Search NASA⌕ Search

SEARCH · Search NASA

Results for “source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Development and testing of a pulsed helium ion source for probing materials and warm dense matter studies

The neutralized drift compression experiment was designed and commissioned as a pulsed, linear induction accelerator to drive thin targets to warm dense matter (WDM) states with peak temperatures of ∼1 eV using intense, short pulses (∼1 ns) of 1.2 MeV lithium ions. At that kinetic energy, heating a thin target foil near the Bragg peak energy using He{sup +} ions leads to more uniform energy deposition of the target material than Li{sup +} ions. Experiments show that a higher current density of helium ions can be delivered from a plasma source compared to Li{sup +} ions from a hot plate type ion source. He{sup +} beam pulses as high as 200 mA at the peak and 4 μs long were measured from a multi-aperture 7-cm-diameter emission area. Within ±5% variation, the uniform beam area is approximately 6 cm across. The accelerated and compressed pulsed ion beams can be used for materials studies and isochoric heating of target materials for high energy density physics experiments and WDM studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanoscience at the advanced photon source

The U.S. Department of Energy's (DOE's) Advanced Photon Source (APS), located at Argonne National Laboratory, is a 3rd-generation synchrotron radiation source of hard X-rays. Also sited at Argonne is the Center for Nanoscale Materials (CNM), one of the five Nanoscience Research Centers that have been created by the DOE's Office of Basic Energy Sciences. The APS and CNM are closely connected, both physically and intellectually, as the CNM building is attached to the APS experiment hall, and the APS and CNM jointly operate the nanoprobe beamline at APS Sector 26 that was constructed as part of the CNM project. Both the APS and CNM are user facilities and their synergy provides the research community with a unique suite of tools for the fabrication and characterization of nanomaterials. This talk will summarize the capabilities of the nanoprobe beamline and some of the recent nanoscience results from data collected at the APS.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Revisiting streamside trees that do not use stream water: can the two water worlds hypothesis and snowpack isotopic effects explain a missing water source?: Riparian tree water sources

We revisit a classic ecohydrological study that showed streamside riparian trees in a semiarid mountain catchment did not use perennial stream water. The original study suggested that mature individuals of Acer negundo, Acer grandidentatum, and other species were dependent on water from “deeper strata,” possibly groundwater. We used a dual stable isotope approach (δ 18 O and δ 2 H) to further examine the water sources of these trees. We tested the hypothesis that groundwater was the main tree water source, but found that neither groundwater nor stream water matched the isotope composition of xylem water during two growing seasons. Soil water (0–1 m depth) was closest to and periodically overlapped with xylem water isotope composition, but overall, xylem water was isotopically enriched compared to all measured water sources. The “two water worlds” hypothesis postulates that soil water comprises isotopically distinct mobile and less mobile pools that do not mix, potentially explaining this disparity. We further hypothesized that isotopic effects during snowpack metamorphosis impart a distinct isotope signature to the less mobile soil water that supplies summer transpiration. Depth trends in water isotopes following snowmelt were consistent with the two water worlds hypothesis, but snow metamorphic isotope effects could not explain the highly enriched xylem water. Thus, the dual isotope approach did not unambiguously determine the water source(s) of these riparian trees. Further exploration of physical, geochemical, and biological mechanisms of water isotope fractionation and partitioning is necessary to resolve these data, highlighting critical challenges in the isotopic determination of plant water sources.

54 ENVIRONMENTAL SCIENCES↗

Comparative performance assessment of air-source and ground-source heat pumps using CO₂ and R-410A with water well integration: A simulation study

