Search NASA⌕ Search

SEARCH · Search NASA

Results for “software specification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Friendly Extensible Transfer Tool Beta Version

Often data transfer software is designed to meet specific requirements or apply to specific environments. Frequently, this requires source code integration for added functionality. An extensible data transfer framework is needed to more easily incorporate new capabilities, in modular fashion. Using FrETT framework, functionality may be incorporated (in many cases without need of source code) to handle new platform capabilities: I/O methods (e.g., platform specific data access), network transport methods, data processing (e.g., data compression.).

Collins, William P.↗

Simplifying the Tracking of Waste Disposal Inventories: Process Improvement for Rapid Data Interpretation and Reduced Errors - 16143

Tracking the inventory of low-level radioactive waste at an operating disposal facility offers unique challenges. At the Savannah River Site's Saltstone Disposal Facility (SDF) the inventory used in Performance Assessment modeling is determined based on radionuclide concentrations from the aqueous waste in a feed tank and the volume of the waste that is transferred from the feed tank to the Saltstone Production Facility (SPF). These inputs are reported quarterly. As such, the disposal inventories are also updated quarterly; however, due to decay and ingrowth, the inventory values for some radionuclides can be misrepresented if the data is not tracked appropriately. Additionally, it is not feasible to analyze the feed tank samples for every possible radionuclide; therefore, a series of adjustments are necessary to estimate the concentrations of radionuclides that are not explicitly measured but still pose a potential dose risk. Prior to 2015, the SDF disposal inventories were updated using a series of spreadsheets that required users to perform a significant number of steps (including manually transferring data back and forth between a separate decay and ingrowth calculation software). Despite this labor intensive approach, the process only provided single point-in-time results. With multiple steps, minimal automation, and limited result data, this approach to inventory tracking was not ideal and minor mistakes were often identified during the equally cumbersome review process. As a process improvement, the simplified SDF Waste Inventory Disposed Estimator (SDF-WIDE) Model was developed using GoldSim software. The software allows users to identify specific dates to define the duration of the simulation, from the beginning of operations until the time of future facility closure, and provides graphical interfaces for displaying data over time. Further, GoldSim's Contaminant Transport Module is used to perform the decay and ingrowth calculations, making the model completely self-contained (i.e., there is no need to transfer intermediate data back and forth between different programs). GoldSim also includes model 'versioning' features that significantly reduce the time needed to perform the appropriate quality assurance reviews as required for each quarterly inventory update. By transitioning from the complex spreadsheets to the simplified SDFWIDE model, the time needed to perform updates to the SDF inventory has been reduced from days to hours, the risk of making human errors has been greatly mitigated, and users are able to quickly observe trends in the data over time. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MO-E-17A-10: Evaluation of Body and Head Dimensions of Pediatric Patients as a Function of Age

Purpose: Phantom development in medical physics plays an important role in radiation dose assessment and image quality evaluation, and this is especially true in the pediatric patient population. The purpose of this investigation was to establish the relationship between patient age and patient size, focusing on the abdomen-pelvis and head effective diameters, for patients ranging in age from newborn to 18 years. Methods: A dose reporting tool for computed tomography systems was installed at our institution to achieve compliance with state law commencing on July 1, 2012. The software records a number of patient-specific data, and also reports CT dose metrics (CTDIvol and DLP) into the patients interpretive report. The database generated by the software was mined to determine patient effective diameter as a function of age for pediatric patients aged 0–18 years. CT protocols including abdomen-pelvis and routine head were evaluated, and specific to this study the patients age, gender and equivalent diameter were recorded. Results: Six age ranges were evaluated: A(0–3), B(4–6), C(7–9), D(10–12),E(13–15),F(16–18). For the torso in these groups based upon 694 patients, median effective diameters were 147, 167, 184, 214, 231, 246 mm, respectively. For the head (N=1833), median diameters were 143, 157, 162, 168, 174, and 174, respectively. Conclusion: A solid understanding of the approximate dimensions of pediatric patients as a function of age is useful in the development of age-based imaging protocols and dose assessments. CT dose-reporting tools generate a great deal of data with respect to body dimensions automatically. In this study, median equivalent diameters for the abdomen-pelvis and head of pediatric patients were evaluated. These data may prove useful in the development of both mathematical and physical phantoms for dosimetry and image quality assessment.

