Search NASA⌕ Search

SEARCH · Search NASA

Results for “sparse reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Seismic classification through sparse filter dictionaries

We tackle a multi-label classi cation problem involving the relation between acoustic- pro le features and the measured seismogram. To isolate components of the seismo- grams unique to each class of acoustic pro le we build dictionaries of convolutional lters. The convolutional- lter dictionaries for the individual classes are then combined into a large dictionary for the entire seismogram set. A given seismogram is classi ed by computing its representation in the large dictionary and then comparing reconstruction accuracy with this representation using each of the sub-dictionaries. The sub-dictionary with the minimal reconstruction error identi es the seismogram class.

58 GEOSCIENCES↗

Performance of Compact Pulsed Thermal Imaging System for In-Service Applications. Pulsed thermal tomography nondestructive examination of additively manufactured reactor materials and components

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of complex topology nuclear reactor parts from high-strength corrosion resistance alloys, such as stainless steel and Inconel. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which has the capability of melting metallic powder and net shaping the structures with relatively high precision. Some of the challenges with using LPBF method for nuclear manufacturing include the possibility of introducing pores into metallic structures. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures due to creep in high temperature nuclear reactor environment. Currently, there exist limited capabilities to evaluate actual AM structures nondestructively. Pulsed Thermography (PT) imaging provides a capability for non-destructive evaluation (NDE) of sub-surface defects in arbitrary size structures. The PT method is based on recording material surface temperature transients with infrared (IR) camera following thermal pulse delivered on material surface with flash light. The PT method has advantages for NDE of actual AM structures because the method involves one-sided non-contact measurements and fast processing of large sample areas captured in one image. The data cube of PT measurements consists of surface temperature taken at sequential time intervals T(x,y,t). Material defects can be detected either by analyzing the thermograms T(x,y,t) data cube, or by using thermal tomography (TT) algorithm to obtain 3D spatial reconstruction of thermal effusivity e(x,y,z). To reduce the cost and enable in-service NDE in spatially constrained environment, it is highly desirable to develop PT with compact and inexpensive IR camera. Following initial qualification of an AM component for deployment in a nuclear reactor, a compact PT system can also be used for in-service nondestructive evaluation (NDE) applications. However, data cube obtained with PT based on compact IR camera suffers from strong thermal noises and loss of features due to relatively low sampling rate. In this report we describe two unsupervised machine learning (ML) algorithms for enhancement of PT images obtained with compact IR camera. In one approach, we introduce Sparse Coding Discrete Cosine Transform (SC/DCT) algorithm to remove additive white Gaussian noise (AWGN) from spatial thermal effusivity reconstructions. In another approach we introduce a Spatial Temporal Denoised Thermal Source Separation (STDTSS) ML algorithm to process thermograms. The STDTSS algorithm consists of spatial and temporal denoising using Gaussian and Savitzky–Golay filtering, followed by the matrix decomposition using Principal Component Analysis (PCA), and Independent Component Analysis (ICA) to automatically detect flaws. In the work described in this report, we constructed a compact PT system using a relatively small and low-cost FLIR A65 camera, consisting on uncooled microbolometer detector. Performance of SC/DCT algorithm was demonstrated on enhancing TT images of Inconel 718 AM plate. Performance of the STDTSS methods was investigated using thermography data obtained from imaging stainless steel 316L specimens produced with LPBF method with imprinted calibrated porosity defects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Physics-informed neural networks for identification of material properties using standing waves

