Search NASA⌕ Search

SEARCH · Search NASA

Results for “storage tank”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Investigating Dual Electrospinning as a Means of Enhancing Passive Thermal Control Coatings for Cryogenic Propellant Storage in Extraterrestrial Environments

Passive thermal control is necessary as space exploration becomes increasingly widespread. Materials with superior optical properties (high solar reflectance and infrared emittance) are critical for passive thermal control because they can reject most of the incident solar radiation and promote thermal emission from cryogenic propellant storage tanks, enabling the extraterrestrial storage of cryogens. We have demonstrated in previous studies that electrospun nanofibers exhibit exceptional optical properties, offering significant benefits for passive radiative cooling in space. Particularly, electrospun polyvinylidene fluoride-co-hexafluoropropylene PVDF-HFP nanofibers demonstrate exceptionally high solar reflectance (>99%) and strong thermal emittance (measured at ~300 K). However, they exhibit nanostructural changes in the presence of atomic oxygen, which is prevalent in Low Earth Orbit. This study focuses on creating a unique blend of polymeric (PVDF-HFP) and ceramic-based (silica) nanofibers by leveraging the chemical stability and atomic oxygen resistance of silica, using the dual electrospinning manufacturing method. This approach aims to preserve the structural properties of the polymeric counterpart without compromising its optical performance, thereby providing an innovative method for manufacturing environmentally resilient passive thermal control nanofibers with desirable optical and thermal control functionalities for extraterrestrial storage of cryogenic propellants.

Chieloka Ibekwe↗

Integrated hydrogen recycle system using pressurized multichamber tank

A multi-chambered electrolyte storage tank for a redox flow battery system, may include first and second electrolyte chambers, and a bulkhead, wherein the first and second electrolyte chambers are fluidly coupled to first and second sides of a redox flow battery cell, respectively, the first and second electrolyte chambers include first and second liquid electrolyte volumes, respectively, and the first and second liquid electrolyte volumes are separated by the bulkhead positioned therebetween. In this way, manufacturing and operational complexity of a redox flow battery system can be reduced.

Song, Yang↗

Thermodynamic parametric analysis of refueling heavy-duty hydrogen fuel-cell electric vehicles

Reliable design and safe operation of heavy-duty hydrogen refueling stations are essential for the successful deployment of heavy-duty fuel cell electric vehicles (FCEVs). Fueling heavy-duty FCEVs is different from light-duty vehicles in terms of the dispensed hydrogen quantities and fueling rates, requiring tailored fueling station design for each vehicle class. In particular, the selection and design of the onboard hydrogen storage tank system and the fueling performance requirements influence the safe design of hydrogen fueling stations. A thermodynamic modeling and analysis are performed to evaluate the impact of various fueling parameters and boundary conditions on the fueling performance of heavy-duty FCEVs. Here, we studied the effect of dispenser pressure ramp rate and precooling temperature, initial tank temperature and pressure, ambient temperature, and onboard storage design parameters, such as onboard storage pipe diameter and length, on the fueling rate and final vehicle state-of-charge, while observing prescribed tank pressure and temperature safety limits. An important finding was the sensitivity of the temporal fueling rate profile and the final tank state of charge to the design factors impacting pressure drop between the dispenser and vehicle tank, including onboard storage pipe diameter selection, and flow coefficients of nozzle, valves, and fittings. The fueling rate profile impacts the design and cost of the hydrogen precooling unit upstream of the dispenser.

08 HYDROGEN↗

Off-design operation and performance of pumped thermal energy storage

In this article, we describe off-design models and control strategies for a Pumped Thermal Energy Storage (PTES) system that uses liquid thermal energy storage: specifically molten salt for hot storage and methanol for cold storage. Off-design conditions arise when load-following, or due to variations in storage tank temperatures or ambient temperatures. We propose a control strategy that uses inventory control to manage the mass flow rate in the thermodynamic cycles, which facilitates load following. We also propose a control strategy for the storage fluid mass flow rates, which are varied to ensure the molten salt is maintained at its design temperature. This maximizes efficiency and minimizes problems with salt freezing or degradation. The cold storage fluid mass flow rate is varied so that the cold tanks have the same state-of-charge as the hot tanks. This leads to variations in cold fluid temperature, but these variations are shown to be acceptably small (e.g. 7.5% increase), and this control method is shown to be simpler and more efficient than an alternative strategy where tanks become unbalanced. The ambient temperature and storage tank temperatures are moved ±50 °C from the design values and the impact on power, duration, and tank temperatures is quantified. Results demonstrate that the proposed control strategy is stable and self-correcting - that is, storage temperatures converge on stable values after two-to-three charge-discharge cycles. When inputs return to design values, the system returns to its design point after two charge-discharge cycles. We also demonstrate that inventory control enables delivery of the target power output even when off-design conditions exist that would normally reduce the power output.

