Search NASA⌕ Search

SEARCH · Search NASA

Results for “steam data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Energy Requirements for Integration of Nuclear Reactors with Iron and Steel Plants

This report identifies energy needs of heavy energy users within the domestic iron and steel industry and suggests solutions for integrating nuclear energy. The iron and steel industry, composed of several types of plants which perform different processes with varied energy demands and vectors, is a heavy consumer of electric power and fossil fuels including coke and natural gas. Almost all major process temperatures exceed the temperatures of direct heat available from advanced reactors, and so electricity and hydrogen were considered instead. Reference units were adopted and estimated energy demands computed for the blast furnace (BF), direct reduced iron (DRI) unit, electric arc furnace (EAF), and reheat furnaces. By utilizing production capacity data from industry reports, the ranges of power demands were estimated, including for hydrogen production by high temperature steam electrolysis (HTSE). For the EAF and DRI unit, more detailed integration studies with thermodynamic modeling were also conducted and determined a possible solution with a specific reactor design and number of modules. Furthermore, because many unit processes are co-located, entire plants were considered by adding the energy demands of the unit processes to form four hypothetical reference plants. The range of power needs for the reference plants is compatible with multi-unit banks of microreactors at the low end, and would create a need for multiple larger-capacity SMRs at the high end (1 GWe plus 0.14 GWt). Although the overall power need at the high end is well-matched with one present-day large reactor offering (1.1 GWe), redundancy considerations may require a minimum of two reactors, potentially eliminating the single large reactor from consideration. Auxiliary or house loads would increase the reference plant estimates. Finally, the report provides total estimated energy needs under integration of all U.S. units of each process (BF, DRI, EAF, and reheat furnaces), representing a national potential for nuclear energy in the industry. U.S. iron and steel plants may be candidates for integration with nuclear reactors via electricity and hydrogen, and many sites have energy requirements that correspond well to the capacities of several advanced nuclear power designs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Multicomponent Equilibrium Models for Testing Geothermometry Approaches

Geothermometry is an important tool for estimating deep reservoir temperature from the geochemical composition of shallower and cooler waters. The underlying assumption of geothermometry is that the waters collected from shallow wells and seeps maintain a chemical signature that reflects equilibrium in the deeper reservoir. Many of the geothermometers used in practice are based on correlation between water temperatures and composition or using thermodynamic calculations based a subset (typically silica, cations or cation ratios) of the dissolved constituents. An alternative approach is to use complete water compositions and equilibrium geochemical modeling to calculate the degree of disequilibrium (saturation index) for large number of potential reservoir minerals as a function of temperature. We have constructed several “forward” geochemical models using The Geochemist’s Workbench to simulate the change in chemical composition of reservoir fluids as they migrate toward the surface. These models explicitly account for the formation (mass and composition) of a steam phase and equilibrium partitioning of volatile components (e.g., CO2, H2S, and H2) into the steam as a result of pressure decreases associated with upward fluid migration from depth. We use the synthetic data generated from these simulations to determine the advantages and limitations of various geothermometry and optimization approaches for estimating the likely conditions (e.g., temperature, pCO2) to which the water was exposed in the deep subsurface. We demonstrate the magnitude of errors that can result from boiling, loss of volatiles, and analytical error from sampling and instrumental analysis. The estimated reservoir temperatures for these scenarios are also compared to conventional geothermometers. These results can help improve estimation of geothermal resource temperature during exploration and early development.

15 GEOTHERMAL ENERGY↗

Performance of the Spacecraft Propulsion Research Facility During Altitude Firing Tests of the Delta 3 Upper Stage