60 APPLIED LIFE SCIENCES↗

An Open-Source Framework for Rapid Validation of Scientific ASICs

Spacely is an open-source framework for the post-silicon validation of analog, digital, and mixed-signal ASICs (Application-Specific Integrated Circuits) which maximizes the reuse of hardware and software, reducing the time taken to achieve meaningful test results. Spacely specifically addresses the needs of small, flexible ASIC design teams commonly found in academia or research institutions which benefit most from sharing the overhead of test stand creation between many unique ASIC designs. Spacely is a set of software, firmware, and design practices. It targets two primary hardware platforms (NI-PXI and Caribou) as well as offering extensible support for bench instruments. Spacely provides a high-level Python interface to all test hardware for accessibility, while also giving more sophisticated teams the opportunity to integrate custom test firmware. The design principles of Spacely are presented in brief. Current documentation is available at https://github.com/SpacelyProject/spacely-docs.

Quinn, Adam [Fermilab]↗

An Open-Source Framework for Rapid Validation of Scientific ASICs

Spacely is an open-source framework for the post-silicon validation of analog, digital, and mixed-signal ASICs (Application-Specific Integrated Circuits) which maximizes the reuse of hardware and software, reducing the time taken to achieve meaningful test results. Spacely specifically addresses the needs of small, flexible ASIC design teams commonly found in academia or research institutions which benefit most from sharing the overhead of test stand creation between many unique ASIC designs. Spacely is a set of software, firmware, and design practices. It targets two primary hardware platforms (NI-PXI and Caribou) as well as offering extensible support for bench instruments. Spacely provides a high-level Python interface to all test hardware for accessibility, while also giving more sophisticated teams the opportunity to integrate custom test firmware. The design principles of Spacely are presented, along with a demonstrative example of using Spacely to test a pixel detector readout ASIC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards Vendor and Operating System Independence of USB-based portable multi-channel analyzers

The nuclear measurements group is called on to develop portable, user friendly systems that performs at, or near, laboratory standards. These systems typically consist of a detector and a USB-based multi-channel analyzer. An ORTEC digi-Base is an example of a USB-based portable multi-channel analyzer with 14-pin photomultiplier tube base for gamma-ray spectroscopy applications with NaI(Tl) and other scintillation detectors. Operating system independence - we want to be able to develop applications that are 'future-proof' and can run on the best hardware for the job: desktop, laptop, tablet, phone, or embedded device. To do that we need our software to be operating system independent. Hardware vendor independence - to use the most appropriate equipment for the job, while still maintaining our rapid method development, we would like our software that uses this equipment to be independent of the specific vendor or model of the hardware. To do that we need a common interface to each vendor's equipment (high voltage, gain, start, stop, clear, etc.) In prior work, we were able to use an existing library to communicate with an ORTEC digi-base via Linux and Android. However the application developed did not have a user friendly front-end. Part of this work was to develop a simple user interface to control the settings of the hardware from Android. While OS independence is the final goal, another goal is standardized software for user-application development. For current purposes those standard systems are Windows 7, Windows 10, and Python 3. Our next step was to develop a common software interface between a front-end user interface and back-end hardware communication software. This was done using Python's Ctypes library. Ctypes is a foreign function library for Python. It provides C compatible data types, and allows calling functions in DLLs or shared libraries. It can be used to wrap these libraries in pure Python. Ctypes exports the cdll, and Windows windll and oledll objects, for loading dynamic link libraries. You load libraries by accessing them as attributes of these objects. cdll loads libraries which export functions using the standard cdecl calling convention. The first steps of developing the common software interface have been done. Once the software interface has been developed the next goal will be to develop hardware specific back-end software that way rapid user facing software can be developed using equipment that is 'on-hand' and once finished prototyping, the 'best' hardware can be chosen for the specific implementation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of the accuracy of 3DVH software estimates of dose to virtual ion chamber and film in composite IMRT QA