This study investigates the performance and feasibility of heat pump systems for residential space heating in cold climates, with a particular focus on ground source heat pumps (GSHPs) with water wells. Four configurations are modeled and compared, a CO 2 air-source heat pump (ASHP), an R-410A ASHP, a CO 2 GSHP with water well integration, and an R-410A ground-source heat pump with water well integration. System simulations are conducted at both equipment and whole-building levels, followed by a nationwide analysis across ten representative cities using EnergyPlus. Results show that water-well-coupled GSHPs maintain approximately 87 % of their efficiency and 85.5 % of heating capacity as ambient temperature drops from 47 °F/8.3 °C to −15 °F/-26.1 °C, whereas ASHPs retain only 55 % efficiency and 44.5 % capacity. R-410A systems achieve higher efficiency, while CO 2 systems provide significant environmental advantages, including reduced risks of groundwater contamination from refrigerant leakage. On average, the CO 2 GSHPs deliver 35–45 % heating energy savings relative to ASHPs and demonstrate strong potential as a replacement for gas furnaces in cold climates. This work represents a systematic comparative assessment of CO 2 and R-410A air-source and ground-source heat pumps with water well integration. In conclusion, the findings highlight the technical viability, environmental benefits and deployment potential of CO 2 GSHPs, offering a pathway toward efficient and sustainable residential heating solutions in diverse U.S. climates.

CO 2 GSHP↗

Cluster ion source for external injection and high capacity filling of light elements into the relativistic heavy ion collider electron beam ion source

An advanced Electron Beam Ion Source (EBIS) is the primary ion source to supply highly charged ion beams of different elements to the Relativistic Heavy Ion Collider (RHIC) and to the NASA Space Radiation Laboratory (NSRL). Intense beams of highly charged ions of various elements of the periodic table, ranging from helium to uranium, have been demonstrated since EBIS became operational in 2010. EBIS routinely provides ion beams to RHIC and NSRL quasisimultaneously with about 1 s switching time between different ion species. Such unique flexibility and rapid switching between ion species are based on external injection of singly charged ions into the EBIS trap either in “fast” or “slow” injection modes. At present, a Laser Ion Source (LIS) provides most of the ion species of solid materials using the “fast” injection mode into the EBIS trap and a Hollow Cathode Ion Source (HCIS) provides most of the ion species of gaseous elements using the “slow” injection mode into the EBIS trap. Gas injection into the EBIS trap is also possible and has been used but imposes some restrictions for the simultaneous generation of highly charged ions such as Au 32+ ions for RHIC and ions of gaseous species for NSRL. Because light ions have relatively high velocity inside the EBIS trap, efficient injection of hydrogen and helium ions and filling of the EBIS trap to high capacity is difficult from either LIS or HCIS. To overcome this restriction and enhance EBIS operational capability, we suggest injecting beams of hydrogen and helium cluster ions into the EBIS trap. Required parameters of cluster ion beam injection into the EBIS trap are estimated, and advantages of such an injection are highlighted. A cluster ion source with required high intensity is visible and will be designed, built, optimized, and tested.

43 PARTICLE ACCELERATORS↗

The Effects of Atmospheric Models on the Estimation of Infrasonic Source Functions at the Source Physics Experiment

We invert infrasound signals for an equivalent seismoacoustic source function using different atmospheric models to produce the necessary Green’s functions. The infrasound signals were produced by a series of underground chemical explosions as part of the Source Physics Experiment (SPE). In a previous study, we inverted the infrasound data using so-called predictive atmospheric models, which were based on historic, regional-scaled, publicly available weather observations interpolated onto a 3D grid. For the work presented here, we invert the same infrasound data, but using atmospheric models based on weather data collected in a time window that includes the approximate time of the explosion experiments, which we term postdictive models. We build two versions of the postdictive models for each SPE event: one that is based solely on the regional scaled observations, and one that is based on both regional scaled observations combined with on-site observations obtained by a weather sonde released at the time of the SPE. We then invert the observed data set three times, once for each atmospheric model type. We find that the estimated seismoacoustic source functions are relatively similar in waveform shape regardless of which atmospheric model that we used to construct the Green’s functions. However, we find that the amplitude of the estimated source functions is systematically dependent on the atmospheric model type: using the predictive atmospheric models to invert the data generally yields estimated source functions that are larger in amplitude than those estimated using the postdictive models.