The Spacecraft Propulsion Research Facility at the NASA Lewis Research Center's Plum Brook Station was reactivated in order to conduct flight simulation ground tests of the Delta 3 cryogenic upper stage. The tests were a cooperative effort between The Boeing Company, Pratt and Whitney, and NASA. They included demonstration of tanking and detanking of liquid hydrogen, liquid oxygen and helium pressurant gas as well as 12 engine firings simulating first, second, and third burns at altitude conditions. A key to the success of these tests was the performance of the primary facility systems and their interfaces with the vehicle. These systems included the structural support of the vehicle, propellant supplies, data acquisition, facility control systems, and the altitude exhaust system. While the facility connections to the vehicle umbilical panel simulated the performance of the launch pad systems, additional purge and electrical connections were also required which were unique to ground testing of the vehicle. The altitude exhaust system permitted an approximate simulation of the boost-phase pressure profile by rapidly pumping the test chamber from 13 psia to 0.5 psia as well as maintaining altitude conditions during extended steady-state firings. The performance of the steam driven ejector exhaust system has been correlated with variations in cooling water temperature during these tests. This correlation and comparisons to limited data available from Centaur tests conducted in the facility from 1969-1971 provided insight into optimizing the operation of the exhaust system for future tests. Overall, the facility proved to be robust and flexible for vehicle space simulation engine firings and enabled all test objectives to be successfully completed within the planned schedule.

Meyer, Michael L.↗

Machine-Learning Analysis of Moisture Carryover in Boiling Water Reactors

Moisture carryover (MCO) is modeled in the General Electric Type-4 boiling water reactor (BWR) using machine-learning methods and data from operating plants. Understanding MCO and the conditions that give rise to an elevated value is important since excessive MCO can damage critical turbine components, can result in elevated dose levels to on-site personnel, and can interfere with late-cycle power management. The analysis of MCO takes into account simplifying reactor symmetries and important geometric dependencies. The plant data are taken from several reactors and were collected over multiple years and multiple fuel cycles. A brief description of the origin of MCO in U.S. BWR plants is given. A machine-learning model is constructed from the data using applicable algorithms and data-reduction techniques. Matching model complexity with available data is one of the more challenging machine-learning tasks. Too many features and too little data will lead to overfitting. The data for each fuel cycle included over 6876 original features, 9 for each fuel bundle. Two approaches are used to reduce the data set into a manageable number of features. The first was an engineering analysis that resulted in the selection of steam quality Q and steam liquid phase velocity V L as the main features driving MCO. Using a Q and a V L for each fuel bundle gives 1528 Q and a V L feature describing the reactor behavior. An analysis of different functional forms of these two variables led to the actual inputs to the neural network model. The second approach involved the use of statistical techniques such as Pearson’s correlation and k-means analysis. The identified groupings of bundles behaved similarly. Treating each grouping as a single feature further reduced the input variable set to a manageable number. Here, a model selection criterion is proposed, and results are presented along with a discussion of related issues.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effect of sodium loading on Pt/ZrO 2 during ethanol steam reforming

Ethanol steam reforming (ESR) was investigated on unpromoted and several sodium promoted Pt/ZrO 2 catalysts. From DRIFTS experiments, the following steps during ESR were inferred: dissociation of ethanol to produce ethoxy species; oxidative dehydrogenation of ethoxy species to acetate; and acetate decomposition. Acetate decomposition depends on the catalyst formulation. Decarboxylation is the most favored route at high sodium loading (2.5 and 5 wt.%); acetate decomposes in the forward direction to CH 4 and a carbonate, which further decomposes to CO 2 . In contrast, decarbonylation is prevalent for the unpromoted catalyst or catalysts having low sodium loading. Furthermore, acetate likely decomposes to CH 3 OH and CO. Adsorbed methanol may undergo further steam reforming by oxidative dehydrogenation to formate species, which decarbonylates via reverse decomposition to CO and H 2 O. Temperature programmed desorption/reaction and activity data confirmed that alkali promotion, especially at 1.8 %Na and higher loading, facilitates the forward acetate decomposition step, favoring decarboxylation over decarbonylation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Capabilities Development for Transient Testing of Advanced Nuclear Fuels at TREAT