Purpose: A novel patient-specific intensity modulated radiation therapy (IMRT) QA system, 3DVH software and mapcheck 2, purports to be able to use diode array-measured beam doses and the patient's DICOM RT plan, structure set, and dose files to predict the delivered 3D dose distribution in the patient for comparison to the treatment planning system (TPS) calculated doses. In this study, the composite dose to an ion chamber and film in phantom predicted by the 3DVH and mapcheck 2 system is compared to the actual measured chamber and film doses. If validated in this context, then 3DVH can be used to perform an equivalent dose analysis as that obtained with film dosimetry and ion chamber-based composite IMRT QA. This is important for those losing their ability to perform film dosimetry for true composite IMRT QA and provides a measure of confidence in the accuracy of 3DVH 3D dose calculations which may replace phantom-based IMRT QA. Methods: The dosimetric results from 15 consecutive patient-specific IMRT QA tests performed by composite field irradiation of ion chamber and EDR2 film in a solid water phantom were compared to the predicted doses for those virtual detectors based on the calculated 3D dose by the 3DVH software using mapcheck 2 measured doses of each beam within each plan. For each of the 15 cases, immediately after performing the ion chamber plus film measurements, the mapcheck 2 was used to measure the dose for each beam of the plan. The dose to the volume of the virtual ion chamber and the dose distribution in the plane of the virtual film calculated by the 3DVH software was extracted. The ratio of the measured to 3DVH or eclipse-predicted ion chamber doses was calculated. The same plane in the phantom measured using film and calculated with eclipse was exported from 3DVH and the 2D gamma metric was used to compare the relationship between the film doses and the eclipse or 3DVH predicted planar doses. Also, the 3D gamma value was calculated in the 3DVH software which compares the eclipse dose to the 3DVH predicted dose distribution. For the 2D and 3D gamma metrics, 2% dose and 2 mm distance to agreement (DTA) were used. In addition, a simple dose difference was performed using either a 2% or 3% dose difference tolerance. Results: The mean ratio {+-} standard deviation of the measured vs 3DVH or vs eclipse-predicted dose to the ion chamber was 1.013 {+-} 0.015 and 1.003 {+-} 0.012, respectively. For 3DVH vs eclipse, the mean percentage of pixels failing the 3D gamma metric was 1.2% {+-} 1.4% while the failure rate for the 2D gamma metric was 1.1% {+-} 0.9%. When either 3DVH or eclipse was compared to EDR2 film, the gamma failure rate was 2.3% {+-} 2.0% and 1.6% {+-} 1.7%, respectively. Mean dose difference failures were 9%-27% {+-} 5%-15% for 2 or 3% dose difference tolerances, depending on the combination of systems tested. No statistically significant differences were found for any of the planar dosimetric comparisons. Conclusions: 3DVH + mapcheck 2 predicts the same absolute dose, the percent of pixels failing the gamma metric, and the percent of pixels failing 2% or 3% dose difference tolerance tests as one would have obtained had one made measurements in solid water phantom using an ion chamber and coronal film instead of a diode array. This is also a necessary although not sufficient condition for validation of the accuracy of 3DVH predictions of the 3D dose using beam-by-beam measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Battery Life Estimator (BLE) Data Analysis Software v. 1.2

The purpose of this software is estimate the useable life of rechargeable batteries (e.g., lithium-ion). The software employs a generalized statistical approach to model cell data in the context of accelerated aging experiments. The cell performance is modeled in two parts. The first part consists of a deterministic degradation model which models the average cell behavior. The second part relates to the statistical variation in performance of the cells (error model). Experimental data from an accelerated aging experiment will be input from an Excel worksheet. The software will then query the user for a specific model form (within the generalized model framework). Model parameters will be estimated by the software using various statistical methodologies. Average cell life will be predicted using the estimated model parameters. The uncertainty in the estimated cell life will also be computed using bootstrap simulations. This software can be used in several modes: 1) fit only, 2) fit and simulation, and 3) simulation only

Thomas, Edward↗

SpacelyProject/spacely-docs

Spacely is an open-source framework for the post-silicon validation of analog, digital, and mixed-signal ASICs (Application-Specific Integrated Circuits) which maximizes the reuse of hardware and software, reducing the time taken to achieve meaningful test results. Spacely specifically addresses the needs of small, flexible ASIC design teams commonly found in academia or research institutions. Spacely was originally developed at Fermi National Accelerator Laboratory.