54 ENVIRONMENTAL SCIENCES↗

Spatially Resolved Elemental Analysis, Spectroscopy and Diffraction at the GSECARS Sector at the Advanced Photon Source

X‐ray microprobes (XRM) coupled with high‐brightness synchrotron X‐ray facilities are powerful tools for environmental biogeochemistry research. One such instrument, the XRM at the Geo Soil Enviro Center for Advanced Radiation Sources Sector 13 at the Advanced Photon Source (APS; Argonne National Laboratory, Lemont, IL) was recently improved as part of a canted undulator geometry upgrade of the insertion device port, effectively doubling the available undulator beam time and extending the operating energy of the branch supporting the XRM down to the sulfur K edge (2.3 keV). Capabilities include rapid, high‐resolution, elemental imaging including fluorescence microtomography, microscale X‐ray absorption fine structure spectroscopy including sulfur K edge capability, and microscale X‐ray diffraction. These capabilities are advantageous for (i) two‐dimensional elemental mapping of relatively large samples at high resolution, with the dwell times typically limited only by the count times needed to obtain usable counting statistics for low concentration elements, (ii) three‐dimensional imaging of internal elemental distributions in fragile hydrated specimens, such as biological tissues, avoiding the need for physical slicing, (iii) spatially resolved speciation determinations of contaminants in environmental materials, and (iv) identification of contaminant host phases. In this paper, we describe the XRM instrumentation, techniques, applications demonstrating these capabilities, and prospects for further improvements associated with the proposed upgrade of the APS. Core Ideas X‐ray microprobes are powerful tools for environmental biogeochemistry. Upgraded GSECARS XRM operates down to the sulfur K edge. Capabilities: spatially resolved elemental analysis, spectroscopy, and diffraction. Advanced Photon Source upgrade will further advance XRM capabilities.

Sutton, Stephen R.↗

Plasma emission spectroscopy for operating and developing the Spallation Neutron Source (SNS) H- ion sources

An RF-driven, Cs-enhanced H- ion source feeds the SNS accelerator with a high current (typically >50 mA), ~1.0 ms pulsed beam at 60 Hz. To achieve the persistent high current beam for several weeks long service cycles, each newly installed ion source undergoes a rigorous conditioning and cesiation processes. Plasma conditioning outgases the system and sputter-cleans the ion conversion surfaces. A cesiation process immediately following the plasma conditioning releases Cs to provide coverage on the ion conversion surfaces. The effectiveness of the ion source conditioning and cesiation is monitored with plasma emission spectroscopy using a high-sensitivity optical spectrometer. Plasma emission spectroscopy is also used to provide a mean for diagnosing and confirming a failure of the insulating coating of the ion source RF antenna which is immersed in the plasma. Emissions of composition elements of the antenna coating material, Na emission being the most significant, drastically elevate to signal a failure when it happens. Plasma spectra of the developmental ion source with an AlN chamber and an external RF antenna are also briefly discussed.

Han, Baoxi↗

Non-uniform Neutron Source Approximation for Iterative Reconstruction of Coded Source Images

X-ray and neutron optics both lack ray focusing capabilities. An x-ray source can be made small and powerful enough to facilitate high-resolution imaging while providing adequate flux. This is not yet possible for neutrons. One remedy is to employ a computational imaging technique such as magnified coded source imaging. The greatest challenge associated with successful reconstruction of high-resolution images from such radiographs is to precisely model the flux distribution for complex non-uniform neutron sources. We have developed a framework based on Monte Carlo simulation and iterative reconstruction that facilitates high- resolution coded source neutron imaging. In this paper, we define a methodology to empirically measure and approximate the flux profile of a non-uniform neutron source, and we show how to incorporate the result within the forward model of an iterative reconstruction algorithm. We assess improvement in image quality by comparing reconstructions based respectively on the new empirical forward model and our previous analytic models.

Gregor, Jens↗

Flat Field Anomalies in an X-ray CCD Camera Measured Using a Manson X-ray Source

The Static X-ray Imager (SXI) is a diagnostic used at the National Ignition Facility (NIF) to measure the position of the X-rays produced by lasers hitting a gold foil target. The intensity distribution taken by the SXI camera during a NIF shot is used to determine how accurately NIF can aim laser beams. This is critical to proper NIF operation. Imagers are located at the top and the bottom of the NIF target chamber. The CCD chip is an X-ray sensitive silicon sensor, with a large format array (2k x 2k), 24 μm square pixels, and 15 μm thick. A multi-anode Manson X-ray source, operating up to 10kV and 10W, was used to characterize and calibrate the imagers. The output beam is heavily filtered to narrow the spectral beam width, giving a typical resolution E/ΔE≈10. The X-ray beam intensity was measured using an absolute photodiode that has accuracy better than 1% up to the Si K edge and better than 5% at higher energies. The X-ray beam provides full CCD illumination and is flat, within ±1% maximum to minimum. The spectral efficiency was measured at 10 energy bands ranging from 930 eV to 8470 eV. We observed an energy dependent pixel sensitivity variation that showed continuous change over a large portion of the CCD. The maximum sensitivity variation occurred at 8470 eV. The geometric pattern did not change at lower energies, but the maximum contrast decreased and was not observable below 4 keV. We were also able to observe debris, damage, and surface defects on the CCD chip. The Manson source is a powerful tool for characterizing the imaging errors of an X-ray CCD imager. These errors are quite different from those found in a visible CCD imager.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spallation neutron source saddle antenna H{sup -} ion source project