The TREAT facility is a unique capability at the Idaho National Laboratory currently being prepared for resumption of nuclear transient testing. Accordingly, designs for several transient irradiation tests are being pursued to enable development of advanced nuclear fuels and materials. In addition to the reactor itself, the foundation for TREAT’s capabilities also include a suite of irradiation vehicles and supporting infrastructure to provide the desired specimen boundary conditions while supporting a variety of instrumentation needs. The challenge of creating these vehicles, especially since many of the modern data needs were not historically addressed in TREAT experiment vehicles, has necessitated a sizeable engineering effort. This effort is currently underway and maturing rapidly. This paper summarizes the status, future plans, and rationale for TREAT experiment vehicle capabilities. Much of the current progress is focused around understanding and demonstrating the behavior of fuel design with enhanced accident tolerance in water-cooled reactors. Additionally, several related efforts are underway to facilitate transient testing in liquid sodium, inert gas, and steam environments. This paper discusses why such a variety of capabilities are needed, outlines plans to accomplish them, and describes the relationship between transient data needs and the irradiation hardware that will support the gathering of this information.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simulation of a main steam line break with steam generator tube rupture using trace

A simulation of the OECD/NEA ROSA-2 Project Test 5 was made with the thermal-hydraulic code TRACE5. Test 5 performed in the Large Scale Test Facility (LSTF) reproduced a Main Steam Line Break (MSLB) with a Steam Generator Tube Rupture (SGTR) in a Pressurized Water Reactor (PWR). The result of these simultaneous breaks is a depressurization in the secondary and primary system in loop B because both systems are connected through the SGTR. Good approximation was obtained between TRACE5 results and experimental data. TRACE5 reproduces qualitatively the phenomena that occur in this transient: primary pressure falls after the break, stagnation of the pressure after the opening of the relief valve of the intact steam generator, the pressure falls after the two openings of the PORV and the recovery of the liquid level in the pressurizer after each closure of the PORV. Furthermore, a sensitivity analysis has been performed to know the effect of varying the High Pressure Injection (HPI) flow rate in both loops on the system pressures evolution. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Slag monitoring system for combustion chambers of steam boilers

The computer-based boiler performance system presented in this article has been developed to provide a direct and quantitative assessment of furnace and convective surface cleanliness. Temperature, pressure, and flow measurements and gas analysis data are used to perform heat transfer analysis in the boiler furnace and evaporator. Power boiler efficiency is calculated using an indirect method. The on-line calculation of the exit flue gas temperature in a combustion chamber allows for an on-line heat flow rate determination, which is transferred to the boiler evaporator. Based on the energy balance for the boiler evaporator, the superheated steam mass flow rate is calculated taking into the account water flow rate in attemperators. Comparing the calculated and the measured superheated steam mass flow rate, the effectiveness of the combustion chamber water walls is determined in an on-line mode. Soot-blower sequencing can be optimized based on actual cleaning requirements rather than on fixed time cycles contributing to lowering of the medium usage in soot blowers and increasing of the water-wall lifetime.

20 FOSSIL-FUELED POWER PLANTS↗

Coal properties and system operating parameters for underground coal gasification

Through the model experiment for underground coal gasification, the influence of the properties for gasification agent and gasification methods on underground coal gasifier performance were studied. The results showed that pulsating gasification, to some extent, could improve gas quality, whereas steam gasification led to the production of high heating value gas. Oxygen-enriched air and backflow gasification failed to improve the quality of the outlet gas remarkably, but they could heighten the temperature of the gasifier quickly. According to the experiment data, the longitudinal average gasification rate along the direction of the channel in the gasifying seams was 1.212 m/d, with transverse average gasification rate 0.069 m/d. Experiment indicated that, for the oxygen-enriched steam gasification, when the steam/oxygen ratio was 2:1, gas compositions remained stable, with H{sub 2} + CO content virtually standing between 60% and 70% and O{sub 2} content below 0.5%. The general regularities of the development of the temperature field within the underground gasifier and the reasons for the changes of gas quality were also analyzed. The 'autopneumatolysis' and methanization reaction existing in the underground gasification process were first proposed.