A metallic structure in its initial stage of failure involves plastic deformation or environmental degradation that changes the elastic modulus and density. This work presents the detection of change in wave velocity (a function of elastic modulus and density) as a system identification problem. A physics-informed neural network (PINN) is proposed to solve the system identification problem. The PINN takes the spatial coordinates of scanning locations and time as inputs and provides the displacement and wave velocity as outputs. The governing partial differential equation of standing waves in a rod is incorporated into the neural network as physics in the form of a loss function. The wave velocity vector is randomly initiated. During the training of the network, physics is used to determine and update the wave velocity target vector from the network’s displacement predictions. The measured data, comprising sparse displacement response on the rod structure, are used to train the PINN. The wave velocity at the sparse locations on the rod is learned from the predicted displacements during the training. Using the predictions of the trained network, the response of free vibration or material property variation can be reconstructed at unscanned locations on the structure to obtain high-resolution maps for full-field imaging to detect and localize the changes caused by plastic deformation. The PINN’s sparse scanning and simultaneous prediction capability during training can lead to high scanning and data-processing speeds. This capability yields a nondestructive evaluation system that can predict the presence of degraded material locations as the structural vibrations are scanned and processed in real time.

Rathod, Vivek↗

Tomographic imaging using poissonian detector data

An image reconstruction method for reconstructing a tomographic image (f.sub.j) of a region of investigation within an object (1), comprises the steps of providing detector data (y.sub.i) comprising Poisson random values measured at an i-th of a plurality of different positions, e.g. i=(k,l) with pixel index k on a detector device and angular index l referring to both the angular position (.alpha..sub.l) and the rotation radius (r.sub.l) of the detector device (10) relative to the object (1), providing a predetermined system matrix A.sub.ij assigning a j-th voxel of the object (1) to the i-th detector data (y.sub.i), and reconstructing the tomographic image (f.sub.j) based on the detector data (y.sub.i), said reconstructing step including a procedure of minimizing a functional F(f) depending on the detector data (y.sub.i) and the system matrix A.sub.ij and additionally including a sparse or compressive representation of the object (1) in an orthobasis T, wherein the tomographic image (f.sub.j) represents the global minimum of the functional F(f). Furthermore, an imaging method and an imaging device using the image reconstruction method are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First experimental study of multiple orientation muon tomography, with image optimization in sparse data environments

Due to the high penetrating power of cosmic ray muons, they can be used to probe very thick and dense objects. As charged particles, they can be tracked by ionization detectors, determining the position and direction of the muons. With detectors on either side of an object, particle direction changes can be used to extract scattering information within an object. This can be used to produce a scattering intensity image within the object related to density and atomic number. Such imaging is typically performed with a single detector-object orientation, taking advantage of the more intense downward flux of muons, producing planar imaging with some depth-of-field information in the third dimension. Several simulation studies have been published with multi-orientation tomography, which can form a three-dimensional representation faster than a single orientation view. In this work we present the first experimental multiple orientation muon tomography study. Experimental muon-scatter based tomography was performed using a concrete filled steel drum with several different metal wedges inside, between detector planes. Data was collected from different detector-object orientations by rotating the steel drum. The data collected from each orientation were then combined using two different tomographic methods. Results showed that using a combination of multiple depth-of-field reconstructions, rather than a traditional inverse Radon transform approach used for CT, resulted in more useful images for sparser data. As cosmic ray muon flux imaging is rate limited, the imaging techniques were compared for sparse data. Using the combined depth-of-field reconstruction technique, fewer detector-object orientations were needed to reconstruct images that could be used to differentiate the metal wedge compositions.

Applied Physics (physics.app-ph)↗

Characterization of Acoustic Emissions From Analogue Rocks Using Sparse Regression‐DMDc

Abstract Moisture loss in rock is known to generate acoustic emissions (AE). Phenomena that result in AE during drying are related to the movement of fluids through the pores and induced‐cracks that arise from differential mineral shrinkage, especially in clay‐bearing rock. AE from the movement of fluids occurs from the reconfiguration of fluid interfaces during drying, while AE from mineral shrinkage involves the debonding within or between minerals. Here, analogue rock samples were used to examine the differences in the AE signatures when one or both AE source‐types are present. An unsupervised sparse regression model, Dynamic Mode Decomposition with control, that extends Dynamic Mode Decomposition is used to characterize the AE signals recorded during the drying of porous analogue rock samples fabricated with ordinary Portland cement, with and without clay. This method can effectively and accurately reconstruct acoustic signals emitted from samples that only experience moisture loss without cracking. However, the method struggles to reconstruct signals from samples with intricate crack networks that formed during drying because AE generating mechanisms can emit contemporaneously, and the resulting waves propagate through drying‐induced cracks that can lead to multiple internal reflections. Thus, the differential reconstruction accuracy of time series generated by different underlying physical processes provides a robust filter for reducing large data catalogs. In general, both dynamics and sparse initiating events are learned directly from data and this method exposes a data hierarchy based on the complexity of the intrinsic dynamics.

