat treating procedure.

Jalan, V.↗

Turbine blade and vane heat flux sensor development, phase 1

Heat flux sensors available for installation in the hot section airfoils of advanced aircraft gas turbine engines were developed. Two heat flux sensors were designed, fabricated, calibrated, and tested. Measurement techniques are compared in an atmospheric pressure combustor rig test. Sensors, embedded thermocouple and the Gordon gauge, were fabricated that met the geometric and fabricability requirements and could withstand the hot section environmental conditions. Calibration data indicate that these sensors yielded repeatable results and have the potential to meet the accuracy goal of measuring local heat flux to within 5%. Thermal cycle tests and thermal soak tests indicated that the sensors are capable of surviving extended periods of exposure to the environment conditions in the turbine. Problems in calibration of the sensors caused by severe non-one dimensional heat flow were encountered. Modifications to the calibration techniques are needed to minimize this problem and proof testing of the sensors in an engine is needed to verify the designs.

Atkinson, W. H.↗

Comparison of visualized turbine endwall secondary flows and measured heat transfer patterns

Various flow visualization techniques were used to define the seondary flows near the endwall in a large heat transfer data. A comparison of the visualized flow patterns and the measured Stanton number distribution was made for cases where the inlet Reynolds number and exit Mach number were matched. Flows were visualized by using neutrally buoyant helium-filled soap bubbles, by using smoke from oil soaked cigars, and by a few techniques using permanent marker pen ink dots and synthetic wintergreen oil. Details of the horseshoe vortex and secondary flows can be directly compared with heat transfer distribution. Near the cascade entrance there is an obvious correlation between the two sets of data, but well into the passage the effect of secondary flow is not as obvious. Previously announced in STAR as N83-14435

Gaugler, R. E.↗

Aerothermodynamic environment and thermal protection for a Titan aerocapture vehicle

This paper presents thermal protection system (TPS) requirements for a potential Titan aerocapture vehicle. Shock-layer solutions are obtained for a nominal trajectory through the current Titan model atmosphere. Fully laminar and fully turbulent solutions are presented along the blunted fore-cone in the windward symmetry plane of a bent-biconic vehicle. Using these solutions to define the aerothermodynamic environment, transient material-response solutions are obtained for a Galileo-type TPS with a carbon-phenolic ablator heat shield. Shock-layer results indicate that turbulent flow is the more realistic flow condition. They also show that the lengthy aerocapture heating pulse is dominated by convective heating. The TPS results show that the required insulation thickness is uniformly about 4 cm along the fore-cone because of the long heat-soak period. The total heat-shield thickness is 6.4 cm at the stagnation point, and 4.7 cm near the end of the fore-cone. These TPS requirements are greater than those presented in a previous Titan aerocapture study.

Green, M. J.↗

Topological reaction rate measurements related to scuffing

A ball-on-plate (both consisting of hardened M-50 steel) sliding elastohydrodynamic contact was run with trimethylolpropane triheptanoate (TMPTH) with and without tricresyl phosphate (TCP). The contact area of the plate was optically profiled with a phase-locked interference microscope (PLIM) both before and after exposure to alcoholic hydrochloric acid. As scuffing was approached, the profile within the contact region changed more rapidly after the acid treatment; after scuffing, it assumed a constant high value. A metallurgical phase found in the scuff mark was apparently responsible for the high reactivity. The microscopic profile changes (sensitivity, + or - 3 nm (+ or - A) in depth) involved primarily the small asperities (radius, 3 microns); the larger ones were unaffected. Soaking the steel in TCP smoothed the fine structure of the surface profile but increased its reactivity toward alcoholic hydrochloric acid before sliding was started. Thus it would appear that PLIM examination could be used for screening potentially scuff-resistant materials.

Lauer, J. L.↗

Development of flight ready fifty-micron-thick silicon solar cell array module technology

The development of ultrathin silicon solar cell array modules from initial design to flight testing is discussed. Three 80-cell modules were subjected to the thermal soak test, the LEO thermal cycle test, and the solar array flight experiment, and six 48-cell welded modules were evaluated in the geosynchronous orbit thermal cycle test. It is observed that the electrical performance of the modules was not affected by the different environmental conditions. The automatic assembly of the cell modules, in particular the welding and solar cell glassing operation, is described. The specific power capabilities of Kapton, Kapton-Kevlar-Kapton, Kapton-graphite-Kapton, and Kapton-graphite-aluminum honeycomb-graphite solar array designs are assessed.

Patterson, R. E.↗

Development of heat flux sensors for turbine airfoils

The objectives of this program are to develop heat flux sensors suitable for installation in hot section airfoils of advanced aircraft turbine engines and to experimentally verify the operation of these heat flux sensors in a cylinder in a cross flow experiment. Embedded thermocouple and Gardon gauge sensors were developed and fabricated into both blades and vanes. These were then calibrated using a quartz lamp bank heat source and finally subjected to thermal cycle and thermal soak testing. These sensors were also fabricated into cylindrical test pieces and tested in a burner exhaust to verify heat flux measurements produced by these sensors. The results of the cylinder in cross flow tests are given.