01 COAL, LIGNITE, AND PEAT↗

Behind the Meter Solar+Storage: Market data and trends [Slides]

As the distributed solar market evolves toward more dynamic forms of deployment, interest in paired solar-plus-storage applications continues to gain steam, but details on the current state of the market are relatively sparse. To fill that void, Berkeley Lab has released an in-depth analysis of this budding market segment. This report draws on the Lab’s Tracking the Sun dataset to characterize trends in deployment, system sizing and equipment selection, installer-market development, and system pricing. The report also provides indicative analyses of the financial and resilience value that host customers in several key markets presently receive by pairing storage with solar.

14 SOLAR ENERGY↗

Development of a plant-wide dynamic model of an integrated gasification combined cycle (IGCC) plant

In this presentation, development of a plant-wide dynamic model of an advanced Integrated Gasification Combined Cycle (IGCC) plant with CO2 capture will be discussed. The IGCC reference plant generates 640 MWe of net power using Illinois No.6 coal as the feed. The plant includes an entrained, downflow, General Electric Energy (GEE) gasifier with a radiant syngas cooler (RSC), a two-stage water gas shift (WGS) conversion process, and two advanced 'F' class combustion turbines partially integrated with an elevated-pressure air separation unit (ASU). A subcritical steam cycle is considered for heat recovery steam generation. Syngas is selectively cleaned by a SELEXOL acid gas removal (AGR) process. Sulfur is recovered using a two-train Claus unit with tail gas recycle to the AGR. A multistage intercooled compressor is used for compressing CO2 to the pressure required for sequestration. Using Illinois No.6 coal, the reference plant generates 640 MWe of net power. The plant-wide steady-state and dynamic IGCC simulations have been generated using the Aspen Plus{reg_sign} and Aspen Plus Dynamics{reg_sign} process simulators, respectively. The model is generated based on the Case 2 IGCC configuration detailed in the study available in the NETL website1. The GEE gasifier is represented with a restricted equilibrium reactor model where the temperature approach to equilibrium for individual reactions can be modified based on the experimental data. In this radiant-only configuration, the syngas from the Radiant Syngas Cooler (RSC) is quenched in a scrubber. The blackwater from the scrubber bottom is further cleaned in the blackwater treatment plant. The cleaned water is returned back to the scrubber and also used for slurry preparation. The acid gas from the sour water stripper (SWS) is sent to the Claus plant. The syngas from the scrubber passes through a sour shift process. The WGS reactors are modeled as adiabatic plug flow reactors with rigorous kinetics based on the mid-life activity of the shift-catalyst. The SELEXOL unit consists of the H2S and CO2 absorbers that are designed to meet the stringent environmental limits and requirements of other associated units. The model also considers the stripper for recovering H2S that is sent as a feed to a split-flow Claus unit. The tail gas from the Claus unit is recycled to the SELEXOL unit. The cleaned syngas is sent to the GE 7FB gas turbine. This turbine is modeled as per published data in the literature. Diluent N2 is used from the elevated-pressure ASU for reducing the NOx formation. The heat recovery steam generator (HRSG) is modeled by considering generation of high-pressure, intermediate-pressure, and low-pressure steam. All of the vessels, reactors, heat exchangers, and the columns have been sized. The basic IGCC process control structure has been synthesized by standard guidelines and existing practices. The steady-state simulation is solved in sequential-modular mode in Aspen Plus{reg_sign} and consists of more than 300 unit operations, 33 design specs, and 16 calculator blocks. The equation-oriented dynamic simulation consists of more than 100,000 equations solved using a multi-step Gear's integrator in Aspen Plus Dynamics{reg_sign}. The challenges faced in solving the dynamic model and key transient results from this dynamic model will also be discussed.