Quinn, Adam [Fermi National Accelerator Laboratory↗

Specification of Fenix MPI Fault Tolerance library (V.0.9)

Fenix is a software library compatible with the Message Passing Interface (MPI) to support fault recovery without application shutdown. This specification is derived from a current implementation of Fenix that employs the User Level Fault Mitigation (ULFM) MPI fault tolerance module proposal. We only present the C library interface for Fenix; the Fortran interface will be added once the C version is complete.

97 MATHEMATICS AND COMPUTING↗

Domain Specific Language Support for Exascale

Domain-Specific Languages (DSLs) offer an attractive path to Exascale software since they provide expressive power through appropriate abstractions and enable domain-specific optimizations. But the advantages of a DSL compete with the difficulties of implementing a DSL, even for a narrowly defined domain. The DTEC project addresses how a variety of DSLs can be easily implemented to leverage existing compiler analysis and transformation capabilities within the ROSE open source compiler as part of a research program focusing on Exascale challenges. The OSU contributions to the DTEC project are in the area of code generation from high-level DSL descriptions, as well as verification of the automatically-generated code.

97 MATHEMATICS AND COMPUTING↗

Summary of Documentation for DYNA3D-ParaDyn's Software Quality Assurance Regression Test Problems

The Software Quality Assurance (SQA) regression test suite for DYNA3D (Zywicz and Lin, 2015) and ParaDyn (DeGroot, et al., 2015) currently contains approximately 600 problems divided into 21 suites, and is a required component of ParaDyn’s SQA plan (Ferencz and Oliver, 2013). The regression suite allows developers to ensure that software modifications do not unintentionally alter the code response. The entire regression suite is run prior to permanently incorporating any software modification or addition. When code modifications alter test problem results, the specific cause must be determined and fully understood before the software changes and revised test answers can be incorporated. The regression suite is executed on LLNL platforms using a Python script and an associated data file. The user specifies the DYNA3D or ParaDyn executable, number of processors to use, test problems to run, and other options to the script. The data file details how each problem and its answer extraction scripts are executed. For each problem in the regression suite there exists an input deck, an eight-processor partition file, an answer file, and various extraction scripts. These scripts assemble a temporary answer file in a specific format from the simulation results. The temporary and stored answer files are compared to a specific level of numerical precision, and when differences are detected the test problem is flagged as failed. Presently, numerical results are stored and compared to 16 digits. At this accuracy level different processor types, compilers, number of partitions, etc. impact the results to various degrees. Thus, for consistency purposes the regression suite is run with ParaDyn using 8 processors on machines with a specific processor type (currently the Intel Xeon E5530 processor). For non-parallel regression problems, i.e., the two XFEM problems, DYNA3D is used instead. When environments or platforms change, executables using the current source code and the new resource are created and the regression suite is run. If differences in answers arise, the new answers are retained provided that the differences are inconsequential. This bootstrap approach allows the test suite answers to evolve in a controlled manner with a high level of confidence. Developers also run the entire regression suite with (serial) DYNA3D. While these results normally differ from the stored (parallel) answers, abnormal termination or wildly different values are strong indicators of potential issues.

42 ENGINEERING↗

EIC Software Overview

Development of the EIC project detector "ePIC" is now well underway and this includes the "single software stack" used for simulation and reconstruction. The stack combines several non-experiment-specific packages including ACTS, DD4hep, JANA2, and PODIO. The software stack aims to be forward looking in the era of AI/ML and heterogeneous hardware. A formal decision making process was implemented to choose the components that involved everyone in the collaboration that was interested. This talk will present an overview of the software stack currently used for development of the ePIC detector and on which we expect to execute the experiment.