Atkinson, William H.↗

Effects of moisture, elevated temperature, and fatigue loading on the behavior of graphite/epoxy buffer strip panels with center cracks

The effects of fatigue loading combined with moisture and heat on the behavior of graphite epoxy panels with either Kevlar-49 or S-glass buffer strips were studied. Buffer strip panels, that had a slit in the center to represent damage, were moisture conditioned or heated, fatigue loaded, and then tested in tension to measure their residual strength. The buffer strips were parallel to the loading direction and were made by replacing narrow strips of the 0 deg graphite plies with Kevlar-49 epoxy or S-glass epoxy on a 1-for-1 basis. The panels were subjected to a fatigue loading spectrum. One group of panels was preconditioned by soaking in 60 C water to produce a 1 percent weight gain then tested at room temperature. One group was heated to 82 C during the fatigue loading. Another group was moisture conditioned and then tested at 82 C. The residual strengths of the buffer panels were not highly affected by the fatigue loading, the number of repetitions of the loading spectrum, or the maximum strain level. The moisture conditioning reduced the residual strengths of the S-glass buffer strip panel by 10 to 15 percent below the ambient results. The moisture conditioning did not have a large effect on the Kevlar-49 panels.

Bigelow, C. A.↗

Thermal properties and effects for Li/BCX (thionyl chloride) cells

New NASA requirements for the screening of lithium cells for space applications involve thermal soaks at elevated temperatures (149 C). The currently qualified Li/BCX cells and three design modifications have been evaluated showing that a design incorporating a shortened electrode stack met this test condition while continuing to satisfy the performance and safety requirements for cells used on NASA manned space vehicles. Information was also developed to show that measured heat capacities for the BCX D size cells correlated well with the heat generated from cells discharged in an insulated environment. Calculated heat capacities based on the amounts and types of materials in a cell were low compared to these values. This information provides the basis for the design of battery packs in the highly insulating environment of outer space.

Takeuchi, E. S.↗

Iodine sorption study on the proposed use of Viton A in a shuttle galley water accumulator

The installation of a Viton A accumulator in the Shuttle galley has been proposed to prevent overpressurization of the hot water supply system. A laboratory study has been conducted to determine if there would be any interaction between the Viton A material and the iodine used to disinfect the water. Coupons of Viton A were exposed for 24 hours to aqueous iodine solutions similar in quality to the Shuttle's potable water. Changes in the iodine residual were monitored to determine the rate of iodine sorption by the coupon. Total organic carbon (TOC) was monitored to determine the rate of desorption of organic materials from the Viton A. The same coupons were then soaked in reagent-grade water for 24 hours, and iodine was monitored to determine the rate of iodine desorption. The coupons were again exposed to iodine solutions for 24 hours and iodine and TOC were monitored. No significant change in the iodine sorption rate was detected between the first and second exposures. A triangle taste test indicated at a 1 percent confidence level that the water exposed to Viton A had a different taste which was less acceptable to the panelists.

Gibbons, Randall E.↗

A study of thermal transitions in a new semicrystalline thermoplastic polyimide

A polyimide derive from 4,4'-isophthaloyl diphthalic anhydride (IDPA) and 1,3-bis (4-aminophenoxy 4'-benzoyl) benzene (1,3-BABB) having semicrystalline behavior was prepared and characterized by differential scanning calorimetry (DSC) and wide angle X-ray scattering (WAXS). Thus a poly(amic acid) film cured in air for one hour each at 100 and 200 C displayed an endotherm at 286 C, followed by a crystallization exotherm at 317 C, and a second melting transition at 350 C. The 286 C melting point appeared to result from earlier solvent-induced crystallization. Films cast from DMAc, air dried, and soaked in methylene chloride could not be induced into semicrystallinity. The fully cured polyimide has a Tg of 216 C. Films heated to temperatures as high as 100 C for one hour in air were transparent and light yellow in color. Those films heated to or above 125 C were translucent. Polarized light microscopy revealed the presence of spherulites 608 micrometers in diameter in a sample cured to 275 C in air. Two film samples, one cured to 275 and the other to 325 C, were evaluated for tensile and ultimate strength, modulus, and percent elongation at 25 and 200 C. These values remained essentially constant at each test temperature.

Pratt, J. Richard↗

Advanced APS impacts on vehicle payloads

Advanced auxiliary propulsion system (APS) technology has the potential to both, increase the payload capability of earth-to-orbit (ETO) vehicles by reducing APS propellant mass, and simplify ground operations and logistics by reducing the number of fluids on the vehicle and eliminating toxic, corrosive propellants. The impact of integrated cryogenic APS on vehicle payloads is addressed. In this system, launch propulsion system residuals are scavenged from integral launch propulsion tanks for use in the APS. Sufficient propellant is preloaded into the APS to return to earth with margin and noncomplete scavenging assumed. No propellant conditioning is required by the APS, but ambient heat soak is accommodated. High temperature rocket materials enable the use of the unconditioned hydrogen/oxygen in the APS and are estimated to give APS rockets specific impulse of up to about 444 sec. The payload benefits are quantified and compared with an uprated monomethylhydrazine/nitrogen tetroxide system in a conservative fashion, by assuming a 25.5 percent weight growth for the hydrogen/oxygen system and a 0 percent weight growth for the uprated system. The combination of scavenging and high performance gives payload impacts which are highly mission specific. A payload benefit of 861 kg (1898 lbm) was estimated for a Space Station Freedom rendezvous mission and 2099 kg (4626 lbm) for a sortie mission, with payload impacts varying with the amount of launch propulsion residual propellants. Missions without liquid propellant scavenging were estimated to have payload penalties, however, operational benefits were still possible.

Schneider, Steven J.↗