58 GEOSCIENCES↗

Compressed sensing for phase contrast CT

Modern x-ray techniques opened the possibility to retrieve phase information. Phase-contrast computed tomography (PCCT) has the potential to significantly improve soft tissue contrast. Radiation dose, however, continues to be an issue when moving from bench to bedside. Dose reduction in this work is achieved by sparsely acquiring PCCT data. To compensate for appearing aliasing artifacts we introduce a compressed sensing (CS) reconstruction framework. We present the feasibility of CS on PCCT with numerical as well as measured phantom data. The results proof that CS compensates for under-sampling artifacts and maintains the superior soft tissue contrast and detail visibility in the reconstructed images.

60 APPLIED LIFE SCIENCES↗

Acoustic- and elastic-waveform inversion with total generalized p-variation regularization

Geophysical models usually contain both sharp interfaces and smooth variations, and it is difficult to accurately account for both of these two types of medium parameter variations using conventional full-waveform inversion methods. We develop a novel full-waveform inversion method for acoustic and elastic waves using a total generalized p-variation regularization scheme to address these challenging problems. We decompose the full-waveform inversion into two subproblems and solve these two minimization subproblems using an alternating-direction minimization strategy. One significant advantage of the total generalized p-variation regularization scheme is that it can simultaneously reconstruct sharp interfaces and smooth background variations of geophysical parameters. Such capability can also effectively suppress the noises in source-encoded inversion and sparse-data inversion, or inversion of noisy data. We demonstrate the advantages of our full-waveform inversion method using a checkerboard model, a modified elastic SEG/EAGE overthrust model, and a land field seismic data set. Our conclusions of synthetic and field seismic data demonstrate that our method reconstructs both smooth background variations and sharp interfaces of subsurface geophysical properties accurately, and provides a useful tool for accurate and reliable inversion of field seismic data.

58 GEOSCIENCES↗

Recovering fine details from under-resolved electron tomography data using higher order total variation ℓ 1 regularization

Over the last decade or so, reconstruction methods using ℓ 1 regularization, often categorized as compressed sensing (CS) algorithms, have significantly improved the capabilities of high fidelity imaging in electron tomography. The most popular ℓ 1 regularization approach within electron tomography has been total variation (TV) regularization. In addition to reducing unwanted noise, TV regularization encourages a piecewise constant solution with sparse boundary regions. In this paper we propose an alternative ℓ 1 regularization approach for electron tomography based on higher order total variation (HOTV). Like TV, the HOTV approach promotes solutions with sparse boundary regions. In smooth regions however, the solution is not limited to piecewise constant behavior. We demonstrate that this allows for more accurate reconstruction of a broader class of images – even those for which TV was designed for – particularly when dealing with pragmatic tomographic sampling patterns and very fine image features. In conclusion, we develop results for an electron tomography data set as well as a phantom example, and we also make comparisons with discrete tomography approaches.

