Search NASA⌕ Search

SEARCH · Search NASA

Results for “storage consistency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

System design package for SIMS prototype system 4, solar heating and domestic hot water

The system consisted of a modular designed prepackaged solar unit, containing solar collectors, a rock storage container, blowers, dampers, ducting, air-to-water heat exchanger, DHW preheat tank, piping, and system controls. The system was designed to be installed adjacent to a small single family dwelling. The description, performance specification, subsystem drawings, verification plan/procedure, and hazard analysis of the system were packaged for evaluation.

Source record↗

Solar hot water system installed at Quality Inn, Key West, Florida

The solar energy hot water system installed in the Quality Inn, Key West, Florida, which consists of four buildings is described. Three buildings are low-rise, two-story buildings containing 100 rooms. The fourth is a four-story building with 48 rooms. The solar system was designed to provide approximately 50 percent of the energy required for the domestic hot water system. The solar system consists of approximately 1400 square feet of flat plate collector, two 500 gallon storage tanks, a circulating pump, and a controller. Operation of the system was begun in April 1978, and has continued to date with only three minor interruptions for pump repair. In the first year of operation, it was determined that the use of the solar facility resulted in forty percent fuel savings.

Source record↗

Solar energy system performance evaluation report for IBM System 4 at Clinton, Mississippi

The IBM System 4 Solar Energy System is described and evaluated. The system was designed to provide 35 percent of the space heating and 63 percent of the domestic hot water preheating for a single family residence located within the United States. The system consists of 259 square feet of flat plate air collectors, a rock thermal storage containing 5 1/2 ton of rock, heat exchangers, blowers, a 52 gallon preheat tank, controls, and associated plumbing. In general, the performance of the system did not meet design expectations, since the overall design solar fraction was 48 percent and the measured value was 32 percent. Although the measured space heating solar fraction at 32 percent did agree favorably with the design space heating solar fraction at 35 percent, the hot water measured solar fraction at 33 percent did not agree favorably with the design hot water solar fraction of 63 percent. In particular collector array air leakage, dust covered collectors, abnormal hot water demand, and the preheat tank by pass valve problem are main reasons for the lower performance.

Source record↗

The preparation and archiving of machine-readable astronomical data

The preparation of machine-readable astronomical catalogs for archiving and distribution from the ADC is described. Examples of specific format and data structure changes to improve compatibility with other computers, to homogenize the presentation of astronomical data among catalogs, and to increase storage efficiency are given. Various checks which are often made to insure internal consistency and for comparison with published versions are identified and the importance of permanently archiving astronomical data in the best possible condition is emphasized.

Warren, W. H., Jr.↗

Micro-optic lens for data storage

A new type of microlens for data storage applications that has improved off-axis performance is described. The lens consists of a micro Fresnel pattern on a curved substrate. The radius of the substrate is equal to the focal length of the lens. If the pattern and substrate are thin, the combination satisfies the Abbe sine condition. Therefore, the lens is free of coma. We analyze a 0.5 numerical aperture, 0.50 mm focal length lens in detail. A 0.16 numerical aperture lens was fabricated holographically, and results are presented.

Milster, T. D.↗

A lunar orbiting Node in support of missions to Mars

A conceptual design study yielded an approximate size for the platform needed to support typical oxygen-transfer rates which were based upon NASA studies of Mars missions. The Node consists of a gravity gradient stabilized lunar orbiting tank-farm with a storage capacity of 100,000 kg of lunar oxygen, 3300 kg of lunar cargo, and 9300 kg of earth-supplied hydrogen. An emergency-habitat configuration accommodates 14 persons on-board for 110 days. The Node supports an annual lunar oxygen production of 10 exp 6 kg with 220,000 kg of oxygen delivered to earth orbit for an expenditure of 109,000 kg of earth-supplied hydrogen.