25 ENERGY STORAGE↗

Mitigation of Silver Ion Loss from Solution by Polymer Coating of Metal Surfaces, Part IV

Ionic silver (Ag+) biocide is a leading candidate to provide residual microbial control in spacecraft potable water systems, but suffers from rapid concentration loss due to interactions with the metallic storage containers and tubing. One approach to resolve this problem is the coating of metal surfaces with an inert barrier film. In previous reports, we have described our investigations addressing Ag+ loss mitigation and adhesion performance of parylene barrier coatings on coupons of several metal alloys and 316Ltubing under static immersion. In such conditions, parylene-C and -AF4 coatings have shown excellent Ag+loss mitigation and mixed long-term adhesion performance, depending on parylene species and substrate surface chemistry/structure. In Part IV of this series, we report on our work to investigate the performance of parylene-C barrier coatings, under more challenging and realistic conditions, in order to evaluate potential suitability for use. The resilience and associated Ag+ loss with Parylene-C coating on½” (12.7 mm)316L tubing and fittings under medium-term immersion and repeated fitting dis/reassembly were investigated. Potential mechanical challenges to barrier coatings in spacecraft potable water systems were investigated, with two main focuses being identified: liquid flow/pressure cycling in tubing and cyclic operation of bellows in positive-expulsion storage tanks. Two corresponding testbeds for experimental characterization of coating performance were developed. In the Flow/Pressure Testbed System, Ag+ solution will be pumped through internally coated 316L tubing, with optional pressure cycling. In the Bellows Tank Testbed System, an internally coated edge-welded 316L bellows containing Ag+ solution will be cyclically extended and compressed, analogous to the operation of bellows tanks used for potable water storage and delivery on the International Space Station. The design and operation of these testbeds are described. Finally, the Ag+ adsorption and saturation behaviors of Kalrez and Viton, for potential use as seal materials in fittings and other connections, were characterized in limited experiments.

mitigation↗

Re-Designing the CSP Thermal Energy Storage System to Enable Higher-Temperature Performance at Reduced Cost (Final Technical Report)

Current commercial concentrating solar power (CSP) plants distinguish themselves from ordinary photovoltaic (PV) power plants by storing enough collected energy to enable generation for several hours after the sun goes down. CSP plants store this energy in the sensible heat of nitrate salts in large metallic storage tanks. Stainless-steel AISI 347H (SS347H) is needed for the hot tank operating at about 565 degrees C whereas carbon steel is sufficient for the cold-tank materials. Two-tank nitrate-salt thermal energy storage (TES) is presently in use in several trough-based CSP plants in Europe and in the U.S., operating up to about 390 degrees C. Three commercially operating tower-based CSP plants - Gemasolar in Spain, Crescent Dunes in Nevada, and Noor III in Morocco - use the same approach, storing nitrate salts at temperatures up to 580 degrees C. SS347H is many times more expensive than carbon steel and constitutes a significant cost element in today's CSP plants. Hence, CSP developers need to close the cost gap with PV-based solar plants by making cost reductions in every system of the plant. Redesigning the TES tanks is one opportunity for cost reduction.

14 SOLAR ENERGY↗

Rocking response of liquid-filled cylindrical tanks

The hydrodynamic response of liquid-filled storage tanks subjected to translational earthquake shaking has been the focus of studies for more than 75 years. In service, tanks experience six components of seismic input, with rocking due to support flexibility and/or rotational components of ground motion. Published theory for predicting hydrodynamic responses in rigid cylindrical tanks due to rotational seismic input is examined. Analytical solutions for pressure in the fluid and on the tank wall, and base moment are modified to account for the effects of angular displacements at the base. A finite element model of a water-filled cylindrical tank using the Arbitrary Lagrangian and Eulerian (ALE) solver in LS-DYNA is used to demonstrate the efficacy of the proposed expressions for three base rocking motions. Results from the modified analytical solutions and the finite element model are in excellent agreement.