47 OTHER INSTRUMENTATION↗

Compact video content representation for video coding using low multi-linear tensor rank approximation with dynamic core tensor order

Tensor is a multi-way representation of an entity that is widely used in many applications of mathematics and physics. The wide range of tensor algebra operations attract the researchers of graphical and vision field to identify unique methods for various applications such as segmentation, compression, indexing and so on. In this paper, low multi-linear rank approximation of a tensor is used for decomposition so as to perform compression on a video that is represented as a 4D tensor. Thus, the encoder has blocks for (1) multilinear rank approximation method so as to aid decomposition, (2) sparsity removal of residual data to reduce the required memory storage to a small level, (3) quantization on the sparse less residual data and (4) LZ77 dictionary coding for the video. The decoder uses a tensor reconstruction block along with residual error correction block that reduces loss/error in the reconstructed video. The size of core tensor is an important factor in rank approximation. It is identified at run time depending on the video contents. This size is determined adaptively using Tikhonov’s regularization method. The best value of core tensor size is identified with the corner of L-curve which preserves the video contents from heavy loss/error. Experimental results of the proposed work on comparison with H.264/AVC compression method indicate that the proposed method achieves up to 10% improvement in compression ratio with the least amount of loss and a maximum signal to noise ratio of 0.14. The proposed system gives better compression ratio than H.265 for videos with more number of frames without compromising quality.

97 MATHEMATICS AND COMPUTING↗

SU-E-I-41: Dictionary Learning Based Quantitative Reconstruction for Low-Dose Dual-Energy CT (DECT)

Purpose: DECT collects two sets of projection data under higher and lower energies. With appropriates composition methods on linear attenuation coefficients, quantitative information about the object, such as density, can be obtained. In reality, one of the important problems in DECT is the radiation dose due to doubled scans. This work is aimed at establishing a dictionary learning based reconstruction framework for DECT for improved image quality while reducing the imaging dose. Methods: In our method, two dictionaries were learned respectively from the high-energy and lowenergy image datasets of similar objects under normal dose in advance. The linear attenuation coefficient was decomposed into two basis components with material based composition method. An iterative reconstruction framework was employed. Two basis components were alternately updated with DECT datasets and dictionary learning based sparse constraints. After one updating step under the dataset fidelity constraints, both high-energy and low-energy images can be obtained from the two basis components. Sparse constraints based on the learned dictionaries were applied to the high- and low-energy images to update the two basis components. The iterative calculation continues until a pre-set number of iteration was reached. Results: We evaluated the proposed dictionary learning method with dual energy images collected using a DECT scanner. We re-projected the projection data with added Poisson noise to reflect the low-dose situation. The results obtained by the proposed method were compared with that obtained using FBP based method and TV based method. It was found that the proposed approach yield better results than other methods with higher resolution and less noise. Conclusion: The use of dictionary learned from DECT images under normal dose is valuable and leads to improved results with much lower imaging dose.

60 APPLIED LIFE SCIENCES↗

Subsurface Grain Morphology Reconstruction by Differential Aperture X-ray Microscopy

A multistep, non-destructive grain morphology reconstruction methodology that is applicable to near-surface volumes is developed and tested on synthetic grain structures. This approach probes the subsurface crystal orientation using differential aperture x-ray microscopy on a sparse grid across the microstructure volume of interest. Resulting orientation data are clustered according to proximity in physical and orientation space and used as seed points for an initial Voronoi tessellation to (crudely) approximate the grain morphology. Curvature-driven grain boundary relaxation, simulated by means of the Voronoi implicit interface method, progressively improves the reconstruction accuracy. The similarity between bulk and readily accessible surface reconstruction error provides an objective termination criterion for boundary relaxation.

36 MATERIALS SCIENCE↗

Pan-Pacific low-frequency modes of sea level and climate variability

Tide gauges provide a long observational record that can inform the nature of satellite-era basin-scale sea level trends. However, common signals must be extracted from geographically sparse records. Here, by applying low-frequency component analysis (LFCA) to tide gauge records and surface climate reconstructions, we isolate three coherent modes of Pacific Ocean variability that we ascribe to: a secular, greenhouse gas–driven climate change (LFC1); a nonlinear mode of variability with a reversal around 1980, potentially linked to aerosols (LFC2); and the Interdecadal Pacific Oscillation (LFC3). Although sea level trend patterns reflect the superimposed contribution of all modes, satellite-era trends are dominated by an increasing phase of LFC2: They are thus potentially unrepresentative of both longer-term historical patterns and those expected in the future.