Butterfield, A.↗

Simulation of a Flywheel Electrical System for Aerospace Applications

A Flywheel Energy Storage Demonstration Project was initiated at the NASA Glenn Research Center as a possible replacement for the battery energy storage system on the International Space Station (ISS). While the hardware fabrication work was being performed at a university and contractor's facility, the related simulation activity was begun at Glenn. At the top level, Glenn researchers simulated the operation of the ISS primary electrical system (as described in another paper) with the Flywheel Energy Storage Unit (FESU) replacing one Battery Charge and Discharge Unit (BCDU). The FESU consists of a Permanent Magnet Synchronous Motor/Generator (PMSM), which is connected to the flywheel; the power electronics that connects the PMSM to the ISS direct-current bus; and the associated controller. The PMSM model is still under development, but this paper describes the rest of the FESU model-the simulation of the converter and the associated control system that regulates energy transfer to and from the flywheel.

Truong, Long V.↗

DSN Beowulf Cluster-Based VLBI Correlator

The NASA Deep Space Network (DSN) requires a broadband VLBI (very long baseline interferometry) correlator to process data routinely taken as part of the VLBI source Catalogue Maintenance and Enhancement task (CAT M&E) and the Time and Earth Motion Precision Observations task (TEMPO). The data provided by these measurements are a crucial ingredient in the formation of precision deep-space navigation models. In addition, a VLBI correlator is needed to provide support for other VLBI related activities for both internal and external customers. The JPL VLBI Correlator (JVC) was designed, developed, and delivered to the DSN as a successor to the legacy Block II Correlator. The JVC is a full-capability VLBI correlator that uses software processes running on multiple computers to cross-correlate two-antenna broadband noise data. Components of this new system (see Figure 1) consist of Linux PCs integrated into a Beowulf Cluster, an existing Mark5 data storage system, a RAID array, an existing software correlator package (SoftC) originally developed for Delta DOR Navigation processing, and various custom- developed software processes and scripts. Parallel processing on the JVC is achieved by assigning slave nodes of the Beowulf cluster to process separate scans in parallel until all scans have been processed. Due to the single stream sequential playback of the Mark5 data, some ramp-up time is required before all nodes can have access to required scan data. Core functions of each processing step are accomplished using optimized C programs. The coordination and execution of these programs across the cluster is accomplished using Pearl scripts, PostgreSQL commands, and a handful of miscellaneous system utilities. Mark5 data modules are loaded on Mark5 Data systems playback units, one per station. Data processing is started when the operator scans the Mark5 systems and runs a script that reads various configuration files and then creates an experiment-dependent status database used to delegate parallel tasks between nodes and storage areas (see Figure 2). This script forks into three processes: extract, translate, and correlate. Each of these processes iterates on available scan data and updates the status database as the work for each scan is completed. The extract process coordinates and monitors the transfer of data from each of the Mark5s to the Beowulf RAID storage systems. The translate process monitors and executes the data conversion processes on available scan files, and writes the translated files to the slave nodes. The correlate process monitors the execution of SoftC correlation processes on the slave nodes for scans that have completed translation. A comparison of the JVC and the legacy Block II correlator outputs reveals they are well within a formal error, and that the data are comparable with respect to their use in flight navigation. The processing speed of the JVC is improved over the Block II correlator by a factor of 4, largely due to the elimination of the reel-to-reel tape drives used in the Block II correlator.

Rogstad, Stephen P.↗

VISCEL: A general-purpose computer program for analysis of linear viscoelastic structures (user's manual), volume 1

This program, an extension of the linear equilibrium problem solver ELAS, is an updated and extended version of its earlier form (written in FORTRAN 2 for the IBM 7094 computer). A synchronized material property concept utilizing incremental time steps and the finite element matrix displacement approach has been adopted for the current analysis. A special option enables employment of constant time steps in the logarithmic scale, thereby reducing computational efforts resulting from accumulative material memory effects. A wide variety of structures with elastic or viscoelastic material properties can be analyzed by VISCEL. The program is written in FORTRAN 5 language for the Univac 1108 computer operating under the EXEC 8 system. Dynamic storage allocation is automatically effected by the program, and the user may request up to 195K core memory in a 260K Univac 1108/EXEC 8 machine. The physical program VISCEL, consisting of about 7200 instructions, has four distinct links (segments), and the compiled program occupies a maximum of about 11700 words decimal of core storage.