97 MATHEMATICS AND COMPUTING↗

Morphological changes in the cellulose and lignin components of biomass occur at different stages of steam pretreatment

Morphological changes to the different components of lignocellulosic biomass were observed as they occurred during steam pretreatment by placing a pressure reaction cell in a neutron beam and collecting time-resolved neutron scattering data. Changes to cellulose morphology occurred mainly in the heating phase, whereas changes in lignin morphology occurred mainly in the holding and cooling phases. During the heating stage, water is irreversibly expelled from cellulose microfibrils as the elementary fibrils coalesce. During the holding phase lignin aggregates begin to appear and they increase in size most noticeably during the cooling phase. This experiment demonstrates the unique information that in situ small angle neutron scattering studies of pretreatment can provide. This approach is potentially useful in optimizing the heating, holding and cooling stages of pretreatments to allow the exact size and nature of lignin aggregates to be controlled in order to enhance enzyme accessibility to cellulose and therefore the efficiency of biomass conversion.

09 BIOMASS FUELS↗

An Information Theoretic Framework and Self-organizing Agent- based Sensor Network Architecture for Power Plant Condition Monitoring

A central goal of the work was to enable both the extraction of all relevant information from sensor data, and the application of information gained from appropriate processing and fusion at the system level to operational control and decision-making at various levels of the control hierarchy through: 1. Exploiting the deep connection between information theory and the thermodynamic formalism, 2. Deployment using distributed intelligent agents with testing and validation in a hardware-in-the loop simulation environment. Enterprise architectures are the organizing logic for key business processes and IT infrastructure and, while the generality of current definitions provides sufficient flexibility, the current architecture frameworks do not inherently provide the appropriate structure. Of particular concern is that existing architecture frameworks often do not make a distinction between ``data'' and ``information.'' This work defines an enterprise architecture for health and condition monitoring of power plant equipment and further provides the appropriate foundation for addressing shortcomings in current architecture definition frameworks through the discovery of the information connectivity between the elements of a power generation plant. That is, to identify the correlative structure between available observations streams using informational measures. The principle focus here is on the implementation and testing of an emergent, agent-based, algorithm based on the foraging behavior of ants for eliciting this structure and on measures for characterizing differences between communication topologies. The elicitation algorithms are applied to data streams produced by a detailed numerical simulation of Alstom’s 1000 MW ultra-super-critical boiler and steam plant. The elicitation algorithm and topology characterization can be based on different informational metrics for detecting connectivity, e.g. mutual information and linear correlation.

20 FOSSIL-FUELED POWER PLANTS↗

Techno-Economic Analysis of Product Diversification Options for Sustainability of the Monticello and Prairie Island Nuclear Power Plants

The objective of this work was to perform techno-economic analysis (TEA) of hybrid options that could be integrated with light water reactor (LWR) nuclear power plants (NPPs) in order to improve the viability and sustainability of existing LWRs through product diversification by utilizing nuclear energy not only to produce grid electricity but to also produce carbon free products such as hydrogen, ammonia or synthetic fuels. Much of the analysis herein could be generally applied to any LWR (high temperature steam electrolysis- HTSE design), but hydrogen demand and the optimization of the HTSE was completed with specific collaboration and data from Xcel Energy’s Prairie Island and Monticello nuclear generating stations and the surrounding market and logistics potential in the greater Minneapolis region. Xcel Energy has set aggressive goals with regards to decarbonization, including an 80% reduction in CO 2 emissions from 2005 levels, by 2030 and 100% carbon free by 2050. Other TEAs regarding hydrogen production with nuclear energy have been completed in collaboration with other utility companies previously. Besides being the first TEA in this regard specific to Xcel Energy and the surrounding markets and logistics, this TEA adds to the previously completed TEAs by providing the most up to date and state of the art analysis and optimization of the hydrogen production plant integrated with nuclear power (NPP-HTSE).

08 HYDROGEN↗

Comparison of Simultaneous PIV and Hydroxyl Tagging Velocimetry in Low Velocity Flows