In this project we are developing an H{sup -} source which will synthesize the most important developments in the field of negative ion sources to provide high current, high brightness, good lifetime, high reliability, and high power efficiency. We describe two planned modifications to the present spallation neutron source external antenna source in order to increase the plasma density near the output aperture: (1) replacing the present 2 MHz plasma-forming solenoid antenna with a 13 MHz saddle-type antenna and (2) replacing the permanent multicusp magnetic system with a weaker electromagnet.

43 PARTICLE ACCELERATORS↗

A study of H+ production using metal hydride and other compounds by means of laser ion source

A laser ion source can provide wide variety of ion beams from solid target materials, however, it has been difficult to create proton beam efficiently. We examined capability of proton production using beeswax, polyethylene, and metal hydrides (MgH2 and ZrH2) as target materials. The results showed that beeswax and polyethylene could not be used to produce protons because these targets are transparent to the laser wavelength of 1064 nm. On the other hand, the metal hydrides could supply protons. Although the obtained particle numbers of protons were less than those of the metal ions, the metal hydrides could be used as a target for proton laser ion source.

08 HYDROGEN↗

Improved design of proton source and low energy beam transport line for European Spallation Source

The design update of the European Spallation Source (ESS) accelerator is almost complete and the construction of the prototype of the microwave discharge ion source able to provide a proton beam current larger than 70 mA to the 3.6 MeV Radio Frequency Quadrupole (RFQ) started. The source named PS-ESS (Proton Source for ESS) was designed with a flexible magnetic system and an extraction system able to merge conservative solutions with significant advances. The ESS injector has taken advantage of recent theoretical updates and new plasma diagnostics tools developed at INFN-LNS (Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare). The design strategy considers the PS-ESS and the low energy beam transport line as a whole, where the proton beam behaves like an almost neutralized non-thermalized plasma. Innovative solutions have been used as hereinafter described. Thermo-mechanical optimization has been performed to withstand the chopped beam and the misaligned focused beam over the RFQ input collimator; the results are reported here.

43 PARTICLE ACCELERATORS↗

Self characterization of a coded aperture array for neutron source imaging

The neutron imaging system at the National Ignition Facility (NIF) is an important diagnostic tool for measuring the two-dimensional size and shape of the neutrons produced in the burning deuterium-tritium plasma during the stagnation stage of inertial confinement fusion implosions. Since the neutron source is small (∼100 μm) and neutrons are deeply penetrating (>3 cm) in all materials, the apertures used to achieve the desired 10-μm resolution are 20-cm long, triangular tapers machined in gold foils. These gold foils are stacked to form an array of 20 apertures for pinhole imaging and three apertures for penumbral imaging. These apertures must be precisely aligned to accurately place the field of view of each aperture at the design location, or the location of the field of view for each aperture must be measured. In this paper we present a new technique that has been developed for the measurement and characterization of the precise location of each aperture in the array. We present the detailed algorithms used for this characterization and the results of reconstructed sources from inertial confinement fusion implosion experiments at NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FIVE NEW MILLISECOND PULSARS FROM A RADIO SURVEY OF 14 UNIDENTIFIED FERMI-LAT GAMMA-RAY SOURCES

We have discovered five millisecond pulsars (MSPs) in a survey of 14 unidentified Fermi Large Area Telescope sources in the southern sky using the Parkes radio telescope. PSRs J0101-6422, J1514-4946, and J1902-5105 reside in binaries, while PSRs J1658-5324 and J1747-4036 are isolated. Using an ephemeris derived from timing observations of PSR J0101-6422 (P = 2.57 ms, DM = 12 pc cm{sup -3}), we have detected {gamma}-ray pulsations and measured its proper motion. Its {gamma}-ray spectrum (a power law of {Gamma} = 0.9 with a cutoff at 1.6 GeV) and efficiency are typical of other MSPs, but its radio and {gamma}-ray light curves challenge simple geometric models of emission. The high success rate of this survey-enabled by selecting {gamma}-ray sources based on their detailed spectral characteristics-and other similarly successful searches indicate that a substantial fraction of the local population of MSPs may soon be known.