Gupta, K. K.↗

Biomass accumulation in hydroponically grown sweetpotato in a controlled environment: a preliminary study

In the development of a plant growth model, the assumptions made and the general equations representing an understanding of plant growth are gradually refined as more information is acquired through experimentation. One such experiment that contributed to sweetpotato model development consisted of measuring biomass accumulation of sweetpotato grown in hydroponic culture in a plant growth chamber. Plants were started from fifteen centimeter long 'TU-82-155' sweetpotato vine cuttings spaced 25 cm apart in each of 18 rectangular growing channels (0.15 by 0.15 by 1.2m) in a system designed to use the nutrient film technique (NFT). Each channel contained four plants. The 3.5m by 5.2m plant growth chamber environmental parameters included an 18h photoperiod, 500 micromoles m-2 s-1 of photosynthetic photon flux (PPF), and a diurnal light/dark temperature of 28 degrees C/22 degrees C. The relative humidity was 80 +/- 5% and the CO2 partial pressure was ambient (350 ppm). The nutrient solution contained in 30L reservoirs was a modified half Hoagland's solution with a 1:2.4 N:K ratio and a pH of 6.2. Solution replenishment occurred when the electrical conductivity (EC) level dropped below 1050. Plants were harvested at 15 days after planting (DAP) and weekly thereafter until day 134. By 57 DAP, stems and fibrous roots had acquired 90% of their total dry biomass, while leaves had reached 84% of their maximum dry biomass. Beginning at 64 DAP dry biomass accumulation in the storage roots dominated the increase in dry biomass for the plants. Dry weight of storage roots at 120 DAP was 165 g/plant or 1.1 kg/m2. Resulting growth curves were consistent with the physiological processes occurring in the plant. Results from this study will be incorporated in a plant growth model for use in conjunction with controlled life support systems for long-term manned space missions.

Biomass↗

High Energy Propellants: A Continuing Bibliography

Through its Continuing Bibliography Program, NASA will prepare and distribute a series of bibliographies devoted to specific subjects in the aerospace field. The subjects have been selected because of their significant relationship to current developments in the space program, and because of a clearly established interest in them on the part of aerospace specialists. In order to assure that future information will become available in an orderly manner, each Continuing Bibliography will be updated periodically in the form of supplements which can be appended to the original edition. High Energy Propellants , NASA-SP-7002, is the first publication to appear under this program. It presents a selection of annotated references to unclassified reports and journal articles announced in Technical Publications Announcements (TPA) , Scientific and Technical Aerospace Reports (STAR) , and International Aerospace Abstracts (IAA) . Prime emphasis is given to those references which are concerned with research and development studies on solid, liquid, and hybrid propellants and oxidizers, but the bibliography also provides extensive coverage of such related topics as propellant handling and storage, combustion characteristics, toxicity, and hazards and safety measures. Each entry in the bibliography consists of a citation and an abstract. The listing of entries is arranged in two major groups: all report literature references are contained in the first group and are subdivided according to their date of announcement in TPA and STAR ; the second group includes all published literature references subdivided according to their date of announcement in IAA . All reports and articles cited were introduced into the NASA Information System during the period January 1962-March, 1964.

Bibliography↗

Solar energy system performance evaluation report for Solaron-Duffield, Duffield, Virginia

The Solaron Duffield Solar Energy System was designed to provide 51 percent of the space heating, and 49 percent of the domestic hot water (DHW) to a two story 1940 square foot area residence using air as the transport medium. The system consists of a 429 square foot collector array, a 265 cubic foot rock thermal storage bin, heat exchangers, an 80 gallon DHW preheat tank, pumps, blowers, controls, air ducting and associated plumbing. A air-to-liquid heat pump coupled with a 1,000gallon water storage tank provides for auxiliary space heating and can also be used for space cooling. A 52 gallon electric DHW tank using the solar preheated water provides domestic hot water to the residence. The solar system, which became operational July 1979, has the following modes of operation: First Stage: (1) collector to storage and DHW; (2)collector to space heating; (3) storage to load. Second Stage: (4) heat pump auxiliary direct; (5) auxiliary heat from heat pump storage. Third Stage: (6) electrical resistance (strip) heat.