Hydroxyl tagging velocimetry (HTV) is a molecular tagging velocimetry (MTV) technique that relies on the photo- dissociation of water vapor into OH radicals and their subsequent tracking using laser-induced fluorescence. At ambient temperature in air, the OH species lifetime is about 50 micro-s. The feasibility of using HTV for probing low- speed flows (a few m/s) is investigated by using an inert, heated gas as a means to increase the OH species lifetime. Unlike particle-based techniques, MTV does not suffer from tracer settling, which is particularly problematic at low speeds. Furthermore, the flow needs to be seeded with only a small mole fraction of water vapor, making it safer for both the user and facilities than other MTV techniques based on corrosive or toxic chemical tracers. HTV is demonstrated on a steam-seeded nitrogen jet at approximately 75 C in the laminar (Umean=3.31 m/s, Re=1,540), transitional (Umean=4.48 m/s, Re=2,039), and turbulent (Umean=6.91 m/s, Re=3,016) regimes at atmospheric pressure. The measured velocity profiles are compared with particle image velocimetry (PIV) measurements performed simultaneously with a second imager. Seeding for the PIV is achieved by introducing micron-sized water droplets into the flow with the steam; the same laser sheet is used for PIV and HTV to guarantee spatial and temporal overlap of the data. Optimizing each of these methods, however, requires conflicting operating conditions: higher temperatures benefit the HTV signals but reduce the available seed density for the PIV through evaporation. Nevertheless, data are found to agree within 10% for the instantaneous velocity profiles and within 5% for the mean profiles and demonstrate the feasibility of HTV for low-speed flows at moderate to high temperatures.

Andre, Matthieu A.↗

Rigorous Kinetic Modeling and Optimization Study of a Modified Claus Unit for an Integrated Gasification Combined Cycle (IGCC) Power Plant with CO{sub 2} Capture

The modified Claus process is one of the most common technologies for sulfur recovery from acid gas streams. Important design criteria for the Claus unit, when part of an Integrated Gasification Combined Cycle (IGCC) power plant, are the ability to destroy ammonia completely and the ability to recover sulfur thoroughly from a relatively low purity acid gas stream without sacrificing flame stability. Because of these criteria, modifications to the conventional process are often required, resulting in a modified Claus process. For the studies discussed here, these modifications include the use of a 95% pure oxygen stream as the oxidant, a split flow configuration, and the preheating of the feeds with the intermediate pressure steam generated in the waste heat boiler (WHB). In the future, for IGCC plants with CO{sub 2} capture, the Claus unit must satisfy emission standards without sacrificing the plant efficiency in the face of typical disturbances of an IGCC plant, such as rapid change in the feed flow rates due to load-following and wide changes in the feed composition because of changes in the coal feed to the gasifier. The Claus unit should be adequately designed and efficiently operated to satisfy these objectives. Even though the Claus process has been commercialized for decades, most papers concerned with the modeling of the Claus process treat the key reactions as equilibrium reactions. Such models are validated by manipulating the temperature approach to equilibrium for a set of steady-state operating data, but they are of limited use for dynamic studies. One of the objectives of this study is to develop a model that can be used for dynamic studies. In a Claus process, especially in the furnace and the WHB, many reactions may take place. In this work, a set of linearly independent reactions has been identified, and kinetic models of the furnace flame and anoxic zones, WHB, and catalytic reactors have been developed. To facilitate the modeling of the Claus furnace, a four-stage method was devised so as to determine which set of linearly independent reactions would best describe the product distributions from available plant data. Various approaches are taken to derive the kinetic rate expressions, which are either missing in the open literature or found to be inconsistent. A set of plant data is used for optimal estimation of the kinetic parameters. The final model agrees well with the published plant data. Using the developed kinetics models of the Claus reaction furnace, WHB, and catalytic stages, two optimization studies are carried out. The first study shows that there exists an optimal steam pressure generated in the WHB that balances hydrogen yield, oxygen demand, and power generation. In the second study, it is shown that an optimal H{sub 2}S/SO{sub 2} ratio exists that balances single-pass conversion, hydrogen yield, oxygen demand, and power generation. In addition, an operability study has been carried out to examine the operating envelope in which both the H{sub 2}S/SO{sub 2} ratio and the adiabatic flame temperature can be controlled in the face of disturbances typical for the operation of an IGCC power plant with CO{sub 2} capture. Impact of CO{sub 2} capture on the Claus process has also been discussed.