Lawrence, David↗

EIC Software Overview

Development of the EIC project detector "ePIC" is now well underway and this includes the "single software stack" used for simulation and reconstruction. The stack combines several non-experiment-specific packages including ACTS, DD4hep, JANA2, and PODIO. The software stack aims to be forward looking in the era of AI/ML and heterogeneous hardware. A formal decision making process was implemented to choose the components that involved everyone in the collaboration that was interested. This talk will present an overview of the software stack currently used for development of the ePIC detector and on which we expect to execute the experiment.

Lawrence, David↗

Modeling of a Parabolic Trough Solar Field for Acceptance Testing: A Case Study

As deployment of parabolic trough concentrating solar power (CSP) systems ramps up, the need for reliable and robust performance acceptance test guidelines for the solar field is also amplified. Project owners and/or EPC contractors often require extensive solar field performance testing as part of the plant commissioning process in order to ensure that actual solar field performance satisfies both technical specifications and performance guaranties between the involved parties. Performance test code work is currently underway at the National Renewable Energy Laboratory (NREL) in collaboration with the SolarPACES Task-I activity, and within the ASME PTC-52 committee. One important aspect of acceptance testing is the selection of a robust technology performance model. NREL1 has developed a detailed parabolic trough performance model within the SAM software tool. This model is capable of predicting solar field, sub-system, and component performance. It has further been modified for this work to support calculation at subhourly time steps. This paper presents the methodology and results of a case study comparing actual performance data for a parabolic trough solar field to the predicted results using the modified SAM trough model. Due to data limitations, the methodology is applied to a single collector loop, though it applies to larger subfields and entire solar fields. Special consideration is provided for the model formulation, improvements to the model formulation based on comparison with the collected data, and uncertainty associated with the measured data. Additionally, this paper identifies modeling considerations that are of particular importance in the solar field acceptance testing process and uses the model to provide preliminary recommendations regarding acceptable steady-state testing conditions at the single-loop level.

14 SOLAR ENERGY↗

Sensitive and Specific Peak Detection for SELDI-TOF Mass Spectrometry Using a Wavelet/Neural-Network Based Approach

SELDI-TOF mass spectrometer’s compact size and automated, high throughput design have been attractive to clinical researchers, and the platform has seen steady-use in biomarker studies. Despite new algorithms and preprocessing pipelines that have been developed to address reproducibility issues, visual inspection of the results of SELDI spectra preprocessing by the best algorithms still shows miscalled peaks and systematic sources of error. This suggests that there continues to be problems with SELDI preprocessing. In this work, we study the preprocessing of SELDI in detail and introduce improvements. While many algorithms, including the vendor supplied software, can identify peak clusters of specific mass (or m/z) in groups of spectra with high specificity and low false discover rate (FDR), the algorithms tend to underperform estimating the exact prevalence and intensity of peaks in those clusters. Thus group differences that at first appear very strong are shown, after careful and laborious hand inspection of the spectra, to be less than significant. Here we introduce a wavelet/neural network based algorithm which mimics what a team of expert, human users would call for peaks in each of several hundred spectra in a typical SELDI clinical study. The wavelet denoising part of the algorithm optimally smoothes the signal in each spectrum according to an improved suite of signal processing algorithms previously reported (the LibSELDI toolbox under development). The neural network part of the algorithm combines those results with the raw signal and a training dataset of expertly called peaks, to call peaks in a test set of spectra with approximately 95% accuracy. The new method was applied to data collected from a study of cervical mucus for the early detection of cervical cancer in HPV infected women. The method shows promise in addressing the ongoing SELDI reproducibility issues.

59 BASIC BIOLOGICAL SCIENCES↗

Wasatch: An architecture-proof multiphysics development environment using a Domain Specific Language and graph theory

To address the coding and software challenges of modern hybrid architectures, we propose an approach to multiphysics code development for high-performance computing. This approach is based on using a Domain Specific Language (DSL) in tandem with a directed acyclic graph (DAG) representation of the problem to be solved that allows runtime algorithm generation. When coupled with a large-scale parallel framework, the result is a portable development framework capable of executing on hybrid platforms and handling the challenges of multiphysics applications. In addition, we share our experience developing a code in such an environment – an effort that spans an interdisciplinary team of engineers and computer scientists.

97 MATHEMATICS AND COMPUTING↗