58 GEOSCIENCES↗

Analysis of different operating strategies of thermal energy storage with radiant cooling system

Thermal energy storage systems in building cooling applications have been explored extensively as a peak load-shifting technology. Thermal energy storage performance has been recognized and studied from an energy cost-savings point of view because of peak-valley price differences, but not many studies have been conducted from an energy savings viewpoint. This study experimentally investigates the performance of the energy storage-retrofitted to a ceiling-type radiant cooling system. To study the performance, a water-based storage system was designed and developed for an academic office building equipped with a radiant cooling system. The water in the storage tank was cooled to a certain storage temperature in the nighttime, and the same water was used during the daytime for meeting the cooling load. Different combinations of charging and discharging schedules were analyzed. The key objective of the study was to achieve energy savings and energy-cost savings simultaneously. This objective was accomplished by identifying the major factors contributing to the energy consumption of the storage-retrofitted cooling system and devising novel operating strategies, leading to an enhanced energy savings potential. Two operating strategies comprising 24 operating scenarios were compared and the storage was used to dispatch the load for 3 hours of the day as a full storage unit. Results showed that in hot and dry climate conditions, using the storage with the radiant cooling system offered energy savings of 3% to 14%. The energy-cost analysis was also performed using a time-of-day electricity tariff plan. The energy-cost savings varied from 17.5% to 22.4% for these operating scenarios.

25 ENERGY STORAGE↗

Cryogenic foam insulation: Abstracted publications

A group of documents were chosen and abstracted which contain information on the properties of foam materials and on the use of foams as thermal insulation at cryogenic temperatures. The properties include thermal properties, mechanical properties, and compatibility properties with oxygen and other cryogenic fluids. Uses of foams include applications as thermal insulation for spacecraft propellant tanks, and for liquefied natural gas storage tanks and pipelines.

Williamson, F. R.↗

Developing NDE Techniques for Large Cryogenic Tanks

The Shuttle Program requires very large cryogenic ground storage tanks in which to store liquid oxygen and hydrogen. The existing Pads A and B Launch Complex-39 tanks, which will be passed onto future launch programs, are 45 years old and have received minimal refurbishment and only external inspections over the years. The majority of the structure is inaccessible without a full system drain of cryogenic liquid and granular insulation in the annular region. It was previously thought that there was a limit to the number of temperature cycles that the tanks could handle due to possible insulation compaction before undergoing a costly and time consuming complete overhaul; therefore the tanks were not drained and performance issues with these tanks, specifically the Pad B liquid hydrogen tank, were accepted. There is a needind an opportunity, as the Shuttle program ends and work to upgrade the launch pads progresses, to develop innovative non-destructive evaluation (NDE) techniques to analyze the current tanks. Techniques are desired that can aid in determining the extent of refurbishment required to keep the tanks in service for another 20+ years. A nondestructive technique would also be a significant aid in acceptance testing of new and refurbished tanks, saving significant time and money, if corrective actions can be taken before cryogen is introduced to the systems.

Parker, Don↗

World’s Largest Liquid Hydrogen Tank Nearing Completion

Construction of the world’s largest liquid hydrogen (LH 2 ) storage tank is almost complete at launch pad 39B at NASA Kennedy Space Center (KSC) in Florida. With a usable capacity of 4732 m 3 (1.25 Mgal), this new vessel is roughly 50% larger than its sister tank, which is located 170 m (550 ft) to the southeast. Once the new sphere is fully commissioned these two tanks will provide a combined LH 2 storage capacity of 7950 m 3 (2.1 Mgal) to fuel the new Space Launch System rocket in support of future Artemis exploration missions to the Moon and Mars.

Adam Swanger↗

Issues of Long-Term Cryogenic Propellant Storage in Microgravity

Modern multi-layer insulation (MLI) allows to sharply reduce the heat leak into cryogenic propellant storage tanks through the tank surface and, as a consequence, significantly extend the storage duration. In this situation the MLI penetrations, such as support struts, feed lines, etc., become one of the most significant challenges of the tanks heat management. This problem is especially acute for liquid hydrogen (LH2) storage, since currently no efficient cryocoolers exist that operate at very low LH2 temperatures (20K). Even small heat leaks under microgravity conditions and over the period of many months give rise to a complex slowly-developing, large-scale spatiotemporal physical phenomena in a multi-phase liquid-vapor mixture. These phenomena are not well-understood nor can be easily controlled. They can be of a potentially hazardous nature for long-term on-orbital cryogenic torage, propellant loading, tank chilldown, engine restart, and other in-space cryogenic fluid management operations. To support the engineering design solutions that would mitigate these effects a detailed physics-based analysis of heat transfer, vapor bubble formation, growth, motion, coalescence and collapse is required in the presence of stirring jets of different configurations and passive cooling devices such as MLI, thermodynamic vent system, and vapor-cooled shield. To develop physics-based models and correlations reliable for microgravity conditions and long-time scales there is a need for new fundamental data to be collected from on-orbit cryogenic storage experiments. Our report discusses some of these physical phenomena and the design requirements and future studies necessary for their mitigation. Special attention is payed to the phenomena occurring near MLI penetrations.