Science & Technology - Other Topics↗

Advanced radiometric and interferometric milimeter-wave scene simulations

Smart munitions and weapons utilize various imaging sensors (including passive IR, active and passive millimeter-wave, and visible wavebands) to detect/identify targets at short standoff ranges and in varied terrain backgrounds. In order to design and evaluate these sensors under a variety of conditions, a high-fidelity scene simulation capability is necessary. Such a capability for passive millimeter-wave scene simulation exists at TRW. TRW's Advanced Radiometric Millimeter-Wave Scene Simulation (ARMSS) code is a rigorous, benchmarked, end-to-end passive millimeter-wave scene simulation code for interpreting millimeter-wave data, establishing scene signatures and evaluating sensor performance. In passive millimeter-wave imaging, resolution is limited due to wavelength and aperture size. Where high resolution is required, the utility of passive millimeter-wave imaging is confined to short ranges. Recent developments in interferometry have made possible high resolution applications on military platforms. Interferometry or synthetic aperture radiometry allows the creation of a high resolution image with a sparsely filled aperture. Borrowing from research work in radio astronomy, we have developed and tested at TRW scene reconstruction algorithms that allow the recovery of the scene from a relatively small number of spatial frequency components. In this paper, the TRW modeling capability is described and numerical results are presented.

Hauss, B. I.↗

TH-AB-209-09: Quantitative Imaging of Electrical Conductivity by VHF-Induced Thermoacoustics

Purpose: To demonstrate that very high frequency (VHF) induced thermoacoustics has the potential to provide quantitative images of electrical conductivity in Siemens/meter, much as shear wave elastography provides tissue stiffness in kPa. Quantitatively imaging a large organ requires exciting thermoacoustic pulses throughout the volume and broadband detection of those pulses because tomographic image reconstruction preserves frequency content. Applying the half-wavelength limit to a 200-micron inclusion inside a 7.5 cm diameter organ requires measurement sensitivity to frequencies ranging from 4 MHz down to 10 kHz, respectively. VHF irradiation provides superior depth penetration over near infrared used in photoacoustics. Additionally, VHF signal production is proportional to electrical conductivity, and prostate cancer is known to suppress electrical conductivity of prostatic fluid. Methods: A dual-transducer system utilizing a P4-1 array connected to a Verasonics V1 system augmented by a lower frequency focused single element transducer was developed. Simultaneous acquisition of VHF-induced thermoacoustic pulses by both transducers enabled comparison of transducer performance. Data from the clinical array generated a stack of 96-images with separation of 0.3 mm, whereas the single element transducer imaged only in a single plane. In-plane resolution and quantitative accuracy were measured at isocenter. Results: The array provided volumetric imaging capability with superior resolution whereas the single element transducer provided superior quantitative accuracy. Combining axial images from both transducers preserved resolution of the P4-1 array and improved image contrast. Neither transducer was sensitive to frequencies below 50 kHz, resulting in a DC offset and low-frequency shading over fields of view exceeding 15 mm. Fresh human prostates were imaged ex vivo and volumetric reconstructions reveal structures rarely seen in diagnostic images. Conclusion: Quantitative whole-organ thermoacoustic tomography will be feasible by sparsely interspersing transducer elements sensitive to the low end of the ultrasonic range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A robust real-time surface reconstruction method on point clouds captured from a 3D surface photogrammetry system