79 ASTRONOMY AND ASTROPHYSICS↗

Empirical deadtime corrections at synchrotron sources.

An experimental comparison of models for performing dead-time corrections of photon-counting detectors at synchrotron sources is presented. The performance of several detectors in the three operating modes of the Advanced Photon Source is systematically compared, with particular emphasis on asymmetric fill patterns. Several simple and well known correction formulas are evaluated. The results demonstrate the critical importance of detector speed and synchrotron fill pattern in selecting the proper dead-time correction.

43 PARTICLE ACCELERATORS↗

Probing Complexity using the Linac Coherent Light Source (LCLS) and the Advanced Light Source (ALS)

The goal of our research program is to investigate fundamental interactions between photons and molecular/nano-systems to advance our quantitative understanding of electron correlations, charge transfer and many body phenomena. Our research projects focus on probing, on a femtosecond time-scale, multi-electron interactions and tracing nuclear motion in order to understand, and ultimately control energy flow and charge transfer processes from electromagnetic radiation to matter. The experiments will be carried out with state of the art instrumentation built by the P.I. team with funds from a DoE "Single Investigator and Small Group Research" (SISGR) grant. The research projects carried out the past three years consisted of first experiments using the Linac Coherent Light Source (LCLS) x-ray free electron laser (FEL) facility at the SLAC National Laboratory, as well as the study of correlated processes in select anions using the Advanced Light Source (ALS). A report for the past cycle is described in section II. These studies have paved the way for our renewal application for the next three years. Our research interests for the next three years extend our past and present research by carrying out time-resolved measurements described in section III. They will consist of: a) The study of molecular dynamics that happen on ultrafast time scales, using pump-probe schemes and the study of non-linear physics in the x-ray regime via multi-photon absorption from the LCLS. This will be achieved by measuring and examining both electronic and nuclear dynamics subsequent to the interaction of molecules and nano-systems with LCLS pulses of various wavelength, intensity and pulse duration as described in section III.A. b) The study of molecular dynamics and correlated processes via absorption of vuv-soft x-rays from the Advanced Light Source (ALS) at Lawrence Berkeley Laboratory to provide single-photon ionization baseline results for LCLS studies. In addition, we will study the photodetachment of anions using the ALS as described in section III. B. The PI has an ALS approved program (AP) thus has guaranteed beamtime. Our research underpins several aspects of the DOE mission since our investigations of the formation and evolution of energized states in molecules and nanostructures provides a fundamental basis for understanding elementary processes in solar energy conversion and radiation-induced chemistry. Most of our work is carried out in a strong partnership with theorists. Our proposed work falls in the class of research reported to be timely and necessary by the 2013 DoE Basic Energy Sciences Advisory Committee (BESAC) Subcommittee report on Future X-ray Light Sources. Specifically, our proposed experiments fall in the category labeled class II, “Spectroscopy and Dynamics with FELs”.

74 ATOMIC AND MOLECULAR PHYSICS↗

Secondary Startup Neutron Sources as a Source of Tritium in a Pressurized Water Reactor (PWR) Reactor Coolant System (RCS)

The hypothesis of this paper is that the Zircaloy clad fuel source is minimal and that secondary startup neutron sources are the significant contributors of the tritium in the RCS that was previously assigned to release from fuel. Currently there are large uncertainties in the attribution of tritium in a Pressurized Water Reactor (PWR) Reactor Coolant System (RCS). The measured amount of tritium in the coolant cannot be separated out empirically into its individual sources. Therefore, to quantify individual contributors, all sources of tritium in the RCS of a PWR must be understood theoretically and verified by the sum of the individual components equaling the measured values.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