20 FOSSIL-FUELED POWER PLANTS↗

Solvation and Acid Strength Effects on Catalysis by Faujasite Zeolites

Kinetic, spectroscopic, and chemical titration data indicate that differences in monomolecular isobutane cracking and dehydrogenation and methanol dehydration turnover rates (per H+) among FAU zeolites treated thermally with steam (H-USY) and then chemically with ammonium hexafluorosilicate (CDHUSY) predominantly reflect differences in the size and solvating properties of their supercage voids rather than differences in acid strength. The number of protons on a given sample was measured consistently by titrations with Na+, with CH3 groups via reactions of dimethyl ether, and with 2,6-di-tert-butylpyridine during methanol dehydration catalysis; these titration values were also supported by commensurate changes in acidic OH infrared band areas upon exposure to titrant molecules. The number of protons, taken as the average of the three titration methods, was significantly smaller than the number of framework Al atoms (Alf) obtained from X-ray diffraction and 27Al magic angle spinning nuclear magnetic resonance spectroscopy on H-USY (0.35 H+/Alf) and CD-HUSY (0.69 H+/Alf). These data demonstrate that the ubiquitous use of Alf sites as structural proxies for active H+ sites in zeolites can be imprecise, apparently because distorted Al structures that are not associated with acidic protons are sometimes detected as Alf sites. Monomolecular isobutane cracking and dehydrogenation rate constants, normalized non-rigorously by the number of Alf species, decreased with increasing Na+ content on both H-USY and CD-HUSY samples and became undetectable at sub-stoichiometric exchange levels (0.32 and 0.72 Na+/Alf ratios, respectively), an unexpected finding attributed incorrectly in previous studies to the presence of minority ‘‘super-acidic’’ sites. These rate constants, when normalized rigorously by the number of residual H+ sites were independent of Na+ content on both H-USY and CD-HUSY samples, reflecting the stoichiometric replacement of protons that are uniform in reactivity by Na+ cations. Monomolecular isobutane cracking and dehydrogenation rate constants (per H+; 763 K), however, were higher on H-USY than CD-HUSY (by a factor of 1.4). Equilibrium constants for the formation of protonated methanol dimers via adsorption of gaseous methanol onto adsorbed methanol monomers, determined from kinetic studies of methanol dehydration to dimethyl ether (433 K), were also higher on H-USY than CD-HUSY (by a factor of 2.1). These larger constants predominantly reflect stronger dispersive interactions in H-USY, consistent with its smaller supercage voids that result from the occlusion of void space by extraframework Al (Alex) residues. These findings appear to clarify enduring controversies about the mechanistic interpretation of the effects of Na+ and Alex species on the catalytic reactivity of FAU zeolites. They also illustrate the need to normalize rates by the number of active sites instead of more convenient but less accurate structural proxies for such sites.

Environmental Molecular Sciences Laboratory↗

RADIATIVE PROPERTY MEASUREMENTS OF OXY-FUEL FLAMES

As part of the DOE Existing Plants, Emissions and Capture (EPEC) program, oxy-combustion is being investigated as a method to simplify carbon capture and reduce the parasitic energy penalties associated with separating CO2 from a dilute flue gas. Gas-phase radiation heat transfer in boilers becomes significant when shifting from air-firing to oxycombustion, and must be accurately represented in models. Currently, radiative property data are not widely available in the literature for conditions appropriate to this environment. In order to facilitate the development and validation of accurate oxy-combustion models, NETL conducted a series of studies to measure radiation properties of oxy-fuel flames at adiabatic flame temperatures of 1750 - 1950K, and product molar concentrations ranging from 95% CO2 to 100% steam, determined by equilibrium calculations. Transmission coefficients were measured as a function of wavelength using a mid-IR imaging spectrometer and a blackbody radiation source. Additionally, flame temperatures were calculated using data collected within CO2 and H2O absorption bands. Experimental results were compared to two statistical narrowband models and experimental data from literature sources. These comparisons showed good overall agreement, although differences between the models and experimental results were noted, particularly for the R branch of the 2.7 μm H2O band.

54 ENVIRONMENTAL SCIENCES↗