Muratov, C. B.↗

Processing of combined domestic bath and laundry waste waters for reuse as commode flushing water

An experimental investigation of processes and system configurations for reclaiming combined bath and laundry waste waters for reuse as commode flush water was conducted. A 90-min recycle flow was effective in removing particulates and in improving other physical characteristics to the extent that the filtered water was subjectively acceptable for reuse. The addition of a charcoal filter resulted in noticeable improvements in color, turbidity, and suds elimination. Heating and chlorination of the waste waters were investigated for reducing total organism counts and eliminating coliform organisms. A temperature of 335.9 K (145 F) for 30 min and chlorine concentrations of 20 mg/l in the collection tank followed by 10 mg/l in the storage tank were determined to be adequate for this purpose. Water volume relationships and energy-use rates for the waste water reuse systems are also discussed.

Hypes, W. D.↗

Design of an unmanned lunar cargo lander that reconfigures into a shelter for a habitation module or disassembles into parts useful to a permanent manned lunar base

NASA plans to establish a permanent manned lunar base by the first decade of the twenty-first century. It is extremely expensive to transport material from earth to the moon. Therefore, expense would be reduced if the vehicle that lands cargo on the moon could itself meet some of the material needs of establishing the lunar base. The design of a multi-functional lander that is entirely useful to the base after landing is described. Alternate designs of the overall lander configuration and possible uses of the lander and its components after landing are contained. The design solution is a lander employing the Saddlebagged Fuel Tank Configuration. After landing, its structure will be converted into a habitation module shelter that supports a protective layer of regolith. The fuel tanks will be cleaned and used as storage tanks for the lunar base. The engines and instrumentation will be saved as stock parts. Recommendations for further research and technology development to enhance future lander designs are given.

Davanay, Lisa↗

Thermographic Methods of Detecting Insulation Voids in Large Cryogenic Tanks

Four very large (900Kgal) cryogenic liquid hydrogen and oxygen storage tanks at Kennedy Space Center's LC-39 launch pads were constructed in 1965 to support the Apollo/Saturn V Program and continue to support the Space Shuttle Program. These double-walled spherical tanks with powdered insulation in the annular region, have received minimal refurbishment or even inspection over the years. As the Shuttle Program comes to an end we now have the time to perform limited refurbishment. Thermography has been used to monitor the state of insulation as one of the four tanks was drained of cryogen and warmed to ambient temperatures. An anomalous region of insulation detected previously with thermography was confirmed by visual inspections during this period. Thermal models and a comparison of images from the cold and warm tanks suggests that the anomalous region can be detected even without cryogen in the tank. The ability to detect and correct probable insulation voids prior to filling with cryogenic fluid can provide significant cost savings by reducing commodity boil-off over many years of use.

Arens, Ellen↗

Thermographic Methods of Detecting Insulation Voids in Large Cryogenic Tanks

Four very large (900Kgal) cryogenic liquid hydrogen and oxygen storage tanks at Kennedy Space Center's LC-39 launch pads were constructed in 1965 to support the Apollo/Saturn V Program and continue to support the Space Shuttle Program. These double-walled spherical tanks with powdered insulation in the annular region, have received minimal refurbishment or even inspection over the years. Intrusively inspecting these tanks would mean a significant down time to the program as the cryogenic liquid and the perlite insulation would have to be removed which would be a significant task and long-term schedule disruption. A study of the tanks was performed to determine the extent to which performance and structural information could be revealed without intrusive inspection. Thermal images of the tanks were taken over a variety of environmental conditions to determine the best conditions under which to compare and use thermography as a health monitoring technique as the tanks continue to age. The settling and subsequent compaction of insulation is a serious concern for cryogenic tanks. Comparison of images from the tanks reveals significant variations in the insulation in the annual regions and point to the use of thermography as a way to monitor for insulation migration and possible compaction. These measurements, when combined with mathematical models of historical boil-off data provide key insight to the condition of the vessels. Acceptance testing methods for new tanks, before they are filled with cryogenic commodity (and thereby thermally cycled), are needed and we explore how thermography can be used to accomplish this.

Arens, Ellen↗