Source record↗

Solar-Heated Water at a Motel--Mobile, Alabama

Solar-assisted hot-water system for a new 122-unit motor inn in Mobile, Alabama, generates more than half the energy needed for hot-water heating at motel each year. System consists of 93 flat-plate collectors, 2,500 gallon (9,500 1) insulated storage tank located outdoors, heat exchangers and controls. Electronic thermometers, measuring the temperatures at 22 locations monitor system performance.

Source record↗

The Remote Computer Control (RCC) system

A system to remotely control job flow on a host computer from any touchtone telephone is briefly described. Using this system a computer programmer can submit jobs to a host computer from any touchtone telephone. In addition the system can be instructed by the user to call back when a job is finished. Because of this system every touchtone telephone becomes a conversant computer peripheral. This system known as the Remote Computer Control (RCC) system utilizes touchtone input, touchtone output, voice input, and voice output. The RCC system is microprocessor based and is currently using the INTEL 80/30microcomputer. Using the RCC system a user can submit, cancel, and check the status of jobs on a host computer. The RCC system peripherals consist of a CRT for operator control, a printer for logging all activity, mass storage for the storage of user parameters, and a PROM card for program storage.

Holmes, W.↗

Solar heating system installed at Troy, Ohio

The completed system was composed of three basic subsystems: the collector system consisting of 3,264 square feet of Owens Illinois evacuated glass tube collectors; the storage system which included a 5,000 gallon insulated steel tank; and the distribution and control system which included piping, pumping and heat transfer components as well as the solemoid activated valves and control logic for the efficient and safe operation of the entire system. This solar heating system was installed in an existing facility and was, therefore, a retrofit system. Extracts from the site files, specifications, drawings, installation, operation and maintenance instructions are included.

Source record↗

Design description of the Schuchuli Village photovoltaic power system

A stand alone photovoltaic (PV) power system for the village of Schuchuli (Gunsight), Arizona, on the Papago Indian Reservation is a limited energy, all 120 V (d.c.) system to which loads cannot be arbitrarily added and consists of a 3.5 kW (peak) PV array, 2380 ampere-hours of battery storage, an electrical equipment building, a 120 V (d.c.) electrical distribution network, and equipment and automatic controls to provide control power for pumping water into an existing water system; operating 15 refrigerators, a clothes washing machine, a sewing machine, and lights for each of the homes and communal buildings. A solar hot water heater supplies hot water for the washing machine and communal laundry. Automatic control systems provide voltage control by limiting the number of PV strings supplying power during system operation and battery charging, and load management for operating high priority at the expense of low priority loads as the main battery becomes depleted.

Ratajczak, A. F.↗

Instant-replay data system for combustion tests

A portable, inexpensive, easily programmed, and flexible pressure measuring and display system is described and evaluated in a multi-port combustion model. The data reduction system consists of a desk-top graphics display system and calculator with data tape storage and standard data communications interfacing capabilities, while a hard copy unit provides a permanent record of all plots and tables. The system offers the advantages of recording and comparing a large number of pressures at high data rates along with the display of the results in a meaningful graphical form for near real time analysis. Some discussion of combustor and engine experiments are included as examples of the data system application.

Trexler, C. A.↗

Design description of the Tangaye Village photovoltaic power system

The engineering design of a stand alone photovoltaic (PV) powered grain mill and water pump for the village of Tangaye, Upper Volta is described. The socioeconomic effects of reducing the time required by women in rural areas for drawing water and grinding grain were studied. The suitability of photovoltaic technology for use in rural areas by people of limited technical training was demonstrated. The PV system consists of a 1.8-kW (peak) solar cell array, 540 ampere hours of battery storage, instrumentation, automatic controls, and a data collection and storage system. The PV system is situated near an improved village well and supplies d.c. power to a grain mill and a water pump. The array is located in a fenced area and the mill, battery, instruments, controls, and data system are in a mill building. A water storage tank is located near the well. The system employs automatic controls which provide battery charge regulation and system over and under voltage protection. This report includes descriptions of the engineering design of the system and of the load that it serves; a discussion of PV array and battery sizing methodology; descriptions of the mechanical and electrical designs including the array, battery, controls, and instrumentation; and a discussion of the safety features. The system became operational on March 1, 1979.

Martz, J. E.↗