Purpose: To develop a robust and real-time surface reconstruction method on point clouds captured from a 3D surface photogrammetry system. Methods: The authors have developed a robust and fast surface reconstruction method on point clouds acquired by the photogrammetry system, without explicitly solving the partial differential equation required by a typical variational approach. Taking advantage of the overcomplete nature of the acquired point clouds, their method solves and propagates a sparse linear relationship from the point cloud manifold to the surface manifold, assuming both manifolds share similar local geometry. With relatively consistent point cloud acquisitions, the authors propose a sparse regression (SR) model to directly approximate the target point cloud as a sparse linear combination from the training set, assuming that the point correspondences built by the iterative closest point (ICP) is reasonably accurate and have residual errors following a Gaussian distribution. To accommodate changing noise levels and/or presence of inconsistent occlusions during the acquisition, the authors further propose a modified sparse regression (MSR) model to model the potentially large and sparse error built by ICP with a Laplacian prior. The authors evaluated the proposed method on both clinical point clouds acquired under consistent acquisition conditions and on point clouds with inconsistent occlusions. The authors quantitatively evaluated the reconstruction performance with respect to root-mean-squared-error, by comparing its reconstruction results against that from the variational method. Results: On clinical point clouds, both the SR and MSR models have achieved sub-millimeter reconstruction accuracy and reduced the reconstruction time by two orders of magnitude to a subsecond reconstruction time. On point clouds with inconsistent occlusions, the MSR model has demonstrated its advantage in achieving consistent and robust performance despite the introduced occlusions. Conclusions: The authors have developed a fast and robust surface reconstruction method on point clouds captured from a 3D surface photogrammetry system, with demonstrated sub-millimeter reconstruction accuracy and subsecond reconstruction time. It is suitable for real-time motion tracking in radiotherapy, with clear surface structures for better quantifications.

60 APPLIED LIFE SCIENCES↗

Deep Learning for Simultaneous Inference of Hydraulic and Transport Properties

Abstract Identification of a heterogeneous conductivity field and reconstruction of a contaminant release history are key aspects of subsurface remediation. These two goals are achieved by combining model predictions with sparse and noisy hydraulic head and concentration measurements. Solution of this inverse problem is notoriously difficult due to, in part, high dimensionality of the parameter space and high computational cost of repeated forward solves. We use a convolutional adversarial autoencoder (CAAE) to parameterize a heterogeneous non‐Gaussian conductivity field via a low‐dimensional latent representation. A three‐dimensional dense convolutional encoder‐decoder (DenseED) network serves as a forward surrogate of the flow and transport model. The CAAE‐DenseED surrogate is fed into the ensemble smoother with multiple data assimilation (ESMDA) algorithm to sample from the Bayesian posterior distribution of the unknown parameters, forming a CAAE‐DenseED‐ESMDA inversion framework. The resulting CAAE‐DenseED‐ESMDA inversion strategy is used to identify a three‐dimensional contaminant source and conductivity field. A comparison of the inversion results from CAAE‐ESMDA with physical flow and transport simulator and from CAAE‐DenseED‐ESMDA shows that the latter yields accurate reconstruction results at the fraction of the computational cost of the former.

Zhou, Zitong↗

Sparse Bayesian mass mapping with uncertainties: hypothesis testing of structure

ABSTRACT A crucial aspect of mass mapping, via weak lensing, is quantification of the uncertainty introduced during the reconstruction process. Properly accounting for these errors has been largely ignored to date. We present a new method to reconstruct maximum a posteriori (MAP) convergence maps by formulating an unconstrained Bayesian inference problem with Laplace-type l1-norm sparsity-promoting priors, which we solve via convex optimization. Approaching mass mapping in this manner allows us to exploit recent developments in probability concentration theory to infer theoretically conservative uncertainties for our MAP reconstructions, without relying on assumptions of Gaussianity. For the first time, these methods allow us to perform hypothesis testing of structure, from which it is possible to distinguish between physical objects and artefacts of the reconstruction. Here, we present this new formalism, and demonstrate the method on simulations, before applying the developed formalism to two observational data sets of the Abell 520 cluster. Initial reconstructions of the Abell 520 catalogues reported the detection of an anomalous ‘dark core’ – an overdense region with no optical counterpart – which was taken to be evidence for self-interacting dark matter. In our Bayesian framework, it is found that neither Abell 520 data set can conclusively determine the physicality of such dark cores at $99{{\ \rm per\ cent}}$ confidence. However, in both cases the recovered MAP estimators are consistent with both sets of data.

Price, M. A.↗